13-445-012ABBREVIATIONS =13- ............................... _q ABC ABOVE COUNTER ACLG ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE BKR BREAKER CB CIRCUIT BREAKER cd CANDELA CKT CIRCUIT CL CENTER LINE CLG CEILING MOUNTED DEVICE DISC DISCONNECT DIV DIVISION EX EXISTING F FRAME F/A FIRE ALARM FBO FURNISHED BY OTHERS FLA FULL LOAD AMPS FU FUSE G GROUND HP HORSE POWER 100 10 CE CT OR ABBREVIATIONS K KILO MCB MAIN CIRCUIT BREAKER MLO MAIN LUGS ONLY NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT OC OVER CURRENT OCP OVER CURRENT PROTECTION P POLE PH PHASE SMH SPECIAL MOUNTING HEIGHT TV TELEVISION TYP TYPICAL UH UNIT HEATER UG UNDER GROUND ELECTRICAL LION UNLESS OTHERWISE NOTED V VOLT(S) VA VOLT-AMP(S) W WATT(S), WIRE, WALL TELEPHONE OUTLET WP WEATHERPROOF DEVICE, NEMA 313 XFMR TRANSFORMER 10 100 1K 10K LEGEND DESCRIPTION MOUNTING HEIGHT FAULT STUDY NON-FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING/POLES) FEEDER INPUT DATA FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING/POLES) COMBINATION MOTOR STARTER FEEDER FROM FEEDER TO QTY VOLTS LENGTH FEEDER FACTORY WIRED CONTROLLER OR EQUIPMENT NAME MOTOR CONNECTION NAME /PH L-L JUNCTION BOX TYPE`- PANEL OAR D - FLUSH MOUNTED CT*4 VFD PANELBOARD - SURFACE MOUNTED FEET 3/0 COPPER VARIABLE FREQUENCY DRIVE DUCT CONCEALED CONDUIT MAGNETI C I NSULATI ON TYPE: PVC INSULATION CONDUIT CONCEALED IN FLOOR OR BELOW GRADE THWN +/- HOMERUN TO PANELBOA•D - NUMBER OF PHASE CONDUCTORS IN MINIMUM 314 0.0805 + J 0.0519 OHMS/1000 FT CONDUIT UNLESS NOTED OTHERWISE 1. 35 PU NOTES: LONE NEUTRAL CONDUCTOR FOR EACH PHASE CONDUCTOR,ALTHOUGH NOT I MPEDANCE: INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. 6.61 + J 2. ONE INSULATED GREEN GROUNDING CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. MCCN 3. HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE (3) PHASE CT*4 VFD 1 480 10.0 CONDUCTORS (ONE PER PHASE) PLUS THREE (3) NEUTRAL CONDUCTORS AND COPPER ONE (1) GROUND CONDUCTOR IN EACH CONDUIT. 4. MULTI-WIRE BRANCH CIRCUITS THAT SHARE A COMMON NEUTRAL SHALL NOT BE MATERIAL: PERMITTED FOR INDIVIDUAL LINE-TO-NEUTRAL LOADS. PVC INSULATION CLASS: 5. EACH CIRCUIT (PHASE AND NEUTRAL CONDUCTORS) SHALL BE GROUPED TOGETHER USING CABLE TIES AT THE PANELBOARD AND ALL JUNCTION BOXES, PULL BOXES I MPEDANCE: AND ALL OTHER LOCATIONS WHERE TERMINATIONS, CONNECTIONS OR SPLICES 0.3494 + J ARE MADE. 6. ALL CONDUCTORS SHALL BE *12 AWG UNLESS OTHERWISE NOTED. ALL WORK -SHALL COMPLY WITH THE 2008 EDITION OF THE NEC. FAULT STUDY Roma Poww & UDM C=PNW, P.O. 0010"100, Miami. FL MOM 00 FPL June 29, 2010 Mr. Dennis Q. Davis Smith Seclanan Reid, Inc. 600 West Hillsboro Blvd. Deerfield Beach, Florida 33441 Re: Symmetrical Fault Current for FPL Project Name: 1232017 Facilities TCC Name: CT*4.tcc Dear Mr. Davis: Reference Voltage: 480 V Current Scale: X 1000 You recently requested symmetrical fault current information at the FPL facilities at two ----------------------------------------------------------------------------------------- locations on the main campus of South Miami Hospital. As such, the information is as follows: CAPTOR (Computer Aided Plotting for Time Overcurrent Reporting) 2-1500 kVA transformers in parallel, with a secondary voltage of 2771480 V in the main vault. COPYRIGHT SKM SYSTEMS ANALYSIS, INC. 1983-2006 The symmetrical fault current at this facility Is 54,000 Amps. This is calculated with an