Loading...
13-04-007MAXIMUM 51S89 EXIST] TO RISER -5 iMP " IMN 1MN_ 1MN SYMBOL LEGEND DEVICES SYMBOL SIMPLEX MODEL i DESCRIPTII FACP 4100 -9111 NETWORK FIRE ALARM PAN: .M" VOIC_ ® 4009 -9201 MAC EXTENDER, 120VAC. IDNET. FAT( FIRE ALARM TERMINAL CABINET cn Q FURNISHED BY ELECTRICAL CONTRACTOR " Q 2MP PULL STATION ADDRESSABLE 1 2099-9813 PULL STATION FLUSH TRIM ® 4098 -9792 SSD SENSOR BASE m Ir 4098.9714 SSD PHOTO SENSOR Zt 4090.9001 INDIVIDUAL ADDRESS MODULE CONNECT TO NPO CONTACTS ONLY ® 2190.9161 NOTIFICATION APPLIANCE ZAM �H CC-623 HEAT DETECTOR 135' FIXED Q ELEVATOR SHUNT TRIP OPERATION Q 4098 -9792 SSD SENSOR BASE - 2MN 4098- 9733 SSD HEAT SENSOR �ii�(D -U-) 4098 -9758 SSD DUCTSENSOR HOUSING �,- 2098 -9797 SAMPLING TUBE 49' O 2098 -9808 REMOTE TEST STATION RED LED KEY SWITCH all 4098 -9843 RELAY FORM C SPOT PAMSD ® 2081 . RELAY SPOT WILED MR -8011T - ® 4905 -9938 SMARTSYNG CONTROL MODULE °t 4902 -9703 SPEAKER WALL MOUNT GS .5w 4902 -9721 SPEAKER 25170 VRMS WHITE ROUND CEILING MOUNT . 15CD EK tOB SPEAKERISTROBE 1 SCO SYNC WALL MOUNT 0.090 AMPS 110CD MI _ SPEAKERISTROBE 1 I OCD SYNC WALL MOUNT 0275 AMPS 75CD o 49DO-9151. SPEAKERISTROBE 75CD SYNC WALL MOUNT 0.186 AMPS 75CD EN WP ET70WP- 2475W -FR WEATHERPROOF SPEAKERISTROBE 75CD SYNC WALL 0.102AMPS 15M [D 4904 -9176 STROBE 15CD SYNC WALL MOUNT 0.082 AMPS I IOCD LO 4904 -9175 STROBE 110CD SYNC WALL MOUNT 0275 AMPS 75CD ❑L 4906-9101 STROBE 75CD SYNC WALL MOUNT 0.188 AMPS FS FLOW DETECTOR SWITCH FURNISHED BY DIVISION 15 TS TAMPER (GATE VALVE) SWTTCH 7 FURNISHED BY DIVISION 15 -�Lr• - END OF LINE RESISTOR - F- Z O F 2084 -9001 FIREMANS PHONE JACK - ® EL-1-SS ELEVATOR WARNING SIGN ® 2088.9608 DOOR HOLDER 1, � F- CONNECTION TO AN APPROVED, DEDICATED EARTHGROUND, NFPA 70. COMPLY WITH NEC. _ 120VAC SOURCE DEDICATED BREAKER COMPLY WITH NFPA 70. 4F OZ U NEW E EXISTING - R O RELOCATED - w WATTS LL D W V3 5:M7.87 5:M7 -88 5:M7 -89 tY m L) U U W N 2C 1C 2C 1C 2C 1C O O z p y GO cQ c�vt4 4lftffiff� i co _m' R R ,/Nr R � tu h e W F- u) w r U 5:M7 -87A &M7-87B Z &W-88a 5:M7 -88B g o 5:M7 -89A 5:M7 -89B Q Q Z 0= N W W FF-- z LL N O J J W 0 z W .4 J 0X h J Z m OU00 Q v W _ H ~ Y U) N z pq ZW Lf? U LIE'+ m 5:M7 -74 5:M7 -75 5:M7 -76 5:M7 -77 5:M7 -78 5:M7 -79 5:M7 -80 5:M7 -81 5:M7 -82 5 :M7-83 5:M7 -84 J w0 Q n p �( v C ZZO 00 z �( r4 H O w -i D- ' J Z FJQ_ w SD S SD SD SD SD S SO SD SD S -+� a _ v, D- 0 Zp 5 W U) o O Z 0 r-1 0 O zO O� Z �' e�j e-1 0 M r• 04 V) rxq Xin 5:5109 -4 5:$709 -3 5:$109 -2 5:$709 -1 DATE: CCRJR 12/4/12 DESIGNED BY: DATE: CCRJR 1214/12 APPROVED BY: DATE: PROJECT NUMBER: 263- 410304 / 967132602 SHEET TITLE/ PATH: Wgmiami 1kUaf6ngW0 -2003W 100 -2003 CAD Drawings\SOUTH MIAMI HOSPITAL (MASTER SITE)1SMH CENTRALIZED MONITORING 967132602 SHEET NUMBER: RISER -4 SIZE: D (247(387 7F 5:M7 -60 5:MT -61 5:M7 -62 5:M7 -63 5:MT -64 5:M7 -65 5:M7 -66 5:W-67 5:MT -68 5:M7 -69 5:M7 -70 5:M7 -71 5:M7 -72 5:MT -73 FJ I'll FJ FJ Z1 Z1 F s so so sD so so s0 F SD S SD 1A is FS TS MAXIMUM 2,000 AMPS 51$13 EXISTING 0.636 AMPS 75CD 75CD 75CD 15CD 5:M7 -60A 5:W-61A - 5:S26 -11 15CD 5:S26 -10 15CD 5:S26 -9 15CD 5:S26 8 1B 5:M7-44 5:M7 -45 5:M7 -46 5:M747 5:M7.49 5:W-50 5:W-51 5:M7 -52 5:M7 -53 5:M7 -54 5:M7 -55 5:W-58 5:M7 -59 MN 1p -7 —5:-w48 - :0-1-1111''''i L S L S L S F SD SD SD SD SD SD F SD S SD S SD SD 5:Si3 -7 5:S13-6 5:Si3-5 5:Si3 -4 5:S13 -3 5:S13 -2 &S13 -1 MAXIMU 2.000 AMPS 51S88 EXI ING 0.300 AMPS MAXIMUM 2.000 AMPS 15CD 18 51$14 EXISTING 0,660 AMPS 15CD 15CD 15CD 75CD 15CD 15CD 15CD tD 75CD 2g 5:S26 -7 5:S26.6 5:S26 -5 5:S26.4 5:S26 -3 5:S26 -2 5:S26 -1 DOOR DAMPERS POWERIDAMPER 75CD 2D ig 5:M3 -123 5:M3 -126 5:M7 -127 2Q S F S S 5 S S S S Z2 2 Z1 5:589 3 5:$1373 S:S710 1 5:S14 -7 5:S14 -6 5:St4-5 &S14-4 &S14 -3 &S14 -2 5:S14 -1 1C 1C 1C &1363 1B "5:Slli-1 S:S5:$7363 R R R 1D 5:S 5:M3 -123A 5 :M3126A 5: - 27A 000 AMPS 2F MAXIMUM 2.000 AMPS . 0.300 AMPS 51S76 EX13TING 1.215 AMPS 75CD 1131 15CD 110CD i B 5'582 -1 i ISQD 15cp 5:M345 5:M346 5:M3-47 5:M3-48 5:M3-19 5:M350 5:M3-51 5:M352 5:M353 5:M3-54 5:M3-55 5:M3-56 5:M3S7 5:M3-58 MN L L L L L S L L L L L so s0 F so so s0 s s s0 sD s so F 1B s 1D 5:S76 -12 5:S76.10 5:S76 -9 5 :S76 -8 5:S76 -7 5:S76 -6 5:576 -5 5:S764 5:S76 -3 5:S76 -2 5:576 -1 MAXIMUM 2.000 AMPS 51S77 EXISTING 1,390 AMPS 110CD 15CD 75CD 110CD 15CD 15CD 15CD 15CD 15CD 15CD 15CD 113 5:S83 -11 5:S83 -10 5:S83 -9 5:S83 -8 5:S83 -7 5:S83 -6 5:S83 -5 5:S834 5:S83 -3 5:S83 -2 5:S83 -1 5:M3 -31 5:M3 -32 5:M3 -33 5:M334 5:M3 -35 5:M3 -36 5:M3 -37 5:M3-38 5:M3-39 5:M340 5:M3-41 5:M3.42 5:M3.43 5:M3-44 I NI S S S S S S S S S S S SD S SD S SD F SD S SD S S S SD SD 5:S77 -11 5:S77 -10 5:S77 -9 5:S77 -8 5:S77 -7 5:S77 -6 5:S77 -5 5:S774 5:S77 -3 5:S77 -2 5:S77 -1 FATC SIXTH FLOOR 4MP 4MN 14B 10 5F DOOR DOOR DAMPERS DAMPERS POWER/DAMPER DAMPERS 5:M7 -106 5:M7 -107 5:M7 -111 5:W-1 12 5:M7 -125 5:M7 -127 Z2 Z2 Z2 Z2 Z1 Z2 1C 1C 7C 1C iC 1C DH R R R R R 5:M7 -106A 5:M7 -107A 5:M7 -111A 5:M7 -112A 5: -125A 5:M7 -127A &S106 -6 5:S106 -5 &S106.4 5:S106 -3 5:S106 -2 5:S106 -1 IF 5:M7 -97 5:M7 -98 5:M7 -99 5:M7 -100 5:M7 -101 5:M7 -102 5:M7 -103 5:M7 -104 5:M7 -105 5:M7 -108 5:M7 -109 FJ FJ FJ FJ FJ FJ S sD s s sD sD s s s so so MAXIMUM 2,000 AMPS 51S75 EXISTING 1.522 AMPS 15CD 15CD 15CD 15CD 15CD 0 5:S81 -5 15CD 15CD &S81-4 S:S81 -3 5:S81 -2 5:S81 -1 1B 1B 5:M734 5:M735 5:M7-36 5:M7 -37 5:M7 -38 5:M739 5TM740 5:M7 -90 5:M7 -91 5:M7 -92 5:M7 -93 5:M7 -94 5:M7_95 5:M7 -96 tQ L L L S L -VI L S S S S L L L s F s0 s S s0 s0 so so s s So s so 5:S75 -13 5:S75 -12 5:S75 -11 :S75 -10 5:S75 -9 5:S75 -8 5:S75 -7 5:S753 5:S75-5 5:S75 -4 5:S753 5:S75 -2 5:S75 -1 MAXIMUM 2.000 AMPS 51S68 EXISTING 1.451 AMPS 15CD 75CD 15CD 15CD 15CD 15CD 15CD 15CD 15CD 5:S74 -10 5:$74 -9 5:S74 -7 5:S74-6 5:S74 -5 5:S74 -4 5:S74 -3 5:S74 -2 5:S74 -1 iB 5:MT -17 5:M7 -21 5:M7 -22 5:M7 -23 5:M7 -24 5:M7 -25 5:M7 -26 5:M7 -27 5:M7 -28 5:M7 -29 5:M7 -30 5:M7 -31 5:M7 -32 5:M7 -33 7D S S S S S S S S SD SD S Zi Z1 F SD S SD S S S SD S :S68 -10 5:S68 -9 5:S68 -7 5:S68 -6 5:S68 -5 5:568 -4 5:S68 -3 5f668-2 5:S68 -1 to 10 1A FS TS ml MN 5:M7 -23A 5:M7 -24A 16 1D 1D 1D 1D 5:M7 -1 5 :M7 -2 5:M7 -5 5:M7 -6 5:M7 -7 &W-8 5:M7 -9 5:M7 -10 5:M7 -11 5:M7 -12 5:MT -13 . 5:M7 -14 5:M7 -14 5:M7 -16 MAXIMUM 2.000 AMPS 51N1/2 EXISTING 1.488 AMPS 1B 18 1B iB iB 1B 18 B 2:M -25 2:M7 -25A 75CD 75CD F s s so s0 so so s s so F s so s 75CD 75CD 75CD 75CD 75CD 75CD Z7 TS FJ FJ S S 5:$107 -1 Ni -2-8 N1 -2 -7 N7 -2.6 Nt -2 -5 NI-24 Ni-2-3 -2 Nt -2 -t iB &S108 -1 5:S68 -11 5:S74 -8iB 1D 3F iB 1D 75CD iB 75CD 1B 7B 75CD 75CD DAMPERS