12-965-013
CAI 0 -v v C v C7 v 0 0 a M O cq N v 0 0 '.w U a� 0 N N v F� F-- ci 0 c a� n 2LSLD1 250 LIFE SAFETY BRANCH DRY TYPE TRANSFORMER SCHEDULE SIZE KVA PRIMARY SECONDARY 480 VOLT 208 VOLT EE NT OSEE 480V FEEDER 120/208V FEEDER GROUNDING NEW CONSTRUCTION AMPS AMPS OVERCURRENT S NOTE NOTE 1 SEE NOTE #2 SEE NOTE #2 SEE NOTE #3 T9 9 11 25 20A, 3P 30A, 3P 3#12 & 1 # 12G - 3/4 "C. 4#10 & 1#8G - 3/4 "C. 1#8 - 3/4 "C T15 15 18 42 30A, 3P 50A, 3P 3 #10 & 1#10G - 3/4 "C. 4 #8 & 1#8G - 1-C. 1#8 - 3/4 "C T30 30 36 83 60A, 3P 100A, 3P 3 #6 & 1#10G - 3/4 "C. 4 #3 & 1 #8G - 1 1/4 "C. 1#8 - 3/4 "C T45 45 54 125 80A, 3P 150A, 3P 3 #4 & 1 #8G - 1 "C. 4#1/0 & 1#6G - 2 "C. 1#6 - 3/4 "C T75 75 90 208 150A, 3P 250A, 3P 3#11/0 & 1#6G - 1 1/2 "C. 4 #250 KCMIL & 1#2G 1#2 - 3/4 "C 15 3 #3/0 & 1#6G. 2" 200 4 #3/0 & 1#6G. 2" 16 - 2 1 2 C. 3 #4/0 & 1 #4G. T112 112.5 135 313 200A, 3P 400A, 3P 3 #3/0 & 1#6G - 2 "C. 4#600 KCMIL & 1 #1 /OG 1#11/0 - 3/4 "C. T150 150 181 417 300A, 3P 500A, 3P 3 #350 KCMIL & 1#4G 8 #250 KCMIL & 2 #1 /OG 1#11/0 - 3/4 "C 22 23 3 #500 KCMIL & 1 #3G. 3 1/2- 350 4 #500 KCMIL & 1#3G. - 3"C. 2 -2 1/2 C. 25 T225 225 271 625 400A, 3P 800A, 3P 3 #600 KCMIL & 1#3G "C. 8 #600 KCMIL & 2 #3 /OG "C. 1 #3/0 - 3/4 "C 500 8 #250 KCMIL & 2 #2G. 2 -2 1/2 " 28 29 6 #350 KCMIL & 2 #1G. - 3 1/2 2 -4 8 #350 KCMIL & 2 #1G. T300 300 361 833 600A, 3P 1000A, 3P 6 #350 KCMIL & 2#1G 12 #400 KCMIL & 3 #3 /OG 1#3/0 - 3/4 "C 33 6 #600 KCMIL & 2 #1 /OG. 2 -3 1/2- 800 8 #600 KCMIL & 2 #1 /OG. 2 -4" 2-3"C. 3-3"C. 9 #400 KCMIL & 3 #2 /OG. T500 500 602 1389 900A, 3P 1600A, 3P 9 #350 KCMIL & 3 #2 /OG 16 #600 KCMIL & 4 #35OG 1 #350KCMIL -1 "C. 12 #600 KCMIL & 3 #3 /OG. 3 -4" 38 39 12 #600 KCMIL & 4 #4 /OG. 4 -3 1/2- 3-3"C. 4-4"C. 4 -4" TRANSFORMER NOTES: 1. SECONDARY OVERCURRENT PROTECTION SHALL BE LOCATED WITHIN TEN (10 ) FEET OF THE TRANSFORMER SECONDARY TERMINALS EITHER IN A PANELBOARD (MAIN BREAKER) OR A INDIVIDUALLY MOUNTED CIRCUIT BREAKER. 2. ALL CONDUCTOR SIZES ARE BASED ON N.E.C. TABLE 310 -16 FOR COPPER CONDUCTORS. 3. TRANSFORMER BONDING JUMPER AND GROUNDING ELECTRODE CONDUCTOR (COPPER CONDUCTORS). BOND THE NEUTRAL OF THE TRANSFORMER SECONDARY TO THE TRANSFORMER CASE, WITH BONDING JUMPER. GROUND THE CASE OF THE TRANSFORMER WITH THE GROUNDING ELECTRODE CONDUCTOR TO THE NEAREST AVAILABLE EFFECTIVELY GROUNDED STRUCTURAL METAL MEMBER OF THE STRUCTURE, OR THE NEAREST AVAILABLE EFFECTIVELY GROUNDED METAL WATER PIPE OR OTHER ELECTRODES AS SPECIFIED IN N.E.C. SECTIONS 250 -81 AND 250 -83 WHERE THE PRECEDING ELECTRODES ARE NOT AVAILABLE. 