Loading...
12-984-013C wo Bi V N Al DEMOLITION PLAN - SEVENTH FLOOR 1141! = 1 1-0" ICRA GENERAL NOTES PROVIDE INFECTION CONTROL PRECAUTIONS 7 CONTAINMENT SYSTEM AS REQUIRED BY HOSPITAL INFECTION CONTROL REPRESENTATIVE FOR ALL AREAS OUTSIDE THE LIMIT OF WORK. PROVIDE CONTAINMENT AT THE FLOOR ABOVE AND ADJACENT SPACES FOR ANY WORK IN THE CEILING PLENUM. SEE LIFE SAFETY PLANS FOR AREAS WITH ABOVE CEILING WORK ON OTHER FLOORS. ALL AREAS OF WORK TO COMPLY WITH ICRA AS REQUIRED BY HOSPITAL INFECTION CONTROL REPRESENTATIVE. ACTIONS TO BE PERFORMED DURING CONSTRUCTON OR MENOVA77ON 1. REMOVE AND ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT CONTAMINATION OF THE DUCT SYSTEM. 2. COMPLETE ALL CRITICAL BARRIERS I.E. SHEET ROCK, PLYWOOD, PLASTIC TO SEAL AREA FROM NON WORK AREA OR IMPLEMENT CONTROL CUBE METHOD (CART WITH PLASTIC COVERING AND SEALED CO WORK SITE WITH HEPA VACUUM PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS. 3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS. 4. CONTAIN CONSTRUCTION WASTE IN TIGHTLY COVERED CONTAINERS BEFORE TRANSPORTING. 5. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID. 6. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES APPROPRIATELY. ACTIONS TO BE PERFORMED UPON COMPLE77ON 1PRIOR TO OCCUPANCY 1. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS THOROUGHLY INSPECTED iiY OWNER'S STAFF. 2. VACUUM WORK WITH HEPA FILTERED VACUUMS. 3. WET MOP/WIPE EXPOSED SURFACES WITH APPROPRIATELY LABELED AND BHSF APPROVED HOSPITAL DISINFECTANT. 4, CONTAIN CONSTRUCTION WASTE IN TIGHTLY COVERED CONTAINERS BEFORE TRANSPORTING. 5. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID, 6. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED. 7, REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZES OF DIRT DEBRIS ASSOCIATED WITH CONSTRUCTION. i. FINAL CLEANING BY ENVIRONMENTAL SERVICES PRIOR TO OCCUPANCY. AM ICRA KEYNOTES ICI PROVIDE TEMPORARY FIRE RATED VISQUEEN CONSTRUCTIONIINFECTION CONTROL VESTIBULE FOR INSTALLATION OF NEW DOOR, IC2 PROVIDE STICKY WALK OFF MAT, BOTH SIDES OF DOOR, IC3 SEAL PERIMETER OF EXISTING DOOR DURING CONSTRUCTION IN ADJACENT AREAS. IC4 PROVIDE ICRA CONTROL MEASURES PER HOSPITAL STANDARDS IN ABOVE CEILING WORK DURING CONSTRUCTION LIFE SAFETY GENERAL NOTES 1. THE CONTRACTOR SHALL MAINTAIN ALL MEANS OF EGRESS FOR THE DURATION OF DEMOLITION 1 CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE FIRE RATED TEMPORARY PARTITIONS, AND COVERED WALKS TO MAINTAIN EGRESS AND SAFE PASSAGE FROM THE BUILDING TO THE PUBLIC WAY AND AS REQUIRED BY AUTHORITY HAVING JURISDICTION. 