Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-965-001
n v r U N C v M a� 0 a- 0 N oq tri v 0 0 a a� a� U) x a� v c t' v c a� l� ABBRE)IIATIONS Date: 05/22/12 Drawn: SYMBOLS LEGEND PROJECT GENERAL NOTES CODE CRITERIA DRAWING INDEX & L AND ANGLE H H.B. HOSE BIBB S S.A.B SOUND ATTENUATING Build. Dept. Comment COAL CONTRACT REQIlE1 MWI17S AFFECTING ALL TRADES CHAPTER EDITION I DESCRIPTION NO. DATE REVISION REV. # GENERAL - FLORIDA ADMINISTRATIVE CODE (FAC): 05/22/12 06/18/12 2 COVER SHEET ^ ® AT HBD. HARDBOARD BLANKET A IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND EACH OF HIS X1.1 05/22/12 03/19/13 7 ABBREVIATIONS, LEGENDS, NOTES, DRAWING INDEX � CENTERLINE H.C. HOLLOW CORE,HANDICAPPED S.C. SOLID CORE SUBCONTRACTORS TO REVIEW ALL DRAWINGS TO ASSURE COORDINATION OF 59A -3 FAC HOSPITAL LICENSURE 0 DIAMETER OR ROUND HDW. HARDWARE SCHED. SCHEDULE ALL WORK AFFECTING EACH TRADE. 69A -3 FAC FIRE PREVENTION - GENERAL PROVISIONS pIO, DATE REVISION - ARCFITECTURAL # NUMBER OR POUND HDWD. HARDWOOD S.A. SOAP DISPENSER 69A -53 FAC UNIFORM FIRE SAFETY STANDARDS FOR Al. 05/22/12 08/16/12 � ^ ^ LIFE SAFETY FIRST FLOOR PLAN ^ -_ -_ = A HGT. HEIGHT SEAL. SEALANT COLUMN AND 1 1. DIMENSIONS ON PLANS ARE TO COLUMN CENTERLINE, TO FINISH FACE OF HOSPITALS AND NURSING HOMES A3.0 05/22/12 _ ___ _ _- INFECTION CONTROL RISK ASSESSMENT A.B. ANCHOR BOLT H.M. HOLLOW METAL SECT. SECTION CONSTRUCTION GRID LINES INTERIOR METAL STUD PARTITIONS TO FACE OF CONCRETE OR MASONRY 69A -60 FAC 2010 THE FLORIDA FIRE PREVENTION CODE A4.1 05/22/12 06/01/12 t DEMOLITION FIRST FLOOR PLAN A/C CON HORIZ. HORIZONTAL S.F.,SQ.FT.SQUARE FOOT (FEET) AIR / CONDITION (ING) WALLS, TO FINISH FACE OF EXTERIOR STUD WALLS AND TO FACE OF 61C -5 FAC 2000 FLORIDA ELEVATOR SAFETY CODE A5.1 05/22/12 03/19/13 H.PT. HIGH POINT SH. SHELVING, SHELF SH. ACOUS. ACOUSTIC (AL) CORRIDOR SIDE FINISH OF CORRIDOR PARTITIONS UNLESS OTHERWISE 98 -72 FAC FLORIDA PRODUCT APPROVAL REQUIREMENTS AS NEW CONSTRUCTION FIRST FLOOR PLAN ADJ. ADJUSTABLE, ADJACENT HR. H.R. HOUR HANDRAIL SHT. SIM. SHEET SIMILAR O DOOR SYMBOL NOTED. REQUIRED BY FLORIDA STATUTE 553.842 DIMENSION FIRST FLOOR PLAN A6.1 05/22/12 03/19/13 7 A.D.O. AUTOMATIC DOOR OPENER H.R.S. HEALTH AND REHABILITATIVE S.M. SHEET METAL 2. ALL VERTICAL AND HORIZONTAL DUCTS, PIPES CONDUITS PANELS, ETC. FLORIDA BUILDING CODE (FBC): A7.1 05/22/12 03/19/13 EQUIPMENT FIRST FLOOR PLAN A.F.F. ABOVE FINISH FLOOR SERVICES S.M.S. SHEET METAL SCREW O ALUMINUM WINDOWS AND 3 STORE FRONTS (WHETHER SHOWN OR NOT IN FINISHED ROOMS NOT ENCASED IN ) FLORIDA BUILDING CODE FLORIDA FUEL GAS CODE 2010 2010 -- 7 - A8.1 05/22/12 03/19/13 REFLECTED CEILING FIRST FLOOR PLAN A.H.U. AIR HANDLER (UNIT) UNIT H.S. HEAT STRENGTHENED S.P.B. SPECIMEN PASS BOX FINISHED WALLS OR CEILINGS SHALL BE FURRED -IN AND FINISHED TO MATCH ADJACENT SURFACES. SUCH FURRED SPACES SHALL EXTEND THE FLORIDA MECHANICAL CODE2010 INTERIOR PARTITION DETAILS A13.1 a 05/22/12 06/01/12 AL. A.L. ALUMINUM ACOUSTICAL LAY -IN H.S.V. HEAT SEAMED VINYL SPEC. SPECIFICATION (S) EN EQUIPMENT NUMBER LENGTH OF THE WALL BETWEEN INTERSECTING WALLS UNLESS OTHERWISE FLORIDA