DAMPERS POWERMAMPER 2 :M -26 2:M1-26A 5F MAXIMUM 2.000 AMPS 5:M3 -29 5:M3 -30 5:M3 -59 5:M3.122 5:M3 -124 5:M3 -125 Zt FS 51N1/1 EXISTING 0.744 AMPS N1 -7 4 NI-1-3 N1 -1-2 NI-1-1 s F Z1 Z2 Z2 iA 1C 1G Lic R R TS 5:M3 -122A 5:M3 -124A 5:M3 -125A MN iB 5:5116 1B -5 S:Sit -5 iB 5:$114 1B 1B 16 5:M3 -59A 1D MAXIMUM 2.000 AMPS 5:S25-5 10 5:SII 1D 5::S25-3 1) 5:$113 1D 5: 1D 51S11 EXISTING 0.570 AMPS 5: 5:M315 5:M3 16 5:M3 17 5:M3 18 5:M3 19 5:M3 20 5:M3 21 5:M3 22 5:M3 23 5:M3 24 5:M3 25 5:M3 26 5:M3 27 5:M3 28 15CD i5CD 75CD 75CD S SD SD SD S SD F SD S S S S S SD SD 5:S123 1B 5:Si2 -7 1B 1D 1D 1B ID 5:SI2 -5 iB 5:S12-4 1Q 16 1B iB 5:S12 -2 5 -S12 -1 1D 1D 1D 16 iD MAXIMUM 2.000 AMPS 5:S25 -11 5:S25 -10 &S12 -6 5:S25 -9 5:S25 -8 5:St2 -3 5:$25 7 5:S25 -6 51$12 EXISTING 0.726 AMPS 5:M3 -1 5:43 -2 5:M3 -3 5 :M3-4 5:M3 -5 5:M3 -6 5:M3 -7 5:M38 5:M3 -9 5:13 -10 5:M3 -11 5:M3 -12 5:M3 -13 5:M3 -14 75CD 75CD 75CD 15CD 75CD 15CQ 15CD 75CD S S L S S L S S SD SD s S SD F SD SD sD s s s sD s FATC FIFTH FLOOR iMP " IMN 1MN_ 1MN SYMBOL LEGEND DEVICES SYMBOL SIMPLEX MODEL i DESCRIPTII FACP 4100 -9111 NETWORK FIRE ALARM PAN: .M" VOIC_ ® 4009 -9201 MAC EXTENDER, 120VAC. IDNET. FAT( FIRE ALARM TERMINAL CABINET cn Q FURNISHED BY ELECTRICAL CONTRACTOR " Q 4099 -9001 PULL STATION ADDRESSABLE 1 2099-9813 PULL STATION FLUSH TRIM ® 4098 -9792 SSD SENSOR BASE m Ir 4098.9714 SSD PHOTO SENSOR Zt 4090.9001 INDIVIDUAL ADDRESS MODULE CONNECT TO NPO CONTACTS ONLY ® 2190.9161 NOTIFICATION APPLIANCE ZAM �H CC-623 HEAT DETECTOR 135' FIXED Q ELEVATOR SHUNT TRIP OPERATION Q 4098 -9792 SSD SENSOR BASE - 4098- 9733 SSD HEAT SENSOR �ii�(D -U-) 4098 -9758 SSD DUCTSENSOR HOUSING �,- 2098 -9797 SAMPLING TUBE 49' O 2098 -9808 REMOTE TEST STATION RED LED KEY SWITCH all 4098 -9843 RELAY FORM C SPOT PAMSD ® 2081 . RELAY SPOT WILED MR -8011T - ® 4905 -9938 SMARTSYNG CONTROL MODULE °t 4902 -9703 SPEAKER WALL MOUNT GS .5w 4902 -9721 SPEAKER 25170 VRMS WHITE ROUND CEILING MOUNT . 