13-62-028PLUMBING ABBREVIATIONS
A/E
ARCHITECT /ENGINEER
ID
INSIDE DIAMETER
AC
AIR CONDITIONING
IND
INDIRECT
AD
AREA DRAIN
INV
INVERT
AFC
ABOVE FINISHED CEILING
ISO
ISOMETRIC
AFF
ABOVE FINISHED FLOOR
W
INDIRECT WASTE /INDUSTRIAL WASTE
AFG
ABOVE FINISHED GRADE
IWH
INSTANTANEOUS WATER HEATER
AG
ABOVE GROUND
VALVE IN VERTICAL
WCO WCO O--i
AHU
AIR HANDLING UNIT
KIT
KITCHEN
AP
ACCESS PANEL
KPA
KILOPASCAL
APPROX
APPROXIMATE
KW
KILOWATT
APT
APARTMENT
WATER HAMMER ARRESTOR
L VTR
AR
ACID RESISTANT
LAV
LAVATORY
ASME
AMERICAN SOCIETY OF MECHANICAL
FLOOR DRRAIN WITH TRAP
RESEAL
ENGINEERS
MECH
MECHANICAL
ASTM
AMERICAN SOCIETY FOR TESTING AND
MH
MANHOLE
TEMPORARY OR PERMANENT CAP
MATERIALS
MIN
MINIMUM /MINUTE
AV
ACID VENT
MOD
MODEL
AW
ACID WASTE
MTD
MOUNTED
AWS
AMERICAN WELDING SOCIETY
FAX: (305) 670 -0144
AWWA
AMERICAN WATER WORKS ASSOCIATION
NA, N/A
NOT APPLICABLE
NC
NORMALLY CLOSED
BLDG
BUILDING
NO
NORMALLY OPEN
BOT
BOTTOM
NIC
NOT IN CONTRACT
BT
BATHTUB
NPS
NATIONAL PIPE STANDARD
11/13/2012
NTS
NOT TO SCALE
CA
COMPRESSED AIR
REVISIONS
CB
CATCH BASIN
OD
OUTSIDE DIAMETER
CHKV
CHECK VALVE
OFD
OVERFLOW DRAIN
CI
CAST IRON
OS & Y
OUTSIDE SCREW AND YOKE
CIP
CAST IRON PIPE /CAST -IN -PLACE
CO
CLEANOUT
PD
PLANTER DRAIN
COND
CONDENSATE
P &T
PRESSURE & TEMPERATURE
CONN
CONNECTION
PKD
PARKING DRAIN
CONT
CONTINUOUS /CONTINUATION
PLUM
PLUMBING
CPVC
CHLORINATED POLYVINYL CHLORIDE
PRV
PRESSURE REDUCING VALVE
CW
COLD WATER
PSIG
POUNDS PER SQUARE INCH, GAGE
PVC
POLYVINYL CHLORIDE
DET
DETAIL
PVDF
POLYVINYLIDINE FLUORIDE
DF
DRINKING FOUNTAIN
EDUARDO A, SUAREZ, P.E.
