Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-781R-025
1 2 TYPICAL PATIENT ROOM WALL SECTION 11/2" =14" 5/8" GYPSUM WALL BOARD BEYOND _ qJ cV 5/8" GYPSUM WALLBOARD NEW INSULATION SSP -1; SILL CHAIR RAIL — NEW 20 GAUGE METAL STUD FRAMED BOXED OPENING NEW INSULATION EXISTING INSULATION i EXISTING PLASTER Y'1TS A] - ESS STEEL rE OVER FIRE WOOD kL METAL FRAMING EELINSERT (ER 5/8" TILE NOOD 3 4 2' -2" 1" STAINLESS STEEL FLUSH MOUNT CORNER GUARD 2„ 2" 1/2" STAINLESS STEEL RECESS Bulletin #131 -02 01 -15 -14 5/8" TYPE W HIGH ABUSE GYP BD. NO. cV DATE REVISIONS /ISSUES 1/2" STAINLESS STEEL RECESS EXISTING WALL 518" TYPE'X HIGH ABUSE GYP BD. NOTE: THIS DETAIL TYPICAL AT LOCATIONS SHOWN ON PLAN CD N ALTERNATE #14 - PROVIDE TRESPA WALL FINISH AT CORNER LOCATIONS PER SPEC SECTION 097700 AND DETAILS ON SHEET A627 n ENLARGED PLAN - WAYFINDING CORNERS 11/2" EXISTING PLAS EXISTING INSUI EXISTING STUC RADIUS EDGE TYPICAL PATIENT ROOM WALL SECTION 11/2" =14" V -81/2" DECORATIVE SHELVING PROVIDED BY MILLWORK CONTRACTOR 9 SAN AT ACCESSORY RECESS n SECTION (HORIZONTAL) AT ACCESSORY RECESS 1 —1/2"' =1' -0" �` 11/2" =1' -0" VALL BOARD INSULATION 14" CHANNEL INSULATION STING STUD 'AUGE STUD SSP -1: SILL PATIENT 0 i o i Z 0 o' w a c� z U) it W w U w Cn 0 w U U a w z Z 0 Q a w Cn Cn 5 a Z r� I 005 ' I PATIENT ROOM ACCESSORY RECESS I I 003 i I Al A61 002 I I I �I I I I I n TYPICAL PATIENT ROOM WALL SECTION 11/2" =1' -0" v v N(5TE: SEE C3/A625 F�{TYPICAL CD n ENLARGED PLAN - TYPICAL PATIENT ROOM WARDROBE — V, 1 Oil PLASTIC LAMINATE OVER FIRE RETARDENT PLYWOOD HARDWARE DH -2 ALL INTERIOR FACES 1/4" WHITE MELAMINE OVER FIRE RETARDENT PLYWOOD REMOVABLE SHELF; PROVIDE SECURE ATTACHMENT WITH SCREWS AND BLOCKING FLUSH 135 DEGREE 1" STAINLESS STEEL CORNER GUARD FLUSH 90 DEGREE 2" STAINLESS STEEL CORNER GUARD 4 F.M. PATIENT HEADWALL; PLASTIC LAMINATE' OVER FIRE RETARDENT PLYWOOD OVER NON- STRUCTURAL 3 5/8" METAL DETAI FRAMING @ 16" O.C. FIFTH FLOOR 47' -0" EXISTING EXTERIOR WALL I REMOVE EXISTING PLASTER FUR OUT AND PROVIDE NEW 518" TYPE X DENS ARMOR MR BOARD AT ALL EXTERIOR WALLS IN PATIENT ROOMS. PROVIDE MIN. 21/2" THERMAL RIGID INSULATION - = MOUNT BE EEN 2 /2 Z 1 FURRING n SECTION AT EXTERIOR WALL - ALTERNATE #4 EXISTING PLA ^"' NEW INSULAT 1/2" TILE OVEI 518" GYP. BD SCHEDULED BASE _ FOURTH FLOOR 35'-6" V SHOWER SIDE PLAN DETAIL AT EXISTING WALL @ PATIENT SHOWERS 6 1 1/2" = 1' -0" ATTACH NEW 3 5/8" FRAMING TO EXISTING FRAMING AND PROVIDE BLOCKING FOR GRAB BARS EXISTING FRAMING BLOCKING L. _ _a. _r c - h i t, a -c t s ARRAY- ARCHITECTS.COM 6800 Broken Sound Pkwy NW, Ste 125 Boca Raton, FL. 33487 o: 561 - 995 -1700 f: 561 - 995 -1701 SEAL: firm license #• AA26000880 P1 Mark D. Taudien AR0011821 .. CONSULTANTS: STRUCTURAL ENGINEER O'Donnell, Naccarato, Mignogna & Jackson 321 15th St., Suite 200 West Palm Beach, Florida 33401, USA Phone: 561.835.9994 Fax: 561.835.8255 MEP ENGINEER Smith, Seckman & Reid, Inc. 600 West Hillsboro Blvd, Suite 300 Deerfield Beach, FL 33441 Phone: 954.421.1260 Fax: 954.421.1466 --------------------------------------------------------------------------------- OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: PAVILION RENOVATIONS FLOORS 4 -7 6200 Southwest 73rd Street South Miami, FL 33143 2 Bulletin #81 -04 04 -23 -14 1 Bulletin #131 -02 01 -15 -14 NO. DESCRIPTION DATE REVISIONS /ISSUES SHEET TITLE: FRAMING DETAILS ��'Vi®�SQU1R� 0�11 ���RZ® a0 to p VvsA %o i S-0 A i DRAWN: Author CHECKED: Checker CON REF No. AHCA 23/100154 -191 PROJECT No. 3593 DATE: 05/03/13 SCALE: 1 1/2" = 1' -0" --------------------------------------------------------------------------------- SHEET NO. A617 This document is a copyright protected instrument of service, property of Array Architects and licensed for use in the title project only. Reproduction or use of this document without written permission of Array Architects is illegal and will be prosecuted under the law. ©COPYRIGHT - 2013 ARRAY- ARCHITECTS, INC.