PLUMBING CODE 2010 INTERIOR PARTITION DETAILS A13.1 b 05/22/12 _ _t ALT. ALTERNATE HTG. H.V.A.C. HEATING HEATING, VENTILATION, & SPF. S.S. SOUNDPROOF STAINLESS STEEL STEEL OR WOOD FRAME, INDICATED. WHERE FURRING A PORTION OF A WALL CONFLICTS WITH A13.5 05/22/12 06/18/12 2 INTERIOR PARTITION DETAILS ® SELF - PROTECTING STRUCTURE A14.1 05/22/12 06/18/12 DOOR SCHEDULE, DETAILS, AND LEGEND ANOD. ANODIZE(D) AIR CONDITIONING STA. STATION O VIEW WINDOW CASEWORK, THE FURRED LENGTH SHALL BE AS REQUIRED TO ALLOW FOR GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITAL AND 2 A.P. APPROX. ACCESS PANEL APPROXIMATE I STD. STANDARD O KEYNOTE SYMBOL PROPER INSTALLATION. WHERE ACCESS IS REQUIRED FOR VALVES, DAMPERS OTHER DEVICES REQUIRING ADJUSTMENT, PROVIDE ACCESS HEALTHCARE FACILITIES: 2010 EDITION A17.1 05/22/12 03/19/13 INTERIOR CASEWORK ELEVATIONS _ I.C.U. INTENSIVE CARE UNIT STL. STEEL IN PANELS PAINTED TO MATCH ADJACENT SURFACES. WHERE ENCLOSURE HANDICAP ACCESSIBILITY STANDARDS (UNDER AHCA SUBMISSION): A18.1 05/22/12 03/19/13 CASEWORK DETAILS ARCH. ARCHITECT I.D. INSIDE DIAMETER STOR. STORAGE CONSTITUTES PART OF A FIRE RATED ASSEMBLY PROVIDE LABELED ACCESS FLORIDA AMERICANS WITH DISABILITIES ACT: FINISH SCHEDULE, LEGEND, AND DETAILS / TOILET ACCESSORIES A19.1 05/22/12 09/19/12 0 AUTO. AUTOMATIC IN. INCH (ES) STRL. STRUCTURAL DOOR. SECTION 553.501- 553.513, F.S AND ACCESSIBILTY PLANS B' B.G. BUMPER GUARD INCL. INCLUDE (D) (ING) S.U. S.Y. SOILED UTILITY SUSPENDED �ASECTION LETTER 3. WHERE ELECTRICAL DEVICES ARE INDICATED IN A FIRE OR FIRE /SMOKE NO. DATE REVISION HVAC BLDG. BUILDING INSUL. INSULATION S.Y. SQUARE YARD CUTTING LINE WALL ON THE DRAWINGS, THE MAXIMUM ALLOWABLE AREA OF INDIVIDUAL HANDICAP ACCESSIBILITY STANDARDS (UNDER LOCAL AHJ SUBMISSION): BM. BEAM INT. INTERIOR A16.1 SHEET WHERE LOCATED U.L. LISTED BACKBOXES PERMITTED IN THE WALL IS 16 SQ.IN. WITH A 2012 FLORIDA ACCESSIBILTY CODE FOR BUILDING CONSTRUCTION M0.1 05/22/12 05/08/13 a MECHANICAL LEGEND, NOTES, AND DRAWING INDEX M0.2 05/22/12 05/08/13 a MECHANICAL SCHEDULES BOT. BOTTOM INV. INVERT (ED) T MAXIMUM AGGREGATE OF 100 SQ.IN. PER 100 SQUARE FEET OF WALL SECTION 553.503 F.S B.U.R. BUILT -UP ROOF I.P. ISOLATION PANEL T. TREAD, TOILET AREA. BACKBOXES ON OPPOSITE FACES OF SUCH WALLS SHALL BE M0.3 05 22/12 / 05/08/13 a MECHANICAL SPECIFICATIONS C I.P.S. INSIDE PIPE DIAMETER TA. T.B. TABLE TEST BORING A OFFSET A MINIMUM HORIZONTAL DISTANCE OF 24 IN. WHEN M1.0 05 22/12 05/08/13 a CONSTRUCTION ZONE VENTILATION PLAN - MECHANICAL CAB. CABINET I.T. I.V.T. ISOLATION TRANSFORMER INTRAVENOUS TRACK T.C. TOILET COMPARTMENT INTERIOR ELEVATION SYMBOL A15.1 PENETRATIONS EXCEED THE ALLOWABLE AREAS THE DEVICES SHALL BE AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI): M1.1 05/22/12 05/08/13 a FIRST FLOOR PLAN - DEMOLITION - MECHANICAL C.B. CATCH BASIN TEL. TELEPHONE SET IN A FURRED SPACE IN FRONT OF THE FIRE OR FIRE /SMOKE WALL AS DESCRIBED IN NOTE 2 ABOVE OR PROVIDED WITH A FIVE -SIDED ANSI -A 117.1 "AMERICAN NATIONAL STANDARD FOR BUILDINGS M1.2 05/22/12 06/21/12 , FIRST FLOOR PLAN - DEMOLITION - PIPING C.C.T. CUBICAL CURTAIN TRACK