13-1221-009S.Simplex 410011L.J Multi -Point Peripherals UL, ULC Listed, FM, CSFM 4090 -9118 Relay IAM (Individual and MEA (NYC) Approved* Addressable Module) with T -Sense Input M Dual point operation provides a supervised multi -state input and a relay output in a single package using only one address: • Typical applications are for damper motor control with dual damper position feedback monitoring (open and closed) • For use with Simplex 4100U Fire Alarm Control Panels operating with software revision 11 or higher and providing IDNetTM communications ** Input/Output details: • Input operation is "T- Sense" and provides supervised monitoring of normally open, dry contacts • Status conditions are Normal, Open Circuit (trouble condition), Current Limited (position input 1), and Short (position input 2) • Total wiring distance to supervised contacts is up to 500 ft (152 m); for indoor wiring applications • Both data and power are provided by the IDNet communications link over a single wire pair • Form C relay output is rated 2 A @ 30 VDC, and 1/2 A @ 120 VAC (resistive ratings) Compact, sealed construction: • Enclosed design minimizes dust infiltration • Mounts in standard 4" square electrical box • Visible LED flashes to indicate communications • Screw terminals for wiring connections • Optional covers are available to allow LED to be viewed after installation UL Listed to Standard 864 Descrintin Single Address Dual Point Module. The 4090 -9118 Relay IAM with T -Sense allows a Simplex 410OU IDNet communication channel to monitor two input contact closures with one point and control an output relay with the other point, both from a compact module requiring a single address. Module power is supplied from the IDNet communications channel eliminating the need for separate power wiring. Multi -Point Device Description. The input circuit and relay operation are controlled independently and may be disabled separately. Point association is determined at the 410OU host panel. At the 410OU host display, the device address is designated as a single hardware location (such as 1 -1). The individual points are considered "sub- points" and are layered underneath (such as 1 -1 -1 and 1 -1 -2). " IDNet addressable communications designs are protected by U.S. Patent No. 4,796,025. 4090 -9118 Relay IAM with T -Sense Input (shown approximately 1/2 size) Supervised Input. The 4090 -9118 Relay IAM with T -Sense has a supervised input that monitors for continuity to an end -of -line resistor and can differentiate between a short circuit contact closure and a current limited contact closure. Four State Operation. Normal is when all contacts are open and there is continuity to the end -of -line resistor; Open is when continuity does not exist to the end -of -line resistor, causing a Trouble condition; Short, indicates that a contact has closed that is directly connected to the input circuit; and Current Limited indicates that a contact has closed beyond a series connected current limiting resistor. This operation allows differentiation between two different contact types due to their wiring location, and reporting as a single IDNet addressable point to a 410OU fire alarm control panel. Efficient Package. For smoke control applications, this module provides an efficient package for fan damper control with position feedback. The monitor point can be connected to two separate status indicator switches allowing the host panel to track the fan damper status with respect to the requested fan control operation. General Applications. The monitor and control points can be applied for a variety of associated or independent operations. Flexible programming abilities at the host panel can provide the association logic required for a wide variety of fire or utility operations. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300 - 0026:311 for allowable values and /or conditions concerning material presented in this document It is subject to re- examination, revision, and possible cancellation. Accepted for use — City of New York Department of Buildings — MEA35 -93E. Additional listings may be applicable; contact your local Simpiex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4090- 0007 -2 3/2004