DIA
DIAMETER
R
RADIUS, RADII, RELIEF PIPE
DIM
DIMENSION
RD
ROOF DRAIN
DN
DOWN
REINF
REINFORCEMENT
DOM
DOMESTIC
REQ'D
REQUIRED
DR
DRAIN
RM
ROOM
DS
DOWNSPOUT
RPM
REVOLUTIONS PER MINUTE
DW
DISHWASHER
RWL
RAIN WATER LEADER
DWG
DRAWING
SAN
SANITARY
EA
EACH
SCH
SCHEDULE
EL
ELEVATION
SD
STORM DRAIN
ELEC
ELECTRICAL
SECT
SECTION
EMER
EMERGENCY
SF
SQUAREFEET
EPDM
ETHYLENE PROPYLENE DIENE MONOMER
SHR
SHOWER
EO
EMERGENCY OVERFLOW
SHT
SHEET
EQUIP
EQUIPMENT
SPECS
SPECIFICATIONS
EWC
ELECTRICAL WATER COOLER
SS
STAINLESS STEEL /SANITARY SEWER
EWH
ELECTRICAL WATER HEATER
SSK
SERVICE SINK
EXIST
EXISTING
TD
TRENCH DRAIN
FCO
FLOOR CLEANOUT
TDH
TOTAL DYNAMIC HEAD
FD
FLOOR DRAIN
TEMP
TEMPERATURE
FF
FINISHED FLOOR
TOP
TOP OF PIPE
FIN
FINISH
TYP
TYPICAL
FLR
FLOOR, FLOORING
FM
FACTORY MUTUAL /FORCE MAIN
UG
UNDERGROUND
FO
FUEL OIL
UL
UNDERWRITERS LABORATORIES
FOR
FUEL OIL RETURN
UON
UNLESS OTHERWISE NOTED
FOS
FUEL OIL SUPPLY
UR
URINAL
FS
FLOOR SINK
FT
FEET /FOOT
V
VENT
FU
FIXTURE UNIT
VAC
VACUUM
FUT
FUTURE
VB
VACUUM BREAKER
VIV
VALVE IN VERTICAL
G
GAS
VTR
VENT THRU ROOF
GA
GAGE
VS
VENT STACK
GAL
GALLON
GALV
GALVANIZED
W/
WITH
GC
GENERAL CONTRACTOR
WC
WATER CLOSET
GPD
GALLONS PER DAY
WCO
WALL CLEANOUT
GPH
GALLONS PER HOUR
W/0
WITHOUT
GPM
GALLONS PER MINUTE
GV
GATE VALVE
GW
GREASY WASTE
H &CW
HOT AND COLD WATER
HB
HOSE BIBB
HD
HEAD
HD
HUB DRAIN
HP
HORSE POWER
HR
HOUR
HW
HOT WATER
PLUMBING LEGEND
SYMBOL
DESCRIPTION
SANITARY PIPE
RWL
RAIN WATER LEADER
SD
STORM DRAIN
____________
VENT PIPE
- -
DOMESTiIC COLD WATER PIPE
DOMESTIC HOT WATER PIPE
---
DOMESTIC HOT WATER RETURN PIPE
CD
CONDENSATE DRAIN PIPE
PT
PRESSURE TEMP RELIEF PIPE
PD
PAN DRAIN PIPE
so
DIRECTION OF FLOW
VALVE IN VERTICAL
WCO WCO O--i
WALL CLEAN -OUT
FCO
FLOOR CLEAN -OUT
GATE VALVE
-- -{�F --
BALL VALVE
ES -r. 1915
CHECK VALVE
HOSE BIBS
[}- C
WATER HAMMER ARRESTOR
L VTR
VENT THRU ROOF
i
LJ ®
FLOOR DRAIN, AREA DRAIN OR ROOF
Architect
DRAIN WII,TH FULL GRATE
FLOOR DRRAIN WITH TRAP
RESEAL
PRESSURE AND TEMPERATURE', RELIEF VALVE
CONNECT NEW TO EXISTING SYSTEMS
DEMOLITION TERMINATION POINT
C
TEMPORARY OR PERMANENT CAP
/thffhf�fhthf
EXISTING''LINE TO BE
REMOVED
I APPLICABLE CODES'/ STANDARDS I
APPLICABLE CODES AND STANDARDS SHALL INCLUDE ALL STATE LAWS, LOCAL
ORDINANCES, UTILITY COMPANY REGULATIONS AND THE APPLICABLE
REQUIREMENTS OF THE FOLLOWING ACCEPTED CODES AND STANDARDS, WITHOUT
LIMITING THE NUMBER, AS FOLLOWS:
1. FLORIDA BUILDING CODE - 2010
2. GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH DEPARTMENT CARE
FACILITIES 2010
3. AGENCY FOR HEALTH CARE ADMINISTRATION, AHCA, 59A -3.
4. NATIONAL ELECTRIC CODE (NEC 2008).
5. ENVIRONMENTAL PROTECTION AGENCY (EPA).
6. DEPARTMENT OF ENVIRONMENTAL REGULATION MANAGEMENT (DERM).
7. LOCAL ORDINANCES, REGULATIONS OF THE BUILDING DEPARTMENTS AND FIRE
DEPARTMENTS.