JAN. JANITOR TEMP. TEMPERED, TEMPERATURE ENCLOSURE AS DESCRIBED IN NOTE 4 BELOW. AND FACILITIES - PROVIDING ACCESSIBILITY AND M2.1 05/22/12 05/08/13 _ a FIRST FLOOR PLAN - NEW CONSTRUCTION - MECHANICAL C.C.U. CORONARY CARE UNIT JT. JOINT T. &G. TONGUE & GROOVE A A 4. ITEMS RECESSED IN CORRIDOR, SMOKE OR FIRE WALLS SUCH AS USABILITY FOR PHYSICALLY HANDICAPPED PEOPLE" M2.2 05/22/12 05/08/13 a FIRST FLOOR PLAN -NEW CONSTRUCTION - PIPING CER. C.F.C.I. CERAMIC CONTRACTOR FURNISHED K THK. T.P.D. THICK (NESS) TOILET PAPER DISPENSER A DETAIL INDICATION SYMBOL RECESSED TOILET ACCESSORIES, FIRE EXTINGUISHER AND /OR HOSE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME): M4.1 05/22/12 MECHANICAL DETAILS M4.2 05/22/12 05/08/13 MECHANICAL DETAILS CONTRACTOR INSTALLED K.P. KICK PLATE T.P.H. TOILET PAPER HOLDER CABINETS, MEDICAL GAS VALVE BOXES, NURSE CALL BACKBOXES, FIRE ASME- A17.1 -04 2004 SAFETY CODE FOR ELEVATORS AND ESCALATORS C.G. CORNER GUARD K.S. KNEE SPACE TREAT. TREATMENT ALARM SIGNAL BOXES, ELECTRICAL AND SIGNAL CABINETS, D OTHER BACKBOXES WHICH EXCEED 16 SQ. IN. SHALL BE INSTALLED IN A M5.1 05/22/12 05/08/13 a MECHANICAL CONTROLS C.I. C.J. CAST IRON CONTROL JOINT L L. LENGTH T.V. TYP. TELEVISION TYPICAL AREA /ITEM REVISION FIVE -SIDED ENCLOSURE CONSTRUCTED OF LAYERS OF 5/8" THICK TYPE X NATIONAL FIRE PROTECTION ASSOCIATION (NFPA): NO. DATE REVISION PLUMBM C.L. CENTER LINE LAB. LABORATORY REVISED GYPSUM WALLBOARD EQUAL IN NUMBER TO THAT REQUIRED FOR THE NFPA -10 2007 STD. FOR PORTABLE FIRE EXTINGUISHERS CLG. CEILING L.A. LAY -IN ACOUSTICAL U UC. UNDERCUT RATING OF THE WALL INSTALLED WITH APPROVED FASTENERS SCREWED TO � NFPA -13 2007 STD. FOR THE INSTALLATION OF SPRINKER SYSTEMS P0.1 05/22/12 05/08/13 a PLUMBING LEGEND AND DRAWING INDEX CLO. CLOSET LAM. LAMINATE U.C. UNDERCOUNTER STUDS AND HEADERS AND BACKSIDE OF ENCLOSURE LAMINATED TO REVERSE SIDE OF WALL WIDTH JOINT COMPOUND. WHERE DEPTH OF BOX NFPA -14 2007 STD. FOR INSTALLATION OF STANDPIPE AND P0.2 05/22/12 PLUMBING SCHEDULES C.M. C.M.U. CLEAR CONCRETE MASONRY UNIT LAV. LBL. LAVATORY LABEL U.O.N. UNLESS OTHERWISE NOTED 100' -0" FLOOR /DATUM ELEVATION EXCEEDS WALL THICKNESS, PROVIDE FRAMING AS REQUIRED TO HOSE SYSTEMS P0.3 05/22/12 PLUMBING SPECIFICATIONS pO.4 05/22/12 05/08/13 PLUMBING SPECIFICATIONS UTIL. UTILITY UTIL. COL. COLUMN FIRST FLOOR LEVEL ACCOMMODATE DEPTH AS DESCRIBED IN NOTE 2 ABOVE. NFPA -15 2007 STD. FOR WATER SPRAY FIXED SYSTEMS FOR FIRE COM. COMMON L.F. LKR. LINEAR FEET LOCKER V V. VINYL 5. WHERE DUCTS PIPES CONDUIT BAR JOISTS BEAMS OR ANY OTHER MATERIALS PENETRATE A FIRE RATED WALL OR PARTITION, OPENINGS NFPA -17 2009 PROTECTION STD. FOR DRY CHEMICAL EXTINGUISHING SYSTEMS PO.5 05/22/12 PLUMBING SPECIFICATIONS P1.2 05/22/12 FIRST FLOOR PLAN - DEMOLITION - MEDICAL GAS CONC. CONCRETE L.L. LEAD LINED,LIVE LOAD V.B. VINYL BASE p SHALL BE TIGHTLY SEALED. ANNULAR OPENINGS IN CMU WALLS SHALL NFPA -20 2007 STD. FOR INSTALLATION OF STATIONARY PUMPS P2.0 05/22/12 03/19/13 7 UNDERGROUND PLAN - NEW CONSTRUCTION - PLUMBING CONST. CONSTRUCTION L.P. LIGHTPROOF V.C.T. VINYL COMPOSITION MATCH LINE BE FILLED WITH GROUT. DO NOT