13-62-037E3.03 SCALE: 316'1 =1' -0" SCALE: 3/16 " =1' -0" NEW WORK POWER PLAN NOTES: OREMOVE AND EXTEND EXISTING CATV OUTLET, WIRING AND CONDUIT OVER TO NEW TV MONITOR LOCATION. COORDINATE EXACT LOCATION OF POWER AND CATV OUTLET WITH FURNISHED EQUIPMENT AND ARCHITECTURAL DRAWINGS SO THAT DEVICES ARE LOCATED BEHIND EQUIPMENT, OUT OF VIEW. OALL EXISTING RECEPTACLE LOCATIONS REUSED BY NEW WORK SHALL BE PROVIDED WITH NEW DEVICES AND COVER PLATES TO MATCH BALANCE OF INSTALLATION. OUNLESS OTHERWISE NOTED, THIS PROJECT REQUIRES THE CONTRACTOR TO REUSE EXISTING CIRCUITS LEFT "SPARE" BY DEMOLITION TO SERVE NEW EQUIPMENT. OALL SERVING LINE EQUIPMENT POWER SHALL BE RUN IN TRENCHES UP TO SERVING LINE EQUIPMENT, CONCEALED FOR A CLEAN INSTALLATION. REFER TO KITCHEN EQUIPMENT CONSULTANT'S LAYOUT AND DRAWINGS / SCHEDULES FOR EXACT LOCATION AND TYPE OF OUTLETS. OELECTRICAL CONTRACTOR SHALL COORDINATE FURNISHED EQUIPMENT POWER REQUIREMENTS WITH INFORMATION ON DRAWINGS PRIOR TO ROUGH -IN AND PROVIDE AS NECESSARY. i OEXISTING FIRE ALARM SYSTEM DEVICES SHALL BE CLEANED, TESTED AND REUSED WHERE NECESSARY IN NEW INSTALLATION OR PROVIDE NEW. OEXISTING CCTV CAMERA LOCATIONS TO REMAIN. CAREFULLY CLEAN CAMERAS AND REINSTALL IN NEW WALLS AND CEILINGS AT EXISTING CAMERA LOCATIONS AS NECESSARY. OPROVIDE NEW UPDATED PANEL DIRECTORIES AT END OF PROJECT FOR ALL PANELS INVOLVED IN THIS REMODEL PROJECT. OALL CONDUITS AND WIRING LEFT UNUSED BY THIS PROJECT SHALL BE REMOVED AND NOT ABANDONED IN CEILING SPACES. 0 EXISTING / RELOCATED OR NEW FIRE ALARM DEVICES SHALL BE FULLY COMPATIBLE WITH EXISTING FIRE ALARM SYSTEM. FINAL DEVICE LOCATIONS SHALL BE COORDINATED WITH ARCHITECTURAL FEATURES AND ELEVATIONS. 11. CONTRACTOR IS TO SEAL (SMOKE PROOF) ALL ELECTRICAL SYSTEMS PENETRATIONS ABOVE CEILING USING APPROVED SEALANTS FOR A COMPLETE SMOKE PROOF COMPARTMENT. REFER TO ARCHITECTURAL DRAWINGS FOR EXTENT OF SMOKE BARRIER. _7�_ SOUTH MIAMI HOSPITAL SUNSET CAFE CAFETERIA RENOVATION 6200 S.W. 73rd STREET MIAMI, FL 33143 Owner General Contractor LED ANV ENTNNFERSIT �zE EST. 1915 3390 Mary Su-eel, Suite 210 Miami Florida 331;33 USA T: 305.461 .9480 F: 305.461 .36136 Architect Associate Architect PROD. No. 22016 CA 924 LOUIS J. AGUIRRE & ASSOCIATES P.A. CONSULTING ENGINEERS 9150 SOUTH DADELAND REVD. SUITE 900 MIAMI, FLORIDA 33156 TELEPHONE: (305) 670 -0141 FAX: (305) 670 -0144 WWW.1)oapo'corn N CAFETERIA Not to Scale 061 -10064 -020 Architects Projech Number FOR PERMIT 11/13/2012 Drawing Issue REVISIONS NO, DESCRIPrION DATE LEO A DALY COMPANY Copyright 2012 N, "W" rCv ,r['3� C,J�by L�CT�ICAL: MA�10 D. PAZOS P.E. LICENSE ti 52078 seal POWER AND SYSTEM PLAN ELECTRICAL Sheet 'r isle E3.03 Sheet Number