Loading...
12-965-052-10 9, cu 0 OL N O N 0 N R ai O 0 0 I c0 w U a� w 0 c0 O N r7 N N a N v F- ai v c w LZ NEW PANEL TO REPLACE EXISTING PANED INL4 OC DEVICE TYPEe Breaker ENCLOSURES NEMA 1 MAINSCA)i NLO CONTINUOUSCA)i 225 LOCATION, DEVICE FAMILYi Bolt On MOUNTING, Surface WIRINGi 3 -Phase 4 -More BUS SC RATING(A) 10000 FED FROMs PNL 1NLD1 VOLTAGE, 208/120 FAULT CURRENTCA) 5069 FED BY MA BKR CKT DESCRIPTION NOTES DEMAND VA OC PHASE OC VA DEMAND NOTES DESCRIPTION CKT KVA AMPS KVA CODE P F AMPS P 2 AMPS P ALL CODE N/A 1.00 1 HEART RHYTHM SW 6.9 CONTINUOUS L 832 20 1 A 20 1 1000 RECEPTACLES 44.3 LOUNGE 134 - MWAVE 2 3 HEART RHYTHM NE 100.00 UNITY CONTINUOUS L 576 20 1 B 20 1 180 RECEPTACLES 100.00 UNITY LOUNGE 134 CATER 4 5 HEART RHYTHM REGIST 1.00 CONTINUOUS L 706 20 1 C 20 1 720 RECEPTACLES A. MULTILEVEL DEMAND AND DESIGN FACTORS APPLIED AT EACH LOUNGE 134 6 7 EXAM 139 /EXAM 141 POWER FACTOR. RECEPTACLES 1080 20 1 A 20 1 900 RECEPTACLES RECEPTACLE OFFICE 140 8 9 CLEAN STORAGE USED TO CALCULATE RECEPTACLES 180 20 1 B 20 1 900 RECEPTACLES OFFICE 138 10 11 INTAKE 145/OFFC 149 NOTE 1 RECEPTACLES 1080 20 1 C 20 1 720 RECEPTACLES SCREENING 136 12 13 PASSAGE/WAIT 137 NOTE 1 RECEPTACLES 900 20 1 A 20 1 720 RECEPTACLES INFUSION 142 14 15 SOIL 133 /STORAGE 135 NOTE 2 RECEPTACLES 900 20 1 B 20 1 900 RECEPTACLES INFSN 142 /EXAM 146 16 17 SCREEN 136 - TRDMLL GENERAL EQUI 1460 20 2 C 20 1 1080 RECEPTACLES EXAM 147/EXAM 148 18 19 to SPARE - of A 20 1 720 RECEPTACLES NOTES 162 REGISTRATION 150 20 21 SPARE SPARE 0 20 1 B 20 1 720 RECEPTACLES NOTES 162 REG/CHART 150 22 23 SPARE SPARE 0 20 1 C 20 1 180 RECEPTACLES NOTES 162 CHART 150A 24 25 SPARE SPARE 0 20 1 A 20 1 0 SPARE NOTES 162 SPARE 26 27 SPARE NOTE 1 SPARE 0 20 1 B 20 1 0 SPARE NOTES 162 SPARE 28 29 SPARE NOTE 1 SPARE 0 20 1 C 20 1 0 SPARE NOTES 162 SPARE 30 31 SPARE SPARE 0 20 1 A 20 1 0 SPARE NOTES 162 SPARE 32 33 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 34 35 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 36 37 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 38 39 SPARE NOTE 2 SPARE 0 20 1 B 20 1 0 SPARE SPARE 40 41 SPARE SPARE 0 20 1 C 20 1 0 SPARE I SPARE 42 ALL CONNECTED KVA MAX PH AMPS a PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 16. 45 57.3 a A -N 6882.0 57.3 CONNECTED 16. 45 TOTAL DEMAND S. 73 30.7 a B -N 4356.0 36.3 DEMAND 8. 