COVER PENETRATIONS OF CMU WALLS FOR FIRE PROTECTIONS CONT. CONTR. CONTINUOUS CONTRACTOR LT.WT. LIGHT WEIGHT VERT. VERTICAL (LY) B WITH DRYWALL. PENETRATIONS IN METAL STUD PARTITIONS SHALL BE NFPA -22 2008 STD. FOR WATER TANKS FOR PRIVATE FIRE P2.1 05/22/12 05/08/13 - a FIRST FLOOR PLAN - NEW CONSTRUCTION - PLUMBING P2.2 05/22/12 FIRST FLOOR PLAN - NEW CONSTRUCTION - MEDICAL GAS M VEST. VESTIBULE CORR. CORRIDOR CONSTRUCTED WITH 25 GA. GALVANIZED RUNNER CHANNEL SILL AND PROTECTION C.O. CASED OPENING MAS. MASONRY V.I.F. VERIFY IN FIELD HEADER SECURED TO METAL STUDS WITH THE SPACE AROUND THE NFPA -25 2008 STD. FOR THE INSPECTION, TESTING, AND P4.1 05/22/12 03/19/13 PLUMBING RISER DIAGRAMS CP. CARPET MATL. MATERIAL V.W.C. VINYL WALL COVERING - - - - - - PERIMETER OF THE PENETRATING OBJECT PACKED TIGHTLY WITH MAINTENANCE OF WATER BASED FIRE PROTECTION P5.1 05/22/12 PLUMBING DETAILS C.S. CONCRETE SEALED MAX. MAXIMUM W - - LINE OF OVERHEAD WALL CABINET COMPRESSED MINERAL FIBER INSULATION. ALL PENETRATIONS IN SYSTEMS - Per 69A -3.012 - Quarter) Flow C.S.W. CAVITY SHAFT WALL M.B. MACHINE BOLT W. WITH GYPSUM WALLBOARD METAL STUD PARTITIONS SHALL BE SEALED WITH U.L. Tests Shall Be Required For Those Sy stems ISO, DATE REVISION FF E PROTECTION MECH. MECHANICAL C.T. CERAMIC TILE W.B. WALL BUMPER. C.C.T. CUBICLE CURTAIN TRACK APPROVED FIRESTOP SYSTEM. ANNULAR OPENINGS GREATER AND 1 2" / Supplied By A Municipal Water Supply) CTR. COUNTER, CENTER MED. MED. MEDICINE CABINET CAB. PREPMEDICAL PREPARATION W.C. WATER CLOSET, WALL SHALL BE SEALED WITH TIGHT FITTING BLOWOUT PATCH CONSTRUCTED NFPA -30 2008 NFPA -31 2006 FLAMMABLE AND COMBUTIBLE LIQUIDS CODE STD. FOR THE INSTALLATION OF OIL BURNING FPO.1 05/22/12 FIRE PROTECTION SCHEDULES, LEGENDS, AND DRAWING INDEX C.T.S. COMPUTED AXIAL MET. MTL.METAL COVERING I.V. I.V. TRACK WITH EQUIVALENT LAYERS OF FIRE RESISTIVE GYPSUM WALLBOARD EQUIPMENT FP0.2 05/22/12 FIRE PROTECTION SPECIFICATIONS TOMOGRAPHY SCANNER MFD. MANUFACTURED W/C WHEEL CHAIR COVERING THE OPENING WITH A MINIMUM OVERLAP OF 4 INCHES, BUTTERED WITH JOINT COMPOUND AND FASTENED WITH TYPE G LAMINATING NFPA -37 2006 INSTALLATION AND USE OF STATIONARY FP0.3 05/22/12 FIRE PROTECTION SPECIFICATIONS CTSK. C.T.W. COUNTER SUNK CERAMIC TILE WAINSCOAT MFR. MANUFACTURER WD. W.H WOOD WATER HEATER SCREWS. INSULATED PIPES SHALL BE SLEEVED WITH FOAMGLASS CUMBUSTION ENGINES AND GAS TURBINES FP1.1 05/22/12 FIRST FLOOR PLAN - DEMOLITION - FIRE PROTECTION C.U. CLEAN UTILITY M.G. MEDICAL GAS W.I. WROUGHT IRON INSULATION. ANNULAR OPENING BETWEEN SLEEVE AND PIPE SHALL BE NFPA -45 2004 STD. ON FIRE PROTECTION FOR LABORATORIES FP2.1 05/22/12 03/19/13 FIRST FLOOR PLAN -NEW CONSTRUCTION -FIRE PROTECTION D M.G.A. M.G.O. MEDICAL GAS ALARM MEDICAL GAS OUTLET W/0 WITHOUT SEALED WITH APPROVED FIRE AND SMOKE RETARDANT SEALER. SLEEVES NFPA -54 2009 USING CHEMICALS NATIONAL FUEL GAS CODE FIRE PROTECTION DETAILS FP5.1 05/22/12 -� D.A. DELAYED ACTION M.G.V.B. MEDICAL GAS VALVE BOX W.O. WHERE OCCURS SHALL EXTEND A MAXIMUM OF 2" BEYOND FACES OF WALL. REFER TO PARTITION DETAILS AND MECHANICAL DRAWINGS. NFPA -70 2008 NATIONAL ELECTRICAL