Loading...
12-984-022E 17 . C FF�� 1 2 3 4 DOOR SCHEDULE - CENTRAL MONITORING DOOR # Type Mark DOOR FRAME GLAZING FIRE RATING HARDWARE SETS REMARKS SIZE MATERIAL FINISH MATERIAL FINISH WIDTH HEIGHT ITHICKNESS EX. EX 31-011 7' - 0" Of - 2" EXST. EX HM PT -2 = HOLLOW METAL GHM 3 AL 700 E 3' - 0" 7'- 0" 0'- 1 314" SCV WTF HM PT -2 CTG MP 2 AL 702 A 3' - 0" 7'- 0" 0'- 1 314" SCV WTF HM PT -2 - 45 MIN (C) 1 5 � 1. NUMBER SEE FLOOR PLAN FOR DOOR NUMBER 2. DOOR ELEVATION: SEE TYPES BELOW SEE SCHEDULE SEE SHEDULE — 7 I u� Pia W I J TYPE A TYPE AA 3, DOOR SIZE: SEE SCHEDULE FOR WIDTH, HEIGHT AND THICKNESS 4, DOOR MATERIAL: SCV = SOLID CORE W1 WOOD VENEER FACES SCH = SOLID CORE W1 HARDBOARD FACES SCP = SOLID CORE PLASTIC LAMINATE FACES SCA = SOLID CORE ACROVYN FACES HM = HOLLOW METAL GHM = GALVANIZED HOLLOW METAL AL = ALUMINUM & GLASS LL = LEAD LINED 5. DOOR FINISH: WTF = WOOD TRANSPARENT FINISH WOF = WOOD OPAQUE FINISH MGP = METAL GALVANIZED PAINTED MP = METAL PAINTED AL = ANODIZED ALUMINUM PL = PLASTIC LAMINATE ro WN A DOOR LEGEND SEE SCHEDULE SEE SHEDULE — I r 7 Ii I II L — J II Lr — TYPE E TYPE EE 6. GLASS TYPE: WG =114" WIRE GLASS CTG =114" CLEAR TEMPERED GLASS LG =114" LEADED GLASS FRG =114" FIRE RATED GLASS 7. FRAME ELEVATION: SEE HOLLOW METAL ELEVATION LEGEND 1. FRAME MATERIAL: WD = WOOD HM = HOLLOW METAL GHM = GALVANIZED HOLLOW METAL AL = ALUMINUM KD = HOLLOW METAL KNOCK DOWN FRAME HMLL = HOLLOW METAL, LEAD LINED eL.' � f,i•d 5 � i �Y� .. Y�L,�G^� N "r1 10,102 WTF = WOOD TRANSPARENT FINISH WOF = WOOD OPAQUE FINISH MGP = METAL GALVANIZED PAINTED MP = METAL, PAINTED AL = ANODIZED ALUMINUM HMLL = HOLLOW METAL, LEAD LINED _ _� } Or L�uIwC 10 1'.'�TLi s1G E v > i f10,14 CODE. G FLO IDA FIRE GET FORTH IF Ti 10. FRAME DETAILS: SEE FRAME DETAILS ON SHEET 11. UL RATING: 20M1- 45M -1 1 H; 1.5 H;2 H; 3H 12. HARDWARE SET: SEE HARDWARE SETS IN SPECIFICATIONS. 7 • • Y �N • DOOR AND BORROWED LIGHT SCHEDULE GENERAL NOTES 1. DOOR NUMBERING MAY NOT BE SEQUENTIAL. DOORS ARE NUMBERED TO MATCH THE ROOM NUMBERING. • • • ° •uru 2. ALL FRAMES SHALL BE CAULKED CONTINUOUSLY TO WALL. : • Y Y 1 WHEREVER THERE IS A CRACK LEFT BETWEEN THE BOTTOM OF DOOR FRAME AND THE FINISH FLOOR, THE CONTRACTOR SHALL PROVIDE CAULKING TO SEAL CRACK 4. ALL THRESHOLDS SHALL CONFORM TO THE REQUIREMENTS OF THE MOST CURRENT EDITION OF ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES, THE AMERICAN WITH DISABILITIES ACT AND CHAPTER 11 OF THE BUILDING CODE. 5, NON -RATED DOORS MAY BE UNDERCUT ONE INCH MAXIMUM. DOORS IN RATED WALLS SHALL MEET THE REQUIREMENTS OF NFPA 80. 6, DOORS SCHEDULED TO HAVE A FIRE RATING LABEL SHALL HAVE A METAL LABEL PERMANENTLY AFFIXED TO BOTH THE DOOR AND FRAME. A VINYL LABEL AND EMBOSSED LABEL IN THE FRAME IS UNACCEPTABLE. 7. THE CONTRACTOR SHALL VERIFY THAT CLOSERS AND OTHER HARDWARE WILL ALLOW THE DOOR TO OPEN 110 DEGREES WHEN SUCH DOOR SWINGS ARE INDICATED ON THE FLOOR PLAN AND/ OR THIS SCHEDULE. B. ALL INTERIOR DOORS SHALL BE SOLID CORE, PRE - FINISHED UNLESS OTHERWISE NOTED IN THE SPECIFICATION. 