13-1288-004SYMBOL LEGEND ONE HOUR FIRE RATED PARTITION 2= r mm ONE HOUR FIRE RATED/ SMOKE PARTITION TWO HOUR FIRE RATED PARTITION MIM ") I 1 111110 TWO HOUR FIRE RATED/ SMOKE PARTITION OEM THREE HOUR FIRE RATED/ SMOKE PARTITION FOUR HOUR RATED/ SMOKE PARTITION EXIT LIGHT (CENTER ON DOOR(S)) NOTE: SHADED AREA INDICATES LIGHTED FACE EXIT LIGHT: DIRECTIONAL (CENTER ON DOOR(S) AS REQUIRED) NOTE: SHADED AREA INDICATES LIGHTED FACE LIFE SAFETY GENERAL N O-1 ES n.1 1. THIS SHEET SHOWS LIFE SAFETY EXITING DURING CONSTRUCTION OF THE PROJECT DUE TO TEMPORARY WALL NO NEW WALLS OR DOORS ARE BEING CONSTRUCTED THAT WILL ALTER EXITING ROUTES TO THE EXISTING HOSPITAL THEREFOR, A- FULL- pff- wzw PLAN IS NOT PART OF THE PACKAGE OF THESE CONSTRUCTION DOCUMENTS.-- GENERAL LIFE SAFETY CRITERIA A. CODES: APPLICABLE CODES: • FLORIDA BUILDING CODE 2010 • FLORIDA ACCESSIBILITY CODE 2012 • FLORIDA TEST PROTOCOLS (HIGH VELOCITY HURRICANE ZONES) 2010 • FLORIDA MECHANICAL CODE 2010 • FLORIDA PLUMBING CODE 2010 • FLORIDA GAS CODE 2010 • AIA GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND HEALTH CARE FACILITIES - 2010 EDITION • FLORIDA FIRE PREVENTION CODE/NFPA 101 - 2009 CHAPTER 19, EXISTING HEALTH CARE OCCUPANCIES • NFPA 70 - 2008 • NFPA 253 - 2006 • NFPA 13 - 2007 STANDARD FOR INSTALLATION OF SPRINKLER SYSTEM • NFPA 14 - 2007 STANDARD FOR THE INSTALLATION OF STANDPIPE, PRIVATE HYDRANTS, AND HOSE SYSTEMS. • NFPA 72 - 2007 (NEC) NATIONAL FIRE ALARM CODE B. OCCUPANCY: OCCUPANCY TYPE: • INSTITUTIONAL (FLORIDA BUILDING CODE 2010 - SECTION 308.3 GROUP 1-2) C. CLASSIFICATION: BUILDING CLASSIFICATION: • TYPE [-A FULLY SPRINKLERED (FBC 2010) TABLE 601 • NFPA 220 - TYPE 1 (443) D. BUILDING TYPE: (CLASSIFIED BY TYPE OF CONSTRUCTION) FBC SEC. 5 CRITERIA OUTLINED BELOW IS TYPICAL FOR ALL OCCUPANCIES AND BASED UP CRITERIA OF A FULLY SPRINKLERED BUILDING. 1. TYPE OF CONSTRUC11ON: (TYPE I-A) FULLY SPRINKLERED IN ACCORDANCE WITH 903.3.1 2. STRUCTURE OF EXISTING (I-A) = FBC EXISTING BUILDINGS. CHAPTER 4 (407 AND 419) 3. ALLOWABLE HEIGHT=UNLIMITED (FBC TABLE 503) 4. MAX NO. OF STORIES = UNLIMITED (FBC TABLE 503) 5. ALLOWABLE BUILDING AREA = UNLIMITED (TABLE 503) E. OCCUPANCY LOAD: FBC SEC. 10 (TABLE 1004.1.1)/NFPA TABLE 7.3.1.2 1. PRIMARY OCCUPANCY (INSTITUTIONAL - INPATIENT TREATMENT): 240 SF GROSS 2. ACCESSORY OCCUPANCY (INSTITUTIONAL - OUTPATIENT AREAS): 100 SF GROSS 3. ACCESSORY OCCUPANCY (BUSINESS) 100 SF GROSS 4. ACCESSORY OCCUPANCY (ASSEMBLY - 2) 15 SF/P G. TRAVEL DISTANCES / EXIT WIDTHS REQUIREMENTS: (FBC SEC. 10) THE REQUIREMENTS OUTLINED BELOW ARE BASED ON A FULLY SPRINKLERED BUILDING AND APPLICABLE OCCUPANT TYPES. 