12-984-025t 0 c.+ c 0 C14 i V) I cn rn I LO Q 0 x Ln I � C"5 u i N CL Ln j N M cv 00 cN CD cv w LL. 0 C U, SECTION 078446 - FIRE - RESISTIVE JOINT 13YSTEMS 1.1 SUMMARY A. JOINTS IN OR BETWEEN FIRE - RESISTANCE -RATED CONSTRUCTIONS. B. JOINTS AT EXTERIOR CURTAIN- WALLIFLOOR INTERSECTIONS, C. JOINTS IN SMOKE BARRIERS. 1.2 QUALITY ASSURANCE A. INSTALLER QUALIFICATIONS: A FIRM THAT HAS BEEN APPROVED BY FM GLOBAL ACCORDIN'' TO FM GLOBAL 4991, "APPROVAL OF FIRESTOP CONTRACTORS," OR BEEN EVALUATED BY UL AND FOUND TO COMPLY WITH UL'S "QUALIFIED FIRESTOP CONTRACTOR PROGRAM REQUIREMENTS." B. FIRE- TEST - RESPONSE CHARACTERISTICS: FIRE - RESISTIVE JOINT SYSTEMS SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: 1. FIRE- RESISTIVE JOINT SYSTEM TESTS ARE PERFORMED BY UL. 1.3 FIRE - RESISTIVE JOINT SYSTEMS A. WHERE REQUIRED, PROVIDE FIRE - RESISTIVE JOINT SYSTEMS THAT ARE PRODUCED AND INSTALLED TO RESIST SPREAD OF FIRE ACCORDING TO REQUIREMENTS INDICATED, RESIST PASSAGE OF SMOKE AND OTHER GASES, AND MAINTAIN ORIGINAL FIRE - RESISTANCE RATING OF ASSEMBLIES IN OR BETWEEN WHICH FIRE - RESISTIVE JOINT SYSTEMS ARE INSTALLED. FIRE - RESISTIVE JOINT SYSTEMS SHALL ACCOMMODATE BUILDING MOVEMENTS WITHOUT IMPAIRING THEIR ABILITY TO RESIST THE PASSAGE OF FIRE AND HOT GASES. B. JOINTS IN OR BETWEEN FIRE- RESISTANCE -RATED CONSTRUCTION: RATINGS DETERMINED PER ASTM E 1966 OR UL 2079: C. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. HILTI, INC. 2. SPECIFIED TECHNOLOGIES INC. 3. 3M FIRE PROTECTION PRODUCTS. 4. TREMCO, INC.; TREMCO FIRE PROTECTION SYSTEMS GROUP. 5. USG CORPORATION. D. JOINTS IN SMOKE BARRIERS: RATINGS DETERMINED PER UL 2079, 1. L- RATING: NOT EXCEEDING 5.0 CFM /FT (0.00775 CU. MIS X M) OF JOINT AT 0.30 INCH WG (74.7 PA) AT BOTH AMBIENT AND ELEVATED TEMPERATURES. E. EXPOSED FIRE- RESISTIVE JOINT SYSTEMS: PROVIDE PRODUCTS WITH FLAME-SPREAD AND SMOKE - DEVELOPED INDEXES OF LESS THAN 25 AND 450, RESPECTIVELY, AS DETERMINED PER ASTM E 34. F. ACCESSORIES: PROVIDE COMPONENTS OF FIRE - RESISTIVE JOINT SYSTEMS, INCLUDING PRIMERS AND FORMING MATERIALS, THAT ARE NEEDED TO INSTALL FILL MATERIALS AND TO MAINTAIN RATINGS REQUIRED, USE ONLY COMPONENTS SPECIFIED BY FIRE - RESISTIVE JOINT SYSTEM MANUFACTURER AND APPROVED BY THE QUALIFIED TESTING AGENCY FOR SYSTEMS INDICATED. 