Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-781R-031
-) ro U �_0 E ED] 0 1 2 3 4 5 6 7 DOOR SCHEDULE -SIXTH FLOOR LEVEL MARK TYPE DOOR FRAME GLAZING FIRE RATING HARDWARE Comments SIZE MATERIAL FINISH MATERIAL FINISH WIDTH HEIGHT THICKNESS HW9 (STAIR EGRESS) 1 HOSPITAL LOCKSET 2 PAIR BUTT HINGES* 1 OVERHEAD STOP 1 EXIT DEVICE 3 SILENCERS 1 CLOSER 2 MOP PLATES 3 SILENCERS REVISIONS /ISSUES 1 KICK PLATE HW2 (TYP. PATIENT ROOM TOILET) 1 -112 PAIR BUTT HINGES SIXTH FLOOR 1 PRIVACY LOCKSET 4 PAIR BUTT HINGES 1 WALL STOP 2 EXIT DEVICES 3 SILENCERS 2 CLOSERS 2 MOP PLATES 3 SILENCERS 2 KICK PLATES HW3_(TYP. CLEAN HOLDING, 2 MOP PLATES NOURISHMENT, EQUIP. STORAGE) SIXTH FLOOR 600B A 3' - 10" 7' - 0" 0' - 1 3/4" HM MP ETR MP HW11(I.T./TELE AND HOUSEKEEPING, STORAGE) 3 SILENCERS HW9 SIXTH FLOOR 600P BB 71-411 7' - 0" 0' -1 3/4" SCP PL HM MP FRG 90 MIN (B) HW10 FIRE /SMOKE SIXTH FLOOR 601 A 3' - 10" 7' - 0" 0' - 1 3/4" SCP PL ETR MP 3 SILENCERS 1 KICK PLATE HW1 1 SIXTH FLOOR 601A A 3' - 0" 71-011 0' - 1 3/4" SCP PL HM MP 1 MOP PLATE 1 WALL STOP HW2 5 SIXTH FLOOR 602 A 31-10" 7' - 0" 0' - 1 3/4" SCP PL ETR MP 2 MOP PLATES 1 AUTOMATIC FLUSHBOLT HW1 1 SIXTH FLOOR 602A A 31-0" 7' - 0" 0' - 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 603 A 3' - 10" 7' - 0" 0'- 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 603A A 3' - 0" 7'-0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 604 A 3' - 10" 7' - 0" 0'- 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 604A A 3' - 0" 71-0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 605 A 3' - 10" 7' - 0" 0' - 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 605A A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 606 A 3' - 10" 71-0" 0' - 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 606A A 3'-0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 607 A 3' - 10" 71-011 0'- 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 607A A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 608 A 3' - 10" 7' - 0" 0'- 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 608A A 3' - 0" 7' - 0" 0' -1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 609 A 3' - 10" 7' - 0" 0'- 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 609A A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 610 A 3' - 10" T-011 0' - 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 610A A 3' - 0" 7' - 0" 0' -1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 611 A 3' - 10" 7' - 0" 0' - 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 611A A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 612 A 31-1011 7' - 0" 0' - 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 612A A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 615 A 3' - 10" 71-01' 0'- 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 615A A 3' - 0" 7' - 0" 0' - 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 616 A 3' - 10" 71-0" 0'- 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 616A A 3' - 0" 7' - 0" 0' - 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 