Loading...
13-480-011i Settings 8 PS Circuit Starting Device Amber Qty lPreflx Icircult# Qty On? 2 1 N:151 I 1 I Both Iann & AI cute 1 4 PS Capacity Circuit Capacity Total Supv. Total Alarm Quantity 4009 S.A 2.A A 6.874A Total Module Qty .A A Standby Current Alarm .A A 19.5 1 4.3% 9 .A A NAC 15 4009-92014009 NAC 1 0.0850 1 0.1850 0.0850 0.1850 0.0000 6.8740 Total 0.0850 1 7.0590 Quantity 4009 Configuration Capacity: 8.000A Ckt Capacity: 2.000A Aux. Capacity: 0.500A Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment 10 19.5 1 4.3% 9 19.5 1 24.1% 4009 -9201 1 1 14009 1DNET NAC EXTENDER, 120 VAC 1 0.0850 1 0.0850 1 0.1850 1 0.1850 110cd QWE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED SOLID COPPER WIRE) @ Panel Totals 85 mA 0.0850 1 0.1850 Notification Appliances VIO A/V A/V 226 mA 1 164 mA 4906 -9101 1 1 VIO MC NON - ADDRESS, RED, WALL 15 0.0000 0.0000 0.0600 0.0600 4906 -9101 20 1 VIO MC NON - ADDRESS, RED, WALL 75 0.0000 0.0000 0.1860 3.7200 4906 -9127 14 1 AA/ MC NON - ADDRESS. RED, WALL 75 0.0000 0.0000 02210 3.0940 z f Peripheral Totals 0.0000 Alarm Current 6.8740 0.1860 0.2520 RUI Totals 0 0.2850 0.0000 Power 0.0000 Plan Dist (D) Wire Wire Rr s. 0.0850 V. Drop 7.0590 % Volt Min Device Max Select ALL Power Supplies on this battery set: M_ J O J 0 a NOTIFICATION CIRCUIT DESCRIPTION Supply Circuit Total 0.0850 Gauge 7.0590 Alarm A A•2D•R Standby Time - 4 Hrs x 0.0850 = 0.3400 Standby Ah V Alarm Time - 15 Min 0.25 x 7.059 = 1.7648 Alarm Ah N:1511 295 14ga 0.00307 1.779 2.1048 16.278 16.52% 16vdc 320 Ft Additional Spare Capacity- 10% + 0.2105 3 0 3RD FLOOR STROBES 4009 SIG2 N:1612 2.3152 14ga 0.00307 1.895 3.316 Battery Discharge Factor- 20% + 0.4630 301 FL 0 9 0 Minimum Battery Required 2081 -9272 6.2AH (2x) 2.7783 3RD FLOOR STROBES 4009 SIG3 N:1513 Battery Supplied 2081 -9272 6.2AH 2x 14ga 0.00307 1.758 5 NAC 15 4009-92014009 NAC VOLTAGE DROPS 1 0.0850 1 0.1850 0.0850 0.1850 0.0000 6.8740 Total 0.0850 1 7.0590 Quantity 4009 Configuration Capacity: 8.000A Ckt Capacity: 2.000A Aux. Capacity: 0.500A Per Output Cannel PID 4906 -9101 4906 -9101 4906 -9101 4906 -9127 4906 -9127 9 19.5 5.3% 10 19.5 1 4.3% 9 19.5 1 24.1% 7 164 mA Candela IScd 75cd 110cd 75cd 110cd QWE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED SOLID COPPER WIRE) @ 75 Celsius 85 mA 63 mA Device Type VIO VIO VIO A/V A/V 226 mA 1 164 mA LIj 1` O O OQLhtLn 0 0 z V o o rn ( (n O Supv. Current (F 9" 1,n.