8. NATIONAL ELECTRICAL SAFETY CODE 2002. I
9. OCCUPATIONAL SAFETY AND HEALTH STANDARD.
10. RECOMMENDATION OF NFPA, IN GENERAL AND IN PARTICULAR:
A. LIFE SAFETY, NFPA (2009)
B. HAVC, NFPA 90A (2009)
C. HVAC, NFPA 90B (2009)
D. HVAC, NFPA 96 (2008)
E. HOSPITALS, NFPA 99 (2005)
F. SMOKE CONTROL, NFPA 92A (2009), 92B (200 9)
G. MEDICAL GAS, NFPA 99 (2005)
H. STANDARD FOR INSTALLATION OF EXHAUST SYSTEMS, NFPA 91 (2004)
I. STANDARD FOR INSTALLATION OF SPRINKLER SYSTEM, NFPA 13 (2007)
11. RECOMMENDATION OF ASHRAE (2001), INCLUDING ASHRAE 90 -75.
12. JOINT COMMISSIONS FIRE ALARM POLICY.
13. FLORIDA WITH DISABILITIES ACCESSIBILITY ACT (2004).
14. SMACNA (2005).
PLUMBING GENERAL NOTES:
1. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE FLORIDA
BUILDING CODE 2010 AND ALL APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES.
2, THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY
FOR THE COMPLETE INSTALLATION OF THE PLUMBING SYSTEMS, ALL IN ACCORDANCE
WITH THESE CONSTRUCTION DOCUMENTS.
3. THE CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE OF THE WORK AND BECOMING
FAMILIAR WITH THE CONDITIONS OF THE WORK PRIOR TO SUBMITTING A BID. THE
CONTRACTOR IS REQUIRED TO BECOME FAMILIAR WITH ALL THE CONTRACT DOCUMENTS
PERTAINING TO THE PROPOSED WORK. THE SUBMISSION OF A BID SHALL BE SUFFICIENT
TO ESTABLISH THAT THE CONTRACTOR HAS INVESTIGATED THE SITE OF THE WORK AND IS
SATISFIED AS TO ALL REASONABLE CONDITIONS TO BE ENCOUNTERED, THE WORK TO BE
PERFORMED AND THE MATERIALS TO BE PROVIDED IN THE COMPLETION OF THE PROJECT.
4. FAILURE OF BIDDERS TO MAKE REQUIRED VISITATIONS AND /OR INVESTIGATIONS TO
INFORM THEMSELVES FULLY OF EXISTING CONDITIONS, AND TO INCLUDE IN THEIR
PROPOSALS A SUM SUFFICIENT TO COVER ALL POSSIBLE FIELD CONDITIONS, WILL NOT IN
ANY WAY ENTITLE THEM TO ANY EXTRA CHARGES OVER AND ABOVE THEIR ORIGINAL
PROPOSALS,
5. IT IS THE INTENT OF THE PLANS AND GENERAL NOTES TO PROVIDE A COMPLETE AND
OPERATING INSTALLATION INCLUDING ALL NECESSARY ITEMS REQUIRED, EVEN THOUGH
ITEMS ARE NOT INDICATED ON THE DRAWINGS OR IN THE NOTES. ALL WORK CONSIDERED
NECESSARY FOR THE COMPLETION OF THE WORK IN PROPER MANNER NOT SHOWN ON
THE PLANS OR NOTES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN
WRITING PRIOR TO BIDS OTHERWISE WORK SHALL NOT BE ADDITIONALLY CHARGED
AFTER BID IS AWARDED.