1.4 INSTALLATION A. EXAMINE SUBSTRATES AND CONDITIONS, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR JOINT CONFIGURATIONS, SUBSTRATES, AND OTHER CONDITIONS AFFECTING PERFORMANCE OF THE WORK. B. INSTALL FIRE - RESISTIVE JOINT SYSTEMS TO COMPLY WITH MANUFACTURER'S WRITTEN INSTALLATION; INSTRUCTIONS AND PUBLISHED DRAWINGS FOR PRODUCTS AND APPLICATIONS INDICATED. C. INSTALL FORMING MATERIALS AND OTHER ACCESSORIES OF TYPES REQUIRED TO SUPPORT FILL MATERIALS DURING THEIR APPLICATION AND IN POSITION NEEDED TO PRODUCE CROSS- SECTIONAL SHAPES AND DEPTHS REQUIRED TO ACHIEVE FIRE RATINGS INDICATED, 1. AFTER INSTALLING FILL MATERIALS AND ALLOWING THEM TO FULLY CURE, REMOVE COMBUSTIBLE FORMING MATERIALS AND OTHER ACCESSORIES NOT INDICATED AS PERMANENT COMPONENTS OF FIRE - RESISTIVE JOINT SYSTEM. D. INSTALL FILL MATERIALS FOR FIRE - RESISTIVE JOINT SYSTEMS BY PROVEN TECHNIQUES TO PRODUCE THE FOLLOWING RESULTS: 1. FILL VOIDS AND CAVITIES FORMED BY JOINTS AND FORMING MATERIALS AS REQUIRED TO ACHIEVE FIRE - RESISTANCE RATINGS INDICATED. 2. APPLY FILL MATERIALS SO THEY CONTACT AND ADHERE TO SUBSTRATES FORMED BY JOINTS. 3. FOR FILL MATERIALS THAT WILL REMAIN EXPOSED AFTER COMPLETING THE WORK, FINISH TO PRODUCE SMOOTH, UNIFORM SURFACES THAT ARE FLUSH WITH ADJOINING FINISHES. 1.5 FIELD QUALITY CONTROL A. INSPECTING AGENCY: OWNER WILL ENGAGE A QUALIFIED TESTING AGENCY TO PERFORM TESTS AND INSPECTIONS. 1. WHERE DEFICIENCIES ARE FOUND OR FIRE - RESISTIVE JOINT SYSTEMS ARE DAMAGED OR REMOVED DUE TO TESTING, REPAIR OR REPLACE FIRE - RESISTIVE JOINT SYSTEMS SO THEY COMPLY WITH REQUIREMENTS. C. PROCEED WITH ENCLOSING FIRE- RESISTIVE JOINT SYSTEMS WITH OTHER CONSTRUCTION ONLY AFTER INSPECTION REPORTS ARE ISSUED AND INSTALLATIONS COMPLY WITH REQUIREMENTS. END OF SECTION 071446 SECTION 092900 - GYPSUM BOARD 1.1 THIS SECTION INCLUDES THE FOLLOWING: A. INTERIOR GYPSUM BOARD 1.2 QUALITY ASSURANCE A. FIRE - RESISTANCE -RATED ASSEMBLIES: FOR FIRE - RESISTANCE -RATED ASSEMBLIES, PROVIDE MATERIALS AND CONSTRUCTION IDENTICAL TO THOSE TESTED IN ASSEMBLY INDICATED ACCORDING TO ASTM E 119 BY AN INDEPENDENT TESTING AGENCY, A. STC -RATED ASSEMBLIES: FOR STC -RATED ASSEMBLIES, PROVIDE MATERIALS AND CONSTRUCTION IDENTICAL TO THOSE TESTED IN ASSEMBLY INDICATED ACCORDING TO ASTM E 90 AND CLASSIFIED ACCORDING TO ASTM E 413 BY AN INDEPENDENT TESTING AGENCY, 13 INTERIOR GYPSUM BOARD A. GENERAL: COMPLYING WITH ASTM C 361C 36M OR ASTM C 13961C 1396M, AS APPLICABLE TO TYPE OF GYPSUM BOARD INDICATED AND WHICHEVER IS MORE STRINGENT. 1. TYPE X: THICKNESS: 518 INCH (15.9 MM). LONG EDGES: TAPERED. 2. FLEXIBLE TYPE: MANUFACTURED TO BEND TO FIT RADII AND TO BE MORE FLEXIBLE THAN STANDARD REGULAR -TYPE GYPSUM BOARD OF SAME THICKNESS. a. THICKNESS: 114 INCH (6.4 MM). LONG EDGES: TAPERED. 