617 A 3' - 10" 71-0" 0' - 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 617A A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 618 A 3' - 10" 71-0" 0' - 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 618A A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 619 A 3' - 10" 7' - 0" 0'- 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 619A A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 620 A 3' - 10" 7' - 0" 0'- 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 620A A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 621 A 3' - 10" 7' - 0" 0'- 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 621A A 3' - 0" 7' - 0" 0' - 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 622 A 3' - 10" 7' - 0" 0' - 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 622A A 3' - 0" 7' - 0" 0' - 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 623 A 3' - 10" 7' - 0" 0' - 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 623A A 3' - 0" 71-0" 0' - 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 624 A 3' - 10" 7' - 0" 0'- 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 624A A 3' - 0" 7' - 0" 0' - 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 625 A 3' - 10" 71-0" 0' - 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 625A A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 626 A 3' - 10" 7' - 0" 0' - 1 3/4" SCP PL ETR MP HW1 1 SIXTH FLOOR 626A A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW2 5 SIXTH FLOOR 627A AA 7' - 0" 7' - 0" 0' - 1 3/4" SCP PL HM MP HW7 2 3 SIXTH FLOOR 627B A 3' - 6" 7' - 0" 0' - 1 3/4" SCP PL HM MP HW7 2,3 SIXTH FLOOR 627C A 3' - 6" 7' - 0" 0' -1 3/4" SCP PL HM MP HW7 2,3 SIXTH FLOOR 628 A 3' - 2" 7' - 0" 0' - 1 3/4" SCP PL HM MP 45 MIN (C) HW3 SIXTH FLOOR 629 A 3' - 0" 7' - 0" 0' -1 3/4" SCP PL HM MP HW11 1 SIXTH FLOOR 630 C 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP CTG HW6 SIXTH FLOOR 631 C 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP CTG HW3 SIXTH FLOOR 632 A 31-6" 7' - 0" 0'- 1 3/4" SCP PL HM MP 45 MIN (C) HW4 SIXTH FLOOR 633 C 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP CTG HW5 SIXTH FLOOR 639 A 3' - 0" 7' - 0" 0' - 1 3/4" SCP PL HM MP HW13 SIXTH FLOOR 640 A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW12 SIXTH FLOOR 642 A 31-0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW6 SIXTH FLOOR 643 A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP 45 MIN (C) HW6 SIXTH FLOOR 644 A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP 45 MIN (C) HW3 SIXTH FLOOR 645A & A 3' - 0" 7' - 0" 0' -1 3/4" SCP PL HM MP HW11 SIXTH FLOOR 645B A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW11 SIXTH FLOOR A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW14 SIXTH FLOOR 647 A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP HW11 SIXTH FLOOR 648 A 3' - 0" 7' - 0" 0'- 1 3/4" SCP PL ETR MP 90 MIN (B) HW3 SIXTH FLOOR 649 A 2' - 8" 7' - 0" 0'- 1 3/4" SCP PL ETR MP HW13 SIXTH FLOOR 650 A 2' - 8" 71-0" 0' - 1 3/4" SCP PL ETR MP HW13 SIXTH FLOOR 651 A 