6. UPON COMPLETION, CONTRACTOR SHALL CLEAN ALL DUST AND DEBRIS IN AREAS WHERE
WORK WAS CONDUCTED.
7. ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES AT JOB SITE PRIOR TO
FABRICATION AND INSTALLATION OF EQUIPMENT.
8. THE WORK THAT IS TO BE DONE UNDER THIS CONTRACT INCLUDES THE FURNISHING OF
ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE COMPLETION OF THE
SYSTEMS SHOWN ON DRAWINGS.
9, THE DRAWINGS ARE GENERALLY DIAGRAMMATIC. THEY DO NOT SHOW EVERY BEND,
OFFSET, ELBOW OR OTHER FITTINGS WHICH MAY BE REQUIRED FOR THE INSTALLATION IN
THE SPACE ALLOCATED.
10. DRAWINGS ARE NOT TO BE SCALED, UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE
ARCHITECTURAL AND /OR SITE CONDITIONS SHALL GOVERN EXACT LOCATION OF PIPING
AND EQUIPMENT TO BE INSTALLED.
11. ALL MATERIALS AND EQUIPMENTS SHALL BE NEW AND OF GOOD QUALITY OF RESPECTIVE
KIND AND GRADE AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE
PROGRESS OF THE WORK. ALL WORK THROUGHOUT SHALL BE PERFORMED IN A
WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN.
12. FOR EXACT LOCATION OF ALL PLUMBING FIXTURES, SEE ARCHITECTURAL DRAWINGS. DO
NOT ROUGH -IN ANY PLUMBING FIXTURE AND /OR EQUIPMENT WITHOUT AN APPROVED
COPY OF THE CORRESPONDING SHOP DRAWINGS.
INFECTION CONTROL NOTE
CONTRACTOR SHALL OBTAIN A COPY OF THE INFECTION CONTROL RISK ASSESMENT FOR THIS
PROJECT. ALL WORK SHALL BE IN COMPLIANCE WITH THE REPORT. ALL WORK OUTSIDE THE SCOPE
OF WORK AREA REQUIRED FOR THIS PROJECT, SHALL BE COORDINATED WITH OWNER AND BE IN
COMPLIANCE WITH THE ICRA REPORT AND BE SUPERVISED BY THE OWNER'S REPRESENTATIVE.
I
BID NOTE
THE DRAWINGS DO NOT INDICATE EXISTING INSTALLATIONS OTHER THAN TO IDENTIFY
MODIFICATIONS OR EXTENSIONS THERETO. VISIT THE SITE AND ASCERTAIN THE EXISTING
CONDITIONS. REVIEW CONSTRUCTION DETAILS OF THE EXISTING PORTION OF THE BUILDING DURING
THE SITE INSPECTION. INCLUDE ALL WORK REQUIRED TO REMOVE OR MODIFY PORTIONS OF THE
EXISTING INSTALLATION IN ORDER TO ACCOMMODATE THE NEW WORK . FAILURE TO COMPLY WITH
THIS WILL NOT BE CONSIDERED GROUNDS FOR ADDITIONAL PAYMENT IN CONNECTION WITH
REMOVING OR MODIFYING ANY PART OF THE EXISTING INSTALLATION OR INSTALLING ANY NEW OR
TEMPORARY WORK.
COORDINATION DRAWINGS
1, THE CONTRACTOR SHALL SUBMIT COORDINATION DRAWINGS TO ARCH./ENG AND OWNER'S
PROJECT MANAGER FOR APPROVAL PRIOR TO ANY FABRICATION AND INSTALLATION.
2. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL NEW PIPING, DUCTWORK,
CONDUIT -S, ECT. WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL
SYSTEMS OF THE BUILDING. VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOBSITE
PRIOR TO FABRICATION AND INSTALLATION OF EQUIPMENT AND MATERIALS. ANY CONFLICTS
SHALL BE REPORTED IMMEDIATELY TO THE ARCHITECT /ENGINEER PRIOR TO BEGINNING OF
CONSTRUCTION.
