Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-984-047
E 70 cr CL: C rN CD cy r O. tV LO N oc , 0 2 ABC ABOVE COUNTER ACLG ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE BKR BREAKER CB CIRCUIT BREAKER CKT CIRCUIT CL CENTER LINE CLG CEILING MOUNTED DEVICE DISC DISCONNECT DIV DIVISION ECB ENCLOSED CIRCUIT BREAKER EX EXISTING EXR EXISTING, RELOCATED F FRAME F/A FIRE ALARM FCU FAN COIL UNIT FLA FULL LOAD AMPS FU FUSE G GROUND HP HORSE POWER K KILO 3 MCB MAIN CIRCUIT BREAKER MLO MAIN LUGS ONLY NCT NURSE CALL TERMINAL CABINET NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NL NIGHT LIGHT OC OVER CURRENT OCP OVER CURRENT PROTECTION P POLE PH PHASE SMH SPECIAL MOUNTING HEIGHT TV TELEVISION TYP TYPICAL UH UNIT HEATER UG UNDER GROUND ELECTRICAL UON UNLESS OTHERWISE NOTED LION UNINTERRUPTIBLE POWER SUPPLY V VOLT(S) VA VOLT - AMPS) W WATT(S), WIRE, WALL TELEPHONE OUTLET WP WEATHERPROOF DEVICE, NEMA 3R XFMR TRANSFORMER STRUCTURE ABOVE ATTACH CADDY ANGLE SYSTEMS RESPONSOLTY SCHEDULE .. BRACKETS (TYPICAL) MOUNTING MINIMUM THREE TWISTS ATTACH CADDY ANGLE DESCRIPTION BRACKET WITH LIGHTING EET- SEAL PENETRATIONS SO AS *12 GAUGE GALVANIZED METAL SCRIEWSSH TO MAINTAIN RATING OF WIRE HANGER (TYPICAL) WALL FOR FIRE PROOFING. MINIMUM 157 OFF VERTICAL BOTH DIRECTIONS FIRE RATED FIXTURE (TYPE DETERMINES MOUNTING) WALL TELEPHONE CONDUIT TYPICAL LIGHTING FIXTURE / FIXTURE SUPPRORT NOTES: OWNER I. ATTACH ALL LIGHT FIXTURES TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. OWNER 2. ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING LESS THAN 56 NORMAL BRANCH SURFACE OR RECESSED FIXTURE POUNDS SHALL BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY SEAL AT BOTH ENDS SO AS DUTY GRID SYSTEM AND THEY MUST HAVE A MINIMUM OF TWO *12 GAUGE TO MAINTAIN RATING OF SLACK SAFETY WIRES ATTACHED AT DIAGONAL CORNERS AND ANCHORED TO SLEEVE THE STRUCTURE ABOVE. WALL FOR FIRE PROOFING. 3. ALL FIXTURES SUPPORTED ON INTERMEDIATE DUTY GRID SYSTEMS MUST CONTRACTOR BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR TAUT *12 GAUGE WIRES ATTACHED TO THE STRUCTURE ABOVE. CONTRACTOR 4. ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING MORE THAN 56 CRITICAL OR EQUIPMENT BRANCH SURFACE OR RECESSED POUNDS MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR CONTRACTOR *12 GAUGE TAUT WIRES ATTACHED TO THE STRUCTURE ABOVE REGARDLESS OF THE TYPE OF CEILING GRID SYSTEM USED. SWITCHES 5. THE FOUR TAUT *12 GAUGE WIRES INCLUDING THEIR ATTACHMENT TO THE SINGLE POLE SWITCH - IVORY TOGGLE STRUCTURE ABOVE MUST BE CAPABLE OF SUPPORTING FOUR TIMES THE $ WEIGHT OF THE UNIT. T -10" AFF TO CL FIXTURE SUPPORT DETAIL DIMMER SWITCH - IVORY RATED WALL PENETRATIONS $D 4 5 LEGEND SYSTEMS RESPONSOLTY SCHEDULE .. SYSTEM MOUNTING SYMBOL DESCRIPTION HEIGHT LIGHTING SEVENTH FLOOR PLAN - NEW CONSTRUCTION - LIGHTING ® SEVENTH FLOOR PLAN - NEW CONSTRUCTION - POWER AND SYSTEM NORMAL BRANCH SURFACE OR RECESSED FLUORESCENT INSTALLED BY: CONDUIT: FURNISHED BY: INSTALLED BY: FIXTURE (TYPE DETERMINES MOUNTING) : NOTES.,* TELEPHONE ® OWNER CRITICAL OR EQUIPMENT BRANCH SURFACE OR RECESSED OWNER OWNER OWNER FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) OWNER O NORMAL BRANCH SURFACE OR RECESSED FIXTURE OWNER OWNER (TYPE DETERMINES MOUNTING) FIRE ALARM ® ® CRITICAL OR EQUIPMENT BRANCH SURFACE OR RECESSED FIXTURE CONTRACTOR CONTRACTOR IN CONTRACT DOCUMENTS (TYPE DETERMINES MOUNTING) CONTRACTOR CONTRACTOR CRITICAL OR EQUIPMENT BRANCH SURFACE OR RECESSED CONTRACTOR CONTRACTOR FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) DOOR ACCESS SWITCHES S SINGLE POLE SWITCH - IVORY TOGGLE 3' -10" AFF TO CL $ SINGLE POLE SWITCH - RED TOGGLE T -10" AFF TO CL SD DIMMER SWITCH - IVORY 3' -10" AFF TO CL $D DIMMER SWITCH - IVORY AFF TO CL SM DUAL TECHNOLOGY OCCUPANCY SENSOR SWITCH - IVORY 3' -10" SENSOR SWITCH *WSD- PDT -SA OR APPROVED EQUAL AFF TO CL DUAL TECHNOLOGY OCCUPANCY SENSOR SWITCH - RED 3' -10" M SENSOR SWITCH *WSD- PDT -SA OR APPROVED EQUAL AFF TO CL ST MOTOR RATED SWITCH WITH THERMAL OVERLOAD. MOUNT ADJACENT TO MOTOR LOAD. os LOW VOLTAGE OCCUPANCY SENSOR CEILING SENSOR SWITCH *CM -PDT -9 OR APPROVED EQUAL POWER - RECEPTACLES ALL RECEPTACLES AND DEVICE PLATES SHALL BE IVORY, EXCEPT WHERE INDICATED WITH I SUBSCRIPT "C" IN WHICH A RED DEVICE AND PLATE SHALL BE PROVIDED. 120V. DUPLEX RECEPTACLE 1._6., AFF TO CL. 120V. DUPLEX RECEPTACLE - SPECIAL MOUNTING HEIGHT AS NOTED OR SEE SPECS 120V.QUADPLEX RECEPTACLE AFF TO TO CL. 120V. QUADPLEX RECEPTACLE - SPECIAL MOUNTING HEIGHT AS NOTED OR SEE SPECS TELEPHONE /DATA COMBINATION DATA /TELEPHONE OUTLET WITH PLATE AFF TO CL FIRE ALARM EE> FIRE ALARM VISUAL STATION - LIGHT ONLY 80" TO BOTTOM OF LENSE FIRE ALARM SMOKE DETECTOR CEILING FATC FIRE ALARM TERMINAL CABINET FACE FIRE ALARM CONTROL PANEL MISCELLANEOUS q= NON - FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) MOTOR CONNECTION e! PANELBOARD - SURFACE MOUNTED CARD READER 3' -10" AFF TO CL RACEWAY CONDUIT A BRANCH CIRCUIT WIRING CONCEALED EXPOSED RACEWAY BRANCH CIRCUIT RACEWAY CONCEALED IN OR BELOW FLOOR SLAB OR BELOW GRADE FEEDER RACEWAY CONCEALED IN OR BELOW FLOOR SLAB OR BELOW GRADE �+ RACEWAY TURNING UP AS VIEWED FROM THE LOAD �---• RACEWAY TURNING DOWN AS VIEWED FROM THE LOAD RACEWAY VERTICAL RISER WITH HORIZONTAL CONTINUATION AT TWO LEVELS SHOWN CAPPED RACEWAY HOMERUN TO PANELBOARD - NUMBER OF ARROWHEADS INDICATES THE NUMBER OF *12 AWG PHASE CONDUCTORS, AS WELL AS THE NUMBER OF *12 NEUTRAL CONDUCTORS. FOR MINIMUM CONDUIT REFER TO 1 SPECIFICATION. NOTES: 1. MULTI -WIRE BRANCH CIRCUITS SHALL NOT BE UTILIZED. X12 AWG NEUTRAL CONDUCTOR SHALL NOT BE SHARED BETWEEN PHASES. PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT. 2. *12 AWG GREEN GROUND CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. 3. HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE (3) PHASE CONDUCTORS & (3) NEUTRAL CONDUCTS (ONE PER PHASE) PLUS GROUND CONDUCTORS IN EACH CONDUIT. INFECTION CONTROL MEASURES I. CONTRACTOR SHALL OBTAIN FROM THE OWNER A COPY OF THE INFECTION CONTROL t SKI ASSESSMENT (ICRA) PREPARED FOR THIS PROJECT. CONTRACTOR SHALL REVIEW THE REQUIREMENTS IN THE REPORT AND PERFORM ALL WORK IN ACCORDANCE WITH THOSE REQUIREMENTS. CONTRACTOR SHALL STRICTLY ADHERE TO THE LIMITS OF THE 'CONSTRUCTION AREA, AND WHERE PHASING APPLIES SHALL ADHERE TO THE PHASING PLAN. ANY WORK OUTSIDE THE CONSTRUCTION AREA SHALL BE COORDINATED WITH: THE OWNER AND PERFORMED IN ACCORDANCE WITH THE ICRA REPORT, UNDER THE !SUPERVISION OF THE OWNER'S REPRESENTATIVE OR OTHER DESIGNATED ICRA COMMITTEE OFFICER. l 2. TO THE EXTENT THAT IT IS REQUIRED BY THE ICRA, THE CONTRACTOR SHALL ENDEAVOR TO MAINTAIN EXISTING LEVELS OF INDOOR AIR QUALITY IN AREAS SURROUNDING AND ADJACENT TO THE CONSTRUCTION WORK ZONE, AND ELSEWHERE IN THE FACILITY. IT SHOULD BE ANTICIPATED THAT THE ICRA REPORT WILL REQUIRE MEASURES TO THIS EFFECT INCLUDING ERECTION OF CONSTRUCTION ZONE BARRIERS AND i PROVISION OF NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE RELATIVE TO OTHER AREAS OF THE FACILITY. ••rr r•• .. • 7 • • 6 . . i • • • Y • SYSTEMS RESPONSOLTY SCHEDULE .. SYSTEM INTERIOR CABLE INTERIOR CABLE EXTENT OF EQUIPMENT EQUIPMENT SEVENTH FLOOR PLAN - NEW CONSTRUCTION - LIGHTING • SEVENTH FLOOR PLAN - NEW CONSTRUCTION - POWER AND SYSTEM FURNISHED BY: INSTALLED BY: CONDUIT: FURNISHED BY: INSTALLED BY: SPECIFIER: : NOTES.,* TELEPHONE OWNER OWNER O1 OWNER OWNER OWNER COMPUTER OWNER OWNER O OWNER OWNER OWNER FIRE ALARM CONTRACTOR CONTRACTOR FULL RACEWAY SYSTEM CONTRACTOR CONTRACTOR IN CONTRACT DOCUMENTS SECURITY/ CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR VENDOR DOOR ACCESS O NOTES: 1, STUB INTO ACCESSIBLE CEILING SPACE BY CONTRACTOR. 2. COORDINATE WITH HOSPITAL'S ACCESS CONTROL VENDOR INGERSOL RAND (PHIL CERBER a 305 -796 -0418) FIRE Al APKA REFER TO FLOOR PLANS FOR QUANTITY OF DEVICES DIAGRAM FIRE ALARM SYSTEM NOTES: A. CONTRACTOR SHALL REFER TO SPECIFICATIONS. S. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING VENDOR SHOP DRAWINGS INDICATING ALL MODEL NUMBERS, WIRING REOUI REMENTS AND BATTERY CALCULATIONS. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY FLORIDA REGISTERED ENGINEER. C. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL SYSTEMS EQUIPMENT AND CABLE AND ALL INSTALLATIONS. D. REFER TO FIRE ALARM MANUFACTURERS' RECOMMENDATIONS FOR CONDUIT AND CONDUCTOR SIZE AND TYPES. REFER TO SPECIFICATIONS. E. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HARDWARE AND SOFTWARE TO SUPPORT EXTENSION OF FIRE ALARM SYSTEM. F. VISUAL DEVICES TO BE IN SYNC WITH EACH OTHER AND AUDIBLE DEVICES TO BE IN SYNC WITH EACH OTHER. G. AUDIBLE AND VISUAL DEVICES TO BE ON DIFFERENT CIRCUITS. H. STROBES TO BE 75 CANDELA EVERYWHERE. I. VOLTAGE DROP AND BATTERY LOAD CALCULATIONS TO BE PROVIDED AND VERI FI ED AT SUBMI TTAL PROCESS. J. FIRE ALARM SYSTEM SHALL BE NETWORKED WITH EXISTING SYSTEM. K. FURNISH TVSS PER SPECIFICATIONS ON ALL COPPER CABLING ENTERING THE BUILDING. L. THE CONTRACTOR SHALL PROVIDE CONNECTION TO THE OWNERS EXISTING NOTIFIER FIRE ALARM SYSTEM. PROVIDE ALL NECESSARY SYSTEM CABINETS, POWER SUPPLIES, MICRO-CONTROLLERS, KEYBOARD