13-1221-031
I w Q Onm 0 w I- S U3 a 0 M 0 N N 0 H z a I- g w U x 0 r L 1 7 SYMBOL LEGEND SYMBOL SIMPLEX MODEL # DESCRIPTION QTY FACP 4100 -9111 FACP 250 PT 6 NAC 4A 120VAC, WITH VOICE FIRE N-A -cl 4009 -9201 NAC EXTENDER PANEL, IDNET, FAAP 4603 -9101 FIRE ALARM ANNUNICAT ❑R PANEL PULL T/C DUCT JACK F,B.❑, FI.RE ALARM TERMINAL CABINET (FURNISHED BY ELECTRICAL CONTRACTOR) DETECTOR RE Z1 MAGNETIC 4090 -9001 MONITOR INDIVIDUAL ADDRESS MODULE CONNECT TO N/O CONTACTS ONLY Iz- Z2 4090-9002 CONTROL INDIVIDUAL ADDRESS MODULE Z3 4090 -9118 RELAY IAM WITH T -SENSE INPUT - ADDRESSABLE MODULE 12 ao 4099 -9001 SINGLE ACTI ❑N ADDRESSABLE STATION F❑WP 2099 -9138 2975 -9211 4090 -9051 SINGLE ACTION STATI ❑N W.P. BACK BOX ENCAPSULATED ADDRESSABLE M ❑NIT ❑R IAM 42- MIN /48- MAX (NFPA; O 4098 -9792 4098 -9733 SSD SENSOR BASE SSD HEAT SENSOR EDITION (SECTION 5.13.4) O 4098 -9714 4098 -9792 SSD PHOTO SENSOR SSD SENSOR BASE ��- 4098 -9756 2098 -9799 SSD SENSOR DUCT HOUSING 4 WIRES SAMPLING TUBE 97" .E.E DU E�L K" LJ LG H.. ® 2088 -9007 MR101 RELAY, SPDT WITH LED 12 FS F.B.O. FLOW DETECTOR SWITCH FURNISHED BY DIVISION 15 TS F.B.❑. TAMPER (GATE VALVE) SWITCH FURNISHED BY DIVISI ❑N 15 �IVV- EOLR END OF LINE RESISTOR ® 2081 -9028 ISOLATED LOOP PROTECTOR FOR MAPNET LINE 75cd /110col 4906 -9127 A/V MULTI - CANDELA RED SYNC (IN MAIN BLDG, ONLY) M 180cd NS- 241575W -FR A/V MULTI - CANDELA RED SYNC (IN GARAGE ONLY) M WP 180cd ASWP- 2475W -FR WPBB WEATHRPR ❑OF HORN /STR ❑BE, 180CD WEATHERPROOF BACKBOX FOR HORN/STROBE 75c® 10cd 4906 -9101 V/❑ MULTI - CANDELA RED SYNC (IN MAIN BLDG. ONLY) 180cd RSS- 241575W -FR V/0 MULTI - CANDELA RED SYNC (IN GARAGE ONLY) ® 180ccd RSSWP- 241575W WEATHERPROOF V/O MULTI - CANDELA RED SYNC (IN GARAGE ONLY) Eg LED EL -1 SS EL -1 SS ELEVATOR WARNING SIGN FSD F.B.O. FIRE SMOKE DAMPER (FURNISHED BY OTHERS) M F.B.O. DAMPER FAN (FURNISHED BY OTHERS) = F.B.O. C❑NNECTI ❑N TO AN APPROVED, DEDICATED EARTHGR❑UND, NFPA 70. COMPLY WITH NEC. --� F.B.O. 120VAC SOURCE DEDICATED BREAKER COMPLY WITH NFPA 70. -� F.B.O. TELEPHONE LINE E EXISTING N NEW R RELOCATED 0 4902 -9721 SPPEAKER, WHITE TRUALERT FOR MASS NOTIFICATION USE ONLY AS -24MCW WHEELOCK MULTICANDELA HORN/STROBE, 2 -WIRE SYNC RSS -24MCW WHEELOCK MULTICANDELA STROBE, 2 -WIRE SYNC SCOPE OF WORK NEW DEVICES ADDED SCOPE OF WORK NEW DEVICES ADDED WIRE LEGEND A = INITIATING DEVICE CIRCUIT - IDC 14/2 FPL MINIMUM. C = AUXILIARY CONTROL CIRCUIT - ACC , 14/2 FPL MINIMUM. ' L = NOTIFICATION APPLIANCE CIRCUIT - NAC 14/2 FPL MINIMUM, P = POWER CIRCUIT 14/2 FPL MINIMUM. N = DATA COMMUNICATIONS 18/2 TWISTED /SHIELDED PAIR FPL MN = MULTI - ADDRESSABLE PERIPHERAL NETW❑RK� - MAPNET 18/2 TWISTED /SHIELDED PAIR FPL MP = MAPNET POWER CIRCUIT - APC 14/2 FPL MINIMUM. 