13-04-010w
m
r � m
Cr_
z
w
..ter 5
w
mmn
M
W
Cal w,-
r
n n_
Y wp
` Q w
N i
I1..1A Z .1�a =: rf 6 cj
�,. cr M ~ (0 a R. °
20 c t T Z LLI
L
D w a
� raw
r
w
O v Q
z 1n
� a
` L m J
•(3) z w
zw
W
ci
yQ
�4
z
O
CL z
cc O
L) U
rn D
w w
z
O z O
0
'ANON- ADDRESSABLE MULTI - CANDELA VISIBLE NOTIFICATION APPLIANCE
4098 -9792 STANDARD SENSOR BASE T
rueAlert °
PRODUCT INFORMATION PRODUCT INFORMATION WHEN SURFACE MOUNTING USE 4" SQUARE x 1 -1/2" DEEP Box W
(WALL MOUNT) RED SKIRT NO. 4905 -9937 OR co
FEATURES: WHITE SKIRT NQ. 4905 -9940
FEATURES:
• UL LISTED, FM APPROVED 4 X 1 1/2" DEEP OCTAGONAL
• TRUEALARM ANALOG SENSING PROVIDES DIGITAL TRANSMISSION OF ANALOG UL LISTED TO STANDARD 1971 4905 -9931 ADAPTER PLATE Q 2975 -9145 BOX cc
SENSOR VALUES VIA MAPNETII, OR IDNet TWO WIRE COMMUNICATIONS OR 0
m U
• FIRE ALARM CONTROL PANEL PROVIDES: 4" SQUARE X 1 1/2" DEEP, WHICH REQUIRES • ADA COMPATIBLE ° � °
SELECTION FOR EACH SENSOR A 4098 -9832 ADAPTER PLATE (6 -3/8" X 1/4� SYNCHRONIZATION FLASH RATE MODE FOR USE WITH:
INDIVIDUAL SENSITIVITY SE BOX SUPPLIED BY CONTRACTOR � Lu
-PEAK VALUE LOGGING ALLOWING ACCURATE ANALYSIS FOR SENSITIVITY SELECTION • SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE
- AUTOMATIC ENVIRONMENTAL COMPENSATION 4905 -9(SH OPTIONAL WIRE o a
- DISPLAY OF SENSITIVITY IN PERCENT PER FOOT O FOR CLASS 8 OR CLASS A OPERATION GUARD (SHOWN HERE FOR o �}
MAPNEfII /IDNet ADDRESS DIP SWITCHES �} •SEPARATE SMARTSYNC CONTROL MODULES (SCMs) THAT PROVIDE REFERENCE ONLY, CAN BE l,!/
- MULTISTAGE ALARM OPERATION D PRINT R INFORMATION IN PLAIN ENGLISH LANGUAGE V O
SENSOR SEE BASE INSTALLATION INSTRUCTIONS USED ON OTHER MOUNTING °
-ABILITY TO DISPLAY AND PRINT DETAILED. CLASS B OR CLASS A OUTPUT FROM CONVENTIONAL. NAC INPUTS
574 -709. FOR SETTINGS — OPTIONS) t.� z Ii
• PHOTOELECTRIC SMOKE SENSOR 4098-9714:
SEVEN LEVELS OF SENSITIVITY FROM 0.2% TO 3.7% o SPECIFICATIONS.
• IONIZATION SMOKE SENSOR 4098 -9717: •HOUSING DIMENSIONS: 5 -1/8" H X 5" W X 2 -3/4° D (130mm X 127mm X 70mm) ° m i �1itiMitr>rr •
M 0.5% TO 1.7 %. ((� c �►
FOUR LEVELS OF SENSITIVITY FROM V ° •••�•
• HEAT SENSOR 4098 -9733: 1 .F • TEMPERATURE RANGE: 32'17 TO 1227F (0 TO 50'C)
TEMPERATURE
DETECTION IS SELECTABLE AT THE CONTROL PANEL FOR EITHER 5 4098 -9714 PHOTOELECTRIC SMOKE SENSOR • HUMIDITY RANGE: 10% TO 93% NON- CONDENSING AT 100'17 (38 C) a '
- RATE -OF -RISE
OR 20'17 PER MINUTE 4098 -9717 IONIZATION SMOKE SENSOR ° 0 0
o •TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER � �° a �' $y � 4
OR 2 TEMPERATURE SENSING IS INDEPENDENT OF RATE -OF -RISE AND PROGRAMMABLE TO OPERATE p ALTERNATE BACK BOXES w ':z
-FIXED
135 E OR 155'17 0 ° TERMINAL FOR IN /OUT WIRING. "
TO MONITOR 2. SING GANG
GANG /1.1 /2E°P DEEP BOX `
- TRUEALARM HEAT SENSORS CAN BE PROGRAMMED AS A UTILITY DEVICE 4098 -9733 HEAT SENSOR WIRING.