•rq ,• ;, ,,,p n v, r-) o (141; O V V Q Q z f fA Alarm Current 0.0600 0.1860 0.2520 0.2210 0.2850 Power Panel Plan Dist (D) Wire Wire Rr s. Total V. Drop Volt % Volt Min Device Max M_ J O J 0 a NOTIFICATION CIRCUIT DESCRIPTION Supply Circuit Ckt Feet Gauge / Ft. R Alarm A A•2D•R @ End Drop Voltage Distance Z O V 3RD FLOOR STROBES 4009 SIG1 N:1511 295 14ga 0.00307 1.779 3.222 16.278 16.52% 16vdc 320 Ft 0 6 0 3 0 3RD FLOOR STROBES 4009 SIG2 N:1612 285 14ga 0.00307 1.895 3.316 16.184 17.01% 16vdc 301 FL 0 9 0 1 0 3RD FLOOR STROBES 4009 SIG3 N:1513 310 14ga 0.00307 1.758 3.346 16.154 17.16% 16vdc 324 FL 1 2 0 6 0 3RD FLOOR STROBES 4009 SIG4 N:15/4 300 14ga 0.00307 1.442 2.656 16.944 13.62% 16vdc 395 Ft 0 1 3 1 0 4 0 NOTE: LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD IS RECOMMENDED FOR THE MARGIN OF SAFETY IT PROVIDES FOR THE UNKNOWN. IT TAKES INTO CONSIDERATION THAT THE ROUTING SHOWN ON THE SHOP DRAWINGS MAY DIFFER FROM WHAT IS THE ACTUAL INSTALLED CIRCUIT. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT LENGTH, CONTACT YOUR LOCAL SIMPLEXGRINNELL DISTRICT OFFICE. IER SUPPLY SUMMARY Module Qty Description 1RESSABLE DEVICES REQUIRING 24VDC AUX. POWER :ELLANEOUS 24VDC PERIPHERALS FZiviZa94 ill 014 7_119 Powered By 4009 SUMMARY Ext Source Standby Alarm Total Total Qty. Current Current Qty Standby Alarm 0 I 0.0000 1 0.0150 I 0 0.0000 0 0.0000 0.0240 0 0.0000 1 0.0850 1 0.1850 Components NAC Currents from Voltage Drops 1 0.0850 1 0.1850 0.0850 0.1850 0.0000 6.8740 Total 0.0850 1 7.0590 Quantity 4009 Configuration Capacity: 8.000A Ckt Capacity: 2.000A Aux. Capacity: 0.500A MAB BATTERY CALCULATIONS \\ 1 \IMNFONG\00 -2D0rX 00 -2003 CAD DrtAWOIGS \SOUTH WR Ho7M (IMM S(IE) \SMH ►NB STE 305 \StM INB RM 3MDNG DATE CRLATED: April 19. 2013 DATE PIZ=: April 22. 2013 DA1Z SAVZD: April 19, 2013 Minimum HOUSING COLOR Device Voltage @ RMS CURRENT Quantity NAC Circuit I Per Output Cannel Circuit/ Terminals Capacity Branch 19.5 7.8% 9 19.5 5.3% 10 19.5 1 4.3% 9 19.5 1 24.1% 7 TrueAlertTMNON-ADDRESSABLE MULTI - CANDELA VISIBLE NOTIFICATION APPLIANCE PRODUCT INFORMATION (WALL MOUNT) WHEN SURFACE MOUNTING USE FEATURES. • UL LISTED TO STANDARD 1971 • ADA COMPATIBLE SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: *SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE FOR CLASS B OR CLASS A OPERATION •SEPARATE SMARTSYNC CONTROL MODULES (SCMs) THAT PROVIDE CLASS B OR CLASS A OUTPUT FROM CONVENTIONAL NAC INPUTS SPECIFICATIONS: • HOUSING DIWENSIONS: 5 -1/8" H X 5- W X 2 -3/4- D (130mm X 127mm X 70mm) • TEMPERATURE RANGE: 327 TO 1227 (0 TO 50'C) • HUMIDITY RANGE: 10% TO 93% NON- CONDENSING AT 1007 (38'C) • TERMIMAL BLOCKS FOR 1BAWG TO 12AWG; TWO WIRES PER TERMINAL FOR IN /OUT WIRING. WIRING: 1. NOTiFICA.:^!l APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL. 2. MAINTAIN CORECT POLARITY ON TERMINAL CONNECTIONS. DO NOT LOOP WIRES UNDER TERMINALS. 