CODE (EXCLUDING ART. 80) NO. DATE REVISION ELECTRICAL DBL. DOUBLE M.H. MANHOLE W.P. WATERPROOF ING ( ) 6. WHERE A FIRE DAMPER IS REQUIRED THE SPACE BETWEEN THE SLEEVE NFPA -72 2007 STD. FOR INSTALLATION, MAINTENANCE, AND USE D.E. DEPT. DOUBLE EGRESS DEPARTMENT MIN. MISC. MINIMUM MISCELLANEOUS W.R. WT. WASTE RECEPTACLE. WEIGHT AND THE STUDS AND HEADERS SHALL BE OF THE PROPER CLEARANCE OF LOCAL PROTECTIVE SIGNALING SYSTEMS E0.1 05/22/12 06/18/12 - 2 ELECTRICAL SCHEDULES, LEGENDS, AND DRAWING INDEX DET. DETAIL MLDG. MOULDING W.W.F. WELDED WIRE FABRIC FOR THE SIZE OF THE DUCT IN ACCORDANCE WITH SMACNA NFPA -80 2007 NFPA -82 2004 STD. FOR FIRE DOORS AND WINDOWS STD. ON INCINERATORS, WASTE & LINEN E1.1 05/22/12 FIRST FLOOR PLAN - DEMOLITION - ELECTRICAL D.F. DRINKING FOUNTAIN M.O. MASONRY OPENING W.W.M. WELDED WIRE MESH MATERIAL LEGEND REQUIREMENTS. FIRE DAMPER SLEEVES SHALL BE INSTALLED AND SECURED IN ACCORDANCE HANDLING SYSTEMS AND EQUIPMENT E2.1 05/22/12 03/19/13 7 FIRST FLOOR PLAN - NEW CONSTRUCTION - LIGHTING DIA. DIAMETER M.O.L. MORE OR LESS Y WITH SMACNA STANDARDS. FIRE DAMPERS SHALL BE INSTALLED IN THE PLANE OF THE RATED ASSEMBLY. NFPA -88A 2007 STD. FOR PARKING STRUCTURES _ a E3.1 05/22/12 05/08/13 FIRST FLOOR PLAN - NEW CONSTRUCTION - POWER DIAG. DIM. DIAGONAL DIMENSION M.P. M.R. MEDICINE PREPARATION MOISTURE RESISTANT YD. YARD 7. LOW VOLTAGE WIRING WHICH PENETRATES A SMOKE OR FIRE /SMOKE WALL NFPA -90A 2009 STD. FOR THE INSTALLATION AIR CONDITIONING & E4.1 05/22/12 05/08/13 a FIRST FLOOR PLAN - NEW CONSTRUCTION - SYSTEM DISP. DISPENSER M.R.I. MAGNETIC RESONANCE - IIII VIII �IIII�II EARTH FILL SHALL BE SLEEVED WITH CONDUIT EXTENDING NOT MORE THAN 2 INCHES NFPA -90B 2009 VENTILATION SYSTEMS STD. FOR THE INSTALLATION OF WARM AIR E5.1 05/22/12 05/08/13 a PARTIAL ELECTRICAL RISER DIAGRAM E6.1 05/22/12 05/08/13 a PANEL SCHEDULES r•-- DN. DOWN IMAGER Illlllll= 11111 = 111111111= EITHER SIDE OF THE WALL AND SECURELY ANCHORED TO PREVENT SLIPPING THROUGH THE HEATING & VENTILATION SYSTEMS D.R. DR. DRESSING ROOM DOOR, DOCTOR M.S. M.S.L. METAL STUD MEAN SEA LEVEL WALL OR DAMAGING THE DRYWALL. REMAINING OPENINGS IN THE CONDUIT SLEEVE SHALL BE FILLED WITH TIGHTLY NFPA -91 2004 STD. FOR EXHAUST SYSTEMS FOR AIR CONVEYING E6.2 05/22/12 . ELECTRICAL STUDIES 1*:• �/ BRICK COMPRESSED MINERAL FIBER SAFING INSULATION AND SEALED WITH OF VAPORS, GASES, MISTS, AND E7.1 05/22/12 ELECTRICAL SPECIFICATIONS �! ?+ t�5 DWGS. DWR. DRAWINGS DRAWER M.T. MTD. METAL THRESHOLD MOUNTED ACOUSTICAL SEALANT. IT IS THE RESPONSIBILITY OF EACH TRADE NFPA -92A 2009 NON- COMBUSTIBLE PARTICULATE SOLIDS STANDARD FOR SMOKE- CONTROL SYSTEMS E7.2 05/22/12 ELECTRICAL SPECIFICATIONS �. E MUL. MULLION CONTRACTOR TO ASSURE COORDINATION OF INSTALLATION OF SUCH rr, WY -� ='. - EA. EACH M.V. MIXING VALVE CONCRETE SYSTEMS BETWEEN VENDORS AND SUBCONTRACTORS. THE CONTRACTOR UTILIZING BARRIERS AND PRESSURE DIFFERENCES - SHALL ASSURE THAT PENETRATIONS FOR UTILITIES ARE MADE WITH THE NFPA -92B 2009 STANDARD FOR SMOKE MANAGEMENT SYSTEMS IN - -:: E.B. E.J. EXPANSION BOLT EXPANSION JOINT N N.C. NURSE CALL STUCCO, CEMENT PLASTER, UTMOST CARE AND MINIMUM OF DAMAGE TO THE INTEGRITY OF ALL NFPA -96 2008 MALLS, ATRIA, AND LARGE SPACES STD. FOR VENTILATION CONTROL AND FIRE EL. ELEVATION N.I.C. NOT IN CONTRACT LIGHTWEIGHT CONCRETE PARTITIONS AND WALLS. SLEEVES AND CONDUIT SHALL BE INSTALLED PROVENTION OF COMMERCIAL COOKING OPERATIONS ELEC. ELECTRICAL NO. NUMBER PRIOR TO RUNNING CABLES. 