13-1221-016Miami -Dade Fire Rescue MIAM DADE Fire Alarm Pre - Submittal Checklist Desigoed by: to n YES NO IN/Al Signature: LOCATION /COMMENTS A location key is provided showing the area of proposed work with in the building. Also a site key with X 26 north arrow for projects with multiple buildings showing locations of all buildings with addresses. Floor plans are drawn to 1/8' scale or, if using another scale, all service coverage is diagrammed on the X 27 plan and all room dimensions are included. 28 All rooms and spaces are labeled indicating their use. Also, for all assembly use rooms with an occupant X load of SO or greater the occupant load has been provided. 291 All new existing, relocated or replaced devices are indicated on the floor plan & riser. X 30 Ceilin type /condition and height is provided for all ceiling mounted devices. X All devices in areas in which the voltage, temperature, and humidity variations exceed those conditions X 31 stated in NFPA 72, are listed for conditions and all such areas are identified. 32 The FACP or remote annunciator is located at the main entrance/lobby. X 33 The FACP and all sub panels in unoccupied rooms are protected with a smoke detector. X If complete automatically activated system, there is at least 1 pull station on each floor or 2 for large X 34 buildings. if a manually activated system, the travel distance to reach a pull station is less than 200' feet and within S' X 35 feet of exits. All automatic initiating devices arc shown and are located in accordance with NFPA 72, the X 36 manufacturers specifications, and accepted engineering practices. All visual notification appliances are placed per the tablet in NFPA 72 and each strobe has It's candela X 37 rating listed on the floor plan and riser. All corridor spaced strobes are placed a maximum of 100' feet apart and within 15' feet from ends of the X 38 corridor. 39 All spaces meet the audible characteristics of NFPA 72 and NFPA 101. X Walls /partitions that do not extend to ceiling and racks, shelves and equipment, which may block X 40 devices, are shown with their heights indicated. Duct detectors or relays for duct detectors are shown on the floor plan and riser for all systems over 2000 X 41 • cfrn. These devices are powered by fire alarm system. 421 A riser diagram is provided showing each floor ol'building with all zones and circuits labeled. X 43 1 The wire size, type, and number of conductors are provided for each circuit of riser. X 44 The fire pump is monitored -for run, phase reversal & phase loss to _X_ a continuously manned X location, or _ the supervised fire alarm system. All relays for automatic extinguishing systems are shown on the floor plan and riser. (Hoods, booths, FM- X 4S 200, sprinkler, etc. The ampacity of each power supply and circuits is specified for each fire alarm control panel and NAC X 46 panel. Also, individual device current is specified on plans. The total footage to the last device is included with the voltage drop calculations for each notification X 47 appliance circuit of each power supply. 48 1 The wattage tap is indicated for all speakers. X 491 The wattage capacity and load calculation is provided for each amplifier. X All load values for stand -by and alarm used in calculations are highlighted on mfg. spec. sheets. Also, X SO ampacity of equipmeut/components and circuits is highlighted on mfg. spec. sleet This system includes Emergency Voice Evacuation and Is provided with 15 minutes of secondary alarm X 51 power. This system is being provided back cap power by an emergency generator and will provide 4 hours of X S2 standby power plus the appropriate secondary alarm power. Battery calculations, detailed in chart form, showing all information required per NFPA 72 4.4.1.5.3.1 X S3 are provided for each back-up power supply. Desigoed by: to n IflevtoYr Phone # : q Sl ` 9&2_5_z23 Signature: Created by: ZGH 03 /07