13-1288-016
r---------------------------------------------- 1 PAVILION SWITCHBOARD 2000A 600A ----------------------------------------- 8 # 350 KCMIL + 2 # 1/0 GND IN 2-3"C NDPA' 600A 4 # 4/0 + 1 # 4 GND IN 21/2 "C PANEL 'NHlB' 200A T-- 3#6+1#10GNDINVC 30 KVA -02!M XFMR k-kft� #8 GND 4 # 3 + I # 8 GND IN I 1/4-C PANEL 1NLCF1 , 100A 1 1! 11" i M1 NTS. NOTE: 1. A: DENOTES EXISTING PANEL USED FOR THIS PROJECT. 2. ALL PANELS AND FEEDERS ARE EXISTING TO REMAIN. TYPE: SQUARE D EXISTING PANEL" 1NLCF1 MAIN BUS: 100 AMP SERVICE- 3PH, 4W, 60HZ FAULT CURRENT- 1754 AMPS NEUTRAL: 100 AMP VOLTAGE 120/208 FULLY RATED EQUIPMENT SHORT CIRCUIT RATING: MANS: LUGS ONLY MOUNTING: SURFACE 10000 AMPS SYMMS. @ 208 V. (11I LISTED) LOCATION: TOP DEMAND NO DEM. CONDUIT WIRE TRIP POLES LOAD DESCRIPTION CKT PHASE CKT LOAD DESCRIPTION POLES TRIP WIRE CONDUIT NO DE M. DEMAND LOAD VA LOAD VA SIZE AMP AND REMARKS NI A B C NO. AND REMARKS AMP SIZE LOAD VA LOAD VA 0 0 900 900 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 360 600 0 0 1200 900 900 600 360 360 600 720 360 720 900 0 0 0 0 0 0 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- 1- RECEPT. -1 -3 -5 -7 -9 -11 -13 -15 -17 -19 -21 -23 -25 -27 -29 -31 -33 -35 -37 -39 -A-++ +-B-+ ++-C- -A-++ +-B-+ - F -j- -c- -A-++ +-B-+ ++-C- -A-++ +-B-+ ++-C- -A-++ +-B-+ ++-C- -A-++ +-B-+ -F-F-c- -A-++ +-B-+ 1 -F-F-C- 2- 4- 6- 8- 10- 12- 14- 16- 18- 20- 22- 24- 26- 28- 30- 32- 34- 36- 38- 40- 1 42-1 BREWER -2 -2 -2 -1 -1 -1 -1 -1 -1 -1 -2 -1 -1 -1 -1 -1 -1 30 30 30 20 20 20 20 20 20 20 30 20 20 20 20 20 1 20 10 10 10 12 12 12 12 12 12 12 10 12 12 12 12 12 1 12 3/4 314 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 314 314 3/4 3/4 3/4 3/4 1 3/4 1800 1800 1800 1800 1800 1800 0 0 360 560 0 360 900 1700 1700 0 0 0 0 0 1 01 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 REFRIG. BREWER WEST BLENDER EXPRESSO MACH. EAST BLENDER EXPRESSO MACH. ICE MACH. FUT. EXPRESSO EAST UCF. FUT. EXPRESSO UCR SPARE DISPLAY CASE SPARE P.O.S. SPARE EAST COUNTER REC. LTS. FCU-1 SPARE COW. REC. RECEPTION RECS. MONITORS TEMP. FLOWER CASE GIFT SHOP RECS. NEW FLOWER CASE RELOCATEDATM SPACES SPACE SPACES SPACE SPACES SPACE SPACES SPACE SPACES SPACE SPACES —1-41 SPACE 1800 8580 = SUB - TOTALS SUB - TOTALS = 16380 0 1800 VA DEMAND LOAD 24960 VA: NO DEMAND LOAD LOAD PER PHASE 7940 VA PRASE "A" 9020 VA PHASE "B" 9800 VA PHASE "C' PANELBOARD TOTAL LOAD = 26760 VA ft = VOLTAMPERE/ VOLT = 74 AMP FEEDER: SEE RISER DIAGRAM FED FROM SEE RISER DIAGRAM 26760 VA: TOTAL LOAD 26760 VA: TOTAL REMARKS: 1. PROVIDE GROUNDING BAR KIT 2. TEMPORARY FLOWER CASE IS TO BE IN OPERATION DURING CONSTRUCTION OF GIFT SFIOPAREA AND NEW FLOWER CASE 3. BOLD LETTERS REPRESENT ADDED DEVICES AND WORK ASSOCIATED WITH THIS PROJECT. A R C, H I T-F GT: Ct ba BERMELLO AJAMIL & PARTNERS, INC. Arcmruture Engineering manning lnteri& Design Landscape Architecture 26C1 S-cuth Sayshore Drive 10th Floor Miami, Florida 33133 (305) 859-2050 Fax (305) 860-3700 LOUIS J. AGUIRRE & ASSOCIATES, P.A. C o n s u l t i n g Engineers 9150 South Dadeland Blvd. - Suite 900 Miami ® Florida 33156 * CA 924 Telephone 305.670.0141 Facsimile 305.670.0144 www.ligapa.com Project No.: 23069 -.�LECTPICAL�7 LLI V—rr— b'PQ,2,k-- E. ,-z'11642 CONSTRUCTION DOCUMENTS REVISIONS: PROJECT NAME: SMH - LOBBY FLOOR REPLACEMENT & GIFT SHOP RENOVATION PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 11 COMM. NO. 40071.000 SCALE: DATE: 08-28-2013 DRAWN: CHECKED: BH CADD FILE: HJNSTITUTIONAL DRAWING TITLE: POWER RISER DIAGRAM AND PANEL SCHEDULE ELECTRICAL SHEET NO. 11