3' - 10" 7' - 0" 0'- 1 3/4" HM MP ETR MP 90 MIN (B) HW9 SIXTH FLOOR 652 A 3' - 0" 7' - 0" 0' -1 3/4" SCP PL ETR MP HW6 SIXTH FLOOR 653 A 3' - 6" 7' - 0" 0'- 1 3/4" SCP PL ETR MP 45 MIN (C) HW11 SIXTH FLOOR 654 A 3' - 6" 7' - 0" 0'- 1 3/4" SCP PL ETR MP HW6 SIXTH FLOOR 656 BB 6' - 0" 7' - 0" 0' -1 3/4" SCP PL ETR MP CTG HW10 SIXTH FLOOR 657 A 3' - 10" 7' - 0" 0'- 1 3/4" HM MP ETR MP 90 MIN (B) HW9 SIXTH FLOOR 658 BB 6' - 0" 7' - 0" 0' - 1 3/4" SCP PL ETR MP CTG HW10 SIXTH FLOOR 695 AA 5' - 0" 7' - 0" 0' -1 3/4" SCP PL ETR MP 45 MIN (C) HW8 3 SIXTH FLOOR 696 AA 5' - 0" 7' - 0" 0' -1 3/4" SCP PL ETR MP 45 MIN (C) HW8 3 SIXTH FLOOR 697 AA 6' - 0" 7' - 0" 0'- 1 3/4" SCP PL HM MP 45 MIN (C) HW8 3 SIXTH FLOOR 698 A 3' - 0" 7' - 0" 0' -1 3/4" SCP PL ETR MP HW11 3 SIXTH FLOOR 699 1 A 3' - 0" 7' - 0" 0' - 1 3/4" SCP PL ETR MP HW11 3 1. NUMBER: SEE FLOOR PLAN FOR DOOR NUMBER 2. DOOR ELEVATION: SEE TYPES BELOW SEE SCHEDULE SEE SHEDULE � w i I W I w U3 1 i J TYPE A TYPE AA DOOR LEGEND SEE SCHEDULE SEE SHEDULE � I II I u I 3. DOOR SIZE: SEE SCHEDULE FOR WIDTH, HEIGHT AND THICKNESS 4. DOOR MATERIAL: SCV = SOLID CORE W/ WOOD VENEER FACES SCH = SOLID CORE W/ HARDBOARD FACES SCP = SOLID CORE PLASTIC LAMINATE FACES SCA = SOLID CORE ACROVYN FACES HM = HOLLOW METAL GHM = GALVANIZED HOLLOW METAL AL = ALUMINUM & GLASS LL = LEAD LINED 5. DOOR FINISH: WTF = WOOD TRANSPARENT FINISH WOF = WOOD OPAQUE FINISH MGP = METAL GALVANIZED PAINTED MP = METAL PAINTED AL = ANODIZED ALUMINUM PL = PLASTIC LAMINATE TYPE B TYPE BB 6. GLASS TYPE: J SEE SCHEDULE SEE SHEDULE F -1 I M I I LJI 9 [VARIES [9 N I I J WG =114" WIRE GLASS CTG =114" CLEAR TEMPERED GLASS LG =1/4" LEADED GLASS FRG =114" FIRE RATED GLASS rA11".121&1 :1&MI4V09 WD = WOOD HM = HOLLOW METAL GHM = GALVANIZED HOLLOW METAL AL = ALUMINUM KID = HOLLOW METAL KNOCK DOWN FRAME HMLL = HOLLOW METAL, LEAD LINED ETR = EXISTING TO REMAIN �:7:Put�Iflb9;E WTF = WOOD TRANSPARENT FINISH WOF = WOOD OPAQUE FINISH MGP = METAL GALVANIZED PAINTED MP = METAL, PAINTED AL = ANODIZED ALUMINUM HMLL = HOLLOW METAL, LEAD LINED HW1 (TYPICAL PATIENT ROOMS) HW8 (ELECTRICAL) 11/2 PAIR HEAVY DUTY SWING CLEAR 3 PAIR BUTT HINGES* (180 SWING CLEAR) HINGES* ON EXISTING AND NEW FRAMES 1 STORAGE LOCKSET 1 HOSPITAL LATCH SET 1 AUTOMATIC FLUSHBOLT 1 WALL STOP 2 CLOSERS 3 SILENCERS 1 ASTRAGAL 2 MOP PLATES 6 SILENCERS PRICING SET 4 MOP PLATES HW1A (VIP ROOM 715 -717) 50% CONSTRUCTION SET 2 PAIR SWING CLEAR BUTT HINGES* HW9 (STAIR EGRESS) 1 HOSPITAL LOCKSET 2 PAIR BUTT HINGES* 1 OVERHEAD STOP 1 EXIT DEVICE 3 SILENCERS 1 CLOSER 2 MOP PLATES 3 SILENCERS REVISIONS /ISSUES 1 KICK PLATE HW2 (TYP. PATIENT ROOM TOILET) 1 -112 PAIR BUTT HINGES HW10 (CROSS CORRIDOR) 1 PRIVACY LOCKSET 4 PAIR BUTT HINGES 1 WALL STOP 2 EXIT DEVICES 3 SILENCERS 2 CLOSERS 2 MOP PLATES 3 SILENCERS 2 KICK PLATES HW3_(TYP. CLEAN HOLDING, 2 MOP PLATES NOURISHMENT, EQUIP. STORAGE) 1 ASTRAGAL 2 PAIR SWING CLEAR BUTT HINGES 1 METAL THRESHOLD (FLAT) 1 E -PLEX LOCKSET 1 EACH EDGE PROTECTION 1 CLOSER 1 AUTO DOOR OPERATOR 1 KICK PLATE 1 MOP PLATE HW11(I.T./TELE