13-62R-007r --------------------------- � �✓ 1----------------------- - - - --1 1 1 I I 1 1 I 1 I I I 1 I 1 AHU -2 i 4 i AHLI-5 �4 I I I 1 I j 1 j 1 I 1 1 L.----- --- --- ------ ---- - - - - -J I I L-------------------------- J 3 4----- - - - - -I �—_AI- J-7 (DIA7) INSTALLED ABOVE -- AI -�J -10 (DIA8) INSTALLED BELLOW ( DEMOLITION WORK SCALE: 1/4"_-1'-0* - ENLARGED MECHANICAL ROOM - ELECTRICAL DEMOLITION NOTES: 1� EXISTING AHU -7 AND AHU -10 DISCONNECTS AND ASSOCIATED FEEDERS TO BE REMOVED. REMOVE CONDUIT AND WIRING BACK TO EXISTING PANEL SERVING UNITS AND LEAVE TWO BREAKERS AS "SPARE" FOR FUTURE USE BY OTHERS. 2. EXISTING CONTROL PANELS TO BE REMOVED. �3 EXISTING AHU -7 AND AHU -10 BELOW TO BE REMOVED. SEE MECHANICAL DRAWINGS. �4J EXISTING AHU -2 AND AHU -5 TO REMAIN. G5. EXISTING AHU -7 AND AHU -10 FIRE ALARM DUCT SMOKE DETECTORS TO BE REMOVED. NEW WORK SCALE: 1/4`­-1'-0* - ENLARGED MECHANICAL ROOM - ELECTRICAL NEW WORK NOTES: 10 NEW AHU-7A FEEDER TO RUN ABOVE CEILING UP TO EXISTING PANEL "1 EQHZ" LOCATED IN "ESSENTIAL LOADS" ELECTRICAL ROOM. ELECTRICAL CONTRACTOR TO COORDINATE EXACT ROUTING AT FIELD BASED ON EXISTING CONDITIONS. SEE PANEL SCHEDULE. �2 NEW VFD FOR AHU -7A TO BE PROVIDED. SEE MECHANICAL DRAWINGS. NEW AHU -7A TO REPLACE AHU -7 AND AHU -10. (4. NEW DDC CONTROL PANEL TO REPLACE EXISTING CONTROL SYSTEM. PROVIDE A NEW DUPLEX RECEPTACLE SERVED OUT OF EXISTING CONTROL SYSTEM PANEL TO SERVE NEW PANEL. COORDINATE EXACT LOCATION /CONDITIONS AT FIELD. �5 NEW DUCT DETECTORS TO BE PROVIDED IN COORDINATION WITH MECHANICAL CONTRACTOR FOR NEW AHU -7A. NEW DEVICES SHALL BE FULLY COMPATIBLE WITH EXISTING HOSPITAL FIRE ALARM SYSTEM. OPROVIDE NEW AHU SHUT -DOWN RELAY. (@2' 0 2' 4' SCALE: 1/4 " =1' -0" SOUTH MIAMI HOSPITAL SUNSET CAFE CAFETERIA RENOVATION 6200 S.W. 73rd STREET MIAMI, FL 33143 o.Mr General Contractor ARCHITECTURE PLANNING LEDA DALE INTERIO SBNG 0 EST. 1915 3390 Mary Street, Suite 216 Miami Florida 33133 USA T: 305.461.9480 F: 305.461.3686 Architect Associate Architect PROJ. No. 22016 CA 924 LOUIS J. AGURRE & ASSOCIATES P.A. CONSULTING ENGINEERS 9150 SOUTH DADELAND BLVD. SUITE 900 MIAMI, FLORIDA 33156 TELEPHONE: (305) 670 -0141 FAX: (305) 670 -0144 www.ljaapo.com N CAFETERIA Not to Scale 061 -10064 -020 Architects Project Number FOR PERMIT 11/13/2012 Drawing Issue REVISIONS NO. DESCRIPTION DATE 2 AHU REPLACEMENT 01.10.13 LEO A DALY COMPANY Copyright 2012 t � ELEC'TEI l t t t E9 , MARIO D. PAZOS "P.E': e` LICENSE u 52078 Seal ENLARGED MECHANICAL ROOM ELECTRICAL Sheet Title ■ 2 Sheet Numb