8. FURNISH ACCESS PANELS IN WALLS AND NON- ACCESSIBLE CEILINGS (Subdivision 7 -2.2 of NFPA 96 applies ELEV. E.P. ELEVATOR EMERGENCY NOM. N.STA. NOMINAL NURSE STATION CMU - LARGE SCALE WHERE SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING OR prospectively only) E.P. ELECTRICAL PANELBOARD N.T.S. NOT TO SCALE ELECTRICAL EQUIPMENT IS REQUIRED, AND AT INTERVALS NOT TO EXCEED NFPA -99 2005 STD. FOR HEALTH CARE FACILITIES NARRATIVE PROJECT AREA IS 2,890 SQ. Fr. EQ. EQUAL 30 FEET IN NON- ACCESSIBLE CEILINGS OR FIRE MEMBRANES ADJACENT NFPA -1 2009 UNIFORM FIRE CODE (Florida Edition) EQUIP. EQUIPMENT O CMU -SMALL SCALE TO FIRE AND FIRE/SMOKE WALLS. WHERE ACCESS PANELS OCCUR IN NFPA -101 2009 LIFE SAFETY CODE Edition (Florida ( ) E.R. EMERGENCY ROOM, O.A. OVERALL RATED ASSEMBLIES THEY SHALL BEAR A LABEL RATING EQUAL TO THAT OF NFPA -101A 2007 GUIDE ON ALT. APPROACHES TO LIFE SAFETY THE SCOPE OF WORK INCLUDES 5 EXAM ROOMS, 1 TWO -BAY INFUSION ROOM, 1 SCREENING ROOM, AND EMERGENCY RELEASE O.C. O.D. ON CENTER OUTSIDE DIAMETER,OVERALL �/ / / CERAMIC TILE THE ASSEMBLY. ACCESS PANELS IN GYPSUM WALLBOARD MEMBRANES NFPA -105 2007 RECOMMENDED PRACTICE FOR INSTALLATION OF ASSOCIATED SUPPORT SPACES. ALSO INCLUDED ARE A REGISTRATION AREA, OFFICES, AND A STAFF LOUNGE. E.S. EXPOSED STRUCTURE ABOVE NON- ACCESSIBLE CEILINGS SHALL BE ALIGNED TO PERMIT ACCESS SMOKE- CONTROL DOOR ASSEMBLIES E.T. ELAPSED TIME DIMENSION AND SHALL BE SIZED TO PERMIT POSITIONING OF A STEP LADDER NFPA -110 2005 STD. FOR EMERGENCY AND STANDBY POWER DEMOLITION WILL BE LIMITED TO THE SPACES DENOTED IN THE PROJECT LIMITS AND WILL BE INCLUDED IN THE E.W.C. ELECTRIC WATER COOLER O.F.C.I. OWNER FURNISHED CONTRACTOR INSTALLED � - -METAL - LARGE SCALE THROUGH THE ACCESS PANEL IN THE CEILING. RATED ACCESS PANELS IN SYSTEMS SCOPE OF THIS PROJECT. EXP. EXPANSION CEILINGS AND MEMBRANES SHALL BE SUPPORTED FROM THE STRUCTURE, NFPA -251 2006 STD. METHODS OF TEST OF FIRE ENDURANCE ON EXIST. EXISTING O.F.0.1. OWNER FURNISHED OWNER NOT THE CEILING FRAMING. BUILDING CONSTRUCTION AND MATERIALS REMOVAL OF ALL EQUIPMENT, FURNITURE AND GENERAL STORAGE WILL BE HANDLED BY OWNER PRIOR TO THE START EXT. EXTERIOR INSTALLED METAL - SMALL SCALE OR 9. COORDINATE INSTALLATION OF PLUMBING, VENT STACKS AND CONDUIT TO NFPA -252 2006 STD. METHODS OF FIRE TESTS OF DOOR OF THIS PROJECT. F O.H. OVERHEAD, OPPOSITE SHEET METAL PERMIT INSTALLATION OF RECESSED TOILET ACCESSORIES, FIRE ASSEMBLIES 0. H. CAB. OVERHEAD CABINET EXTINGUISHER CABINETS AND OTHER RECESSED EQUIPMENT. WHERE SUCH NFPA -253 2006 STD. METHODS OF TEST FOR CRITICAL FLUX CONSTRUCTION OF THIS PROJECT WILL BE EXECUTED IN ONE PHASE. F.A. F.A.C. FIRE ALARM FIRE ALARM CABINET OPNG. OPP. OPENING OPPOSITE i -�J FINISH WOOD ITEMS ARE RECESSED IN CORRIDOR, SMOKE OR FIRE /SMOKE