AND HOUSEKEEPING, STORAGE) 3 SILENCERS 1 -112 PAIR BUTT HINGES (180 SWING CLEAR IF OPENING INTO CORRIDOR) HW4 (SOILED HOLDING) 1 STORAGE LOCKSET 2 PAIR SWING CLEAR BUTT HINGES 1 CLOSER 1 PASSAGE LOCKSET 2 MOP PLATES 1 CLOSER 3 SILENCERS 1 KICK PLATE 1 MOP PLATE HW12 (STAFF LOUNGE) 3 SILENCERS 1 -1/2 PAIR BUTT HINGES 1 E -PLEX LOCKSET HW5 (MED PREP) 1 CLOSER 1 -1/2 PAIR BUTT HINGES 1 KICK PLATE 1 ELECTRIC STRIKE /CARD SWIPE 1 MOP PLATE 1 CLOSER 3 SILENCERS 1 KICK PLATE 1 MOP PLATE HW13 (STAFF AND PUBLIC TOILET) 3 SILENCERS 1 -112 PAIR BUTT HINGES 1 PRIVACY LOCKSET HW6 (OFFICES) 1 CLOSER 1 -1/2 PAIR BUTT HINGES 1 KICK PLATE 1 OFFICE LOCKSET 1 MOP PLATE 1 WALL STOP 3 SILENCERS 2 MOP PLATES 3 SILENCERS HW14 (FAMILY WAITING) 1 -112 PAIR 180 DEGREE BUTT HINGES HW7 (MECHANICAL ROOM) 1 PASSAGE LOCKSET 3 PAIR BUTT HINGES 180 SWING CLEAR 1 WALL STOP 1 STORAGE LOCKSET 2 MOP PLATES 1 AUTOMATIC FLUSHBOLT 3 SILENCERS 2 CLOSERS 1ASTRAGAL 1 THRESHOLD 4 MOP PLATES 6 SILENCERS 2 SET SEALS DOOR FINISH ADD ALTERNATE GENERAL NOTES 1. ALL PATIENT ROOM DOORS TO BE PROVIDED WITH THE FOLLOWING CONSTRUCTION IN LIEU OF WHAT IS SHOWN ON THE DOOR SCHEDULE: A. SCV DOOR CONSTRUCTION TO BE SCA (SOLID CORE WITH ACROVYN FINISH) B. WTF FINISH TO BE ACROVYN CHAMELEON "REGAL MAHOGANY" TYPE C TYPE CC TYPE D 9. FRAME DETAILS AND TYPE: SEE FRAME DETAILS AND TYPE ON SHEET A623 10. FIRE RATING: 20 M; 45 M; 60 M; 90 M; 120 M;180M 11. COMMENTS: 1. ALTERNATE DOOR FINISH TO BE PROVIDED SEE SPEC SECTION 012300 - ALTERNATE #1. 2. SOUND CONTROL DOORS. COORDINATE EXACT LOCATION WITH FINAL AHU SELECTION. 3. DOOR TO SWING 180 DEGREES. 4. PROVIDE ADJUSTABLE DOOR SWEEPS AT ISOLATION ROOM DOORS. 5. PROVIDE HOSPITAL PRIVACY LOCKSET IN LIEU OF PASSAGE LOCKSET. SEE SPEC SECTION 012300 - ALTERNATE #12. DOOR AND BORROWED LIGHT GENERAL NOTES 1. DOOR NUMBERING MAY NOT BE SEQUENTIAL. DOORS ARE NUMBERED TO MATCH THE ROOM NUMBERING. 2. ALL FRAMES SHALL BE CAULKED CONTINUOUSLY TO WALL. 3. WHEREVER THERE IS A CRACK LEFT BETWEEN THE BOTTOM OF DOOR FRAME AND THE FINISH FLOOR, THE CONTRACTOR SHALL PROVIDE CAULKING TO SEAL CRACK. 4. ALL THRESHOLDS SHALL CONFORM TO THE REQUIREMENTS OF THE MOST CURRENT EDITION OF ANSI Al 17.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES AND THE AMERICAN WITH DISABILITIES ACT. 5. NON -RATED DOORS MAY BE UNDERCUT ONE INCH MAXIMUM. DOORS IN RATED WALLS SHALL MEET THE REQUIREMENTS OF NFPA 80. 6. DOORS SCHEDULED TO HAVE A FIRE RATING LABEL SHALL HAVE A METAL LABEL PERMANENTLY AFFIXED TO BOTH THE DOOR AND FRAME. A VINYL LABEL AND EMBOSSED LABEL IN THE FRAME IS UNACCEPTABLE. 7. THE CONTRACTOR SHALL VERIFY THAT CLOSERS AND OTHER HARDWARE WILL ALLOW THE DOOR TO OPEN 180 DEGREES WHEN SUCH DOOR SWINGS ARE INDICATED ON THE FLOOR PLAN AND / OR THIS SCHEDULE. 8. ALL INTERIOR DOORS SHALL BE SOLID CORE, PRE - FINISHED UNLESS OTHERWISE NOTED IN THE SPECIFICATION. 9. DOORS SCHEDULED TO RECEIVE VIEW PANELS SHALL HAVE WOOD BEAD FRAME SURROUNDED IN SPECIES TO MATCH DOOR FINISH. FIRE RATED DOORS SHALL HAVE FIRE RATED WOOD BEAD. 10. ALL FRAMES SHALL BE 16 GAUGE, DOUBLE RABBETED AND PRIMED TO RECEIVE PAINT. HARDWARE GENERAL NOTES 1. HINGES DENOTED WITH AN * NEED DOOR PREP TO MATCH EXISTING DOOR FRAME. 