Loading...
13-781R-004, E C L n3 L I M ns L c W U M u7 M i ro U O B w 0_ O U) ro L ro E L a� U) U 1 2 3 4 5 6 > R —SL DEMOLITION /ICRA PLAN - FIRST FLOOR 1/8" =1' -0" PARTIAL REFLECTED CEILING PLAN - FIRST FLOOR 1 /8" =1' -0" .. . ♦....VV Y V .. 7 PHASE 1: FIRST FLOOR ABOVE CEILING MECHANICAL WORK PHASING LEGEND KEYNOTES - ABOVE CEILING WORK Al COORDINATE ABOVE CEILING WORK IN THIS AREA WITH ONGOING CLINICAL EXPANSION PROJECT CM AND OWNER. OCOORDINATE RELOCATION OF FUNCTIONAL PROGRAMS IN THESES SPACES WITH OWNER. A3 REMOVE AND STORE EXISTING CEILINGS, FIXTURES, DIFFUSERS AND OTHER CEILING MOUNTED EQUIPMENT FOR REUSE WHERE POSSIBLE. COORDINATE WITH OWNER. REPLACE WHEN ABOVE CEILING WORK IS COMPLETE TO COORDINATE WITH EXISTING CONDITIONS AND NEW MECHANICAL WORK. (A4 ANY DAMAGE CAUSED BY ABOVE CEILING WORK AS NECESSARY IN THESE AREAS. A5 NOT USED 1 INTERIOR MODIFICATIONS ONLY (ANY EXTERIOR MODIFICATION MAY REQUIRE A BOARD APPEARANCE) PLAN NORTH - f -,A R RAY arc h i tec is A- kRAY- ARCHITECTS.COM 6800 Broken Sound Pkwy NW, Ste 125 Boca Raton, FL. 33487 o: 561 - 995 -1700 f: 561- 995 -1701 SEAL: firm license # AA26000880 � W � •i•` to II�y,�1 � �•�7 Mark D. Taudien A0011821 CONSULTANTS: STRUCTURAL ENGINEER O'Donnell, Naccarato, Mignogna & Jackson 321 15th St., Suite 200 West Palm Beach, Florida 33401, USA Phone: 561.835.9994 Fax: 561.835.8255 MEP ENGINEER Smith, Seckman & Reid, Inc. 600 West Hillsboro Blvd, Suite 300 Deerfield Beach, FL 33441 Phone: 954.421.1260 Fax: 954.421.1466 --------------------------------------------------------------------------------- OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: PAVILION RENOVATIONS FLOORS 4 -7 6200 Southwest 73rd Street South Miami, FL 33143 1 PHASING KEYNOTES P1 TEMPORARY FIRE RATED DOOR TO BE IN PLACE FOR DURATION OF CONSTRUCTION IN PHASE A OF EACH FLOOR. P2 TEMPORARY 1HR FIRE RATED PARTITION /BARRIER. SEE PARTITION TYPES DATE FOR CONSTRUCTION DETAIL AND SPECIFICATIONS. P3 CONSTRUCTION BARRIER CONSISTING OF VISQUEEN BARRIER OR ZIP DOOR TEMPORARY 1 HR FIRE RATED WALL IN FRONT OF PATIENT ELEVATORS TO P4 PROTECT PUBLIC SHOULD ELEVATOR OPEN ON THAT FLOOR. P5 ELEVATORS TO REMAIN OPERATIONAL TO ALL FLOORS DURING CONSTRUCTION. ps ELEVATORS TO REMAIN OPERATIONAL TO ALL FLOORS DURING CONSTRUCTION. COORDINATE WITH FACILITIES THE NEED FOR ONE OR TWO ELEVATORS. COORDINATE TEMPORARY PARTITIONS /BARRIERS WITH USER NEEDS. P7 MAINTAIN EGRESS VIA STAIR DURING ALL PHASES OF CONSTRUCTION. SCOPE OF WORK AT STAIR IS REPLACEMENT OF DOOR ONLY THAT SHOULD REQUIRE MIN. CONSTRUCTION TIME. DOORS FOR STAIR #2 AND STAIR #3 TO BE DONE AT DIFFERENT TIMES TO KEEP ONE STAIR OPEN AT ALL TIMES. A FIRE WATCH SHOULD BE INSTITUTED SHOULD THE TIME TO REPLACE THE DOOR EXCEED A FEW HOURS. ICRA KEYNOTES IC1 PROVIDE STICKY WALK OFF MAT, BOTH SIDES OF DOOR. IC2 SEAL PERIMETER OF EXISTING DOOR DURING CONSTRUCTION IN ADJACENT AREAS. IC3 PROVIDE ICRA CONTROL MEASURES PER HOSPITAL STANDARDS IN ABOVE CEILING WORK DURING CONSTRUCTION KEYNOTES - ABOVE CEILING WORK Al COORDINATE ABOVE CEILING WORK IN THIS AREA WITH ONGOING CLINICAL EXPANSION PROJECT CM AND OWNER. OCOORDINATE RELOCATION OF FUNCTIONAL PROGRAMS IN THESES SPACES WITH OWNER. A3 REMOVE AND STORE EXISTING CEILINGS, FIXTURES, DIFFUSERS AND OTHER CEILING MOUNTED EQUIPMENT FOR REUSE WHERE POSSIBLE. COORDINATE WITH OWNER. REPLACE WHEN ABOVE CEILING WORK IS COMPLETE TO COORDINATE WITH EXISTING CONDITIONS AND NEW MECHANICAL WORK. (A4 ANY DAMAGE CAUSED BY ABOVE CEILING WORK AS NECESSARY IN THESE AREAS. A5 NOT USED 1 INTERIOR MODIFICATIONS ONLY (ANY EXTERIOR MODIFICATION MAY REQUIRE A BOARD APPEARANCE) PLAN NORTH - f -,A R RAY arc h i tec is A- kRAY- ARCHITECTS.COM 6800 Broken Sound Pkwy NW, Ste 125 Boca Raton, FL. 33487 o: 561 - 995 -1700 f: 561- 995 -1701 SEAL: firm license # AA26000880 � W � •i•` to II�y,�1 � �•�7 Mark D. Taudien A0011821 CONSULTANTS: STRUCTURAL ENGINEER O'Donnell, Naccarato, Mignogna & Jackson 321 15th St., Suite 200 West Palm Beach, Florida 33401, USA Phone: 561.835.9994 Fax: 561.835.8255 MEP ENGINEER Smith, Seckman & Reid, Inc. 600 West Hillsboro Blvd, Suite 300 Deerfield Beach, FL 33441 Phone: 954.421.1260 Fax: 954.421.1466 --------------------------------------------------------------------------------- OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: PAVILION RENOVATIONS FLOORS 4 -7 6200 Southwest 73rd Street South Miami, FL 33143 1 Bulletin #81 -04 04 -23 -14 NO. DESCRIPTION DATE REVISIONS /ISSUES SHEET TITLE: DEMO /ICRA AND ARCHITECTURAL PLANS - FIRST FLOOR --------------------------------------------------------------------------------- DRAWN: KM CHECKED: FB CON /REF No. AHCA 23/100154 -191 PROJECT No. 3593 DATE: 05/03/13 SCALE: As indicated SHEET NO. A111 This document is a copyright protected instrument of service, property i of Array Architects and licensed for use in the title project only. Reproduction or use of this document without written permission of Array Architects is illegal and will be prosecuted under the law. © COPYRIGHT - 2013 ARRAY- ARCHITECTS, INC.