FOR TEMPERATURE EXTREMES IN THE RANGE FROM 32' F TO 120' F.
STANDARD ELECTRICAL BOX MOUNTING
UL STANDARD SPACING.
-60 A 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL 4" SQUARE BOX, 1 -1/2" DEEP
•
SPACING FOR 135' F
2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS, DO NOT LOOP U a 1a •• V.
-40 FT SPACING FOR 155 F WIRES UNDER TERMINALS.
• INTEGRAL RED LED FOR POWER -ON (PULSING), OR ALARM OR TROUBLE (STEADY ON}
SELECTION: 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER- LIMITED. �
• BASE MOUNTED ADDRESS FLUSH MOUNTING
4. SEE. INSTALLATION INSTRUCTIONS (579 -548) FOR ADDITIONAL INFORMATION. � �OQ1� SEMI -FLUSH MOUNTING
- ACCESSIBLE FROM FRONT (DIP SWITCH UNDER SENSOR)
ADDRESS REMAINS WITH ITS PROGRAMMED LOCATION (BOX TO BE FLUSH OR RECESSED 1/4" MAXIMUM) SURFACE MOUNTING U
• FOR USE WITH SIMPLEX 4010, 4100, 4020, AND 4120 SERIES CONTROL PANELS. STROBE' w
• MAXIMUM QUANTITY OF DEVICES: m • RATED VOLTAGE RANGE: UL LISTED: 16 VDC TO 33 VDC PER UL 1971 '" ° w
-127 FOR 4020, 4100, 4120 ULC LISTED: 20 VDC TO 30 VDC PER ULC S526 -M878
-250 FOR 4010, 4100 ..r
SURFACE MOUNT ADAPTER SKIRT
-FLASH RATE: 1 Hz U <
• MOUNTING: CEILING OR WALL 1 5 8° (41 mm) DEEP,
• SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. CONDUIT CUTOUTS ARE .PROVIDED TO ADDITIONAL NOTIFICATION a z
• COLOR : FROST WHITE
• BASE DIMENSIONS: 15/16" X 4 -7/8" ON ALL FOUR SIDES. APPLIANCE DEVICE OR RETURN H � Y
*CURRENT DRAWS REFLECT STROBE FLASHING
HOUSING LETTERING STROBE --� TO FACP FOR STYLE Z APPLICATION w
SPECIFICATIONS: — IF LAST DEVICE ON CIRCUIT IN A �► _
UL LISTED TEMPERATURE RANGE: 32'17 TO 100'17 MODEL NUMBER COLOR COLOR RATING 16 VDC 18 VDC 24 VDC
4906 -9101 RED WHITE 15cd 60 mA 53 mA 40 mA _— +� STYLE Y APPLICATION PLACE A E"'1 LL N
• • OPERATING TEMPERATURE RANGE. 37F To 120'17
30cd 94 mA 84 mA 63 mA N07 USED 10K 1/23 END -OF LINE RESISTOR z w
•HUMIDITY RANGE: 10% TO 95% RH 75cd 186 mA 165 mA 124 mA TERMINALS 3 & 4 ARE � W
GE: 0 -2000 FT MIN 110cd 252 mA 224 mA 168 mA z
• PHOTOELECTRIC SENSOR AIR VELOCITY RAN /fL �1Lk4L I I a g °
•IONIZATION SENSOR AIR VELOCITY RANGE: 0 -300 FT /MIN 4906 -9103 WHITE RED 15cd 60 mA 53 mA 40 mA I I I w
14 AWG wl mnr— nsm 30cd 94 mA 84 mA 63 mA
165 mA 124 mA _ J
R IN OUT WIRING, 18 TO R— 75cd 186 mA M
•WIRING CONNECTIONS: SCREW TERMINALS FOR / ri` I
•COMMUNICATIONS MAPNETII /IDNet: 1 ADDRESS PER BASE 110cd 252 mA 224 mA 168 mA z n
o CD ® (CJJ O '� a °
VOLTAGE (MAPNETII /IDNet): 24 -40VDC I d
CURRENT: 400uA TYPICAL ~ Q z
FROM A COMPATIBLE SIMPLEX ®®
DESCRIPTION:
IMPORTANT! SMARTSYNC NAC OR FROM E- m w o
C� SMARTSYNG CONTROL O I-
