13-04-010w m r � m Cr_ z w ..ter 5 w mmn M W Cal w,- r n n_ Y wp ` Q w N i I1..1A Z .1�a =: rf 6 cj �,. cr M ~ (0 a R. ° 20 c t T Z LLI L D w a � raw r w O v Q z 1n � a ` L m J •(3) z w zw W ci yQ �4 z O CL z cc O L) U rn D w w z O z O 0 'ANON- ADDRESSABLE MULTI - CANDELA VISIBLE NOTIFICATION APPLIANCE 4098 -9792 STANDARD SENSOR BASE T rueAlert ° PRODUCT INFORMATION PRODUCT INFORMATION WHEN SURFACE MOUNTING USE 4" SQUARE x 1 -1/2" DEEP Box W (WALL MOUNT) RED SKIRT NO. 4905 -9937 OR co FEATURES: WHITE SKIRT NQ. 4905 -9940 FEATURES: • UL LISTED, FM APPROVED 4 X 1 1/2" DEEP OCTAGONAL • TRUEALARM ANALOG SENSING PROVIDES DIGITAL TRANSMISSION OF ANALOG UL LISTED TO STANDARD 1971 4905 -9931 ADAPTER PLATE Q 2975 -9145 BOX cc SENSOR VALUES VIA MAPNETII, OR IDNet TWO WIRE COMMUNICATIONS OR 0 m U • FIRE ALARM CONTROL PANEL PROVIDES: 4" SQUARE X 1 1/2" DEEP, WHICH REQUIRES • ADA COMPATIBLE ° � ° SELECTION FOR EACH SENSOR A 4098 -9832 ADAPTER PLATE (6 -3/8" X 1/4� SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: INDIVIDUAL SENSITIVITY SE BOX SUPPLIED BY CONTRACTOR � Lu -PEAK VALUE LOGGING ALLOWING ACCURATE ANALYSIS FOR SENSITIVITY SELECTION • SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE - AUTOMATIC ENVIRONMENTAL COMPENSATION 4905 -9(SH OPTIONAL WIRE o a - DISPLAY OF SENSITIVITY IN PERCENT PER FOOT O FOR CLASS 8 OR CLASS A OPERATION GUARD (SHOWN HERE FOR o �} MAPNEfII /IDNet ADDRESS DIP SWITCHES �} •SEPARATE SMARTSYNC CONTROL MODULES (SCMs) THAT PROVIDE REFERENCE ONLY, CAN BE l,!/ - MULTISTAGE ALARM OPERATION D PRINT R INFORMATION IN PLAIN ENGLISH LANGUAGE V O SENSOR SEE BASE INSTALLATION INSTRUCTIONS USED ON OTHER MOUNTING ° -ABILITY TO DISPLAY AND PRINT DETAILED. CLASS B OR CLASS A OUTPUT FROM CONVENTIONAL. NAC INPUTS 574 -709. FOR SETTINGS — OPTIONS) t.� z Ii • PHOTOELECTRIC SMOKE SENSOR 4098-9714: SEVEN LEVELS OF SENSITIVITY FROM 0.2% TO 3.7% o SPECIFICATIONS. • IONIZATION SMOKE SENSOR 4098 -9717: •HOUSING DIMENSIONS: 5 -1/8" H X 5" W X 2 -3/4° D (130mm X 127mm X 70mm) ° m i �1itiMitr>rr • M 0.5% TO 1.7 %. ((� c �► FOUR LEVELS OF SENSITIVITY FROM V ° •••�• • HEAT SENSOR 4098 -9733: 1 .F • TEMPERATURE RANGE: 32'17 TO 1227F (0 TO 50'C) TEMPERATURE DETECTION IS SELECTABLE AT THE CONTROL PANEL FOR EITHER 5 4098 -9714 PHOTOELECTRIC SMOKE SENSOR • HUMIDITY RANGE: 10% TO 93% NON- CONDENSING AT 100'17 (38 C) a ' - RATE -OF -RISE OR 20'17 PER MINUTE 4098 -9717 IONIZATION SMOKE SENSOR ° 0 0 o •TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER � �° a �' $y � 4 OR 2 TEMPERATURE SENSING IS INDEPENDENT OF RATE -OF -RISE AND PROGRAMMABLE TO OPERATE p ALTERNATE BACK BOXES w ':z -FIXED 135 E OR 155'17 0 ° TERMINAL FOR IN /OUT WIRING. " TO MONITOR 2. SING GANG