73 TOTAL DESIGN 9.25 32.5 a C -N 5216.0 43.4 DESIGN 9.25 DEMAND CALCULATION: LOCATIONS DEVICE FAMILY# Bolt On MOUNTINGS Flush WIRINGS 3 -Phase 4 -Wire BUS SC RATING(A) 10000 FED FROMs PNL INLDI VOLTAGEe 208 /120 FAULT CURRENT(A)i 7566 EXISTING PANEL FED BY 150A BKR CKT DESCRIPTION NOTES -------------------------------------------------------- ITEM DESCRIPTION - CONNECTED MAX PH ■ DEMAND --------------------- MAX PH - DESIGN MAX PH - ----- - X NOTES KVA AMPS KVA AMPS KVA AMPS P F ----------------------------------------------------------------------------------- END USE LOADS 2 AMPS P ALL CODE N/A 1.00 CONTINUOUS LIGHT 2.1 6.9 2.1 6.9 2.6 8.7 100.00 UNITY RECEPTACLES 12.9 44.3 5.2 17.7 5.2 17.7 100.00 UNITY GENERAL EQUI PMEN 1.5 6.1 1.5 6.1 1.5 6.1 100.00 UNITY BRANCH LOADS 4 5 RECEPT RM 104 1.00 RECEPTACLES 360 20 1 TOTALS 16.5 57.3 8.7 30.7 9.3 32.5 100.00 UNITY EXISTING PANEL BEING MODIFIED UNDER THIS PROJECT PANEL, INL2 OC DEVICE TYPES Breaker ENCLOSURE, NEMA 1 MAINSCA)i MLO CONTINUOUSCA)s 150 LOCATIONS DEVICE FAMILY# Bolt On MOUNTINGS Flush WIRINGS 3 -Phase 4 -Wire BUS SC RATING(A) 10000 FED FROMs PNL INLDI VOLTAGEe 208 /120 FAULT CURRENT(A)i 7566 EXISTING PANEL FED BY 150A BKR CKT DESCRIPTION NOTES DEMAND VA OC PHASE OC VA DEMAND NOTES DESCRIPTION CKT KVA AMPS KVA CODE P F AMPS P 2 AMPS P ALL CODE N/A 1.00 1 LOBBY 149 50.9 RECEPTACLES 1080 20 1 A 20 1 900 RECEPTACLES 19.7 PHYSICAL. THERAPY 170 2 3 ELEVATOR PIT 100.00 UNITY RECEPTACLES 540 20 1 B 20 1 720 RECEPTACLES 100.00 UNITY STORAGE 115 4 5 RECEPT RM 104 1.00 RECEPTACLES 360 20 1 C 20 1 720 RECEPTACLES A. MULTILEVEL DEMAND AND DESIGN FACTORS APPLIED AT EACH STORAGE 115 6 7 ATM RM 115 POWER FACTOR. RECEPTACLES 349 20 1 A 20 1 1080 RECEPTACLES RECEPTACLE OCC. THERAPY 110 8 9 SPARE USED TO CALCULATE SPARE 0 20 1 B 20 1 1080 RECEPTACLES OFF 116 /TREAT. 104 10 11 SPARE NOTE 1 SPARE 0 20 1 C 20 1 720 RECEPTACLES TREATMENT ROOM 109 12 13 SPARE NOTE 1 SPARE 0 20 1 A 20 1 720 RECEPTACLES OCC. THERAPY 110 14 15 SPARE NOTE 2 SPARE 0 20 1 B 20 1 720 RECEPTACLES OCC. THERAPY 110 16 17 SPARE SPARE 0 20 1 C 20 1 900 RECEPTACLES MASSAGE THERAPY 126 18 19 SPARE SPARE 0 20 1 A 20 1 900 RECEPTACLES NOTES 162 HOUSEKEEPING 129 20 21 SPARE SPARE 0 20 1 B 20 1 360 RECEPTACLES NOTES 162 LOCKSMITH 131 22 23 OCCUP. THERAPY 110 CONTINUOUS L 1400 20 