15CD EK 4903 -9178 SPEAKERISTROBE 1 SCO SYNC WALL MOUNT 0.090 AMPS 110CD MI 4903 -9349 SPEAKERISTROBE 1 I OCD SYNC WALL MOUNT 0275 AMPS 75CD o 49DO-9151. SPEAKERISTROBE 75CD SYNC WALL MOUNT 0.186 AMPS 75CD EN WP ET70WP- 2475W -FR WEATHERPROOF SPEAKERISTROBE 75CD SYNC WALL 0.102AMPS 15M [D 4904 -9176 STROBE 15CD SYNC WALL MOUNT 0.082 AMPS I IOCD LO 4904 -9175 STROBE 110CD SYNC WALL MOUNT 0275 AMPS 75CD ❑L 4906-9101 STROBE 75CD SYNC WALL MOUNT 0.188 AMPS FS FLOW DETECTOR SWITCH FURNISHED BY DIVISION 15 TS TAMPER (GATE VALVE) SWTTCH z O FURNISHED BY DIVISION 15 -�Lr• - END OF LINE RESISTOR - F- Z O F 2084 -9001 FIREMANS PHONE JACK - ® EL-1-SS ELEVATOR WARNING SIGN ® 2088.9608 DOOR HOLDER 1, � F- CONNECTION TO AN APPROVED, DEDICATED EARTHGROUND, NFPA 70. COMPLY WITH NEC. _ 120VAC SOURCE DEDICATED BREAKER COMPLY WITH NFPA 70. N OZ U NEW E EXISTING - R O RELOCATED - w WATTS 1MN iMP iMO WIRE LEGEND 1MN A= INITIATING DEVICE CIRCUIT - IDC 2 #14 AWG THHN B = NOTIFICATION APPLIANCE CIRCUIT - NACMSUAL 2 #12 AWG THHN C = AUXILIARY CONTROL CIRCUIT - ACC 2 #14 AWG THHN D = VOICE COMMUNICATION CIRCUIT- VCC 1MN 18/2 TWISTED SHIELDED PAIR -NPLF F = FIRE FIGHTERS TELEPHONE CIRCUIT - FTC 18/2 TWISTED SHIELDED PAIR - NPLF MN= MULTI- ADDRESSABLE PERIPHERAL NETWORK - MAPNET 18/2 TWISTED /SHIELDED PAIR - NPLF MP= MAPNET POWER CIRCUIT -APC 2 #14 AWG THHN IMP 1MN iMN iMO iMN iMN iMP 1MN 1MN 1MN a�iA� LU U L cn Q zQ C6 1 W L4 m Ir u- < cc O `. Q a u-) F- Lo z 1 n' �ii�(D -U-) 00 Lo E �,- CO 4 0 O 'rQ\ 0�2O Lr) — cr- W D- M °t U LU z `Q3 L) Q z V) 0- J 4..j J W W > _ Z W 4 W 17' v N J (rip < V z O F- Z O CL U LU V W O � F- O OZ U D O LL D W V3 to tY m L) U U W N Q O O z p y GO cQ c�vt4 4lftffiff� i co � � tu h e W F- u) w r U C3 Z g o V Q Q Z 0= N W W FF-- z LL N O J J W 0 z W .4 J 0X h J Z m OU00 Q v W _ H ~ Y U) N z pq ZW Lf? U LIE'+ m m cc CL w w Q U wO _ -, LL 0 P-4 F- IL o J w0 Q n p �( v C ZZO 00 z �( r4 H O w -i D- ' J Z FJQ_ w o F- U Z Z O 4-' Z W 0 z 0 d' �-1 c Q 4 vWi Q 0 LU O Q w -+� a _ v, D- 0 Zp 5 W U) o O Z 0 r-1 0 O zO O� Z �' e�j e-1 0 M r• 04 V) rxq Xin 044 o DRAWN BY: DATE: CCRJR 12/4/12 DESIGNED BY: DATE: CCRJR 1214/12 APPROVED BY: DATE: PROJECT NUMBER: 263- 410304 / 967132602 SHEET TITLE/ PATH: Wgmiami 1kUaf6ngW0 -2003W 100 -2003 CAD Drawings\SOUTH MIAMI HOSPITAL (MASTER SITE)1SMH CENTRALIZED MONITORING 967132602 SHEET NUMBER: RISER -4 SIZE: D (247(387