DISPLAYS, LED DISPLAYS, BATTERIES PERIPHERAL DEVICES, VOICE EVACUATION SYSTEMS, ETC. FOR A COMPLETE AND FUNCTIONING SYSTEM. FIRE ALARM SYSTEM COMPONENTS SHALL MATCH EXISTING. M. THE SYSTEM SHALL COMPLY WITH ALL CURRENT, APPLICABLE CODES I NCLUDI NO THE FOLLOWI NO: 1. NATI ONAL ELECTRI CAL CODE( NEC) 2. NATIONAL FI RE PROTECTION AGENCY A. NFPA 72 B. NFPA 101 LIFE SAFETY CODE 3. ALL APPLICABLE UL STANDARDS 4. AMERI CANS WI TH DI SABI LI TI ES ACT ( ADA) 5. LOCAL CODE REQUIREMENTS N. CONTROL PANEL 1. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY HARDWARE AND SOFTWARE PROGRAMMING NECESSARY TO ACCOMMODATE MODIFICATIONS I NDI CATED ON DRAWI NOS. 0. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE EXISTING FIRE ALARM PROTECTION UNTIL NEW DEVICES HAVE BEEN PROPERLY CERTIFIED AND APPROVED BY THE AUTHORITY HAVING JURI SDI CTI ON. ALL EXI STI NG WI RI NG, BOXES, CONOUI TS SERVI NO THE DEVICES TO BE REMOVED SHALL BE DEMOLISHED. ALL INACTIVE WIRING SHALL BE LABELLED ' ABANDONED. DO NOT USE.' P. THE CONTRACTOR SHALL PROVIDE A RECORD OF COMPLETION FOR THE FIRE ALARM SYSTEM AND A SENSITIVITY REPORT FOR ALL SMOKE AND DUCT DETECTORS INSTALLED IN THE PROJECT AREA. 0. COORDINATE THE SHUTDOWN OF AIR HANDLER UNITS, EXHAUST FANS, ETC WITHIN THE PROJECT AREA WITH DIVISION 15. ELECTRICAL SHEET INDEX SHEET NUMBER DESCRIPTION EO.1 ELECTRICAL LEGEND, DETAILS AND SHEET INDEX E1.1 SEVENTH FLOOR PLAN - DEMOLITION - ELECTRICAL E2.1 SEVENTH FLOOR PLAN - NEW CONSTRUCTION - LIGHTING E3.1 SEVENTH FLOOR PLAN - NEW CONSTRUCTION - POWER AND SYSTEM E3.2 FOURTH FLOOR PLAN - NEW CONSTRUCTION - POWER E3.3 SIXTH FLOOR PLAN - NEW CONSTRUCTION - POWER E4.1 ELECTRICAL RISERS E5.1 PANEL SCHEDULES E5,2 ELECTRICAL STUDIES E6.1 ELECTRICAL SPECIFICATIONS E6.2 ELECTRICAL SPECIFICATIONS % •. 6I • Arch itect of Record: ARRAY Arch itects P.C. Y . :Yrr healthcare facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Baca Raton, FL 33487 t: 561.995.1700 f: 561.J'U5.1701 firm license number www.arr2yhfs.com AA2600890 SEAL: �` %1►5 Ol j''` i LENS No. 53588 pIR,l�pra�```� �0 NA ILt �1N�� CONSULTANTS: Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 _ www.ssr- ine.com Firm Certification - EB- 0000857 Dennis O. Davis PE - 58588 John E. Moulder PE - 33200 SSR JOB * 1232010.0 OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: INTERIOR RENOVATIONS FOR CENTRAL MONITORING ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 AHCA: CLIENT CODE /FILE NUMBER: 23/100154 PROJECT ID /SUBMISSION NUMBER: 187 -1 2 Bid and Permit Set 07 -18 -12 1 AHCA Stage III 07 -03 -12 NO. DESCRIPTION DATE REVISIONS /ISSUES SHEET TITLE: ELECTRICAL LEGEND, DETAILS AND SHEET INDEX DRAWN: CHECKED: CON /REF No. 0000 PROJECT No. 3606 DATE: 07 -03 -12 SCALE: As Indicated SHEET NO. E0.1 This d- ci.m7ent Is o coo },ighr F.mfec>ed ir0rilmr.- of ser,-i -e, proper wf AiRA: and lice ;ed for u.,., it Ui tilled proe_t vile_ R-F ducI!of o u;,a d Ali- d u, 1er withgj` writ en vr(Tlssloo of API AY i= illegal and will be -e�e( jfPd irder * law. ©COPYRIGHT - 2012 ARRAY HFS