1 C 20 1 720 RECEPTACLES NOTES 162 LOCKSMITH 131 24 25 TREAT /STD 107 /EQ 192 CONTINUOUS L 1600 20 1 A 20 1 1080 RECEPTACLES NOTES 162 CORRIDOR 112,130,132 26 27 CORR 112/MAINT./OFF NOTE 1 CONTINUOUS L 1185 20 1 B 20 1 720 RECEPTACLES NOTES 162 OFFICE 113/MAINT 128 28 29 LOBBY 149 NOTE 1 CONTINUOUS L 600 20 1 C 20 1 600 GENERAL EQUI NOTES 162 WATER COOLER 198 30 31 SPARE SPARE 0 20 1 A 20 1 760 CONTINUOUS L NOTES 162 CORRIDOR 32 33 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 34 35 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 36 37 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 38 39 SPARE NOTE 2 SPARE 0 20 1 B 20 1 0 SPARE SPARE 40 41 SPARE SPARE 0 20 1 C 20 1 0 SPARE I SPARE 42 ALL CONNECTED KVA MAX PH AMPS a PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 19.81 70.5 its A-N 8469.0 70. 5 CONNECTED 19.81 TOTAL DEMAND 11.61 40.0 a B-N 5325.0 44.3 DEMAND 11.61 TOTAL DESIGN 13.00 44.9 a C-N 6020.0 50. 1 DESIGN 13.00 NOTEi ALL LOADS ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED. NOTE It RELOCATED CIRCUIT FROM PANEL INL4 NOTE 21 CONNECT TO EXISTING SPARE CIRCUIT BREAKER DEMAND CALCULATION: FIRST DEMAND NEXT DEMAND DESIGN FACTOR NOTES GENERAL EQUIPMENT ----------------------------------------------------------------------------------- ITEM DESCRIPTION - CONNECTED MAX PH - DEMAND MAX PH - DESIGN MAX PH - -- KVA AMPS KVA AMPS KVA AMPS P F ----------------------------------------------------------------------------------- END USE LOADS 2 CONTINUOUS LIGHTING ALL 100% N/A 1.00 RECEPTACLES 13.7 50.9 5.5 20.3 5.5 20.3 100.00 UNITY CONTINUOUS LIGHT 5.5 19.7 5.5 19.7 6.9 24.6 100.00 UNITY GENERAL EQUI PMEN 0.6 5.0 0.6 5.0 0.6 5.0 100.00 UNITY BRANCH LOADS ALL 10% N/A 1.00 26.6 NOTES: UNITY TOTALS 19.8 70.5 11.6 40.0 13.0 44.9 100.00 UNITY 1/4"° LETTERS FOR PANELBOARDS AND ATS'S NOTES: I• NAMEPLATE TO BE Ille PHENOLIC PLASTIC LAMINATE WITH COLORS AS FOLLOWS: COLOR TYPE: I. FACE TO BE BLACK, ENGRAVED LETTERS TO BE WHITE FOR NORMAL SYSTEM. 2. FACE TO BE ORANGE, ENGRAVED LETTERS TO BE BLACK FOR CRITICAL BRANCH. 3. FACE TO BE YELLOW, ENGRAVED LETTERS TO BE BLACK FOR LIFE- SAFETY BRANCH. 4. FACE TO BE GREEN, ENGRAVED LETTERS TO BE BLACK FOR EQUIPMENT SYSTEM. 5. FACE TO BE PURPLE, ENGRAVED LETTERS TO BE WHITE FOR ESSENTIAL SYSTEM. 6. FACE TO BE CYAN, ENGRAVED LETTERS TO BE WHITE FOR UPS SYSTEM. 