0 4009 - 4009-3201 WIRING ENTRIES INTO BACK BOX 00 Owl )!I 41000 4 LOW FACP WIRING ENTRIES INTO BACK BOX 00000 4010 4010 FACP WIRING ENTRIES INTO BACK BOX 4006/4008 ) •008400B FACP WIRING ENTRIES INTO BACK BOX DEVICE MOUNTING HEIGHTS A/C SUPPLY DIFFUSER CEILING D SMOKE/HEAT DETECTOR 3 (MIN) BELOW CEILING4' MIN HANDICAP I, l AUDIOVISUAL ACCEPTED HERE 7MOUNTED 12 (MAX BEDROOM STROBE VISUAL -ONLY • DEVICES IMPORTANT NOTE. • VERIFY EXACT MOUNT -NG REQUIREMENTS WITH MANUFACTURERS DATA SHEETS �5T I • ^ ^••••••• CAUTION ^-"" POWER -LIMITED AND NON-POWER -LIMITED WIRING MUST ENTER THROUGH SEPARATE CONDUIT/SERVK:E ENTRANCES AC POWER ENTRANCE INTO BACK BOX IS REQUIRED AT DESIGNATED LOCATION OF THE BACK BOX- FAILURE TO PROPERLY SEPARATE 12W NON- POWER. LIMBED WIRING FROM POWERIIMITED LOW VOLTAGE WIRING. WILL VOID THE UL LISTING FOR THE DEVICE AND WILL PREVENT THE INSTALLATION FROM BEING CERTIFIED (SEE CHART INSTALLATION INSTRUCTION SHEET ) NOTE: MEASUREMENTS 4 • - I SHOWN ARE TO THE CLOSEST OF THE DETECTOR. MORE THAN TWO VISIBLE APPLIANCES ARE NOT PERMITTED IN ANY FIELD OF VIEW UNLESS THEIR FLASHES AS SYNCHRONIZED. NFPA 72 2007 EDITION (SECTION 7.5.4.3.2) BO- MIN 96' MAX NFPA 722007 EDITION (SECTION 7.5.4.1) LESS I WALL 'jI E I SIDE WALL NOTES: 1. FIRE ALARM SYSTEM SHALL BE POWER LIMITED UTILIZING POWER LIMITED WIRING.. 2. WIRING SHALL BE #12 THHN, #14 THHN OR 18/2 TWISTED SHIELDED PAIR FPL TYPE CABLE. 3. INSTALLATION SHALL COMPLY WITH NFPA 1, 2009, APPLICABLE CHAPTERS. 4. INSTALLATION SHALL COMPLY WITH NFPA 72, 2007, APPLICABLE CHAPTERS. 5. INSTALLATION SHALL COMPLY WITH NFPA 101, 2009, APPLICABLE CHAPTERS. 6. INSTALLATION SHALL COMPLY WITH NEC 2008. 7. CONDUIT, AS APPLICABLE SHALL BE 1/2" MINIMUM WITH A MAXIMUM FILL OF 40 %. COMPLY WITH NEC. 8. SYSTEM SHALL BE GROUNDED PER MANUFACTURERS SPECIFICATIONS. 9. ALL DEVICES SHALL BE COMPATIBLE & SHALL BE UL LISTED FOR FIRE SERVICE USE. 10. ALL SPACES SHALL MEET THE AUDIBLE CHARACTRISTICS OF NFPA 72 AND NFPA 101. 11. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 3' OF A/C DIFFUSERS, KITCHEN OR BATHROOM DOORS. 12. CEILING MOUNTED DEVICES SHALL BE LOCATED AT A HEIGHT OF 10' +/- ON SMOOTH FLAT CEILINGS UNLESS OTHERWISE NOTED. 13. SIGNALLING LINE CIRCUITS SHALL HAVE A MAXIMUM OF 127 POINTS PER CHANNEL. SEE FLOOR PLANS FOR QUANTITIES & TYPES OF DEVICES. 14. FIRE ALARM PANEL & ANY ASSOCIATED FIRE ALARM TRANSPONDERS SHALL BE FED BY A 120VAC, SINGLE PHASE, 20 AMP, DEDICATED BREAKER. 15. ALL INTERCONNECTED FIRE ALARM PANELS SHALL BE ARRANGED TO FUNCTION AS A SINGLE SYSTEM AND SHALL BE MONITORED FOR INTEGRITY PER NFPA 72. 16. RACKS, SHELVES AND EQUIPMENT ARE ALL LOWER THAN 80" ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED. 17. THE DESIGN INSTALLATION COMPLIES WITH FLORIDA BUILDING CODE - 2010 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. 18. THIS FACILITY IS FULLY SPRINKLED WITH THE EXCEPTION OF THE ELEVATOR SHAFT. 19. THIS IS AN FIVE STORY BUILDING. 20. ROOM CONTAINING FACP AND /OR BOOSTER POWER SUPPLY PANEL(S) IS MECHANICALLY VENTILATED. 