3. CEILING TYPE: MANUFACTURED TO HAVE MORE SAG RESISTANCE THAN REGULAR -TYPE GYPSUM BOARD. a. THICKNESS: 112 INCH (12.7 MM). LONG EDGES: TAPERED. 1.4 AUXILIARY MATERIALS A. GENERAL: PROVIDE AUXILIARY MATERIALS THAT COMPLY WITH REFERENCED INSTALLATION STANDARDS AND MANUFACTURER'S WRITTEN RECOMMENDATIONS, B. STEEL DRILL SCREWS: ASTM C 1002, UNLESS OTHERWISE INDICATED. 1. USE SCREWS COMPLYING WITH ASTM C 954 FOR FASTENING PANELS TO STEEL MEMBERS FROM 0.033 TO 0.112 INCH (0.84 TO 2.84 MM) THICK, 2. FOR FASTENING CEMENTITIOUS BACKER UNITS, USE SCREWS OF TYPE AND SIZE RECOMMENDED BY PANEL MANUFACTURER, 1.5 APPLYING AND FINISHING PANELS, GENERAL A. COMPLY WITH ASTM C 140. 1. EXAMINE PANELS BEFORE INSTALLATION. REJECT PANELS THAT ARE WET, MOISTURE DAMAGED, AND MOLD DAMAGED, C. ISOLATE PERIMETER OF GYPSUM BOARD APPLIED TO NON - LOAD - BEARING PARTITIONS AT STRUCTURAL ABUTMENTS, EXCEPT FLOORS. PROVIDE 114- TO 1/2 -INCH- (6.4- TO 12.7 -MM -) WIDE SPACES AT THESE LOCATIONS, AND TRIM EDGES WITH EDGE TRIM WHERE EDGES OF PANELS ARE EXPOSED. SEAL JOINTS BETWEEN EDGES AND ABUTTING STRUCTURAL SURFACES WITH ACOUSTICAL SEALANT. 1.6 APPLYING INTERIOR GYPSUM BOARD A. INSTALL INTERIOR GYPSUM BOARD IN THE FOLLOWING LOCATIONS: 1. TYPE X: VERTICAL SURFACES, UNLESS OTHERWISE INDICATED. 2, FLEXIBLE TYPE: APPLY IN DOUBLE LAYER AT CURVED ASSEMBLIES. 3. CEILING TYPE: CEILING SURFACES AND SOFFIT. 1.7 INSTALLING TRIM ACCESSORIES A. GENERAL: FOR TRIM WITH BACK FLANGES INTENDED FOR FASTENERS, ATTACH TO FRAMING WITH SAME FASTENERS USED FOR PANELS. OTHERWISE, ATTACH TRIM ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS, D. CONTROL JOINTS: INSTALL CONTROL JOINTS ACCORDING TO ASTM C 840 AND IN SPECIFIC LOCATIONS APPROVED BY ARCHITECT FOR VISUAL EFFECT. C. INTERIOR TRIM: INSTALL N THE FOLLOWING LOCATIONS: 1. CORNERiEAD: USE AT OUTSIDE CORNERS, UNLESS OTHERWISE INDICATED. 2. BULLNOSE BEAD: USE AT OUTSIDE CORNERS 3. LC -BEAD: USE AT EXPOSED PANEL EDGES 4, L -BEAD: USE WHERE INDICATED 5, U -BEAD: USE WHERE INDICATED 6. CURVED -EDGE CORNERBEAD: USE AT CURVED OPENINGS. 1.8 FINISHING GYPSUM BOARD A. GYPSUM BOARD FINISH LEVELS: FINISH PANELS TO LEVELS INDICATED BELOW: 1. LEVEL 1: CEILING PLENUM AREAS, CONCEALED AREAS, AND WHERE INDICATED. 2. LEVEL 2: PANELS THAT ARE SUBSTRATE FOR TILE 3. LEVEL 3: ABOVE CEILING ON FIRE RATED WALLS 4, LEVEL 4: AT PANEL SURFACES THAT WILL BE EXPOSED TO VIEW, UNLESS OTHERWISE INDICATED a. PRIMER AND ITS APPLICATION TO SURFACES ARE SPECIFIED IN OTHER DIVISION 09 SECTIONS. 