2. SECURE NAMEPLATE TO SURFACES WITH (2) FLAT HEAD BRASS SCREWS. PANELBOARD IDENTIFICATION NTS NOTE: ALL PANELBOARDS INVOLVED IN THIS PROJECT (EXISTING AND NEW) SHALL BE IDENTIFIED BY THE PANEL NAME, BRANCH OF THE ELECTRICAL SYSTEM AND FEED. REFER TO THE SPECIFICATIONS FOR COLORS AND ADDITIONAL REQUIREMENTS. DEMAND TABLE LOAD DESCRIPTION ---------------------------------------------------------------------------------- FIRST DEMAND NEXT DEMAND DESIGN FACTOR NOTES GENERAL EQUIPMENT ALL 100% N/A 1.00 OC LIGHTING 50 40% REMAINDER 20% 1.00 1 RECEPTACLES 50 40% REMAINDER 20% 1.00 2 CONTINUOUS LIGHTING ALL 100% N/A 1.00 MOTOR LOADS ALL 100% N/A 1.00 3 LARGEST MOTOR ALL 100% N/A 1.25 AHU -1 -2 X -RAY LARGEST ALL 50% N/A 1.00 _ X -RAY NEXT LARGEST ALL 25% N/A 1.00 GENERAL EQUI PMEN X -RAY REMAINDER ALL 10% N/A 1.00 26.6 NOTES: UNITY RECEPTACLES 0.7 6.0 0.3 A. MULTILEVEL DEMAND AND DESIGN FACTORS APPLIED AT EACH LOAD BUS. 2.4 B. LOAD TOTALS CALCULATED USING COMPLEX ADDITION BASED ON POWER FACTOR. MOTOR LOADS 1. HOSPITAL GENERAL ILLUMINATION DEMAND FROM NEC TABLE 220.42 60 3 8646 2. HOSPI TAL GENERAL RECEPTACLE LOAD DEMAND FROM NEC TABLE 220. 42 ( PER ART. 220. 44) 3. LARGEST MOTOR CIRCUIT IDENTIFIED AND USED TO CALCULATE DESIGN LOAD - BASED ON NEC ART 430. •• - CONTINUOUS L EXISTING PANELS BEING MODIFIED UNDER THIS PROJECT PANEL, IEQL2 OC DEVICE TYPE, Breaker ENCLOSURE, NEMA 1 MAINSCA)s MLO CONTINUOUS(A)t 225 LOCATIONM DEVICE FAMILYt Bolt On MOUNTING, Flush WIRINGS 3 -Phase 4 -Mire BUS SC RATINGCN 22000 FED FRONT PNL 1EQLD2 VOLTAGEi 208 /120 FAULT CUJRRENT(A)s 8600 EXISTING PANEL FED BY 225A BKR CKT DESCRIPTION NOTES DEMAND VA OC PHASE OC VA DEMAND NOTES DESCRIPTION CKT KVA KVA AMPS CODE AMPS AMPS P AMPS AMPS P W CODE L 1 AHU -1 -1 NOTE 1 MOTOR LOADS 3963 30 3 A 60 3 8646 MOTOR LOADS 36.3 AHU -1 -2 2 3 .. 8.6 24.0 _ .. B .. _ UNITY GENERAL EQUI PMEN .. 4 9.6 26.6 9.6 26.6 100.00 UNITY RECEPTACLES 0.7 6.0 0.3 2.4 0.3 2.4 7 AHU -1 -3 BRANCH LOADS MOTOR LOADS 6125 45 3 A 60 3 8646 LARGEST MOM AHU -1 -4 8 9 •• NOTE 1 RECEPTACLES - •• B •• - CONTINUOUS L •• 10 it EXAM 146 - 148 NOTE 1 RECEPTACLES 540 20 1 20 1 1520 CONTINUOUS L OCC THER 110/MASSAG 12 13 AHU --1 -5 NOTE 1 MOTOR LOADS 3963 30 3 A 45 3 6125 MOTOR LOADS AHU -1 -6 14 15 OFFICE 138 6 140 NOTE 2 RECEPTACLES - 20 1 B 20 1 - CONTINUOUS