actual ----------------------------------------------------------------------------------------- impedance of 4.8% on each of the transformers. This assumes an infinite bus at the vault. Device Name: MCB MSNI TCC Name: CT*4.tcc MSN1 Bus Name: SWBD MSNI Bus Voltage: 480.OV The 1500 WA transformer in the same vault has a symmetrical fault current of 31,000 Amps. Function Name: Phase This also assumes an infinite bus at the transformer with an actual impedance of 4.90A. Manufacturer: SQUARED Description: LI, 1800-2000A Sub Type: PE, MicrologIc The 1000 WA transformer in the North Tower vault has a symmetrical fault current of 22,000 AIC Rating: lOOkA Overrlde:18 Amps. The same assumptions apply with an actual impedance rating of 4.89% Frame: PE 480V 2000A Curve Multiplier: 1 The FPL equipment currently serving or planned to serve your facility may change over time as Sensor: 2000A a result of any number of factors, including but not limited to transformer replacements due to Plug: 2000A load growth, electrical grid changes or emergencies. As a result, although we are providing you Setting: 1) LTPU (0.5-1.0 x P) 1.0 (2000A) with this information for the sole purpose of assisting you in the -completion of your study, you MCCN 2) LTD (2-24 Sec.) 7.0 should not design, install or operate your system in reliance upon any expectation that the specific size and type of equipment currently in place will remain so. If and when the size and -------- 3) INST (2-6 x P) 6.0 (12000A) type of the equipment changes, our employees are not always in a position to immediately notify --------------------------------------------------------------------------------- customers. Device Name: CB MCCN TCC Name: CT*4.tco This calculated symmetrical fault current is not intended for use as the basis for motor starting m Bus Name: SWBD MSNI Bus Voltage: 480.OV calculations and does not include consideration for any motor contribution or fault current Function Name: Phase asymmetry. Manufacturer: SQUARE D Description: LI, 100-800A C/) Sub Type: ME, Mlcrologic ANYONE USING OR RELYING ON THIS INFORMATION DOES SO AT THEIR OWN RISK, M AIC Rating: 65kA AND FLORIDA POWER & LIGHT COMPANY DISCLAIMS ANY LIABILITY FOR EITHER Frame: ME 480V 800A Curve Multiplier: I NEGLIGENCE OR WARRANTY ARISING THERE FROM. 0 Sensor: BOOA I z Plug: 600A If you have any questions or concerns please call me at (305) 552-2507. 0 Cl) Setting: 1) LTPU (0.5-1.0 x P) 1.0 (600A) SiWncely 2) LTD (2-24 Sec.) 16 3) INST (2-12 x P) 8.0 (4800A) ----------------------------------------------------------------------------------------- ector.). Maestri, C.E.M. Device Name: CB CT*4 TCC Name: CT#4.tcc Major Account Manager Bus Name: MCCN BUS Bus Voltage: 48O.OV Function Name: Phase an Fft Gm* cmwny Manufacturer: SQUARE D Description: 150-250A Sub Type: Powerpaot JJ AIC Rating: 65kA Frame: JJ 480V 250A Curve Multiplier: I Trip: 200A Setting: 1) Thermal Curve 2) Im LO (1OOOA) ----------------------------------------------------------------------------------------- ELECTRICAL DRAWING INDEX Device Name: CT-4 TCC Name: CT*4.tcc Bus Name: CT#4 DISCONNECT Bus Voltage: 480V Description: Motor Starting Curve Inrush: 6.0 (462.0A) NO. SHEET TITLE Rated Size: 60HP 0 of I Plotted) FLA+Load Adder: 77.OA + O.OA 1 OOK Power Factor: 1.000 Starting Time: 10.00s Efficiency: 0.80 Full Voltage (Curve) EO.Ol ELECTRICAL LEGEND. STUDIES & DRAWING INnFY