Loading...
12-984-005C - 1.. V 2 3 d ARCHITECTURAL LIFE SAFETY PLAN SECOND FLOOR 5 , Y 4 Y►• Y U • • Y • • ► 4 •r• ••• • LIFE SAFETY F ;Mr,'LEGEND • •: ••' IAHCAStagelll , Y Y • , DESCRIPTION DATE REVISIONS /ISSUES FIRE DEPT 4TMEN r CONNECTION' • r Y Y • EMERGENCY POWER`iIGHT FIXTURE . (Z EXIT LIGHT FIXTURES WITH DIRECTIONAL CHEVRONS AS SHOWN ► EXIT LIGHT WITHOUT CHEVRON ■ MANUAL FIRE ALARM p FIRE EXTINGUISHER g FIRE EXTINGUISHER CABINET SMOKE DETECTOR Qo SMOKE/HEAT DETECTOR (j) HEAT DETECTOR HORN AND STROBE [�Q HORN AND STROBE SEPARATE X STROBE - -- -•- -- – --- -- – – – - NON RATED SMOKE PARTITION EXISTING NON RATED SMOKE PARTITION NEW — - — - — - — - 1 HOUR FIRE RATED BARRIER I PARTITION EXISTING 1 HOUR FIRE RATED BARRIER I PARTITION – - - -- - - - - -- 2 HOUR FIRE RATED BARRIER I PARTITION EXISTING 2 HOUR FIRE RATED BARRIER I PARTITION 1 HOUR FIRE RATED SMOKE BARRIER EXISTING 1 HOUR FIRE RATED SMOKE BARRIER NEW 2 HOUR FIRE RATED SMOKE BARRIER EXISTING 2 HOUR FIRE RATED SMOKE BARRIER NEW EXIT DISCHARGE * SMOKE COMPARTMENT EXIT 175' -0" MAX. TOTAL TRAVEL DISTANCE TO AN EXIT 0_200' -0" MAX.nn SMOKE COMPARTMENT TRAVEL DISTANCE (NFPA) NOTE: RATED PARTITIONS AND SMOKE BARRIERS SHOWN ON THE EGRESS PLAN ARE A COMBINATION OF NEW AND EXISTING CONSTRUCTION. LIFE SAFETY /ICRA KEYNOTES ALS1 CORRIDORSIAREAS WHERE WORK IS TO BE DONE ABOVE CEILING FOR LOW VOLTAGE CABLING BY "PHILIPS" IN ACCORDANCE WITH HOSPITAL PROVIDED I.C.R.A, AL52 VERTICAL PENETRATION THOURGH EXISTING 2 HOUR FIRE RATED FLOOR SLAB. PROVIDE (1) 4 INCH DIAMETER EMPTY CONDUIT AND FIRESTOP PER UL DESIGN NO. C -AJ -3281 LS3 2" DIAMETER (2) HOUR RATED FIRESTOP SYSTEM PER UL DESIGN NO. W -L -3335 LS4 ALL CORRIDOR WORK TO COMPLY WITH HOSPITAL LC.R.A. - CONSTRUCTION CLASS 8, HIGH RISK, TYPE II. NOTE: REFER TO PHILIPS INSTALLATION DRAWINGS FOR SPECIFIC DEVICE LOCATIONS AND CABLING REQUIREMENTS # ,I-f y OF SOUTH H i� 11- f3ti.p,�� ;: >rCT1p.r PLAN NORTH 4 A R R A Y healthcare facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Boca Raton, FL 33487 t: 561.995.1700 f: 561.995.1701 www.arrayhfs.com firm license number AA26000820 SEAL: "`_ –j�,,� i G MARK D. TAUDl1 N +,� ✓r f �. . AR0011821 ` CONSULTANTS:, Smith Seckman Et Reid, Inc. 600 West Hillsboro Blvd, Suite 300 Deerfield Beach, FL 33441 Phone: 954.421.1260 Fax: 954.421.1466 OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT INTERIOR RENOVATIONS FOR CENTRAL MONITORING ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 AHCA: CLIENT CODE /FILE NUMBER: 23/100154 PROJECT ID /SUBMISSION NUMBER: 197 -1 1 IAHCAStagelll 07 -03 -12 NO, DESCRIPTION DATE REVISIONS /ISSUES ■a ARCHITECTURAL LIFE SAFETY - SECOND FLOOR DRAWN: EAS CHECKED: MDT CON /REF No. 00000 PROJECT No. 3606 DATE: 07" -03 -12 SCALE: As indicated ALS- 121 A T s -'ca jm r.t is 0. c ,.tight pratecteo ,r rat of terice, property of ARRAY cr_ se in tF tJed Fr c1 r, I� prot -cfior. r Esc f this do(,u e E ,;",tar pe - :r� •f BRAY is iti ,..I crc will he presec4,ad ufder he Ic"'. lDCOPYRIGHT - 2012 ARRAY HFS