COORDINATION NOTE
AS PART OF THIS CONTRACT, THE SUB - CONTRACTOR AND THE CONTRACTOR ARE RESPONSIBLE FOR
COORDINATION AND VERIFICATION THAT ALL EQUIPMENT, SHOWN IN THE ARCHITECTURAL DRAWINGS
PARTICULARLY, BUT NOT LIMITED TO THE ARCHITECTURAL EQUIPMENT PLAN, INCLUDE ALL
SERVICE /UTILITY REQUIRED TO OPERATE THE EQUIPMENT SHOWN. ANY DISCREPANCIES ARE TO BE
POINTED OUT DURING THE BIDDING PROCESS,
DISCREPANCIES NOT POINTED OUT DURING THE BIDDING PROCESS WILL BE RESOLVED BY THE
CONTRACTOR AS PER THE ARCHITECT DETAILS AT NO ADDITIONAL COST TO THE OWNER.
GENERAL NOTE:
AS PART OF THIS CONTRACT, THE SUB - CONTRACTOR AND THE CONTRACTOR ARE RESPONSIBLE FOR
COORDINATION AND VERIFICATION THAT ALL EQUIPMENT, SHOWN IN THE ARCHITECTURAL DRAWINGS
PARTICULARLY, BUT NOT LIMITED TO THE ARCHITECTURAL EQUIPMENT PLAN, INCLUDE ALL
SERVICE /UTILITY REQUIRED TO OPERATE THE EQUIPMENT SHOWN. ANY DISCREPANCIES ARE TO BE
POINTED OUT DURING THE BIDDING PROCESS.
DISCREPANCIES NOT POINTED OUT DURING THE BIDDING PROCESS WILL BE RESOLVED BY THE
CONTRACTOR AS PER THE ARCHITECT DETAILS AT NO ADDITIONAL COST TO THE OWNER.
PLUMBING DEMOLITION NOTES:
1. SITE INVESTIGATION:
THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE LOCATION
OF ALL EXISTING UTILITIES STUB -OUTS, PIPING, EQUIPMENT, ETC., AND /OR ANY
CONDITION THAT MAY AFFECT HIS WORK. ALL THE NECESSARY RE- `OUTING,
RELOCATING AND /OR REMOVAL OF EXISTING PIPING, EQUIPMENT, ETC., SHA -L BE
INCLUDED IN THE SCOPE OF WORK. IGNORANCE ON THE PART OF THE CONTRACTOR
WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITIES ASSUMED
UNDER THIS CONTRACT.
2. THE NATURE OF THE REMODEL TYPE CONSTRUCTION POSES SPECIAL PROBLEMS FOR
THE DESIGNER ENGINEERS AS WELL AS THE PLUMBING CONTRACTOR. EVERY EFFORT
HAS BEEN MADE BY THE ENGINEERS TO SHOW AND VERIFY, WHERE POSSIBLE, THE
LOCATION OF THE EXISTING PLUMBING SYSTEMS. THE MAJOR PORTION OF THE
PLUMBING SYSTEMS ARE AS SHOWN ON THE DRAWINGS: HOWEVER MINOR DEVIATIONS
MAY BECOME EVIDENT AS THE JOB PROGRESSES. NO ADVANTAGE IS TO BE TAKEN BY
THE PLUMBING CONTRACTOR BECAUSE THESE MINOR DIFFERENCES. THE PLUMBING
CONTRACTOR SHALL PERFORM A FIELD VERIFICATION BEFORE BIDDING THIS PROJECT.
3. CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING HIS DEMOLITION WORK WITH
OTHER TRADES, AND TO PROTECT FROM DAMAGE EXISTING PIPES USED FOR FUTURE
CONNECTIONS.
4. EXISTING PIPES SERVING AREAS REMAINING IN SERVICE AT THIS TIME SHALL NOT BE
INTERRUPTED UNLESS A TEMPORARY INTERRUPTION IS COORDINATED WITH THE
OWNER.