2. ALL FIRE RATED OPENINGS SHALL HAVE U.L. LISTED BALL BEARING HINGES. 3. ALL INTERIOR DOORS WITH CLOSER SHALL HAVE CLOSERS ADJUSTED TO 5 LB MAXIMUM PULL FORCE. 4. ALL DOORS WITH CLOSERS SHALL HAVE KICK PLATES. 5. ALL HARDWARE IN RATED DOORS SHALL MEET THE REQUIREMENTS OF NFPA 80. FIRE RATED DOORS GENERAL NOTES 1. DOORS INDICATED TO BE 90 MIN B LABEL DOORS SHALL HAVE A MAXIMUM TRANSMITTED TEMPERATURE END POINT OF NOT MORE THAN 450 °F (250 °C) ABOVE AMBIENT AT THE END OF 30 MINUTES OF STANDARD FIRE TEST EXPOSURE. 2. DOORS INDICATED AS FIRE /SMOKE ARE TO MEET ALL REQUIREMENTS OF THE FIRE RATING INDICATED ABOVE AS WELL AS RESIST THE PASSAGE OF SMOKE AND BE LABELED AS SUCH. IN,R1�� CID- IDI UpP ��oF1C Flo N TER) oAM °v �pEA� � �� �xCE �apAttD AY a r c h i tec i s ARRAY- ,:".2CHITt.''rS.C*3.4 - 6800 Broken Sound Pkwy NW, Ste 125 Boca Raton, FL. 33487 o: 561- 995 -1700 f: 561 - 995 -1701 SEAL: firm license, #,AA26000880 Mark D. Taudien �R'� *$AR(5011821 -, CONSULTANTS: STRUCTURAL ENGINEER O'Donnell, Naccarato, Mignogna & Jackson 321 15th St., Suite 200 West Palm Beach, Florida 33401, USA Phone: 561.835.9994 Fax: 561.835.8255 MEP ENGINEER Smith, Seckman & Reid, Inc. 600 West Hillsboro Blvd, Suite 300 Deerfield Beach, FL 33441 Phone: 954.421.1260 Fax: 954.421.1466 --------------------------------------------------------------------------------- OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: PAVILION RENOVATIONS FLOORS 4 -7 6200 Southwest 73rd Street South Miami, FL 33143 7 xE oLnwuLE 10 -11 -13 6 u J 7 D u C OB -16 -13 5 Fire Dept Comments 07 -01 -13 n u u n Fire Dept Comments 06 -07 -13 3 PRICING SET TYPE D 9. FRAME DETAILS AND TYPE: SEE FRAME DETAILS AND TYPE ON SHEET A623 10. FIRE RATING: 20 M; 45 M; 60 M; 90 M; 120 M;180M 11. COMMENTS: 1. ALTERNATE DOOR FINISH TO BE PROVIDED SEE SPEC SECTION 012300 - ALTERNATE #1. 2. SOUND CONTROL DOORS. COORDINATE EXACT LOCATION WITH FINAL AHU SELECTION. 3. DOOR TO SWING 180 DEGREES. 4. PROVIDE ADJUSTABLE DOOR SWEEPS AT ISOLATION ROOM DOORS. 5. PROVIDE HOSPITAL PRIVACY LOCKSET IN LIEU OF PASSAGE LOCKSET. SEE SPEC SECTION 012300 - ALTERNATE #12. DOOR AND BORROWED LIGHT GENERAL NOTES 1. DOOR NUMBERING MAY NOT BE SEQUENTIAL. DOORS ARE NUMBERED TO MATCH THE ROOM NUMBERING. 2. ALL FRAMES SHALL BE CAULKED CONTINUOUSLY TO WALL. 3. WHEREVER THERE IS A CRACK LEFT BETWEEN THE BOTTOM OF DOOR FRAME AND THE FINISH FLOOR, THE CONTRACTOR SHALL PROVIDE CAULKING TO SEAL CRACK. 4. ALL THRESHOLDS SHALL CONFORM TO THE REQUIREMENTS OF THE MOST CURRENT EDITION OF ANSI Al 17.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES AND THE AMERICAN WITH DISABILITIES ACT. 5. NON -RATED DOORS MAY BE UNDERCUT ONE INCH MAXIMUM. DOORS IN RATED WALLS SHALL MEET THE REQUIREMENTS OF NFPA 80. 6. DOORS SCHEDULED TO HAVE A FIRE RATING LABEL SHALL HAVE A METAL LABEL PERMANENTLY AFFIXED TO BOTH THE DOOR AND FRAME. A VINYL LABEL AND EMBOSSED LABEL IN THE FRAME IS UNACCEPTABLE. 