5. LEVEL 5: ALL PANEL SURFACE TO RECEIVING HIGH AND SEMIGLOSS PAINT END OF SECTION 092900 3 4 SECTION 096518 • RESILIENT SHEET FLOORING 1.1 THIS SECTION INCLUDES: VINYL AND RU BIER FLOORING. 1.2 SUBMITTALS A. SAMPLES: FOR EACH COLOR AND TEXTURE REQUIRED, LABEL EACH SAMPLE WITH MANUFACTURER'S NAME, MATERIAL DESCRIPTION, COLOR, PATTERN, AND DESIGNATION INDICATED ON DRAWINGS AND IN SCHEDULES, 1. SAMPLES: 12 "X12" OF EACH COLOR AND PATTERN OF FLOORING REQUIRED. 1.3 QUALITY ASSURANCE A. INSTALLER QUALIFICATIONS: A QUALIFIED INSTALLER WHO EMPLOYS WORKERS FOR THIS PROJECT WHO ARE COMPETENT IN TECHNIQUES REQUIRED BY MANUFACTURER FOR FLOORING INSTALLATION INDICATED. B. FIRE - TEST - RESPONSE CHARACTERISTICS: AS DETERMINED BY TESTING IDENTICAL PRODUCTS ACCORDING TO ASTM E 641 OR NFPA 253 BY A QUALIFIED TESTING AGENCY. 1, CRITICAL RADIANT FLUX CLASSIFICATION: CLASS I, NOT LESS THAN 0.45 WISQ. CM. 1.4 RESILIENT FLOORING: MANUFACTURER: SEE FINISH DRAWING FOR MANUFACTURER, STYLE AND COLOR. 1.5 INSTALLATION MATERIALS A. TROWELABLE LEVELING AND PATCHING COMPOUNDS: LATEX - MODIFIED, PORTLAND CEMENT BASED OR BLENDED HYDRAULIC-CEMENT- BASED FORMULATION PROVIDED OR APPROVED BY MANUFACTURER FOR APPLICATIONS INDICATED. 1. ADHESIVES: WATER - RESISTANT TYPE RECOMMENDED BY MANUFACTURER TO SUIT FLOORING AND SUBSTRATE CONDITIONS INDICATED. I. USE ADHESIVES THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOC CONTENT WHEN CALCULATED ACCORDING T040 CFR 59, SUBPART D (EPA METHOD 24): a. VCT AND ASPHALT TILE ADHESIVES: NOT MORE THAN 50 GIL. 1.6 EXAMINE SUBSTRATES, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR MAXIMUM MOISTURE CONTENT AND OTHER CONDITIONS AFFECTING PERFORMANCE OF THE WORK. 1.7 PREPARATION A. PREPARE SUBSTRATES ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS TO ENSURE ADHESION OF RESILIENT PRODUCTS. C FILL CRACKS, HOLES, AND DEPRESSIONS IN SUBSTRATES WITH TROWELABLE LEVELING AND PATCHING COMPOUND AND REMOVE DUMPS AND RIDGES TO PRODUCE A UNIFORM AND SMOOTH SUBSTRATE. C. DO NOT INSTALL FLOORING UNTIL IT IS THE SAME TEMPERATURE AS SPACE WHERE IT IS TO BE INSTALLED. D. SWEEP AND VACUUM CLEAN SUBSTRATES TO BE COVERED BY RESILIENT PRODUCTS IMMEDIATELY BEFORE INSTALLATION. 1.8 FLOORING INSTALLATION A. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLING FLOORING. B. SCRIBE, CUT, AND FIT FLOORING TO BUTT NEATLY AND TIGHTLY TO VERTICAL SURFACES AND PERMANENT FIXTURES INCLUDING BUILT -IN FURNITURE, CABINETS, PIPES, OUTLETS, AND DOOR FRAMES. D. EXTEND FLOORING INTO TOE SPACES, DOOR REVEALS, CLOSETS, AND SIMILAR OPENINGS. EXTEND FLOORING TO CENTER OF DOOR OPENINGS. 1.9 CLEANING AND PROTECTION A. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR CLEANING AND PROTECTION OF FLOORING. 1. PERFORM THE FOLLOWING OPERATIONS IMMEDIATELY AFTER COMPLETING FLOORING INSTALLATION: 1. REMOVE ADHESIVE AND OTHER BLEMISHES FROM EXPOSED SURFACES. 2. SWEEP AND VACUUM SURFACES THOROUGHLY. 3. DAMP -MOP SURFACES TO REMOVE MARKS AND SOIL. C. PROTECT FLOORING PRODUCTS FROM MARS, MARKS, INDENTATIONS, AND OTHER DAMAGE FROM CONSTRUCTION OPERATIONS AND PLACEMENT OF EQUIPMENT AND FIXTURES DURING REMAINDER OF CONSTRUCTION PERIOD. END OF SECTION 096519 SECTION 096513 - RESILIENT BASE AND ACCESSORIES 1.1 THIS SECTION INCLUDES: A. RESILIENT BASE 1. REDUCER STRIP 1.2 SUBMITTALS A. SAMPLES: FOR EACH OF THE FOLLOWING PRODUCTS AND FOR EACH COLOR AND TEXTURE REQUIRED. LABEL EACH SAMPLE WITH MANUFACTURER'S NAME, MATERIAL DESCRIPTION, COLOR, PATTERN, AND DESIGNATION INDICATED ON DRAWINGS AND IN SCHEDULES. 1. BASE: MINIMUM OF 12 INCH LONG SAMPLE. 2. REDUCER STRIP: MINIMUM OF 3 INCH LONG SAMPLE 1.3 QUALITY ASSURANCE A. INSTALLER QUALIFICATIONS: AN EXPERIENCED INSTALLER WHO IS CERTIFIED BY THE FLOOR COVERING INSTALLATION BOARD OR WHO CAN DEMONSTRATE COMPLIANCE WITH ITS CERTIFICATION PROGRAM REQUIREMENTS. B. FIRE - TEST - RESPONSE CHARACTERISTICS: AS DETERMINED BY TESTING IDENTICAL PRODUCTS ACCORDING TO ASTM E 641 OR NFPA 253 BY A QUALIFIED TESTING AGENCY. 1. CRITICAL RADIANT FLUX CLASSIFICATION: CLASS 1, NOT LESS THAN 0.45 WISQ. CM. 1.4 RESILIENT BASE A. MANUFACTURER: SEE FINISH DRAWING FOR MANUFACTURER, STYLE AND COLOR. 1.5 INSTALLATION ACCESSORIES A. TROWELABLE LEVELING AND PATCHING COMPOUNDS: LATEX- MODIFIED, PORTLAND CEMENT BASED OR BLENDED HYDRAULIC - CEMENT -BASED FORMULATION PROVIDED OR APPROVED BY MANUFACTURER FOR APPLICATIONS INDICATED. 1. ADHESIVES: WATER - RESISTANT TYPE RECOMMENDED BY MANUFACTURER TO SUIT RESILIENT PRODUCTS AND SUBSTRATE CONDITIONS INDICATED. 1. USE ADHESIVES THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOC CONTENT WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24): a. COVE BASE ADHESIVES: NOT MORE THAN 50 GIL, C. METAL EDGE STRIPS: EXTRUDED ALUMINUM WITH MILL FINISH OF WIDTH SHOWN, OF HEIGHT REQUIRED TO PROTECT EXPOSED EDGES OF TILES, AND IN MAXIMUM AVAILABLE LENGTHS TO MINIMIZE RUNNING JOINTS, 1.6 EXAMINATION A. EXAMINE SUBSTRATES, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR MAXIMUM MOISTURE CONTENT AND OTHER CONDITIONS AFFECTING PERFORMANCE OF THE WORK. 1.7 PREPARATION A. PREPARE SUBSTRATES ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS TO ENSURE ADHESION OF RESILIENT PRODUCTS. B. FILL CRACKS, HOLES, AND DEPRESSIONS IN SUBSTRATES WITH TROWELAILE LEVELING AND PATCHING COMPOUND AND REMOVE BUMPS AND RIDGES TO PRODUCE A UNIFORM AND SMOOTH SUBSTRATE. C. DO NOT INSTALL RESILIENT PRODUCTS UNTIL THEY ARE SAME TEMPERATURE AS THE SPACE WHERE THEY ARE TO BE INSTALLED, D. SWEEP AND VACUUM CLEAN SUBSTRATES TO BE COVERED BY RESILIENT PRODUCTS IMMEDIATELY BEFORE INSTALLATION. 