5. ALL SERVICE INTERRUPTIONS SHALL BE SCHEDULED WITH THE AUTHORIZED
REPRESENTATIVE OF THE OWNER. ALL REMOVAL AND DISPOSAL WORK SHALL BE
COORDINATED WITH THE AUTHORIZED REPRESENTATIVE OF THE OWNER.
6. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT PROPERTY IN
AREAS WHERE WORK IS BEING CONDUCTED. THE CONTRACTOR IS RESPONSIBLE FOR
ANY DAMAGES CAUSED TO BUILDING COMPONENTS DUE TO WORK OPERATIONS. PATCH
AND REPAIR EXISTING SURFACES DAMAGED AS REQUIRED TO MATCH ADJACENT
SURFACES.
7. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ALL EXISTING CONSTRUCTION,
INCLUDING EXISTING TO REMAIN AND TO BE REMOVED. ITEMS AND DEBRIS TO BE
REMOVED WILL BE PROPERLY DISPOSED OF BY THE CONTRACTOR, WITHIN HIS
CONTRACT, AT NO COST TO THE OWNER,
8. ANY UTILITY LINES TO REMAIN AND THAT ARE BROKEN OR DAMAGED DURING
DEMOLITION OPERATIONS SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL
CHARGE TO THE CONTRACT PRICE, OR SHALL BE REPAIRED BY THE OWNER AT THE
CONTRACTOR'S EXPENSE.
9. ANY DISCREPANCIES BETWEEN THE WORK DEPICTED ON THESE DOCUMENTS AND THE
ACTUAL CONDITIONS ENCOUNTERED SHALL BE BROUGHT PROMPTLY TO THE ENGINEER
FOR REVIEW AND CLARIFICATION.
10. ANY DAMAGED EQUIPMENT SHALL BE REPLACED OR RESTORED TO ORIGINAL CONDITION
PLUMBING SPECIFICATIONS:
SANITARY WASTE AND VENT PIPING
A. ALL HORIZONTAL BRANCHES, SEWER AND DRAIN LINES SHALL BE SLOPED A MINIMUM OF
1/8 INCH PER FOOT UNLESS OTHERWISE INDICATED ON PLANS.
B. EVERY FIXTURE CONNECTED TO THE DRAINAGE SYSTEM SHALL BE EQUIPPED WITH A
WATER SEAL TRAP.
C. VENT STACKS SHALL NOT PASS THROUGH ROOF AT VALLEYS, ROOF CRICKETS, IN FRONT
OF WINDOWS OR WITHIN 6-0" OF ROOF EDGE.
D. MATERIALS SHALL BE AS FOLLOWS:
1) DRAINAGE AND VENT PIPING (ABOVE GRADE): SHALL BE HUBLESS SERVICE WEIGHT
CAST IRON WITH NEOPRENE GASKETS AND STAINLESS STEEL BAND JOINTS.
DOMESTIC COLD AND HOT WATER PIPING
A. PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS ARE JOINED.
B. ESCUTCHEONS SHALL BE CHROME PLATED BRASS WITH LOCKING SCREWS WHERE PIPES
PASS THROUGH FINISHED WALLS,
C. PROVIDE PIPING AS FOLLOWS:
1) WATER PIPING (ABOVE GRADE): SHALL BE COPPER TYPE "L" ASTM B -88 WITH WROUGHT
COPPER FITTINGS AND 95 -5 SOLDERED JOINTS. COPPER TYPE "K" ASTM B -88 UNDER
GROUND.
2) PRESSURE AND TEMPERATURE RELIEF LINES: SHALL BE TYPE "M" COPPER WITH
WROUGHT COPPER FITTINGS AND 95 -5 SOLDERED JOINTS.
D. ALL EXPOSED PIPING WITHIN TOILET ROOMS SHALL BE CHROME PLATED.
A. PROVIDE CONTROL VALVES WHERE NOTED ON PLANS, AND AS REQUIRED FOR COMPLETE
REGULATION OR CONTROL OF ALL SYSTEM MAINS, BRANCHES TO GROUP OF FIXTURES,
AND TO EACH PIECE OF EQUIPMENT.
