13-62-025FLOOR PLAN SCALE: 3/16 " =1' -0" - HVAC NEW WORK NEW WORK KEY NOTES: 10 EXISTING AHU'S # 7 (D1A7) AND 10 (D1A8) LOCATED IN MECHANICAL /ELECTRICAL ROOM, SHALL BE REFURBISHED. BOTH UNITS SHALL BE THOROUGHLY CHECKED AND RECONDITIONED AS REQUIRED (CLEAN AND COMB EVAPORATOR COIL, REPACK OR REPLACE BEARINGS, REPLACE FAN BELTS, LUBRICATE, PURGE CONDENSATE DRAINAGE PIPING, REPLACE FILTERS, CLEAN CASING, REMOVE RUSTED AREAS AND PAINT WITH RUST INHIBITOR, REPLACE ANY SECTION OF UNIT DAMAGED INSULATION, ETC.). ALL EXISTING THERMOSTATS AND CONTROL DEVICES SHALL ALSO BE THOROUGHLY CHECKED AND RECONDITIONED (OR REPLACED) AS REQUIRED, TO ASSURE THE PROPER OPERATION OF THE AIR CONDITIONING SYSTEMS. ADJUST AHU'S TO DELIVER THE INDICATED AMOUNT OF SUPPLY AND OUTSIDE AIR CFM. IF A CHANGE IN DRIVE SIZE IS REQUIRED IN ORDER FOR THE AHU'S TO ACHIEVE THE SPECIFIED CFM VALUES, CONTRACTOR SHALL PROCEED TO PROVIDE THE REQUIRED DRIVE SIZE. 20 EXISTING FAN COIL UNITS'S # D1A7C1 (EAST) AND D1A7C1(WEST) INSTALLED ABOVE THE CAFETERIA'S CEILING, SHALL BE REFURBISHED. BOTH UNITS SHALL BE THOROUGHLY CHECKED AND RECONDITIONED AS REQUIRED (CLEAN AND COMB EVAPORATOR COIL, REPACK OR REPLACE BEARINGS, REPLACE FAN BELTS, LUBRICATE, PURGE CONDENSATE DRAINAGE PIPING, REPLACE FILTERS, CLEAN CASING, REMOVE RUSTED AREAS AND PAINT WITH RUST INHIBITOR, REPLACE ANY SECTION OF UNIT DAMAGED INSULATION, ETC.). ALL EXISTING THERMOSTATS AND CONTROL DEVICES SHALL ALSO BE THOROUGHLY CHECKED AND RECONDITIONED (OR REPLACED) AS REQUIRED, TO ASSURE THE PROPER OPERATION OF THE AIR CONDITIONING SYSTEMS. ADJUST AHU'S TO DELIVER THE INDICATED AMOUNT OF SUPPLY AND OUTSIDE AIR CFM. IF A CHANGE IN DRIVE SIZE IS REQUIRED IN ORDER FOR THE AHU'S TO ACHIEVE THE SPECIFIED CFM VALUES, CONTRACTOR SHALL PROCEED TO PROVIDE THE REQUIRED DRIVE SIZE. 0 4' 8' SCALE: 3/16 " =1' -0" I SOUTH MIAMI HOSPITAL SUNSET CAFE CAFETERIA RENOVATION 6200 S.W. 73rd STREET MIAMI, FL 33143 Owner General Contractor LEA DA V IIN�TE1t1 1I ." E EST. 1915 3:390 Mary Street, Suite 216 Miami Florida :33133 USA T: 305.461.9480 F: 305.461.3686 Architect Associate Architect PROJ. No. 22016 CA 924 LOUIS J. AGUIRRE & ASSOCIATES P.A. CONSULTING ENGINEERS 9150 SOUTH DADELAND BLVD, SUITE 900 MIAMI, FLORIDA 33156 TELEPHONE: (305) 670 -0141 FAX: (305) 670 -0144 www.ljaapa.com N CAFETERIA Not to Scale 061 -10064 -020 Architects Project Nurnber FOR PERMIT Drawing Issue 11/13/2012 REVISIONS NO. DESCRIPTION DATE LEO A DALY COMPANY Copyright 2012 assn ��TMa erg i4 P �T a+ '��<rdr C-1 en MECN .NICAL, ERGIO RRANO P.E. LICE SE # 57864 Seal FLOOR PLAN HVAC Shea Titic M3,02 Shcct Number