1.8 RESILIENT BASE INSTALLATION A. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLING RESILIENT BASE. 1. APPLY RESILIENT BASE TO WALLS, COLUMNS, PILASTERS, CASEWORK AND CABINETS IN TOE SPACES, AND OTHER PERMANENT FIXTURES IN ROOMS AND AREAS WHERE BASE IS REQUIRED. C. INSTALL RESILIENT BASE IN LENGTHS AS LONG AS PRACTICABLE WITHOUT GAPS AT SEAMS AND WITH TOPS OF ADJACENT PIECES ALIGNED. D. TIGHTLY ADHERE RESILIENT BASE TO SUBSTRATE THROUGHOUT LENGTH OF EACH PIECE, WITH BASE IN CONTINUOUS CONTACT WITH HORIZONTAL AND VERTICAL SUBSTRATES. E. DO NOT STRETCH RESILIENT BASE DURING INSTALLATION. F. ON MASONRY SURFACES OR OTHER SIMILAR IRREGULAR SUBSTRATES, FILL VOIDS ALONG TOP EDGE OF RESILIENT BASE WITH MANUFACTURER'S RECOMMENDED ADHESIVE FILLER MATERIAL. G. JOB - FORMED CORNERS: 1. OUTSIDE CORNERS: USE STRAIGHT PIECES OF MAXIMUM LENGTHS POSSIBLE. FORM WITHOUT PRODUCING DISCOLORATION (WHITENING) AT BENDS. 2. INSIDE CORNERS: USE STRAIGHT PIECES OF MAXIMUM LENGTHS POSSIBLE. 1.9 CLEANING AND PROTECTION A. COMPLY WITH MANUFACTURERS WRITTEN INSTRUCTIONS FOR CLEANING AND PROTECTION OF RESILIENT PRODUCTS. B. PERFORM THE FOLLOWING OPERATIONS IMMEDIATELY AFTER COMPLETING RESILIENT PRODUCT INSTALLATION: 1. REMOVE ADHESIVE AND OTHER BLEMISHES FROM EXPOSED SURFACES. 2. DAMP -MOP SURFACES TO REMOVE MARKS AND SOIL. C. PROTECT RESILIENT PRODUCTS FROM MARS, MARKS, INDENTATIONS, AND OTHER DAMAGE FROM CONSTRUCTION OPERATIONS AND PLACEMENT OF EQUIPMENT AND FIXTURES DURING REMAINDER OF CONSTRUCTION PERIOD, END OF SECTION 096513 5 6 SECTION 099123 - INTERIOR PAINTING 1.1 THIS SECTION INCLUDES SURFACE PREPARATION AND THE APPLICATION OF PAINT SYSTEMS ON THE FOLLOWING INTERIOR SUBSTRATES: A. GYPSUM BOARD 1.2 SAMPLES: FOR EACH COLOR AND TEXTURE REQUIRED. LABEL EACH SAMPLE WITH MANUFACTURER'S NAME, MATERIAL DESCRIPTION, COLOR, PATTERN, AND DESIGNATION INDICATED ON DRAWINGS AND IN SCHEDULES, A. DRAW DOWNS TO BE MINIMUM OF 6 INCH SQUARE SAMPLE 1.3 QUALITY ASSURANCE A_ MPI STANDARDS: 1. PRODUCTS: COMPLYING WITH MPI STANDARDS INDICATED AND LISTED IN "MPI APPROVED PRODUCTS LIST." 2. PREPARATION AND WORKMANSHIP: COMPLY WITH REQUIREMENTS IN "MPI ARCHITECTURAL PAINTING SPECIFICATION MANUAL" FOR PRODUCTS AND PAINT SYSTEMS INDICATED. 