2. THE CONTRACTOR SHALL PROVIDE HEPA EXHAUST FANS TO KEEP SPACE WITHIN THE PROJECT AREA UNDER NEGATIVE PRESSURE AS LOCATIONS AND CONDITIONS DICTATE. 1 THE CONTRACTOR SHALL PROVIDE TEMPORARY PROTECTION WHILE WORKING IN THE SPACES BELOW OR ABOVE THE AREA OF DEMOLITION I CONSTRUCTION. 4. THE CONTRACTOR SHALL PROVIDE BARRIERS, TEMPORARY PARTITIONS TO PROTECT OCCUPANTS FROM PHYSICAL HAZARD AND NOISE DURING DEMOLITION I CONSTRUCTION. 5. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF CONSTRUCTION DOORS IN CONSTRUCTION BARRIERS, DOORS AND FRAMES IN CONSTRUCTION BARRIERS TO BE GASKET HOLLOW METAL DOORS TO BE SELF CLOSING AND LOCKABLE. ELEVATOR LOBBY FOR ALL CORRIDOR WORK: 5 6 7 ...Y ••• Y •Y • Y• "S "o Y r •.ii i i• i W DEMOLITION LEGEND DEMOLITION GENERAL NOTES CONTRACTOR RESPONSIBILITIES WITH 1. DEMOLITION IS INTENDED TO PREPARE THE BUILDING TO RECEIVE THE NEW REGARD TO EXIS r C?'CINDI CIG�N r;W WORK, THE INFORMATION PROVIDED IN NOWAY INTENDS TO MEAN THAT DEMOLITION N • • . w • • i Y • o • go* IS LIMITED ONLY TO THOSE ITEMS SPECIFICALLY IDENTIFIED. THE CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS OF CONSTRUCTION AND EQUIPMENT WITHIN THE - - - PROJECT AREA, INDICATED ON DEMOLITION PLAN, INCLUDING, BUT NOT LIMITED TO 1, THE CONTRACTOR SHALL PERFORM AS;TE VLSI AN DOING SG_ E,, : • • Y . _ _ - - E..•.""" C .,... �..., FLOOR MATERIAL, BASE, WALLS, CEILINGS, DOORS, DOOR FRAMES, CASEWORK, CONTRACTOR HAS AGREED THAT THEY HAVEINVESTIGATEb THE EXISTING ; ELECTRICAL, MECHANICAL, PLUMBING FIXTURES AND SYSTEM, AS REQUIRED TO CONDITIONS TO BE RENOVATED AND CONIPARL THEM TO THE WC> K TOiE,, . • • ` • ALLOW FOR THE EXECUTION OF NEW WORK. PERFORMED ACCORDING TO THE CONTM=OnMEINTt.` REMOVE EXISTING WALL CONSTRUCTION, SHOWN WITH DASHED LINES, IN ITS ENTIRETY FROM FLOOR TO STRUCTURE ABOVE INCLUDING DOORS, DOOR FRAMES, 2. THE OWNER SHALL REMOVE ALL NON - BUILT -IN EXISTING MEDICAL EQUIPMENT, 2. INFORMATION CONTAINED ON THESE DRAWINGS WITH REGARD TO EXISTING BORROWED LIGHTS, TERRAllO EASE, ASSOCIATED ELEC. I MECH. WORK, ETC. STORAGE UNITS AND FURNITURE, THE CONTRACTOR SHALL REMOVE SUPPORTS, CONDITIONS OF CONSTRUCTION IS PROVIDED FOR THE CONVENIENCE OF THE PREPARE AREA FOR NEW CONSTRUCTION. TRACKS, BUILT IN ITEMS (STORAGE CABINETS, CASEWORK, ETC.), ALONG WITH THE CONTRACTOR IN EXECUTING THE NEW WORK. EVERY ATTEMPT HAS BEEN MADE TO NORMAL DEMOLITION WORK. THE CONTRACTOR SHALL REMOVE AND TURN OVER TO PROVIDE COMPLETE AND ACCURATE REPRESENTATION OF SUCH EXISTING OWNER FOR STORAGE ANY ANCILLARY PIECES SUCH AS (BUT NOT LIMITED TO) CONDITIONS. THIS INTERPRETATION HAS BEEN TAKEN FROM DRAWINGS SUPPLIED ' MOUNTING BRACKETS, HARDWARE, MISC. SUPPORTS ITEMS, ETC. REQUIRED