B. PROVIDE ACCESS PANELS AS REQUIRED TO VALVES, OR GROUP OF VALVES, WHERE
CONCEALED AND FOR PROPER MAINTENANCE AND OPERATION OF SYSTEM.
C. GATE VALVES:
1) 2 -1/2 INCHES AND SMALLER SHALL BE BRONZE BODY, SCREWED BONNET, NON - RISING
STEM, SOLID WEDGE, CLASS 125,200 PSI NON -SHOCK WATER; THREADED END WATTS
WGV- SERIES, SOLDERED END WATTS WGVS- SERIES.
INSULATION
A. INSULATION SHALL RUN CONTINUOUS THROUGH WALLS, FLOORS AND CEILINGS.
B. WHERE INSULATION PASSES THROUGH HANGERS IT SHALL BE PROVIDED WITH A
PROTECTION SHIELD, 180 DEGREE ARC GALVANIZED SHEET METAL COVERING 12 INCHES
LONG.
C. ALL A/C CONDENSATE DRAIN LINES ABOVE GRADE SHALL BE INSULATED WITH 1/2"
ARMAFLEX PIPE INSULATION. SEAL ALL SEAMS WITH INSULATION MANUFACTURER'S
SOLVENT. NO TAPES ARE ALLOWED.
D. DOMESTIC HOT WATER SUPPLY AND RETURN PIPING: 1/2 INCH THICK GLASS FIBER
MOLDED INSULATION WITH PRE -SIZED FACTORY APPLIED FIRE RATED JACKET OF GLASS
CLOTH WITH LONGITUDINAL LAP AND BUTT JOINT STRIPS WITH SELF - SEALING ADHESIVE.
TESTING
A. COMPLETE WATER PIPING SYSTEM SHALL BE PRESSURE TESTED BY CAPPING OR
PLUGGING OPENINGS, FILLING SYSTEM WITH WATER AND APPLYING HYDROSTATIC
PRESSURE OF 125 PSI FOR PERIOD OF NOT LESS THAN 2 HOURS.
B. SOIL, WASTE AND VENT PIPING SHALL BE TESTED BY CAPPING THE ENDS OF THE SYSTEM
AND ALL LINES FILLED WITH WATER TO HIGHEST POINT AND ALLOW TO STAND UNTIL
INSPECTION IS MADE AND WATER LEVEL REMAINS CONSTANT.
SOUTH MIAMI HOSPITAL
SUNSET CAFE
CAFETERIA RENOVATION
6200 S.W. 73rd STREET
MIAMI, FL 33143
Owner
General Contractor
R C H I r E (: ERIEOERSTN�ZE
LEDADAL EN LAN N I N G
ES -r. 1915
3.390 Mary Street, Suite 216
Miami Florida 33133 USA
1: 305.46-1.9480 F: 305.461-3686
Architect
Associate Architect
PROJ. No. 22016 CA 924
LOUIS A AGUIRRE & ASSOCIATES P.A.
CONSULTING ENGINEERS
9150 SOUTH DADELAND BLVD. SUITE 900
MIAMI, FLORIDA 33156
TELEPHONE: (305) 670 -0141
FAX: (305) 670 -0144
www.ljaapa.com
N
CAFETERIA
Nut to Scale
061 -10064 -020
Architects Project NUmber
FOR PERMIT
11/13/2012
Thawing Issue
REVISIONS
NO,
DESCRIPTION
DATE
LEO A DALY COMPANY Copyright 2012
P t
rjzr t �, v
r}"0,
Cfa
MECHANICAL:
EDUARDO A, SUAREZ, P.E.
seal
LICENSE n 64759
GENERAL NOTES AND
SYMBOL LEGEND
PLUMBING
Sheet
Title
PO,00
I I Sheet
Ne17 b r