1.4 MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, SEE FINISH DRAWINGS FOR COLOR AND LOCATION, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: A. BENJAMIN MOORE & CO. B. DURON, INC. C. ICI PAINTS. D. M.A.B. PAINTS. E. PPG ARCHITECTURAL FINISHES, INC. F. SHERWIN- WILLIAMS COMPANY (THE). 1.5 PAINT, GENERAL A. VOC CONTENT OF FIELD - APPLIED INTERIOR PAINTS AND COATINGS: PROVIDE PRODUCTS THAT COMPLY WITH THE FOLLOWING LIMITS FOR VOC CONTENT, EXCLUSIVE OF COLORANTS ADDED TO A TINT BASE, WHEN CALCULATED ACCORDING TO 40 CFE 59, SUBPART D (EPA METHOD 24); THESE REQUIREMENTS DO NOT APPLY TO PAINTS AND COATINGS THAT RE APPLIED IN A FABRICATION OR FINISHING SHOP. 1, PRIMERSISEALERS: INTERIOR LATEX PRIMER /SEALER: MPI #50. C. METAL PRIMERS: RUST - INHIBITIVE PRIMER (WATER BASED): MPI 1#107. D WOOD PRIMERS: INTERIOR LATEX -BASED WOOD PRIMER: MPI 1#39. E. LATEX PAINTS: INSTITUTIONAL LOW- ODORNOC LATEX (SEMI- GLOSS): MPI #147 (GLOSS LEVEL 5), F. QUICK - DRYING ENAMELS: QUICK - DRYING ENAMEL (SEMI- GLOSS): MPI ;r#41(GLOSS LEVEL 5). 1.5 EXAMINE SUBSTRATES AND CONDITIONS, WITH APPLICATOR PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR MAXIMUM MOISTURE CONTENT AND OTHER CONDITIONS AFFECTING PERFORMANCE OF WORK. 1.6 PREPARATION A. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS IN "MPI ARCHITECTURAL PAINTING SPECIFICATION MANUAL" APPLICABLE TO SUBSTRATES INDICATED. B. GALVANIZED -METAL SUBSTRATES: REMOVE GREASE AND OIL RESIDUE FROM GALVANIZED SHEET METAL FABRICATED FROM COIL STOCK BY MECHANICAL METHODS TO PRODUCE CLEAN, LIGHTLY ETCHED SURFACES THAT PROMOTE ADHESION OF SUBSEQUENTLY APPLIED PAINTS. C. GYPSUM BOARD SUBSTRATES: DO NOT BEGIN PAINT APPLICATION UNTIL FINISHING COMPOUND IS DRY AND SANDED SMOOTH AND COMPOUND DUST IS REMOVED FOR THE SURFACE, 11 APPLICATION A. APPLY PAINTS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. B. TINT EACH UNDERCOAT A LIGHTER SHADE TO FACILITATE IDENTIFICATION OF EACH COAT IF MULTIPLE COATS OF SAME MATERIAL ARE TO BE APPLIED. TINT UNDERCOATS TO MATCH COLOR OF TOPCOAT, BUT PROVIDE SUFFICIENT DIFFERENCE IN SHADE OF UNDERCOATS TO DISTINGUISH EACH SEPARATE COAT. C. PAINTING MECHANICAL AND ELECTRICAL WORK: PAINT ITEMS EXPOSED IN EQUIPMENT ROOMS AND OCCUPIED SPACES. 