FOR THE BY OWNER AND HAS BEEN FURTHER SUPPLEMENTED WITH FIELD - MEASUREMENTS REINSTALLATION OF EQUIPMENT, AND OBSERVATIONS. THE INFORMATION CONTAINED IN THESE DRAWINGS, WITH REGARD TO THE EXISTING CONDITIONS OF CONSTRUCTION IN NO WAY RELEASES 3. THE CONTRACTOR SHALL REMOVE ALL ITEMS TO BE DEMOLISHED IN THEIR THE CONTRACTOR FROM THE RESPONSIBILITY FOR VERIFYING COMPLETELY ALL REMOVE EXISTING DOOR OR BORROWED LIGHT HOLLOW METAL FRAME ASSEMBLY, ENTIRETY INCLUDING ALL ASSOCIATED PIPING, WIRING, HANGERS, SUPPORTS, FIELD CONDITIONS RELATING TO THE EXECUTION OF THE WORK, AS DESCRIBED IN SHOWN WITH DASHED LINES. CLOSE EXISTING OPENING WITH METAL STUDS AT 16" PROJECTIONS, BOLTS, NAILS, ETC. FROM EXISTING SURFACES, AND PATCH ALL HOLES THESE CONTRACT DOCUMENTS. O.C. WITH GYPSUM BOARD ON EACH SIDE. ALIGN NEW WORK FLUSH WITH EXISTING TO MATCH ADJACENT SURFACES OR PROVIDE NEW SCHEDULED FINISHES, ADJACENT PARTITION. MATCH EXISTING WALL THICKNESS. 3. NO GUARANTEE IS MADE AS TO THE GENERAL CONDITIONS OF THE EXISTING 4. THE CONTRACTOR SHALL BRING TO THE ARCHITECT'S ATTENTION, FOR DECISION, BUILDING. THE CONTRACTOR SHALL FIELD VERIFY AND DOCUMENT ALL EXISTING ALL STRUCTURAL INTERFERENCE THAT WOULD AFFECT THE EXECUTION OF THE NEW DIMENSIONS, ELEVATIONS, BENCHMARKS, MATERIALS, UTILITIES AND CONSTRUCTION WORK. NO FLOOR OR STRUCTURAL MEMBERS SHALL BE CUT WITHOUT PERMISSION TYPE THAT MAY AFFECT OR BE AFFECTED BY NEW WORK, AND SHALL COORDINATE OF A REGISTERED STRUCTURAL ENGINEER. ALL PROPOSED SLEEVE I CORING SHALL SUCH FIELD VERIFICATION WITH THE CONTRACT DOCUMENTS AND THE EXECUTION BE REVIEWED BY THE ARCHITECT. OF THE WORK. THE CONTRACTOR SHALL NOTE ANY DISCREPANCIES AND /OR PROVIDE OPENING IN EXISTING PARTITION, SHOWN WITH DASHED LINES, AS CONFLICTS INVOLVING EXISTING CONDITIONS AND BRING THEM TO THE ARCHITECT'S REQUIRED TO INSTALL NEW HOLLOW METAL DOOR FRAME OR SORROWED LIGHT OF 5. THE CONTRACTOR SHALL REMOVE ALL EXISTING FLOOR FINISHES AND ADHESIVE ATTENTION IMMEDIATELY. THE TYPE AND STYLE INDICATED ON THE DOOR OR BORROWED LIGHT SCHEDULE. DOWN TO THE CONCRETE SLAB, AND LEAVE FLOOR SMOOTH FOR NEW FINISH. THE CONTRACTOR SHALL OBSERVE MANUFACTURER'S REQUIREMENTS FOR SUB -FLOOR 4. THE CONTRACTOR SHALL FIELD - VERIFY THE EXISTING CONDITIONS AS THEY PREPARATION. TREATMENT OF EXISTING FLOOR FINISHES WITHIN AREAS OF RELATE TO SPECIFIC PORTIONS OF THE WORK. VERIFICATION SHALL BE L DEMOLITION SHALL BE AS FOLLOWS: UNDERTAKEN IN ADVANCE TO ALLOW FOR THE TIMELY IDENTIFICATION OF EXISTING - - - -- - A. CARPET: REMOVE ENTIRELY, INCLUDING PADDING, REMOVE CONDITIONS THAT MAY AFFECT THE SCHEDULED INSTALLATION OF NEW WORK