4. 600 KCMIL CONDUCTORS SHALL BE COORDINATED WITH PROPER TERMINATION LUGS OR PROVIDED WITH MAC ADAPTERS AS REQUIRED TO COORDINATE WITH STANDARD BREAKER LUG SIZES. 2CLD1 2 800 CRITICAL BRANCH ATS-E03 - 400A 3P 42K ISO BYPASS - - - -� r- - - - - -- -- - I 1LSL1 I I LIFE � I 100 I I SAFETY BRANCH ICLI ICLI 1 I 1150 CRITICAL CRITICAL BRANCH BRANCH I I IEQL2 i IEOLD2 EQUIP. BRANCH BRANCH 1 O 1 2 TO MSBI TO EDP 0 ATS -EO1 - 400A 3P 42K ISO BYPASS IEOLI IEOLDI � 1 150 � I 400 EQUIP. BRANCH BRANCH TO MSBI TO EDP ATS -CRI J ATS -LSI J 800A 3P 260A 3P 50K 42K ISO BYPASS ISO BYPASS TO MSBI 0 MSBI EDP 2500 ESSEN. BRANCH GEN FEEDER SCHEDULE BASED ON N.E.C. TABLE 310 -16 FOR COPPER CONDUCTORS FEEDER SYMBOL CONDUCTORS (3 PHASE, 3 WIRE) WITH GROUND RACEWAY SIZE CONDUIT NOMINAL AMPERE RATING CONDUCTORS (3 PHASE, 4 WIRE) WITH GROUND RACEWAY SIZE CONDUIT FEEDER SYMBOL Q NEW CONSTRUCTION 1 3 #8 & 1#10G. 3/4 " 50 4 #8 & 1#10G. in 2 3 3 #6 & 1 #10G. 3/4- 60 4 #6 & 1 #10G. 1" 4 5 3 #4 & 1#8G. in 70 4 #4 & 1#8G. 1 1/4 " 6 7 3 #3 & 1#8G. 1 1/4 " 100 4 #3 & 1#8G. 1 1/4 " 8 9 3 #1 & 1 #6G. 1 1/2 " 125 4 #1 & 1 #6G. 2" 10 11 3#11/0 & 1#6G. 1 1/2 " 150 4#11/0 & 1#6G. 2" 12 13 3 #2/0 & 1#6G. 2" 175 4 #2/0 & 1#6G. 2" 14 15 3 #3/0 & 1#6G. 2" 200 4 #3/0 & 1#6G. 2" 16 17 3 #4/0 & 1 #4G. 2" 225 4 #4/0 & 1 #4G. 2 1/2- 18 19 3 #250 KCMIL & 1#4G. 2 1/2- 250 4 #250 KCMIL & 1#4G. 2 1/2 " 20 21 3 #350 KCMIL & 1#4G. 3" 300 4 #350 KCMIL & 1#4G. 3" 22 23 3 #500 KCMIL & 1 #3G. 3 1/2- 350 4 #500 KCMIL & 1#3G. 3 1/2- 24 25 3 #600 KCMIL & 1 #3G. 3 1/2" 400 4 #600 KCMIL & 1#3G. 4" 26 27 6 #250 KCMIL & 2 #2G. 2 -2 1/2" 500 8 #250 KCMIL & 2 #2G. 2 -2 1/2 " 28 29 6 #350 KCMIL & 2 #1G. 2 -3" 600 8 #350 KCMIL & 2 #1G. 2 -3" 30 31 6 #500 KCMIL & 2 #1 /OG. 2 -3" 700 8 #500 KCMIL & 2 #1 /0G. 2 -3 1/2 " 32 33 6 #600 KCMIL & 2 #1 /OG. 2 -3 1/2- 800 8 #600 KCMIL & 2 #1 /OG. 2 -4" 34 35 9 #400 KCMIL & 3 #2 /OG. 3 -3" 1000 12 #400 KCMIL & 3 #2 /OG. 3 -3" 36 37 9 #600 KCMIL & 3 #3 /OG. 3 -3 1/2" 1200 12 #600 KCMIL & 3 #3 /OG. 3 -4" 38 39 12 #600 KCMIL & 4 #4 /OG. 4 -3 1/2- 