21. MAXIMUM MOUNTING HEIGHT FOR ALL PANELS SHALL BE SIX FEET TO THE TOP OF THE ENCLOSURE. 22. MIMIMUM CLEAR WORKING SPACE OF THREE FEET IN FRONT OF ALL FIRE ALARM PANELS SHALL BE PROVIDED. SCOPE OF WORK: 1. PROVIDE & INSTALL FIRE ALARM SYSTEM AS SHOWN ON DRAWINGS. 2. SIGNALING LINE CIRCUIT WIRING SHALL BE STYLE 4. 3. NOTIFICATION APPLIANCE CIRCUIT WIRING SHALL BE STYLE Y. 4. THIS SYSTEM IS MONITORED BY AN EXISTING REMOTE SUPERVISORY STATION PER NFPA- 72.8.5. SEQUENCE OF OPERATION: UPON ACTIVATION OF ANY MANUAL STATION THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. UPON ACTIVATION OF ANY AUTOMATIC DEVICE THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTORS (WITH THE EXCEPTION OF THE ELEVATOR LOBBY DETECTOR AT THE PRIMARY LEVEL OF EGRESS), THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM 1S SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTOR AT THE PRIMARY LEVEL OF EGRESS, THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE ALTERNATE LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. UPON ACTIVATION OF THE ELEVATOR MACHINE ROOM SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL BLINK. UPON ACTIVATION OF THE ELEVATOR TOP OF SHAFT SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL BLINK. UPON ACTIVATION OF A WATERFLOW SWITCH, THE FOLLOWING SHALL OCCUR. 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. THE WATER FLOW BELL SHALL ACTIVATE UPON WATER FLOWING ONLY. 7. THE WATER FLOW BELL SHALL CONTINUE TO SOUND AS LONG AS WATER IS FLOWING. 8. THE WATER FLOW BELL SHALL NOT BE SILENCEABLE FROM THE FACP. UPON ACTIVATION OF A TAMPER SWITCH, THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. UPON ACTIVATION OF A DUCT SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 3. THE AIR HANDLER UNIT ASSOCIATED WITH THAT DUCT DETECTOR SHALL SHUT DOWN. 4. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. UPON ACTIVATION OF THE ELEVATOR TOP OF SHAFT, OR ELEVATOR MACHINE ROOM HEAT DETECTOR, THE FOLLOWING SHALL OCCUR: 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 3. ELEVATOR SHALL LOSS POWER (SHUNT TRIP). MASS NOTIFICATION NOTES & SEQUENCE OF OPERATIONS .10111:63 1. MASS NOTIFICATION SPEAKER WILL NOT WORK IN CONJUNCTION WITH FIRE ALARM SYSTEM HORNS. 2. IN THE EVENT OF A FIRE ALARM BEING ACTIVATED AND MASS NOTIFICATION IS NEEDED, MASS NOTIFICATION WILL OVERRIDE THE HORN OF FIRE ALARM AND SPEAKERS WILL BE ACTIVATED TO DIRECT INDIVIDUAL WITHIN FACILITY. SEQUENCE OF OPERATION UPON ACTIVATION HANDHELD MICROPHONE AT PANEL. 1. ALL SPEAKERS WILL BE ACTIVATED BY DESIGNATED FLOOR AT THE MAIN PANEL USING SWITCHES. T�I1 G��� : 4•i^ Iln •'• vn • �a YvL'Yd��► • ". INGEMEL S.A. ENGINEERING COMPANY i T^ Pedro Arias, P.E. No. 63813 State of Florida CA No. 9113 20871 Johnson Street Street, Suite 115 Phone: (954) 318 -2264 Fax: (954) 450 -7216 r Pembroke Pines, Florida 33029 :n 0 FIRE 4ANUAL 6 PHONE PULL w z O_ w DUCT JACK TATION DETECTOR RE MAGNETIC RD10TE TEST Iz- N �LJL HOLDER ao o 48- MAX (ADA LU 42- MIN /48- MAX (NFPA; NFPA 72 2007 EDITION (SECTION 5.13.4) WALL 'jI E I SIDE WALL NOTES: 1. FIRE ALARM SYSTEM SHALL BE POWER LIMITED UTILIZING POWER LIMITED WIRING.. 