9. ALL INTERIOR DOORS WITH CLOSER SHALL HAVE CLOSERS ADJUSTED TO 5 LB MAXIMUM PULL FORCE. 10. ALL DOORS WITH CLOSERS SHALL HAVE KICK PLATES. 11. DOORS SCHEDULED TO RECEIVE VIEW PANELS SHALL HAVE WOOD BEAD FRAME SURROUNDED IN SPECIES TO MATCH DOOR FINISH. FIRE RATED DOORS SHALL HAVE FIRE RATED WOOD BEAD. 12. ALL FRAMES SHALL BE 16 GAUGE, DOUBLE RABBETED AND PRIMED TO RECEIVE PAINT. 13. ALL HARDWARE IN RATED DOORS SHALL MEET THE REQUIREMENTS OF NFPA 80. 14. ALL STAIRWELL DOORS SHALL HAVE A MAXIMUM TEMPERATURE RISE OF 450 DEGREES FAHRENHEIT. DOOR FRAME DETAILS GENERAL NOTES 1. THROAT SIZE VARIES WITH STUD SIZES AND LAYERS OF GYPSUM WALLBOARD 2. SEE FLOOR PLANS AND PARTITION TYPES FORTH ROAT DIMENSIONS. 3. UNLESS NOTED OTHERWISE ALL DOOR FRAMES TO BE 6" FROM PERPENDICULAR WALLS. CROSS CORRIDOR SMOKE DOORS FRAMES TO BE 4" FROM PERPENDICULAR WALLS. DOOR HARDWARE SCHEDULE HARDWARE SET NO. 1: RATED 1 OVERHEAD CLOSER 3 BUTT HINGES -1 112" 1 STORE ROOM LOCKSET 1 WALL STOP 2 MOP PLATES 3 SILENCERS HARDWARE SET NO. 2: NON -RATED 3 BUTT HINGES -1 12' SWING CLEAR 1 WALL STOP 1 LOCKSET ELECTRIC STRIKE 1 CARD READER ACCESS 2 MOP PLATES 3 SILENCERS NOTE: CONTRACTOR SHALL MODIFY EXISTING H.M. FRAME FOR EXISTING DOOR 702 TO RECEIVE NEW ELECTRIC STRIKE TIED TO CARD ACCESS. HARDWARE SET NO.3 EXISTING TO REMAIN Y ` • ••Y•• • • r • • r r Y • Y Y••YY r • ■ Y r R • A R R A Y healthe6re facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Boer Raton, FL 33487 t. 561.995.1700 f; 561.995.1701 firm license number www.arrayhfs.com AA26000880 SEAL: OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: INTERIOR RENOVATIONS FOR CENTRAL MONITORING ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 AHCA: CLIENT CODE /FILE NUMBER: 231100154 PROJECT ID /SUBMISSION NUMBER: 187 -1 2 bid and Permit Set j 1 .'IMF. � ,• ,,! 07 -03 -12 . ,• `,� j �, �,. • i •C � ,, , .... MARK D. TALIDIEN • t is r., AR0011221 CONSULTANTS: Smith Seckman Et Reid, Inc. 600 West Hillsboro Blvd, Suite 300 Deerfield Beach, FL 33441 Phone: 954.421.1260 Fax: 954.421.1466 OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: INTERIOR RENOVATIONS FOR CENTRAL MONITORING ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 AHCA: CLIENT CODE /FILE NUMBER: 231100154 PROJECT ID /SUBMISSION NUMBER: 187 -1 2 bid and Permit Set 07 -1a -i2 1 AHCA Stage 111 07 -03 -12 NO. DESCRIPTION DATE REVISIONS /ISSUES SHEET TITLE: i 1 i DRAWN: EAS CHECKED: MDT CONCREE No. 00000 PROJECT No. 3606 DATE: 07 -03 -12 SCALE: As indicated A -701 This nmumsrt is o r.optx'ight protecfei instrur�enf of Service. prolprfy of ARRA; ;, -d license/ for use in the titled pTcject only. Raproductior or usn of t}?Is iocur�?er�! without written permission or AR Ar is "le(in! oni will be prosecuted urder t'e I v, G@COPYRIGHT - 2012 ARRAY HFS