1600 16 #600 KCMIL & 4 #4 /OG. 4 -4" 40 41 15 #600 KCMIL & 5 #250G. 5 -3 1/2- 2000 20 #600 KCMIL & 5 #250G. 5 -4" 42 43 q� 18 #600 KCMIL & 6 #350G. 6 -3 1/2 " 2500 24 #600 KCMIL & 6 #350G. 6 -4" 44 45 21#750 KCMIL & 7 #400G. 7 -4" 3000 28 #750 KCMIL & 7 #400G. 7 -5" 46 47 27 #750 KCMIL & 9 #500G. 9 -4" 4000 r36#750 KCMIL & 9 #500G. 9 -5" 48 NOTES: 1. 600 KCMIL AND 750 KCMIL FEEDERS SHALL BE COORDINATED WITH PROPER TERMINATION LUGS OR PROVIDED WITH MAC ADAPTERS AS REQUIRED TO COORDINATE WITH STANDARD BREAKER LUG SIZES. PNL 5NLD1 PNL 3NLD1 2NLD1 2 1800 TVSS NORMAL SYSTEM ED H-D 5:) Fc-',']',) M'.) ED M') FL-0-1') M') 0') 0&) TO ATS E01 TO ATS E02 TO ATS E03 600 KW NEMA 313 INL4 INL4 1NL3 1NLD1 INL1 INL2 750 KVA 2500A 1-1225 1 225 225 I 400 1 200 1 150 120/208V GENERATOR 3 PHASE QUICK NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL 4 WIRE CONNECT SYSTEM XSYSTEMX SYSTEM SYSTEM SYSTEM SYSTEM PARTIAL ELECTRICAL RISER DIAGAM KEYED NOTES: 01 EXISTING PANEL MODIFIED UNDER THIS PROJECT. PROVIDE NEW TYPED PANEL DIRECTORY. OPROVIDE "IOAWG INSULATED GROUNDING CONDUCTOR BETWEEN GROUND BUSES OF PANELS ICLI AND INL4 IN 1/¢ CONDUIT WITH GROUNDING BUSHINGS. OPROVIDE PULLBOX WITH POLARIS TAPS TO EXTEND EXISTING FEEDER FOR PANEL 1NL4 TO NEW LOCATION. REFER TO SHEET E1.1 FOR ADDITIONAL REQUIREMENTS. OEXISTING PANEL INL4 SHALL BE REPLACED AND RELOCATED. REFER TO FLOOR PLANS. CWP 3/0 CU BLDG. GROUND PER NEC -250 REFER TO SPECIFICATIONS ATS CRI ATS LS1 ATS E03 ATS E02 ATS EO1 0.) THIRD FLOOR 3000AF 3000AT SECOND FLOOR 3000 AMP BUS STAB FPL VAULT FIRST FLOOR CONSTRUCTION LEGEND SYMBOL DESCRIPTION Drawn: EXISTING TO REMAIN Revised: 0 -max EXISTING TO BE DEMOLISHED Q NEW CONSTRUCTION SRSmith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Certification - EB- 0000857 Dennis Davis PE - 58588 John E. Moulder PE - 33200 SSR JOB # 1232016.0 DC Q Z �w U W H 2 U 0 Y) °o occ M 't Co�ti �N 8 & N P6 i m � a, 220 'N mp-, � -,ox f�c 0 En - >v o 12 'a;.- 2-, a ca JAY cad °'U cc z :3 �: mQ 0 c E U- U. 7) O tl CO IT- Comm. No: 12007,00 Date: M Drawn: Revised: 0 T Q M LL O _I W _w LL I- g Z = W 1- U = O = O co Z W =i- wU 2 = J 0 � W ~ � _ O W M - v� Z Q� cm m co U Comm. No: 12007,00 Date: 05/22/12 Drawn: Revised: 0 05/08/13 8 .1� & :a •��FS < O R ONAt E�� -.% © 2011 HX NARV3b&, INC E5.1