WALLS THEY OF FLOOR COVERING SYSTEMS USING RADIANT HEAT ENERGY SOURCE CONTRACTOR TO COORDINATE ALL SYSTEM WITH OWNER PRIOR TO START OF CONSTRUCTION INCLUDING UTILITIES F.A.P. FIRE ALARM PULL STATION O.S. OVERFLOW SCUPPER - SHALL BE INSTALLED IN A FIVE -SIDE ENCLOSURE AS DESCRIBED IN NOTE 4 ABOVE. NFPA -255 2006 STD. METHODS OF TEST OF SURFACE BURNING SHUT DOWN, HOURS OF OPERATION AND CONSTRUCTION SCHEDULING, ADJACENT DEPARTMENTS USES AND F.C. FURRING CHANNEL O.R. OPERATING ROOM 10. ALL WOOD BLOCKING WITHIN THE BUILDING ENVELOPE SHALL BE FIRE CHARACTERISTICS OF BUILDING MATERIALS CONSTRUCTION LOGISTICS. F.D. FIELD FLOOR DRAIN, DIMENSION P WOOD BLOCKING RETARDANT TREATED. ISOLATE SALT TREATED WOOD FROM METAL FRAMING NFPA -256 2003 STD. METHODS OF FIRE TESTS OF ROOF FDN. FOUNDATION P. PF. PAINT PREFABRICATED WITH 15# FELT AND USE CORROSION RESISTANT FASTENERS TO MINIMIZE NFPA -257 2007 COVERINGS STD. ON FIRE TESTS FOR WINDOW AND GLASS LOCATION MAP F.E. FIRE EXTINGUISHER WOOD SHIM GALVANIC CORROSION. F.E.C. FIRE EXTINGUISHER CABINET PL. PLATE PLASTIC 11. LAVATORIES AND SINKS SHALL BE INSTALLED A MINIMUM OF 4" FROM BLOCK ASSEMBLIES _ _ _ _ -� - - 11 �' ", �(1� "�L_!�.'. -- ; I r I 11 -� __ I�I_ . -_ - - -' �I - ( - -JI I '�' LAMINATE F.F.E. FINISHED FLOOR ELEVATION PLAS. PLASTER - SIDE OF WALL. FAUCETS SHALL BE INSTALLED WITH A MINIMUM OF 5" NFPA -703 2009 STD. FOR FIRE RETARDANT IMPREGNATED WOOD AND FIRE RETARDANT COATINGS FOR BUILDING F.H.C. FIRE HOSE CABINET PLBG. PLUMBING �- PLYWOOD FROM THE OUTLET TO THE FLOOD RIM OF SINKS, INCLUDING THOSE MATERIALS --_ -_ _ - �t �C rl✓- " , I J� Ill[ 1 I `- IF J�- c ,7 �(- ILII� �- r � -''�f i_)= F.I. FILM ILLUMINATOR PLYWD. PLYWOOD EQUIPPED WITH VACUUM BREAKERS. TOILETS SHALL BE SET 18" FOR NFPA -780 2011 INSTALLATION OF LIGHTNING SYSTEMS _II�� _ `'' -,� i ��l nJ -', -'� JLr +�Jl �r(- Jtln� t ,yylz 'st T - j ,( Q,r 988 __• FIN. FL. FINISH FLOOR POL. POLISHED - GYPSUM WALLBOARD HANDICAPPED FROM CENTERLINE TO FACE OF WALL OR LAVATORY. SINKS, COORDINATE INSTALLATION OF SINKS PLUMBING AND ELECTRICAL ITEMS IN NFPA -1963 2003 STD. FOR FIRE HOSE CONNECTIONS .� 1- - - -- - -._r T.. -. 72nd St - -_ _ 988 _Sirtmselor 988 e , ,- ,� _j1_t;�` 1 r Comers- L `.. 5, - - PR. PAIR ll `- r�(_Sunset Park O • - r ', - FLASH. FLUOR. FLUOR. FLASHING FLUORESCENT PT. POINT AND ADJACENT TO CASEWORK. PROVIDE AT LEAST 24" CLEARANCE FOR ACCESS TO FOOT PEDAL SHEET METAL & AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION INC. SMACNA I;;� (ir� �_=� ;moo �] �1 I ! - ' 1i( rt --,' r F! ?� U 1`'I `•,,I• � �'-_ -: -=-'- -' -,�; �`; i` �J F.N.D. FEMININE NAPKIN DISPOSAL P.T. PRESSURE TREATED RIGID INSULATION VALVES AT CLINICAL SINKS. 12. THE TRADE CONTRACTOR SHALL VERIFY CONSTRUCTION IS COMPLETE AND (SMACNA): 2003 . FIRE, SMOKE AND RADIATION DAMPER GUIDE ,- _ - r l [; l ` �.; i l (� -' � �:.., _� I r- = c-- !: 1- I ' 973 •`-I r - -A - J ' I F.N.V. FEMININE NAPKIN VENDOR P.T.D. PAPER TOWEL IN ACCORDANCE WITH THE CONTRACT DOCUMENTS PRIOR TO INSPECTION �, r; r- I�1( a� 1, ;� r,�i'�. ,_ �i =?.' / :'_ _ -�1 �- -- �I E�cpy_ 878 FPRF. FIRE PROOFING) PTN. DISPENSER PARTITION BY THE AUTHORITY HAVING JURISDICTION NATIONAL COUNCIL ON RADIATION PROTECTION &MEASUREMENTS (NCRP): ;-_ i ...