1.1 CLEANING AND PROTECTION A. AFTER COMPLETING PAINT APPLICATION, CLEAN SPATTERED SURFACES. REMOVE SPATTERED PAINTS BY WASHING, SCRAPING, OR OTHER METHODS. DO NOT SCRATCH OR DAMAGE ADJACENT FINISHED SURFACES. B. PROTECT WORK OF OTHER TRADES AGAINST DAMAGE FROM PAINT APPLICATION. CORRECT DAMAGE TO WORK OF OTHER TRADES BY CLEANING, REPAIRING, REPLACING, AND REFINISHING, AS APPROVED BY ARCHITECT, AND LEAVE IN AN UNDAMAGED CONDITION, 1.9 INTERIOR PAINTING SCHEDULE A. GYPSUM BOARD SUBSTRATES: 1. INSTITUTIONAL LOW- ODOR/VOC LATEX SYSTEM: MPI INT 9.2M. a. PRIME COAT: INTERIOR LATEX PRIMERISEALER. b. INTERMEDIATE COAT: INSTITUTIONAL LOW- ODORNOC INTERIOR LATEX MATCHING TOPCOAT. c. TOPCOAT: INSTITUTIONAL LOW- ODORNOC INTERIOR LATEX EGGSHELL FINISH 2. HIGH - PERFORMANCE ARCHITECTURAL LATEX SYSTEM: MPI INT 9.25. (EPDXY PAINT USED ON PLUMBING WALLS OF TOILET ROOMS AND AS NOTED ON DRAWINGS) a. PRIME COAT: INTERIOR LATEX PRIMERISEALER. b. INTERMEDIATE COAT: HIGH - PERFORMANCE ARCHITECTURAL LATEX MATCHING TOPCOAT. c. TOPCOAT: HIGH - PERFORMANCE ARCHITECTURAL LATEX EGGSHELL FINISH END OF SECTION 099123 • • • • u • Y Y .. • r • • 'CITY 4I: S0UTH BUILDING OEPT. r;TF3UCTl.lr'..A L S :CT!(D N )vi iWl qY 0 0.096 see • i Y • • • r ••••Y r A R R A q��,.. .4 heare facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Baca Raton, FL 33487 f: 5681.995.1700 f: 561.995.1701 Bid and Permit Set firm license number 1 www.arrayhfs.com • Y • AA260008BO •1• Y Y DESCRIPTION r Y • REVISIONS /ISSUES r r u r SEAL: ••• ••• • • • • • u • Y Y .. • r • • 'CITY 4I: S0UTH BUILDING OEPT. r;TF3UCTl.lr'..A L S :CT!(D N )vi iWl qY 0 0.096 see • i Y • • • r ••••Y r A R R A q��,.. .4 heare facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Baca Raton, FL 33487 f: 5681.995.1700 f: 561.995.1701 Bid and Permit Set firm license number 1 www.arrayhfs.com 07 -03 -12 AA260008BO NO. DESCRIPTION DATE REVISIONS /ISSUES SEAL: " *AR00i MARK D. TAUDIEN '4,,"� f 1821 CONSULTANTS: Smith Seckman Et Reid, Inc. 600 West Hillsboro Blvd, Suite 300 Deerfield Beach, EL 33441 Phone: 954.421.1260 Fax: 954.421.1466 OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: INTERIOR RENOVATIONS FOR CENTRAL MONITORING ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 AHCA: CLIENT CODEIFILE NUMBER: 231100154 PROJECT ID/SUBMISSION NUMBER: 187 -1 2 Bid and Permit Set 07- 18--12 1 AHCA Stage III 07 -03 -12 NO. DESCRIPTION DATE REVISIONS /ISSUES SHEET TITLE: SPECIFICATIONS DRAWN: FL CHECKED: MDT CONIREF No. 00000 PROJECT No, 3606 DATE: 07 -03 -12 SCALE: 12" = 1' -0" A -803 N_ .a€ ent is e m briyet pro!e0..G ...st.:.r.e .. of ,pre {erty cf A?t?�,"- and licinsed far lse it the ttlpj spa ^ICct oily Reprodixtcr yr ese e# tT d u.^ert ry tr aul ::ritten perRissl(rfe .:° r ft,e is Ptgal c. d � 6t prustcul,ed un xAr ire k N @COPYRIGHT - 2012 ARRAY HFS