TRUFALARM SENSOR BASES CONTAIN INTEGRAL ADDRESSABLE ELECTRONICS WALL MOUNT INSTALLATION ® L_
OF THE DETACHABLE PHOTOELECTRIC, MODULE (SCM) 4905 -9938 ®� `• z wm ww
THAT CONSTANTLY MONITOR THE STATUS DIGITIZED AND
OR HEAT SENSORS. EACH SENSORS OUTPUT IS D HEIGHT REFERENCE OR SIMPLEX 4905 -9914 a a
IONIZATION. �� m Iii z .._
FIRE ALARM CONTROL PANEL EVERY FOUR SECONDS. rJ
TRANSMITTED 70 THE SYSTEM BOTTOM of LENS OR 9922 SYNC CUBE
SINCE TRUEALARM SENSORS USE THE SAME BASE, DIFFERENT SENSOR TYPES ELECTRICAL w
MEET SPECIFIC LOCATION REQUIREMENTS. THIS BOX oUruNE is EITHER EVEN WITH ¢ � � ~
CAN BE EASILY INTERCHANGED To I I I I I OR SLIGHTLY ABOVE
FEATURE ALLOWS INTENTIONAL SENSOR SUBSTITUTION DURING BUILDING CONSTRUCTION. I BOTTOM OF
RING THE SMOKE SENSORS, - COMPATIBLE BOXES w w w p
WHEN CONDITIONS ARE TEMPORARILY DUSTY, INSTEAD OF COVE w o w {
HEAT SENSORS MAY BE INSTALLED WITHOUT REPROGRAMMING THE CONTROL PANEL,
ALTHOUGH THE CONTROL PANEL WILL INDICATE AN INCORRECT SENSOR TYPE, THE HEAT
®o 0o p 0 o WQ 2
SENSOR WILL OPERATE AS A DEFAULT SENSITIVITY PROVIDING HEAT DETECTION FOR ® o
75
BUILDING PROTECTION AT THAT LOCATION. I I
+ NFPA 72 REQUIRES THAT � w �
WIRING. +
1. ALL WIRING TO COMPLY WITH LOCAL CODE. i---- TO ADDITIONAL MAPNETII /IDNet DEVICES Bo° THE ENTIRE LENS BE NOT INTENSITY SELECTION 15
FROM PREVIOUS SHIELD SHIELD SHIELD OR RETURN To FIRE ALARM CONTROL MIN. LESS THAN 80° AND NOT PLUG, ACCESSIBLE ONLY
►_-
2. CONDUCTORS MUST TEST FREE OF ALL GROUNDS. MAPNETII IDNet DEVICE "'— PANEL FOR A STYLE 6 APPLICATION GREATER THAN 96° ABOVE FROM REAR OF HOUSING;
3. MAINTAIN CORRECT POLARITY OR FIRE ALARM _ THE FINISHED FLOOR. ~
FACTORY SETTING IS 15cd z
4. MAPNETII /IDNet WIRING To BE X18 AWG TWISTED SHIELDED PAIR CONTROL PANEL S -- —
I USED TWIST SHIELD WIRES TOGETHER AND CAP WITH \ / STROBE INTENSITY o z
5. W SHIELD S �j
WIRE NUT. SHIELD SHOULD BE INSULATED FROM ELECTRICAL BOX. VIEWING SLOT - �
INSTRUCTIONS 574 -707 w J
6. REFER TO INSTALLATION ( )
� f/1 oz � �
R TO APPLICATION MANUAL (574 -709}
p v "' z
7. REFE •�' uzi = _ O
LL Lij
-+ + co u' z
a U)
Q °
w
fY co I
+� _ V
°~ a
z
a ff
o z 0
e6 w O
Q3 0 z ° a
0 2 0
'' z o
U1� -1 r- rn °aa o
a
DRAWN BY: DATE:
CCRJR 12/4!12
r_o.FMEDEPART1111 'VT DESIGNED BY: DATE
CCRJR 1214112
APPROVED BY: DATE:
4f
PROJECT NUMBER:
263. 4103041 967132602
SHEET TITLE/ PATH: i' 1
11Sgmiami1\drafUng\00- 20033100 -2003 , e
CAD Drawings\SOUTH MIAMI HOSPITAL
(MASTER SITE)\SMH CEN TRALZED
MONITORING 967132602
TYPICALS ET k t
NUMBER:
Typ
\ \50 WI \DRAR910 \00- 2003\FL. 06-203 CAD DWffi1 S\=M MIM HoSPf & (MASfFR WM\Sm cDMAtM MONDOM 967132602 \SMH MI(B•p"NUM V1Di9bb967432602M DATE 1°IATPED: DKamMr 12. 2012 DATE BAYED: Dwwbx 12. 2012