Loading...
13-62-004EXCEPT WHERE MODIFIED BY PROPOSED WORK, EXISTING LIFE SAFETY INFORMATION CONTAINED HEREIN INCLUDING BUT NOT LIMITED TO: WALL RATINGS, EXIT SIGN LOCATIONS, EXIT CALCULATIONS, EXIT CAPACITY, AND BUILDING TYPE WAS OBTAINED FROM EXISTING DRAWINGS PROVIDED BY THE OWNER. CONTRACTOR SHALL NOTIFY A/E IF EXISTING CONDITIONS ENCOUNTERED DO NOT CONCUR WITH INFORMATION DEPICTED ON DRAWINGS. CODE INFORMATION GENERAL DESCRIPTION A. APPLICABLE CODES: 1. FLORIDA BUILDING CODE - 2010 2. FLORIDA EXISTING BUILDING CODE - 2010 EDITION ALTERATIONS: LEVEL 2 3. FLORIDA FIRE PREVENTION CODE - 2010 EDITION. 4. 2010 NATIONAL ELECTRICAL CODE 5. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION BUILDING CLASSIFICATION: B. 1. OCCUPANCY TYPE: GROUP 1 -2, INSTITUTION II. TYPES OF CONSTRUCTION - FIRE RESISTANCE REQUIREMENTS A. REQUIRED WIDTH OF OPENINGS FBC SECTION 1005.1 -REFER TO LIFE SAFETY ANALYSIS, REQUIRED EGRESS CAPACITY B. EXIT ACCESS TRAVEL DISTANCE - 250' (FBC TABLE 1016.1) IN FULLY SPRINKLERED FACILITIES C. EGRESS WIDTH - INCHES /PERSON (FBC 1005.1, NFPA TABLE 7.3.3.1) STAIRS - 0.3 OTHER - 0.20 D. MINIMUM CORRIDOR WIDTH REQUIRED = 44" (FBC SECTION 1018.2) E. MINIMUM DISTANCE BETWEEN REQUIRED EXITS = 1/3 DIAGONAL (FBC SECTION 1015.2.1) F MINIMUM NUMBER OF EXITS FOR ASSEMBLY OCCUPANT LOAD = 1 WITH MAX. OCCUPANT LOAD OF 49 (FBC 1015.1) G. MAXIMUM COMMON PATH = 75' (NFPA TABLE A7.6 - 1014.3) H, DEAD END CONDITION = 20 FT IN FULLY SPRINKLERED FACILITIES (1018.4) LEVEL OF PROTECTION OF MEANS OF EGRESS SHALL NOT BE REDUCED UNTIL ARRIVAL AT EXIT DISCHARGE - 1018.6 J. WOOD USED FOR FRAMING AND MILLWORK SHALL BE FIRE - RETARDANT TREATED FIRE PROTECTION SYSTEMS FULLY AUTOMATIC SPRINKLER SYSTEM PROVIDED THROUGHOUT EXISTING BUILDING 1. FIRE EXTINGUISHERS: PROVIDED AT 75' -0" MAX. PATH OF TRAVEL FROM ANY POINT IN THE SPACE. 2. FIRE ALARM SYSTEM PROVIDED NOTE: 1. SPACE IS FULLY SPRINKLERED WITH AN EXISTING SYSTEM 1 LIFE ! SAFETY PLAN 4 0 4 8 A0.02 SCALE: 1/8 " =1' -0" SCALE: 1/8"=V-0" LIFE SAFETY ANALYSIS FLORIDA BUILDING CODE EGRESS REQUIREMENTS OCCUPANCY MAXIMUM DISTANCE COMMON PATH OF REQUIRED EGRESS MIN CLEAR OP'G REQUIRED MIN, PROVIDED CLASSIFICATION TO TRAVEL EXIT (FT.) EGRESS TRAVEL CAPACITY OF EXIT DOORS NUMBER OF EXITS EXITS FOOD PREP= 6 REQUIRED 1014.3 SECTION 1005 TABLE SECTION TABLE 1021.1 TABLE 1016.1 N CAFETERIA Not to Scale 1008.1.1 OR AS MODIFIED Architects Project Number FOR PERMIT 11/13/2012 Drawing Issue REVISIONS BY 1015.1- 1021.2 DESCRIPTION ASSEMBLY 250 75' UNSPRINKLERED 414 x 0.2= 83" 32" - MINIMUM 2 (1 -500 OCC) 2 A -2 SPRINKLERED 100' SPRINKLERED REQUIRED WIDTH 42" CLEAR DOOR WIDTH 68" CLEAR DOOR WIDTH 110" TOTAL PROVIDED OCCUPANT LOAD AREA (S.F.) OCCUPANT FACTOR OCCUPANT LOAD TOTAL OCCUPANT LOAD DINING =2747 SF DINING = 15 PER DINING= 183 SERVERY= 1562 SF SERVERY= 7 PER SERVERY= 223 414 FOOD PREP= 573 SF FOOD PREP= 100 PER FOOD PREP= 6 GRIDDLE ROOM= 194 SF GRIDDLE ROOM= 100 PER GRIDDLE ROOM= 2 LIFE SAFETY LEGEND EXISTING PARTITION TO REMAIN KITCHEN AREA NEW PARTITION. SEE WALL TYPE / / SERVERY AREA EXISTING NOT IN THE SCOPE OF WORK 1 HR. SMOKE BARRIER DINING AREA SMOKE PARTITION ® EXIT LIGHT. SEE ELECTRICAL DWGS. TRAVEL DISTANCE EMERGENCY LIGHT. SEE ELECTRICAL DWGS. MILLWORK F FIRE ALARM HORN /STROBE COMBINATION. SEE .. ............................... � ELECTRICAL DWGS. — — — — — EQUIPMENT LINE FIRE ALARM PULL STATION OCCUPANT LOAD /CAPACITY OF EXIT F E EXISTING WALL MOUNTED FIRE EXTINGUISHER NOTE: 0S G.C. TO FURNISH AND INSTALL NEW RECESSED STAINLESS STEEL CABINETS FOR EXISTING EXTINGUISHERS WALL MOUNTED STROBE LIGHT SOUTH MIAMI HOSPITAL-. SUNSET CAFE CAFETERIA RENOVATION 6200 S.W. 73rd STREET MIAMI, FL 33143 Owner General Contractor IDADALY INGEKN0Ek�rNGE EST. 1915 3390 Mary Street, Suite 216 Miami Florida 33133 USA T: 305.461 .9480 F: 305.461 .3686 Architect Associate Architect ww N CAFETERIA Not to Scale __ 061 - 10064 -020 Architects Project Number FOR PERMIT 11/13/2012 Drawing Issue REVISIONS NO. DESCRIPTION DATE LEO A DALY COMPANY Copyright 2012 � 1w / � A p- C � y Rf, ':•C � C •-T-'I SERGIO PENDAS, AIA REGISTERED ARCHITECT AR 0013943 Seal LIFE SAFETY Sheet Title A00`02 Sheet Number