�(�, , �c;l ; �� ,1 a �r Snapper Creek 82s _ _ _L -- Sna e��} `� :��, �, r :�. ,° F.R. FIRE RATED P.V.C. POLYVINYL CHLORIDE BATT INSULATION 13. IT IS THE INTENT OF THESE DRAWINGS TO PROVIDE SUBSTANTIAL, FIRE REPORT # 34 - MEDICAL X -RAY AND GAMMA RAY PROTECTION FOR .- ��I -. crF kPa,k- c FR. FT. FRAME FOOT OR FEET RESISTIVE INSTALLATIONS CONFORMING TO REQUIREMENTS OF THE ENERGIES UP TO 10 MEV. u:� FTG. FOOTING Q.T. QUARRY TILE SAFING INSULATION INDICATED FIRE TEST AND RECOMMENDATIONS OF UNDERWRITER'S LABORATORIES, THE GYPSUM ASSOCIATION AND WALLBOARD MANUFACTURER. AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS INC. (ASHRAE): n �_L _ ;;��a �Illnn_ �` �_ K -La ^,d Pare ' r= 1L';, J 'i� -- ;i y r FURR. FURRING R INSTALLATIONS NOT CONFORMING TO THOSE , L f ] (_ =� ` - r N Kendall Dr 94 ) FUT. FUTURE R. RISER OR RADIUS STANDARDS SHALL BE 2008 ASHRAE HANDBOOK OF FUNDAMENTALS _ . 874 - SN! 88:. l - 94 N Kendae Dr Q -..- - J� -J� [. =�iJ O F.W. FLUSH WOOD R.C. R.C.P. RUNNER CHANNEL REINFORCED CONCRETE -- CARPET CORRECTED AT NO ADDITIONAL COST TO THE OWNER. UNDERWRITERS LABORATORIES INC. UL • ( )• _ r7 c- " u 1 r-� - t ' I`�- i l ' /Chem ?L " �' I. I y BapUSt HaspRal iGre`e PJr� [ J R.D. PIPE ROOF DRAIN 2005 FIRE RESISTANCE DIRECTORY �; I] ct M,arnl ', �?' I �.,: , `' \J GA. GAL. GAUGE RE. RELATIVE TO PREMOLDED JOINT FILLER SHEET NO. SYSTEM GYPSUM ASSOCIATION (GA): Kenda'et J � i , •- _ ' ; Park'i I I _ - _--- GALV. GALLON GALVANIZED RECEP. REF. RECEPTACLE REFERENCE 2003 FIRE RESISTANCE DESIGN MANUAL, 17th. EDITION _ _ � 973 I, ,�I tj// . - - ( if - is I 1 =l y �-� tJ iJ _7 L I L� i �zr� l,' w'. - G.B. GRAB BAR REFR. REFRIGERATOR G.C. GENERAL CONTRACTOR - JOINT SEALANT AND BACKER ROD : -- _ .. r- - ���! i -_� �- l� G.M. GALVANIZED METAL REG. REGLET, REGULAR DISCIPLINE -f- AREA OF BUILDING • A51B L ��(� _ ` " D= -- I - -- - ;L -J C-- = =='` - -` �'�� '�;'�l1 G.M.L. G.M.S. GALVANIZED METAL LATH GALVANIZED METAL STUD REINF. READ. REINFORCING REQUIRED n--� -" I �-- �__- --��, �� a = __ Killian Giucns Z, / I i 1 I� 1��`(- ,f 1- REV- REVISION ra �� _''' sw - <, cr V "'I` 1 sw GND. GR. GROUND GRADE R.H. ROBE HOOK CATEGORY FLOOR OF BUILDING lJ' �I� _r, �olimst - =�` - M, At om Dr` _ SW 104th St�� - tJ • �� -- a - 1 �t ,--' NORTH GYP. GWB GYPSUM GYPSUM WALLBOARD RM. R.O. ROOM ROUGH OPENING �"_�, „ ( _ i Lake- I� 73 _ t- ll rGreen -Mar _` `� Ga'I�vay; r I' Ll r ; Q� I J : l 7\ _ - Acres :. i i ; a. : -'. c�� ' i� -, - -- i�� -1(-' 45 (� 7 _ _ ; 1 N� I I ' `� ;I st SW 112th I i ^ I r act�r1F� �d L ° ' r° v ) �►�CDN M�tD Tt; rnr`M_°O° 8 a) Ic p 0 Co df` - Na) co Ln -0v C 0 00 O td JAY co a U M= c EQ ca 1iLL �0ainI• Q Oa: a! .J W LL.Z =w 021 U J3:�g cc LLJ Q � °o Z IM CO m8 Comm. No: 12007.00 Date: 05/22/12 Drawn: Revised: A06/01/12 Addendum 1 Addendum ,L Addendum 2 A 3 06/21/12 Build. Dept. Comment 08/16/12 A09/19/12 A6 A03/19/13 03/08/13 A805/08/13 TO TH sE� 1 MY, E. 'nil: PLAN p� Sp LCfF1CA ON 3 COMPLY WITH THE ` I }I• bul c ES:. _ E E NDO R'0�� 3 © 2011 HARVARD'JOLL'Y, i X1.1 ..y kY• 1 r I