12-984-021E C - C I i ca N B w LO M 0 4� x V) v CL V) u �.- In v II c'V N (N ca N co I � - LU 1 2 FIRE STOPPING SEALANT FASTEN RUNNER TO FLOOR/ROOF DECK ABOVE AS REQUIRED BY SPECIFICATIONS CARRY WALLBOARD TO UNDERSIDE OF STRUCTURAL SYSTEM ABOVE, AND SEAL TIGHT FINISHED CEILING 4 7/8" I - SOUND ATTENUATION FIRE BLANKET (SEE NOTE #3 FOR WHERE SOUND ATTENUATION BLANKET IS REQUIRED) 518" TYPE X GYPSUM WALLBOARD 3 518" METAL STUDS @ 16" O.C. MAX. 3 5/8" METAL TRACK FIRE STOPPING SEALANT UNFINISHED FLOOR SLAB TYPE 10 RATED WALL UL DES U465JLJ419 TYPE 10A 1 HOUR RATED STC 49 SMOKE BARRIER UL DES U465IU419 STC 49 PARTITION TYPE 22 1 1 12" 1' -0" FASTEN RUNNER TO FLOOR /ROOF DECK ABOVE AS REQUIRED BY SPECIFIATIONS CARRY WALLBOARD TO UNDERSIDE OF STRUCTURAL SYSTEM ABOVE, AND SEAL TIGHT FINISHED CEILING 4 7/8" SOUND ATTENUATION FIRE BLANKET (SEE NOTE *3 FOR WHERE SOUND ATTENUATION BLANKET IS REQUIRED) 51' TYPE X GYPSUM WALLBOARD 3 518" METAL STUDS @ 16" O.C. MAX. 3 5/8" METAL TRACK UNFINISHED FLOOR SLAB U" All TYPE 5 STC 49 PARTITION TYPE 23 CONT 22 GA 3" DEEP LEG SPRAY APPLIED FIRESTOP DEFLECTION TRACK .4 _ - MATERIAL EACH SIDE - ATTACH TO DECK AT 12" _ 4 '• = , ' . A PENETRATION. MIN 1120 OVERLAP AT GYP OC MAX IF GAP AROUND PENETRATION IS 1/4 OR LESS, PACK WITH 00 NOTED. LEAVE ALL SCREWS EXPOSED. t BD AND SLAB U.L. APPROVED FIRESTOP SEALANT P ATCHES SHALL BE TYPE X o DO NOT ATTACH GYP BD OR IF GAP AROUND PENETRATION IS GREATER THAN 114 ", PACK THICKNESS AS USED FOR TIGHTLY WITH THE SAFING INSULATION OR APPROVED STUDS TO DEFLECTION FIREPROOFING MAIL, AND APPLY PATCH AS SHOWN. THEN T FILL GAP BETWEEN TRACK IN THIS AREA �'� J SEALANT I I SLAB AND TOP OF CONT 2" WIDE X IF PIPE IS TO BE INSULATED, DO NOT RUN PIPE WALL WITH MINERAL 22 GA MTL STRAP - ATTACH I I CUT GYPSUM BOARD 3" WOOL INSULATION GYP BD TO STRAP AT 8" OC MAX PATCH TO WITHIN 114" OF MIN. MAX. MIN, APPROVED FIRESTOP SEALANT AS INDICATED BELOW, PENETRATION AND SEAL FLARE PIPE INSULATION ONTO FACE OF WALL AROUND NOTE: PIPE ON BOTH SIDES OF WALL, AND SEAL TO FACE OF PATCHING & SEALING PENETRATIONS IN REFER TO UL LISTING FOR -� CONT 2" WIDE X WALLS COMPLETE ASSEMBLY 22 GA MTL STRAP - ATTACH GYP BD REQUIREMENTS TO STRAP AT 8" OC MAX CONCRETE FLOOR OR ROOF SLAB ONE HOUR FIRE RATED AND ONE HOUR FIRE RATED SMOKE BARRIER UL -HW -D- 0108 PARTITION HEAD DETAILS E 1 1/2" = 1' -0" "� `• CONT 22 GA 3" DEEP • LEG DEFLECTION SEALANT — = r TRACK ATTACH TO DECK AT 12" OC MAX DO NOT ATTACH GYP - ---"^" �, BD OR STUDS TO DEFLECTION TRACK IN THIS AREA CONT 2" WIDE X 22 GA MTL STRAP FOR TOP ATTACHMENT OF GYP BD CONCRETE FLOOR OR ROOF NON -RATED OR SMOKE RESISTANT PARTITION HEAD DETAILS 1 1/2" = 1' -0" 3" CENTERLINE OF STUDS MIN. JOINT AT SECOND LAYER 0 0 0 0 TYPE'S' SCREWS MIN TWO PER SECTION 0 CUT GYPSUM BOARD PARCH TO PENETRATE AND SEAL 0— AS INDICATED BELOW 0 0 TYPE'G' SCREWS Q 6" Q.G. PROVIDE CONTN. BEAD ON JOINT COMPUND AROUND EDGES OF PATCH o —110 1 0 0 0 3” MIN M � � u w � M •Y•• •e• • • Y�Vti. •.