AS I 1E - - - - REMAINING GLUE RESIDUE AND PATCH AS NECESSARY FOR NEW DESIGNED AND DETAILED, AND TO AVOID UNDUE AND UNREASONABLE DELAYS TO 1 1 FLOOR FINISH. THE PROJECT SHOULD SUCH CONDITIONS BE DISCOVERED. TIMELY IDENTIFICATION L ,J B. VINYL: REMOVE ENTIRELY AFTER MATERIAL HAS SEEN TESTED FOR OF SUCH CONDITIONS SHALL PROVIDE FOR A MINIMUM PERIOD OF TEN (10) WORKING ASBESTOS, REMOVE GLUE OR GROUT RESIDUE. PATCH AS DAYS DURING WHICH TIME THE ARCHITECT WILL EVALUATE THE CONDITIONS AND REMOVE EXISTING CASEWORK, COUNTERS, SHELVING, EQUIPMENT AND SUPPORTS, NECESSARY TO PROVIDE LEVEL SURFACE. MAKE RECOMMENDATIONS FOR ACCOMMODATING NEW WORK. SHOWN WITH DASHED LINES. C. CERAMIC TILE: REMOVE ENTIRELY. PATCH AND REPAIR FLOORS WITH A LATEX LEVELING COMPOUND TO PRODUCE A SMOOTH, LEVEL 5. THE CONTRACTOR SHALL FIELD - VERIFY THE LOCATION AND EXTENT OF THE SURFACE TO RECEIVE NEW FINISHES. LIFE SAFETY SYSTEM (INCLUDING BUT NOT LIMITED TO SPRINKLER SYSTEMS, SMOKE DETECTION SYSTEMS, EMERGENCY LIGHTING SYSTEMS) AS THEY MAY BE AFFECTED 5. THE CONTRACTOR SHALL REMOVE EXISTING FINISHES, INCLUDING CERAMIC TILE, BY THE NEW WORK. THE CONTRACTOR IS RESPONSIBLE FOR ACCOMMODATING I VINYL WALL COVERING, WALL BASE ETC. AT ALL EXISTING WALLS TO RECEIVE NEW THESE SYSTEMS WHEN AFFECTED BY NEW WORK SO THAT ALL APPLICABLE CODES L I C. ' FINISHES, UNLESS NOTED OTHERWISE, AND LEAVE WALL SURFACE SMOOTH TO REQUIREMENTS ARE SATISFIED. RECEIVE NEW FINISHES. - ♦ 6. THE AREAS ADJACENT TO THE PROJECT ARE CURRENTLY OCCUPIED, AND 6. THE CONTRACTOR SHALL REMOVE ALL EXISTING CEILINGS TO ALLOW FOR MUST REMAIN COMPLETELY OPERATIONAL, THE CONTRACTOR SHALL COORDINATE PROPER INSTALLATION OF MECHANICAL, PLUMBING AND ELECTRICAL WORK, AND WITH BHSF FACILITIES AND CONSTRUCTION ANY CONSTRUCTION ACTIVITIES WHICH PATCH AND REPAIR EXISTING CEILINGS TO MATCH EXISTING. MAY IMPEDE THEIR NORMAL OPERATIONS, INCLUDING ANY ACTIVITY WHICH CREATES REMOVE EXISTING PLUMBING FIXTURES, SHOWN WITH DASHED LINES. EXISTING PIPING EXCESSIVE NOISE, AND NOTIFY ANY OCCUPANTS OF THE BUILDING OF ANY SHALL BE CAPPED AS INDICATED ON THE PLUMBING DRAWINGS. ANY FLOOR 7. WHERE NEW CEILINGS ARE INDICATED, THE CONTRACTOR SHALL REMOVE ALL CONSTRUCTION ACTIVITIES WHICH MAY AFFECT THEIR ABILITY TO OPERATE PENETRATIONS DUE TO THE REMOVAL OF PIPING ARE TO RE FILLED AS NOTED IN THE EXISTING CEILINGS TO ALLOW FOR PROPER INSTALLATION OF NEW CEILINGS. NORMALLY. CUTTING AND PATCHING GENERAL NOTES. 1. THE CONTRACTOR SHALL REFER TO MECHANICAL, PLUMBING, FIRE PROTECTION 7. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT. AND ELECTRICAL DOCUMENTS FOR REQUIRED DEMOLITION WORK AS WELL AS DAMAGE TO AREAS ADJACENT TO NEW CONSTRUCTION OR OCCUPIED AREAS EXISTING PIPING, CONDUITS, DUCTWORK, ETC. TO REMAIN WITHIN AREAS OF WHERE VARIOUS SYSTEM CONNECTIONS OR EXTENSIONS ARE REQUIRED AND go 40 M 40, IMP �-- ..... 41 DEMOLITION. SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY CONSTRUCTION ACTIVITIES. 1. THE CONTRACTOR SHALL IDENTIFY POINTS OF ACCESS TO THE BUILDING AND VERIFY MINIMUM CLEARANCES AVAILABLE FOR USE IN TRANSPORTING NECESSARY i CUTTING AND PATCHING GENERAL NOTES CONSTRUCTION MACHINERY, EQUIPMENT, MATERIALS, AND COMPONENTS INTO THE S BUILDING. USE OF SUCH POINTS OF ACCESS SHALL BE APPROVED BY THE OWNER. 1. WHERE EXISTING CONSTRUCTION TO REMAIN IS DAMAGED BY THE REMOVAL OF 9. THE CONTRACTOR SHALL IDENTIFY EXISTING COMPONENTS AND ASSEMBLIES 1 EXISTING CONSTRUCTION OR ANY OTHER WORK PREFORMED UNDER THIS WITHIN THE BUILDING THAT ARE CONSTRUCTED AS FIRE -RATED ASSEMBLIES; SHALL 5 CONTRACT. THE CONTRACTOR SHALL PATCH, REPAIR AND ALIGN ALL EXISTING NOTE ANY DISCREPANCIES AND /OR CONFLICTS INVOLVING EXISTING CONDITIONS CONSTRUCTION SO AS TO LEAVE NO EVIDENCE OF PATCHING OR REPAIR AND AND BRING THEM TO THE ARCHITECT'S ATTENTION IMMEDIATELY. PREPARE EXISTING SURFACE TO RECEIVE NEW SCHEDULED FINISHES. f 10. THE CONTRACTOR SHALL AT ALL TIMES MAINTAIN THE BUILDING IN A WEATHER S 2. WHERE EXISTING DUCTS, PIPES AND ELECTRICAL CONDUITS ARE LEFT EXPOSED TIGHT CONDITION. FROM DEMOLITION WORK IN FINISHED SPACES, THE CONTRACTOR SHALL ENCLOSE f THEM WITH A GYPSUM WALLBOARD PARTITION. 11. THE CONTRACTOR SHALL PROTECT ALL EXISTING AND NEW UTILITY LINES ON -C.7) OR ADJACENT TO THE SITE AND NOTIFY ALL UTILITY COMPANIES WHEN WORK IS 3. WHERE EXISTING EXTERIOR WALL OR INTERIOR PARTITIONS ARE DAMAGED IN BEING CARRIED OUT NEAR THEIR LINES. AREAS OF SELECTIVE DEMOLITION BY THE REMOVAL OF EXISTING CONSTRUCTION OR ANY OTHER DEMOLITION ACTION, THE CONTRACTOR SHALL REPAIR EXISTING WALL SURFACES TO MATCH EXISTING OR PRODUCE A SMOOTH SURFACE TO RECEIVE NEW FINISHES, 4. WHERE LEVEL CHANGES, HOLES, DEPRESSIONS, OR FORMED TRENCHES ARE UNCOVERED IN EXISTING CONCRETE SLAB BY THE REMOVAL OF EXISTING WALLS I DEMOLITION / CUTTING AND PATCHING EXISTING FLOORING HATCH AND REPAIR EXISTING CONCRETE DEMOLITION ACES WITH A LATEX CONTRACTOR PRTI SHALL KEYNOTES LEVELING COMPOUND UNLESS SPECIFIED OTHERWISE TO PRODUCE A SMOOTH - x LEVEL SURFACE TO RECEIVE NEW FINISHES. �--� 5. WHERE PIPES, CONDUITS, DUCTWORK, ETC. ARE TOME REMOVED FROM FLOOR AREA FOR WHICH SELECTIVE DEMOLITION IS REQUIRED. SEE EXISTING WALL I PARTITION TO REMAIN, THE CONTRACTOR SHALL INFILL THE SPECIFICATIONS SECTION 017329 1 024119 FOR ADDITIONAL INFORMATION. OPENING I PENETRATION WITH MATERIALS THAT MATCH THE EXISTING ALL CONSTRUCTION TO REMAIN WHICH IS AFFECTED BY DEMOLITION SHALL CONSTRUCTION, OR AN UL- APPROVED MATERIAL TO MAINTAIN THE EXISTING FIRE D2 BE PATCHED AND ALIGNED SO AS TO LEAVE NO EVIDENCE OF PATCHING OR RATED ASSEMBLY. REPAIR. 