Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-62-010
CONSTRUCTION NOTES ACCESSIBILITY: EXISTING SHELL BUILDING AND ENTRANCES PROVIDED EXISTING PARTITIONS: ALL INTERIOR PARTITIONS EXISTING TO REMAIN SHALL COMPLY WITH ALL REQUIRED ACCESSIBILITY ISSUES AS PER UNLESS OTHERWISE NOTED. PATCH AND REPAIR ALL WALLS AS SECTION 4.13 NECESSARY TO RECEIVE NEW SCHEDULED FINISH. ACCESSIBILITY CODE: ALL WORK SHALL BE PERFORMED TO MEET AND COMPLY WITH FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. RATED PENETRATION: SEAL ALL PENETRATIONS THROUGH 1 HR RATED PARTITIONS AND SMOKE PARTITIONS WITH HILT] FIRESTOP SEALANT FS -ONE OR EQUAL THAT MEETS ATSM -E 814 (UL 1479). INSTALL AS PER MANUFACTURER RECOMMENDATION FOR 1 HR RATINGS. SPRINKLERS: ENTIRE BUILDING IS FULLY SPRINKLERED. MODIFICATIONS WILL BE DONE TO EXISTING SYSTEM WITHIN AREA OF WORK. SMOKE BARRIER SIGN: PROVIDE "FIRE AND SMOKE BARRIER, PROTECT ALL OPENINGS" SIGN ABOVE ANY DECORATIVE CEILING AND CONCEALED SPACES ON CORRIDOR PARTITIONS, SMOKSTOP PARTITIONS, HORIZONTAL EXIT PARTITIONS, EXIT ENCLOSURES AND FIRE RATED WALLS CORE DRILLING:. CONTRACTOR TO X -RAY SLAB PRIOR TO ANY PENETRATIONS. MANAGEMENT MUST APPROVE X -RAY PRIOR TO CORE DRILLING. COORDINATE OF WORK: GENERAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES. 1 CONSTRUCTION FLOOR PLAN 4" 0 4" 8" A1.01 SCALE: 1/8 " =1' -0" SCALE: 1/8"=1 1-01, /04T nS�,� l4Ci PORTMN OF 113HA -1 gfpi °qv THE' PAOVI b1 ()IN s ()i :'.r <1t��1�1�t KJ��it}t'�� �%��; ; \ C FORTH IN THE Fu) ml u PARTITION TYPES U EXISTING 1 —HOUR SMOKE BARRIER PARTITION: PREPARE EXISTING GYP. BD. AS REQUIRED TO RECEIVE NEW FINISH. REFER TO FINISH SCHEDULE. GENERAL CONTRACTOR TO VERIFY H MA DALY EN ERIOR, E 0 EST. 1915 3390 Mary Street, Suite 216 Miami Florida 33133 USA T: 305.461.9480 F: 305.461 .3686 Architect CONDITION AND PROVIDE AS REQUIRED Associate Architect O EXISTING PARTITION ON CMU /CONCRETE• G.C. TO VERIFY CONDITION AND PROVIDE AS REQUIRED. PREPARE SURFACES AS REQUIRED TO RECEIVE NEW FINISH. REFER TO FINISH SCHEDEULE. O NEW PARTITION — FULL HEIGHT: 061 - 10064 -020 V GYPSUM BOARD TYPE "X" BOTH SIDES OF 3 % " METAL STUDS 25 GA. AT 24" O.C. TO UNDERSIDE OF QONC. DECK ABOVE. PREPARE SURFACES AS REQUIRED TO RECEIVE_ NEW FINISH. REFER DATE TO FINISH SCHEDULE. SEE DETAIL 6/A9.01. ® EXISTING PARTITION - FULL HEIGHT: UPGRADE EXISITNG PARTITION TO MEET REQUIREMENTS