2. WIRING SHALL BE #12 THHN, #14 THHN OR 18/2 TWISTED SHIELDED PAIR FPL TYPE CABLE. 3. INSTALLATION SHALL COMPLY WITH NFPA 1, 2009, APPLICABLE CHAPTERS. 4. INSTALLATION SHALL COMPLY WITH NFPA 72, 2007, APPLICABLE CHAPTERS. 5. INSTALLATION SHALL COMPLY WITH NFPA 101, 2009, APPLICABLE CHAPTERS. 6. INSTALLATION SHALL COMPLY WITH NEC 2008. 7. CONDUIT, AS APPLICABLE SHALL BE 1/2" MINIMUM WITH A MAXIMUM FILL OF 40 %. COMPLY WITH NEC. 8. SYSTEM SHALL BE GROUNDED PER MANUFACTURERS SPECIFICATIONS. 9. ALL DEVICES SHALL BE COMPATIBLE & SHALL BE UL LISTED FOR FIRE SERVICE USE. 10. ALL SPACES SHALL MEET THE AUDIBLE CHARACTRISTICS OF NFPA 72 AND NFPA 101. 11. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 3' OF A/C DIFFUSERS, KITCHEN OR BATHROOM DOORS. 12. CEILING MOUNTED DEVICES SHALL BE LOCATED AT A HEIGHT OF 10' +/- ON SMOOTH FLAT CEILINGS UNLESS OTHERWISE NOTED. 13. SIGNALLING LINE CIRCUITS SHALL HAVE A MAXIMUM OF 127 POINTS PER CHANNEL. SEE FLOOR PLANS FOR QUANTITIES & TYPES OF DEVICES. 14. FIRE ALARM PANEL & ANY ASSOCIATED FIRE ALARM TRANSPONDERS SHALL BE FED BY A 120VAC, SINGLE PHASE, 20 AMP, DEDICATED BREAKER. 15. ALL INTERCONNECTED FIRE ALARM PANELS SHALL BE ARRANGED TO FUNCTION AS A SINGLE SYSTEM AND SHALL BE MONITORED FOR INTEGRITY PER NFPA 72. 16. RACKS, SHELVES AND EQUIPMENT ARE ALL LOWER THAN 80" ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED. 17. THE DESIGN INSTALLATION COMPLIES WITH FLORIDA BUILDING CODE - 2010 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. 18. THIS FACILITY IS FULLY SPRINKLED WITH THE EXCEPTION OF THE ELEVATOR SHAFT. 19. THIS IS AN FIVE STORY BUILDING. 20. ROOM CONTAINING FACP AND /OR BOOSTER POWER SUPPLY PANEL(S) IS MECHANICALLY VENTILATED. 21. MAXIMUM MOUNTING HEIGHT FOR ALL PANELS SHALL BE SIX FEET TO THE TOP OF THE ENCLOSURE. 22. MIMIMUM CLEAR WORKING SPACE OF THREE FEET IN FRONT OF ALL FIRE ALARM PANELS SHALL BE PROVIDED. SCOPE OF WORK: 1. PROVIDE & INSTALL FIRE ALARM SYSTEM AS SHOWN ON DRAWINGS. 2. SIGNALING LINE CIRCUIT WIRING SHALL BE STYLE 4. 3. NOTIFICATION APPLIANCE CIRCUIT WIRING SHALL BE STYLE Y. 4. THIS SYSTEM IS MONITORED BY AN EXISTING REMOTE SUPERVISORY STATION PER NFPA- 72.8.5. SEQUENCE OF OPERATION: UPON ACTIVATION OF ANY MANUAL STATION THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. UPON ACTIVATION OF ANY AUTOMATIC DEVICE THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTORS (WITH THE EXCEPTION OF THE ELEVATOR LOBBY DETECTOR AT THE PRIMARY LEVEL OF EGRESS), THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM 1S SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTOR AT THE PRIMARY LEVEL OF EGRESS, THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE ALTERNATE LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. UPON ACTIVATION OF THE ELEVATOR MACHINE ROOM SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL BLINK. UPON ACTIVATION OF THE ELEVATOR TOP OF SHAFT SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL BLINK. UPON ACTIVATION OF A WATERFLOW SWITCH, THE FOLLOWING SHALL OCCUR. 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS SILENCED. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. THE WATER FLOW BELL SHALL ACTIVATE UPON WATER FLOWING ONLY. 7. THE WATER FLOW BELL SHALL CONTINUE TO SOUND AS LONG AS WATER IS FLOWING. 8. THE WATER FLOW BELL SHALL NOT BE SILENCEABLE FROM THE FACP. UPON ACTIVATION OF A TAMPER SWITCH, THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. UPON ACTIVATION OF A DUCT SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 3. THE AIR HANDLER UNIT ASSOCIATED WITH THAT DUCT DETECTOR SHALL SHUT DOWN. 4. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. UPON ACTIVATION OF THE ELEVATOR TOP OF SHAFT, OR ELEVATOR MACHINE ROOM HEAT DETECTOR, THE FOLLOWING SHALL OCCUR: 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP & REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS LISTED CENTRAL STATION VIA DACT. 3. ELEVATOR SHALL LOSS POWER (SHUNT TRIP). MASS NOTIFICATION NOTES & SEQUENCE OF OPERATIONS .10111:63 1. MASS NOTIFICATION SPEAKER WILL NOT WORK IN CONJUNCTION WITH FIRE ALARM SYSTEM HORNS. 2. IN THE EVENT OF A FIRE ALARM BEING ACTIVATED AND MASS NOTIFICATION IS NEEDED, MASS NOTIFICATION WILL OVERRIDE THE HORN OF FIRE ALARM AND SPEAKERS WILL BE ACTIVATED TO DIRECT INDIVIDUAL WITHIN FACILITY. SEQUENCE OF OPERATION UPON ACTIVATION HANDHELD MICROPHONE AT PANEL. 1. ALL SPEAKERS WILL BE ACTIVATED BY DESIGNATED FLOOR AT THE MAIN PANEL USING SWITCHES. T�I1 G��� : 4•i^ Iln •'• vn • �a YvL'Yd��► • ". INGEMEL S.A. ENGINEERING COMPANY i T^ Pedro Arias, P.E. No. 63813 State of Florida CA No. 9113 20871 Johnson Street Street, Suite 115 Phone: (954) 318 -2264 Fax: (954) 450 -7216 r Pembroke Pines, Florida 33029 :n W c� G W V J VJ I..L W VJ - 0 C G Q G w O Z W O z 0 CL OC U w 0 L 0 0 J M i E S M LU F- U) � LLU M Q C) O Lij Ycj LL M IZ' m ~ C<C G 2 0 ~ O � U) � O DRAWN BY: J.SERRANO CHECKED BY: J.SERRANO ISSUE DATE: 8/19/13 JOB #: PROJECT #: 263:972023611 SIMPLEXGRINNELL© 2013 SYSTEM: FIRE ALARM SYSTEM SHEET: GENERAL INFORMATION FA -002 w z O_ w C3\ � 1�' RE Iz- o WNW N �LJL ►- 0 w U U U ao LU W c� G W V J VJ I..L W VJ - 0 C G Q G w O Z W O z 0 CL OC U w 0 L 0 0 J M i E S M LU F- U) � LLU M Q C) O Lij Ycj LL M IZ' m ~ C<C G 2 0 ~ O � U) � O DRAWN BY: J.SERRANO CHECKED BY: J.SERRANO ISSUE DATE: 8/19/13 JOB #: PROJECT #: 263:972023611 SIMPLEXGRINNELL© 2013 SYSTEM: FIRE ALARM SYSTEM SHEET: GENERAL INFORMATION FA -002