GANG /1.1 /2E°P DEEP BOX ` - TRUEALARM HEAT SENSORS CAN BE PROGRAMMED AS A UTILITY DEVICE 4098 -9733 HEAT SENSOR WIRING. FOR TEMPERATURE EXTREMES IN THE RANGE FROM 32' F TO 120' F. STANDARD ELECTRICAL BOX MOUNTING UL STANDARD SPACING. -60 A 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL 4" SQUARE BOX, 1 -1/2" DEEP • SPACING FOR 135' F 2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS, DO NOT LOOP U a 1a •• V. -40 FT SPACING FOR 155 F WIRES UNDER TERMINALS. • INTEGRAL RED LED FOR POWER -ON (PULSING), OR ALARM OR TROUBLE (STEADY ON} SELECTION: 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER- LIMITED. � • BASE MOUNTED ADDRESS FLUSH MOUNTING 4. SEE. INSTALLATION INSTRUCTIONS (579 -548) FOR ADDITIONAL INFORMATION. � �OQ1� SEMI -FLUSH MOUNTING - ACCESSIBLE FROM FRONT (DIP SWITCH UNDER SENSOR) ADDRESS REMAINS WITH ITS PROGRAMMED LOCATION (BOX TO BE FLUSH OR RECESSED 1/4" MAXIMUM) SURFACE MOUNTING U • FOR USE WITH SIMPLEX 4010, 4100, 4020, AND 4120 SERIES CONTROL PANELS. STROBE' w • MAXIMUM QUANTITY OF DEVICES: m • RATED VOLTAGE RANGE: UL LISTED: 16 VDC TO 33 VDC PER UL 1971 '" ° w -127 FOR 4020, 4100, 4120 ULC LISTED: 20 VDC TO 30 VDC PER ULC S526 -M878 -250 FOR 4010, 4100 ..r SURFACE MOUNT ADAPTER SKIRT -FLASH RATE: 1 Hz U < • MOUNTING: CEILING OR WALL 1 5 8° (41 mm) DEEP, • SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. CONDUIT CUTOUTS ARE .PROVIDED TO ADDITIONAL NOTIFICATION a z • COLOR : FROST WHITE • BASE DIMENSIONS: 15/16" X 4 -7/8" ON ALL FOUR SIDES. APPLIANCE DEVICE OR RETURN H � Y *CURRENT DRAWS REFLECT STROBE FLASHING HOUSING LETTERING STROBE --� TO FACP FOR STYLE Z APPLICATION w SPECIFICATIONS: — IF LAST DEVICE ON CIRCUIT IN A �► _ UL LISTED TEMPERATURE RANGE: 32'17 TO 100'17 MODEL NUMBER COLOR COLOR RATING 16 VDC 18 VDC 24 VDC 4906 -9101 RED WHITE 15cd 60 mA 53 mA 40 mA _— +� STYLE Y APPLICATION PLACE A E"'1 LL N • • OPERATING TEMPERATURE RANGE. 37F To 120'17 30cd 94 mA 84 mA 63 mA N07 USED 10K 1/23 END -OF LINE RESISTOR z w •HUMIDITY RANGE: 10% TO 95% RH 75cd 186 mA 165 mA 124 mA TERMINALS 3 & 4 ARE � W GE: 0 -2000 FT MIN 110cd 252 mA 224 mA 168 mA z • PHOTOELECTRIC SENSOR AIR VELOCITY RAN /fL �1Lk4L I I a g ° •IONIZATION SENSOR AIR VELOCITY RANGE: 0 -300 FT /MIN 4906 -9103 WHITE RED 15cd 60 mA 53 mA 40 mA I I I w 14 AWG wl mnr— nsm 30cd 94 mA 84 mA 63 mA 165 mA 124 mA _ J R IN OUT WIRING, 18 TO R— 75cd 186 mA M •WIRING CONNECTIONS: SCREW TERMINALS FOR / ri` I •COMMUNICATIONS MAPNETII /IDNet: 1 ADDRESS PER BASE 110cd 252 mA 224 mA 168 mA z n o CD ® (CJJ O '� a ° VOLTAGE (MAPNETII /IDNet): 24 -40VDC I d CURRENT: 400uA TYPICAL ~ Q z FROM A COMPATIBLE SIMPLEX ®® DESCRIPTION: IMPORTANT! SMARTSYNC NAC OR FROM E- m w o C� SMARTSYNG