7. THE CONTRACTOR SHALL VERIFY THAT CLOSERS AND OTHER HARDWARE WILL ALLOW THE DOOR TO OPEN 180 DEGREES WHEN SUCH DOOR SWINGS ARE INDICATED ON THE FLOOR PLAN AND / OR THIS SCHEDULE. 8. ALL INTERIOR DOORS SHALL BE SOLID CORE, PRE - FINISHED UNLESS OTHERWISE NOTED IN THE SPECIFICATION. 9. DOORS SCHEDULED TO RECEIVE VIEW PANELS SHALL HAVE WOOD BEAD FRAME SURROUNDED IN SPECIES TO MATCH DOOR FINISH. FIRE RATED DOORS SHALL HAVE FIRE RATED WOOD BEAD. 10. ALL FRAMES SHALL BE 16 GAUGE, DOUBLE RABBETED AND PRIMED TO RECEIVE PAINT. HARDWARE GENERAL NOTES 1. HINGES DENOTED WITH AN * NEED DOOR PREP TO MATCH EXISTING DOOR FRAME. 2. ALL FIRE RATED OPENINGS SHALL HAVE U.L. LISTED BALL BEARING HINGES. 3. ALL INTERIOR DOORS WITH CLOSER SHALL HAVE CLOSERS ADJUSTED TO 5 LB MAXIMUM PULL FORCE. 4. ALL DOORS WITH CLOSERS SHALL HAVE KICK PLATES. 5. ALL HARDWARE IN RATED DOORS SHALL MEET THE REQUIREMENTS OF NFPA 80. FIRE RATED DOORS GENERAL NOTES 1. DOORS INDICATED TO BE 90 MIN B LABEL DOORS SHALL HAVE A MAXIMUM TRANSMITTED TEMPERATURE END POINT OF NOT MORE THAN 450 °F (250 °C) ABOVE AMBIENT AT THE END OF 30 MINUTES OF STANDARD FIRE TEST EXPOSURE. 2. DOORS INDICATED AS FIRE /SMOKE ARE TO MEET ALL REQUIREMENTS OF THE FIRE RATING INDICATED ABOVE AS WELL AS RESIST THE PASSAGE OF SMOKE AND BE LABELED AS SUCH. IN,R1�� CID- IDI UpP ��oF1C Flo N TER) oAM °v �pEA� � �� �xCE �apAttD AY a r c h i tec i s ARRAY- ,:".2CHITt.''rS.C*3.4 - 6800 Broken Sound Pkwy NW, Ste 125 Boca Raton, FL. 33487 o: 561- 995 -1700 f: 561 - 995 -1701 SEAL: firm license, #,AA26000880 Mark D. Taudien �R'� *$AR(5011821 -, CONSULTANTS: STRUCTURAL ENGINEER O'Donnell, Naccarato, Mignogna & Jackson 321 15th St., Suite 200 West Palm Beach, Florida 33401, USA Phone: 561.835.9994 Fax: 561.835.8255 MEP ENGINEER Smith, Seckman & Reid, Inc. 600 West Hillsboro Blvd, Suite 300 Deerfield Beach, FL 33441 Phone: 954.421.1260 Fax: 954.421.1466 --------------------------------------------------------------------------------- OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: PAVILION RENOVATIONS FLOORS 4 -7 6200 Southwest 73rd Street South Miami, FL 33143 7 Construction Set 10 -11 -13 6 Bldg Dept Comments OB -16 -13 5 Fire Dept Comments 07 -01 -13 4 Fire Dept Comments 06 -07 -13 3 PRICING SET 04 -10 -13 2 50% CONSTRUCTION SET 03 -11 -13 1 AHCA STAGE II 10 -17 -12 NO. DESCRIPTION DATE REVISIONS /ISSUES --------------------------------------------------------------------------------- SHEET TITLE: DOOR SCHEDULE -SIXTH FLOOR --------------------------------------------------------------------------------- DRAWN: EAS CHECKED: FB CON /REF No. AHCA 23/100154 -191 PROJECT No. 3593 DATE: 05/03/13 SCALE: As indicated SHEET NO. A703 This document is a copyright protected instrument of service, property of Array Architects and licensed for use in the title project only. Reproduction or use of this document without written permission of Array Architects is illegal and will be prosecuted under the law. © COPYRIGHT - 2013 ARRAY- ARCHITECTS, INC.