6. WHERE WALL AREAS THAT ARE LEFT EXPOSED AS A RESULT OF AN G DOOR AND FRAME AND PREPARE OPENING FOR ADJUSTMENT IN FINISH CEILING HEIGHT. THE CONTRACTOR SHALL REPAIR EXISTING D3 INSTALLATION REMOVE EXISTING NEW DOOR AND FRAME. WALL SURFACES TO MATCH EXISTING OR PRODUCE A SMOOTH SURFACE TO RECEIVE CORRIDOR NEW FINISHES. D4 REMOVE EXISTING WALL 7. WHERE PIPES, CONDUITS, DUCTWORK, ETC. ARE TO BE REMOVED FROM ANY FLOOR OR ROOF ASSEMBLY TO REMAIN, THE CONTRACTOR SHALL INFILL. THE D5 REMOVE EXISTING CEILINGS AS NECESSARY TO PERFORM NEW WORK. OPENING WITH MATERIALS TO MAINTAIN DESIGNATED FIRE OR SMOKE RATING, AS INDICATED BELOW: A. WHERE OPENINGS ARE ACCESSIBLE TO FOOT TRAFFIC, EXPOSED TO VIEW, OR ARE GREATER THAN 2 ", THE OPENING MUST BE FILLED WITH A - _--�D. 3) CONCRETE SYSTEM SIMILAR TO EXISTING. -� B. AREAS NOT EXPOSED TO VIEW, OR GREATER THAN 6 ", THE OPENING MUST BE FILLED WITH A CONCRETE SYSTEM SIMILAR TO EXISTING. C. AREAS NOT EXPOSED TO VIEW, CONCEALED BY CONSTRUCTION OR ' WHERE THE OPENING IS LESS THAN 6" THE OPENING MUST BE FILLED WITH A UL DESIGN SYSTEM AS SPECIFIED N DIVISION 7 "THROUGH PENETRATION RESISTIVE MATERIAL ". KEY PLAN H0 Ek IRIVA �'i �Ql Fc A R R A Y healthcare facilities solutions 6900 Broken Sound Boulevard NW Suite 125 Boca Raton, FL 33437 t: 561.995.1700 f: 561.955.1701 firm license number www.arrayhfs.com AA26000890 4M R { MARK D. TAUDIEN +" S. E AR0011821 CONSULTANTS: Smith Seckman Et Reid, Inc. i 1 600 West Hillsboro Blvd, Suite 300 1 Deerfield Reach, FL 33441 Phone: 954.421.1260 Fwx: 954.421.1466 OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: INTERIOR RENOVATIONS FOR CENTRAL MONITORING ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 AHCA: CLIENT CODE /FILE NUMBER: 231100154 PROJECT ID/SUBMISSION NUMBER: 187 -1 2 B Bid and Permit Set 0 07 -18 -12 1 A AHCA Stage Ill 1 107-03-12 NO. D DESCRIPTION D DATE CITY" OF SOUTH REVISIONSj15SUES Bli! DINIG DEPT. SHEET TITLE: < <E DEMOLITION PLAN - I':k SEVENTH FLOOR 0 DRAWN: EARS CHECKED: MDT CON /REF No. 00000 PROJECT No. 3606 DATE: 07-03-12 SCALE: As indicated MI AD - 171 This documeTA is c ccpp g'd protected instrument of property of PRHAY nd r. ., for s th titlerr lr 'etc , ''e ron ctiori r c Qf 5 ou � err t' :; wrMe pp r­ ss Gf : - ::= ill.,;al c , will be pre.,r-r.,_t:.d r cer :.,e low (DCOPYRIGHT - 2012 ARRAY HFS