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER- LIMITED. 4. SEE INSTALLATION INSTRUCTIONS (579 -548) FOR ADDITIONAL INFORMATION. STROBE: *RATED VOLT,`,GE RANGE: UL LISTED: 16 VDC TO 33 VDC PER UL 1971 ULC LISTED: 20 VDC TO 30 VDC PER ULC 5526 - MB78 • FLASH RATE: 1Hz • SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. 2975 -9145 BOX 105 -9961 OPTIONAL WIRE IARD (SHOWN HERE FOR TERENCE ONLY, CAN BE ;ED ON OTHER MOUNTING 'TIONS) RED SKIRT NO. 4905 -9937 OR WHITE SKIRT NO. 4905 -9940 *CURRENT DRAWS REFLECT STROBE FLASHING :; ,_MI -FLUSH MOUNTING 4' SQUARE x 1 -1/2- DEEP BOX TERNATE BACK BOXES 2 GANG 1 -1/2- DEEP BOX SINGLE GANG 1 -1/2- DEEP BOX TO ADDITIONAL NOTIFICATION APPLIANCE DEVICE OR RETURN -� TO FACP FOR STYLE Z APPLICATION _ IF LAST DEVICE ON CIRCUIT IN A IO STYLE APPLICATION LINE 3 d 4 ARE NOT USED /2W END OF NE RESISTOR I � TERNW I OCD I IL 2 FROM A COMPATIBLE SIMPLEX -- I- -� ®O O UL SMARTSYNC NAC OR FROM - SMARTSYNC CONTROL MODULE (SCM) 4905 -9938 OR SIMPLEX 4905 -9914 OR 9922 SYNC CUBE MODEL NUMBER HOUSING COLOR LETTERING COLOR STROBE RATING RMS CURRENT 16 VDC 18 VDC 24 VDC 4906 -9101 RED WHITE 15cd 60 mA 55 mA 41 mA 30cd 94 mA 85 mA 63 mA 75cd 186 mA 169 mA 123 mA 110cd 252 mA 226 mA 164 mA 4906 -9103 WHITE RED I 15cd 60 mA 1 55 mA 1 41 mA �C:) 30cd 94 mA 85 mA 63 mA 75cd 186 mA 169 mA 123 mA 110cd 252 mA 226 mA 1 164 mA WIRING TYPICAL INTENSITY SELECTION PW% ACCESSIBLE ONLY FROM REAR OF HOUSING: FACTORY SET71NO IS 15cd STROBE INTENSITY VIEWING SLOT MIAMI -DADE CO. ME DEPAR W IZ 'T . t:. F W W U) Q_ z z� Q W W M MI LL �0 = Q Q �C:) a F F-U) cu W WMC? T T . M ~ ~ LIj 1` O O OQLhtLn 0 0 z V o o rn ( (n O t� z Lij IL CL LL d d O V V Q Q z f fA M J a � Z W W Z> Z W W O t � L� 2 tXi � to K M_ J O J 0 a Z O L: Z Z Z O V W O W W Z r rn U W O Of O LL 0 M D E0 U) Of m U U t� rn Ov I z m mi_ , , 1- - I c r I I-- `/ t 0 z g ° r g W Z W Of U_ to W W W co') � W L LL N O -+ W O O Z J W O ° °z to Q J �0, 0 C) r 0 U U W Of W O U U 0 03 d tit L U_ v� z ,L U W y a a5 O o EL E-1 O O it Q O I=- U O O S s sO W O OO Z L7 w_j C CL LO Zj O Z J J O Q w U O rn 1- ? W U U J W O LL W W Q Q Q U) cc ►�-1 Q 0 =) 0 V1 M 2 Vr W 0') W W U) � Q Q Q a O Z CQ LL U � w w w Z Z >O z 0 O � O W � Z Ja 04 r- 0 0Q¢ �o DRAWN BY: D DATE: CCRJR 4 4/18/13 DESIGNED BY: D DATE: CCRJR 4 4118/13 APPROVED BY: D DATE: PROJECT NUMBER: 263-410304 SHEET TITLE/ PATH: SHEET NUMBER: BATTERY -2 IIII. SIZE D (24-X36')