1. ALLOWABLE TRAVEL DISTANCES BY OCCUPANCY(FBC 1016.1): INSTITUTIONAL (1-2) a. MAX. TRAVEL DISTANCE TO EXIT- 200 FT. (FBC TABLE 1016.1). b. MAX TRAVEL DISTANCE TO EAT FROM RM DOOR. 150 FT. (NFPA 101) c. MAX DEAD END CORRIDOR : 20 FT. (FBC 1018.4/20 NFPA 19.2.5.2 d. MAX COMMON PATH OF TRAVEL- 75 FT./50 NFPA 101 2. EGRESS WIDTHS: a. LEVEL EAT. 0.2 IN. PER PERSON (FBC 1005.1) b. STAIRS: 0.3 IN. PER PERSON (FBC 1005.1) Q MIN. CORRIDOR WIDTH: 44 IN. (FBC 1018.2) d. CLEAR OPENING DOOR EXIT- 32 IN. (FBC 1008.1.1) e. MIN. STAIR WIDTH 44 IN. (FBC 1009.1) 3. VERTICAL EXIT ENCLOSURES a.1 HR. CONNECTING 3 STORIES OR LESS / 2 HR. CONNECTING 4 OR MORE STORIES. (FBC 1022.1) 4. EXIT PASSAGEWAYS a. WIDTH = 44-IN. MIN. (FBC 1023.2) b. CONSTRUCTION = I HR. MIN BUT NOT LESS THAN THAT REQUIRED FOR ANY CONNECTING EAT ENCLOSURES (FBC 1023.3) c. OPENINGS AND PENETRA11ONS = ONLY FROM EXIT ACCESS FROM NORMALLY OCCUPIED SPACES. (1023.5) AS REQ. BY FBC 715. d. PENETRATIONS = NP EXCEPT MEN SERVING EXIT PASSAGEWAY H. INTERIOR FINISHES: (FBC SEC. 8) THE REQUIREMENTS OUTLINED BELOW ARE BASED UPON A FULLY SPRINKLERED BUILDING AND APPLICABLE OCCUPANT TYPES. CLASS A - FLAME SPREAD - 00-25 SMOKE DEVELOPMENT - 0-450 CLASS B - FLAME SPREAD - 26-75 SMOKE DEVELOPMENT - 0-450 CLASS C - FLAME SPREAD - 76-200 / SMOKE DEVELOPMENT - 0-450 1. EAT ENCLOSURES AND EXIT PASSAGEWAYS a. INSTITUTIONAL 1-2. CLASS B 2. CORRIDORS a. INSTITUTIONAL 1-2: CLASS B 3. ROOMS AND ENCLOSED SPACES a. INSTITUTIONAL 1-2 CLASS B *CLASS C ON ADMINISTRATIVE SPACES *CLASS C ON ROOMS WITH CAPACITY FOR FOUR PERSONS OR LESS. AREA SMOKE COMPARTMENTS S.F. ARCHITECT: BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning inte6or DQsign Landscape Architecture 2601 9Q6th Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859-2050 Fax (305) 860-3700 LOUIS J. AGUIRRE & ASSOCIATES. PA Consulting Engineers 9150 South Dodeland Blvd. • Suite 900 Miami • Florida 33156 • EB0000924 Telephone 305.670.0141 Facsimile 305.670.0144 www.iigaRo.com x N1 Z4 6.5,7 PROJECT NAME: SMH - LOBBY FLOOR REPLACEMENT & GIFT SHOP RENOVATION PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 COMM. NO. 40071.000 SCALE: AS SHOWN DATE: 09-06-2013 DRAWN: JEC CHECKED: BH CADD FILE: KINSTITUTIONAL DRAWING TITLE: LIFE SAFETY FIRST FLOOR PLAN SHEET NO.