CONTROL O I- TRUFALARM SENSOR BASES CONTAIN INTEGRAL ADDRESSABLE ELECTRONICS WALL MOUNT INSTALLATION ® L_ OF THE DETACHABLE PHOTOELECTRIC, MODULE (SCM) 4905 -9938 ®� `• z wm ww THAT CONSTANTLY MONITOR THE STATUS DIGITIZED AND OR HEAT SENSORS. EACH SENSORS OUTPUT IS D HEIGHT REFERENCE OR SIMPLEX 4905 -9914 a a IONIZATION. �� m Iii z .._ FIRE ALARM CONTROL PANEL EVERY FOUR SECONDS. rJ TRANSMITTED 70 THE SYSTEM BOTTOM of LENS OR 9922 SYNC CUBE SINCE TRUEALARM SENSORS USE THE SAME BASE, DIFFERENT SENSOR TYPES ELECTRICAL w MEET SPECIFIC LOCATION REQUIREMENTS. THIS BOX oUruNE is EITHER EVEN WITH ¢ � � ~ CAN BE EASILY INTERCHANGED To I I I I I OR SLIGHTLY ABOVE FEATURE ALLOWS INTENTIONAL SENSOR SUBSTITUTION DURING BUILDING CONSTRUCTION. I BOTTOM OF RING THE SMOKE SENSORS, - COMPATIBLE BOXES w w w p WHEN CONDITIONS ARE TEMPORARILY DUSTY, INSTEAD OF COVE w o w { HEAT SENSORS MAY BE INSTALLED WITHOUT REPROGRAMMING THE CONTROL PANEL, ALTHOUGH THE CONTROL PANEL WILL INDICATE AN INCORRECT SENSOR TYPE, THE HEAT ®o 0o p 0 o WQ 2 SENSOR WILL OPERATE AS A DEFAULT SENSITIVITY PROVIDING HEAT DETECTION FOR ® o 75 BUILDING PROTECTION AT THAT LOCATION. I I + NFPA 72 REQUIRES THAT � w � WIRING. + 1. ALL WIRING TO COMPLY WITH LOCAL CODE. i---- TO ADDITIONAL MAPNETII /IDNet DEVICES Bo° THE ENTIRE LENS BE NOT INTENSITY SELECTION 15 FROM PREVIOUS SHIELD SHIELD SHIELD OR RETURN To FIRE ALARM CONTROL MIN. LESS THAN 80° AND NOT PLUG, ACCESSIBLE ONLY ►_- 2. CONDUCTORS MUST TEST FREE OF ALL GROUNDS. MAPNETII IDNet DEVICE "'— PANEL FOR A STYLE 6 APPLICATION GREATER THAN 96° ABOVE FROM REAR OF HOUSING; 3. MAINTAIN CORRECT POLARITY OR FIRE ALARM _ THE FINISHED FLOOR. ~ FACTORY SETTING IS 15cd z 4. MAPNETII /IDNet WIRING To BE X18 AWG TWISTED SHIELDED PAIR CONTROL PANEL S -- — I USED TWIST SHIELD WIRES TOGETHER AND CAP WITH \ / STROBE INTENSITY o z 5. W SHIELD S �j WIRE NUT. SHIELD SHOULD BE INSULATED FROM ELECTRICAL BOX. VIEWING SLOT - � INSTRUCTIONS 574 -707 w J 6. REFER TO INSTALLATION ( ) � f/1 oz � � R TO APPLICATION MANUAL (574 -709} p v "' z 7. REFE •�' uzi = _ O LL Lij -+ + co u' z a U) Q ° w fY co I +� _ V °~ a z a ff o z 0 e6 w O Q3 0 z ° a 0 2 0 '' z o U1� -1 r- rn °aa o a DRAWN BY: DATE: CCRJR 12/4!12 r_o.FMEDEPART1111 'VT DESIGNED BY: DATE CCRJR 1214112 APPROVED BY: DATE: 4f PROJECT NUMBER: 263. 4103041 967132602 SHEET TITLE/ PATH: i' 1 11Sgmiami1\drafUng\00- 20033100 -2003 , e CAD Drawings\SOUTH MIAMI HOSPITAL (MASTER SITE)\SMH CEN TRALZED MONITORING 967132602 TYPICALS ET k t NUMBER: Typ \ \50 WI \DRAR910 \00- 2003\FL. 06-203 CAD DWffi1 S\=M MIM HoSPf & (MASfFR WM\Sm cDMAtM MONDOM 967132602 \SMH MI(B•p"NUM V1Di9bb967432602M DATE 1°IATPED: DKamMr 12. 2012 DATE BAYED: Dwwbx 12. 2012