• • Y • • f " Y M • •• •6i • • • '�.0 • • • • • . j • • • • • • • .... e - A RR A Y • Y • • •• •• • v y.... J f e•s• fees• 0 �� „ � , •:; • h altb0ire facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Boca Raton, FL 33487 t 561.995.1700 f: 561,995.1701 firm license number www.arrayhfs..com AA26000880 GENERAL NOTES THIS DETAIL IS NOT INTENDED FOR USE IN LIEU OF THE "BUTTER" BACK SIDE OF `'' AHCA St2ge III 7107-03-12 REQUIREMENTS IN FBC 712, BUT RATHER FOR SITUATIONS ALL PATCHES WITH DRY 0 0 Q 0 Ica IN WHICH PATCHING IS REQUIRED AFTER INSTALLATION OF WALL JOINT COMPUND, REVISIONS /ISSUES A PENETRATION. ATTACH WITH SCREWS AS 0 IF GAP AROUND PENETRATION IS 1/4 OR LESS, PACK WITH 00 NOTED. LEAVE ALL SCREWS EXPOSED. t < U.L. APPROVED FIRESTOP SEALANT P ATCHES SHALL BE TYPE X o GYUPSUM BOARD IN SAME IF GAP AROUND PENETRATION IS GREATER THAN 114 ", PACK THICKNESS AS USED FOR TIGHTLY WITH THE SAFING INSULATION OR APPROVED WALL 0 0 FIREPROOFING MAIL, AND APPLY PATCH AS SHOWN. THEN SEAL 114" MAXIMUM GAP WITH APPRRVED FIRESTOP JOINT AT SECOND LAYER �'� J SEALANT 3 Q TYPE'G' SCREWS IF PIPE IS TO BE INSULATED, DO NOT RUN PIPE 6 „ 6" INSULATION THROUGH THE WALL. AFTER PACKING GAP CUT GYPSUM BOARD 3" THROUGH WALL WITH SFAING INSULATION AND U.L. PATCH TO WITHIN 114" OF MIN. MAX. MIN, APPROVED FIRESTOP SEALANT AS INDICATED BELOW, PENETRATION AND SEAL FLARE PIPE INSULATION ONTO FACE OF WALL AROUND AS INDICATED AT RIGHT PIPE ON BOTH SIDES OF WALL, AND SEAL TO FACE OF PATCHING & SEALING PENETRATIONS IN WALL WITH INSULATION MASTIC. -� RATED WALLS AND /OR RATED SMOKE WALLS 1 1/211 = 1 1 -011 HEIGHT METAL STUDS HEIGHT METAL STUDS 1'-4" MAX. (TYP.) °` T TYPICAL MULTIPLE NONCOMBUSTIBLE CONDUIT OR PIPE PENETRATION THROUGH RATED WALLS AND /OR RATED SMOKE WALLS 1 1/211 = 11-01t METAL RUNNER BEHIND GYPSUM WALLBOARD PACK TIGHTLY WITH SAFING INSULATION FULL DEPTH OF WALL AND COMPLY WITH THE MOST STRINGENT OF 2004 FBC NONCOMBUSTIBLE CONDUIT OR PIPING SEAL: MARK. D. TAUDIEN "J �' " 0AR0011821 CONSULTANTS: x Smith Seckman £t Reid, Inc. 600 West Hillsboro BIVd, Suite 300 Deerfield Ruch, FL 33441 Phone: 954.421.1260 Fax: 954.421.1466 OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: INTERIOR RENOVATIONS FOR CENTRAL. MONITORING ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 AHCA: CLIENT CODE /FILE NUMBER: 23/100154 PROJECT ID /SUBMISSION NUMBFR: 187 -1 1 AHCA St2ge III 7107-03-12 NO. DESCRIPTION DATE REVISIONS /ISSUES SHEET nne: PARTITION TYPES AND CASEWORK DETAILS DRAWN: EAS CHECKED: MTB CON /REF No. 00000 PROJECT No. 3506 DATE: 07 -03 -12 SCALE: 1 112" = V -0" SHEEP N0. A -631 This dat.�lt.= i is n r Light p,,te,,Jed trstr of srrc . ��rta of ARRAY GnC icerxed tv use in the tine^ pro Zt orl - Reprocu4;iar u.r use of f }pis do;ajrn written permiss ^r 'r ARRAY is ikegol aril will be prese(aded urdenr the 1f;A COPYRIGHT - 2012 ARRAY HFS