CT#4.tcc Ref. Voltage: 480 Current in Amps x 1 CT#4.drw (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com irin Certification - EB-0000857 John E. Moulder PE - 33200 Mchael A. Steward PE - 65701 SSR JOB # 1232017.0 FEEDER INPUT DATA CABLE FEEDER FROM FEEDER TO QTY VOLTS LENGTH FEEDER NAME NAME NAME /PH L-L SIZE TYPE`- FDR CT-4 CT*4 VFD CT *4 DISCONNEC 1 480 60.0 FEET 3/0 COPPER DUCT MATERIAL: MAGNETI C I NSULATI ON TYPE: PVC INSULATION CLASS: THWN +/- I MPEDANCE: 0.0805 + J 0.0519 OHMS/1000 FT 2.10 + J 1. 35 PU ZO I MPEDANCE: 0.2537 + J 0.1278 OHMS/1000 FT 6.61 + J 3.33 PU FOR CT-4 VFD MCCN BUS CT*4 VFD 1 480 10.0 FEET 3/0 COPPER DUCT MATERIAL: MAGNETI C I NSULATI ON TYPE: PVC INSULATION CLASS: THWN +/- I MPEDANCE: 0.0805 + J 0. 0519 OHMS/1000 FT 0.3494 + J 0.2253 PU ZO I MPEDANCE: 0. 2537 + J 0. 1278 OHMS/I 000 FT 1.10 + J 0.5547 PU FOR MCCN SWBD MSN1 MCCN BUS 2 480 145.0 FEET 350 COPPER DUCT MATERIAL: MAGNETI C I NSULATI ON TYPE: PVC INSULATION CLASS: THWN +/- I MPEDANCE: 0.0378 + J 0.0491 OHMS/1000 FT 1.19 + 1 1.55 PU ZO I MPEDANCE: 0.1191 + 1 0. 1209 OHMS/1 000 FT 3. 75 + J 3.80 PU FOR MSNI FPL BUS SWBD MSNI 5 480 50.0 FEET 750 COPPER DUCT MATERIAL: MAGNETI C I NSULATI ON TYPE: PVC INSULATION CLASS: THWN +/- I MPEDANCE: 0.0216 + J 0.0445 OHMS/1000 FT 0. 0938 + J 0.1931 PU ZO I MPEDANCE: 0.0680 + J 0.1095 OHMS/1000 FT 0.2951 + J 0. 4753 PU ------------------------------------------------------------------------------ GENERATION DATA BUS ------------------------------------------------------------------------------ NAME GENERATION VOLT SIZE INITKW MAXKVAR TYPE FPL BUS FPL 1 PU SB THREE PHASE CONTRI BUTI ON: 31000. 0 AMPS X/R : 8.00 LINE TO EARTH CONTRIBUTION: 31000. 0 AMPS X/R : 8. 00 POS SEQUENCE I MPEDANCE ( 100 MVA BASE) 0. 4813 + J 3. 85 PU ZERO SEQUENCE I MPEDANCE ( 100 MVA BASE) 0. 4813 + J 3.85 PU --------------------------------------------------------------------------- F A U L T A N A L Y S I S S U M M A R Y ------------------------------------------------------------------------------- BUS NAME VOLTAGE AVAILABLE FAULT CURRENT L-L 3 PHASE X/R LINE/GRND X/R CT*4 VFD 480. 19444.4 2.8 15984.17 2.1 FPL BUS 480. 31000.0 8.0 31000.00 8.0 MCCN BUS 480. 20525.1 3.2 17250. 04 2.4 SWBD MSN1 480. 29452.5 7.0 28728.71 6.4 FAULT ANALYSIS REPORT COMPLETED Roma Poww & UDM C=PNW, P.O. 0010"100, Miami. FL MOM 00 FPL June 29, 2010 Mr. Dennis Q. Davis Smith Seclanan Reid, Inc. 600 West Hillsboro Blvd. Deerfield Beach, Florida 33441 Re: Symmetrical Fault Current for FPL Project Name: 1232017 Facilities TCC Name: CT*4.tcc Dear Mr. Davis: Reference Voltage: 480 V Current Scale: X 1000 You recently requested symmetrical fault current information at the FPL facilities at two ----------------------------------------------------------------------------------------- locations on the main campus of South Miami Hospital. As such, the information is as follows: CAPTOR (Computer Aided Plotting for Time Overcurrent Reporting) 2-1500 kVA transformers in parallel, with a secondary voltage of 2771480 V in the main vault. COPYRIGHT SKM SYSTEMS ANALYSIS, INC. 1983-2006 The symmetrical fault current at this facility Is 54,000 Amps. This is calculated with an actual ----------------------------------------------------------------------------------------- impedance of 4.8% on each of the transformers. This assumes an infinite bus at the vault. Device Name: MCB MSNI TCC Name: CT*4.tcc MSN1 Bus Name: SWBD MSNI Bus Voltage: 480.OV The 1500 WA transformer in the same vault has a symmetrical fault current of 31,000 Amps. Function Name: Phase This also assumes an infinite bus at the transformer with an actual impedance of 4.90A. Manufacturer: SQUARED Description: LI, 1800-2000A Sub Type: PE, MicrologIc The 1000 WA transformer in the North Tower vault has a symmetrical fault current of 22,000 AIC Rating: lOOkA Overrlde:18 Amps. The same assumptions apply with an actual impedance rating of 4.89% Frame: PE 480V 2000A Curve Multiplier: 1 The FPL equipment currently serving or planned to serve your facility may change over time as Sensor: 2000A a result of any number of factors, including but not limited to transformer replacements due to Plug: 2000A load growth, electrical grid changes or emergencies. As a result, although we are providing you Setting: 1) LTPU (0.5-1.0 x P) 1.0 (2000A) with this information for the sole purpose of assisting you in the -completion of your study, you MCCN 2) LTD (2-24 Sec.) 7.0 should not design, install or operate your system in reliance upon any expectation that the specific size and type of equipment currently in place will remain so. If and when the size and -------- 3) INST (2-6 x P) 6.0 (12000A) type of the equipment changes, our employees are not always in a position to immediately notify --------------------------------------------------------------------------------- customers. Device Name: CB MCCN TCC Name: CT*4.tco This calculated symmetrical fault current is not intended for use as the basis for motor starting m Bus Name: SWBD MSNI Bus Voltage: 480.OV calculations and does not include consideration for any motor contribution or fault current Function Name: Phase asymmetry. Manufacturer: SQUARE D Description: LI, 100-800A C/) Sub Type: ME, Mlcrologic ANYONE USING OR RELYING ON THIS INFORMATION DOES SO AT THEIR OWN RISK, M AIC Rating: 65kA AND FLORIDA POWER & LIGHT COMPANY DISCLAIMS ANY LIABILITY FOR EITHER Frame: ME 480V 800A Curve Multiplier: I NEGLIGENCE OR WARRANTY ARISING THERE FROM. 0 Sensor: BOOA I z Plug: 600A If you have any questions or concerns please call me at (305) 552-2507. 0 Cl) Setting: 1) LTPU (0.5-1.0 x P) 1.0 (600A) SiWncely 2) LTD (2-24 Sec.) 16 3) INST (2-12 x P) 8.0 (4800A) ----------------------------------------------------------------------------------------- ector.). Maestri, C.E.M. Device Name: CB CT*4 TCC Name: CT#4.tcc Major Account Manager Bus Name: MCCN BUS Bus Voltage: 48O.OV Function Name: Phase an Fft Gm* cmwny Manufacturer: SQUARE D Description: 150-250A Sub Type: Powerpaot JJ AIC Rating: 65kA Frame: JJ 480V 250A Curve Multiplier: I Trip: 200A Setting: 1) Thermal Curve 2) Im LO (1OOOA) ----------------------------------------------------------------------------------------- ELECTRICAL DRAWING INDEX Device Name: CT-4 TCC Name: CT*4.tcc Bus Name: CT#4 DISCONNECT Bus Voltage: 480V Description: Motor Starting Curve Inrush: 6.0 (462.0A) NO. SHEET TITLE Rated Size: 60HP 0 of I Plotted) FLA+Load Adder: 77.OA + O.OA 1 OOK Power Factor: 1.000 Starting Time: 10.00s Efficiency: 0.80 Full Voltage (Curve) EO.Ol ELECTRICAL LEGEND. STUDIES & DRAWING INnFY CT#4.tcc Ref. Voltage: 480 Current in Amps x 1 CT#4.drw (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com irin Certification - EB-0000857 John E. Moulder PE - 33200 Mchael A. Steward PE - 65701 SSR JOB # 1232017.0