OF A SMOKE TIGHT PARTITION. EXTEND GWB TO DECK AS NEEDED, SEAL ALL PENETRATIONS, AND SEAL WALL TIGHT TO FLOOR AND DECK. PREPARE SURFACES AS REQUIRED TO RECEIVE NEW FINISH. REFER TO FINISH SCHEDULE. O NEW PARTITION: 5/8" GYPSUM BOARD TYPE "X" BOTH SIDES OF 3 8" METAL STUDS 25 GA. AT 24" O.C. TO 6" ABOVE FINISH CEILING. BRACE TO UNDERSIDE OF STRUCTURE ABOVE. PREPARE SURFACES AS REQUIRED TO RECEIVE NEW FINISH. REFER TO FINISH SCHEDULE. SEE DETAIL 5/A9.01 © NEW LOW PARTITION: %" GYPSUM BOARD TYPE "X" BOTH SIDES OF 3 R" METAL STUDS 25 GA. AT 24" O.C. 48" A.F.F. PREPARE SURFACES AS REQUIRED TO RECEIVE NEW FINISH. REFER TO FINISH SCHEDULE. 7O FURRING AT EXISTING COLUMN: V GYPSUM BOARD ON METAL FURRING CHANNELS ON EXISTING CONCRETE COLUMN TO 6" ABOVE FINISH CEILING. PREPARE SURFACES AS REQUIRED TO RECEIVE NEW FINISH. REFER TO FINISH SCHEDULE. GENERAL CONTRACTOR TO VERIFIY CONDITION AND PROVIDE AS REQUIRED. ® EXISTING COLUMN: PATCH AND REPAIR EXISTING GYPSUM BOARD TO MATCH ADJACENT SURFACES ) NEW 1 HR SMOKE PARTITION: %" GYPSUM BOARD TYPE "X" BOTH SIDES ON 3 -5/8" METAL STUDS 25 GA. AT 24" O.C. ALL TO UNDERSIDE OF CONC. DECK ABOVE. PROVIDE SOUND ATTENUATION BATT INSULATION (R-11) PREPARE EXISTING GYP. BD. AS REQUIRED TO RECEIVE NEW FINISH. THE SPACE AROUND PENETRATING ITEMS AND IN JOINTS SHALL BE FILLED WITH AN APPROVED MATERIAL TO LIMIT THE FREE PASSAGE OF SMOKE. 1 HR. FIRE SMOKE RATING REQUIRED AS PER U465. SEE DETAIL 6A/A9.01 10 INFILL SMOKE PARTITION: 25 GA. METAL STUD FRAMING AT 12" O.C., STUD SIZE TO MATCH EXISTING WALL WIDTH, WITH V TYPE "X" GYP. BD. EACH SIDE. CONTINUOUS SEALANT ALONG INFILL WALL PERIMETER. I� LEGEND NEW PARTITION DENOTES MILLWORK DENOTES SERVERY EQUIPMENT, N.IC.,REFER TO KITCHEN PACKAGE FOR EQUIPMENT DESCRIPTION AND LAYOUT EXISTING, NOT IN THE SCOPE OF WORK SOUTH MIAMI HOSPITAL SUNSET CAFE CAFETERIA RENOVATION 6200 S.W. 73rd STREET MIAMI, FL 33143 Owner General Contractor H MA DALY EN ERIOR, E 0 EST. 1915 3390 Mary Street, Suite 216 Miami Florida 33133 USA T: 305.461.9480 F: 305.461 .3686 Architect Associate Architect IN CAFETERIA Not to Scale 061 - 10064 -020 — Architects Project Number FOR PERMIT 11/13/2012 Drawing Issue REVISIONS NO. DESCRIPTION DATE Seal LEO A DALY COMPANY Copyright 2012 I u SERGIO PENDAS, AIA REGISTERED ARCHITECT AR 0013943 Sheet CONSTRUCTION FLOOR PLAN, LEGEND AND NOTES Title Sheet A1,01 Number