12-984-039cu Q II : o- N 4j I � 0 N Li N j 3 3 E- al C.. L• 0 a 0 I � r �F3. 5 [l DEMOLITION LEGEND SYMBOL DESCRIPTION 1 EXISTING TO REMAIN 07 -03 -12 NO. EXISTING TO BE REMOVED DATE REMOVE EXISTING TO THIS POINT -- GENERAL NOTES: I. CONTRACTOR SHALL PHASE WORK AS DIRECTED BY ARCHITECTURAL DRAWINGS AND OWNER. 2. CONTRACTOR SHALL PATCH WALLS, FLOORS, AND CEILINGS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF FIRE PROTECTION SYSTEMS. COORDINATE WITH ARCHITECTURAL DRAWINGS. } 3. THE HOSPITAL IS OPEN 24 HOURS A DAY, 7 DAYS A WEEK. THE CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: 0 A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. 11 C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. 11 D. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER R& DURATION OF SHUTDOWNS REQUIRED. WHERE FEASIBLE INSTALL NEW MAINS PRIOR TO DEMOLITION OF EXISTING. I 4. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 5. PIPING SHOWN TO BE REMOVED IS NOT TO BE CAPPED AND ABANDONED11 6. CONTRACTOR SHALL COORDINATE TIMING, DURATION AND AREAS AFFECTED BY SHUTDOWNS WITH HOSPITAL IN ORDER TO FACILITATE REQUIRED FIRE WATCH. 7. CONTRACTOR SHALL COORDINATE NEW SPRINKLER HEAD LOCATIONS WITH I CEILING GRID, CEILING MOUNTED DEVICES (LIGHTS, DIFFUSERS, SMOKE DETECTORS, ETC.) AND OBSTRUCTIONS TO SPRINKLER THROW (SOFFITS, PRIVACY CURTAINS, ETC.) PER NFPA 13. a,1 KEYED NOTES: 0 no REMOVE EXISTING SPRINKLER HEAD AND ASSOCIATED BRANCH PIPING BACK TO LIMITS SHOWN. RAISE /OFFSET EXISTING A/S MAIN IF REQUIRED BY NEW SERVICES ROUTED ABOVE CEILING. PROVIDE WITH NEW HANGERS. z I 7. _. ........ N sees ••Y . sees• .•• . • % • • r A l'cl i 4cct of Record: r r • • Y Y • • • „ • • • .10. r • • Y r sees • •rr�u • ••• � I � �- � N H �?� N't M 1V Arch itects P.C. b-61.theare facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Roca Raton, FL 33427 t: 561.995.1700 f: 561.995.1701 firm license number www.arrayhfs.com AA2600890 . SEAL: / ✓ � � r 3 1 ='U: •� OF 0R1 Nom` CONSULTANTS: Smith Seckman 1 Reid , Inc. 600 West Hillsboro, Suite 300 Deerfield Beach., FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Certification EB- 0000857 Dennis O. Davis PE - 58588 John E. Moulder PE - 33200 SSR JOB * 1232010.0 HOSPITAL: ................... SOUTH MIAMI HOSPITAL PROJECT: INTERIOR RENOVATIONS FOR CENTRAL MONITORING ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 AHCA: CLIENT CODE /FILE NUMBER: 23/100154 PROJECT ID /SUBMISSION NUMBER: 167 -1 2 Bid and Permit Set 07 -15 -12 1 AHCA Stage III 07 -03 -12 NO. DESCRIPTION DATE REVISIONS /ISSUES DRAWN: CHECKED: CON /REF No. 0000 PROJECT No. 3606 DATE: 07 -03 -12 SCALE: As Indicated SHEET NO. FP1 0 1 This dccurnw is a cop right Fr; ..-,.1 instium r, sx e, : eper-� ct AURA' and li.er,ed for c ri tl i I.d Pro -dk. R du,aior r i, r Ii 1 .irvi,rc wi,hoat wntl�n P�-rr iss.r M APRa i�. illFgil pnd will Lt ,rc ._ jt�d i d -r -h= la'rv. ©COPYRIGHT - 2012 ARRAY HFS