L GROUP RMS 176,181,85 16 17 SPARE SPARE - 20 1 C 20 1 - CONTINUOUS L REC THER 15/REC 159 18 19 1ST FLR DAMPERS GENERAL EQUI 800 20 1 A 20 1 800 GENERAL EQUI 2ND FLR DAMPERS 20 21 1ST FLR TERMINAL BOX GENERAL EQUI 800 20 1 B 20 1 800 GENERAL EQUI 2ND FLR TERMINAL BOX 22 23 1ST FLR DAMPERS GENERAL EQUI 800 20 1 C 20 1 800 GENERAL EQUI 2ND FLR DAMPERS 24 25 1ST FLR TERMINAL BOX GENERAL EQUI 800 20 1 A 20 1 800 GENERAL EQUI 2ND FLR TERMINAL BOX 26 27 1ST FLR DAMPERS NOTE 1 GENERAL EQUI 800 20 1 B 20 1 800 GENERAL EQUI 2ND FLR RECIR PUMPS 28 29 1ST FLR HW CONTROLS NOTE 1 GENERAL EQUI 800 20 1 C 20 1 800 GENERAL EQUI TRANE EQUIP 30 31 AHU RMS RECEPTACLES 720 20 1 A 30 3 3963 MOTOR LOADS ARJ -2 -1 32 33 EF -1 -3 MOTOR LOADS 822 20 1 B 20 1 - RECEPTACLES VENDING MACHINE 34 35 EF -1 -1 MOTOR LOADS 1177 20 1 C •' - RECEPTACLES VENDING MACHINE 36 37 EF -1 -2 MOTOR LOADS 697 20 1 A 20 1 0 SPARE SPARE 38 39 EF -1-6 NOTE 2 MOTOR LOADS 865 20 1 B 20 1 0 SPARE SPARE 40 41 SPARE SPARE 0 20 1 C 20 1 0 SPARE I SPARE 42 ALL CONNECTED KVA MAX PH AMPS a PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 55.31 155.7 is A-N 18426.7 153.4 CONNECTED 55.31 TOTAL DEMAND 54.88 155.7 a B-N 18696.9 155.7 DEMAND 54.88 TOTAL DESIGN 57.04 161.7 a C -N 18187.1 151.4 DESIGN 57.04 NOTES ALL LOADS ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED NOTE It REUSE EXISTING CIRCUIT (PREVIOUSLY SERVING AREA) NOTE a CONNECT TO EXISTING SPARE CIRCUIT BREAKER DEMAND CALCULATION: LOCATION DEVICE FAMILYt Bolt On MOUNTINGi Surface WIRINGS 3 -Phase 4 -Wire BUS SC RATING(A) 22000 FED FROM PNL 2=1 VNLTAGEs 208/120 FAULT CURRENT(A)i 9904 EXISTING PANEL FED BY 150A BKR CKT DESCRIPTION! NOTES DEMAND ----------------------------------------------------------------------------------- ITEM DESCRIPTION * CONNECTED MAX PH * DEMAND MAX PH - DESIGN MAX PH - X CKT KVA KVA AMPS KVA AMPS KVA AMPS P F W ----------------------------------------------------------------------------------- END USE LOADS L 1 LOUNGE 134 - REF NOTE 1 GENERAL. EQUI 800 MOTOR LOADS 36.3 105.0 36.3 105.0 36.3 105.0 100.00 UNITY LARGEST MOTOR 8.6 24.0 8.6 24.0 10.8 30.0 100.00 UNITY GENERAL EQUI PMEN 9.6 26.6 9.6 26.6 9.6 26.6 100.00 UNITY RECEPTACLES 0.7 6.0 0.3 2.4 0.3 2.4 100.00 UNITY BRANCH LOADS RECEPTACLES 540 20 i A 20 1 1250 CONTINUOUS L TOTALS 55.3 155.7 54.9 155. 7 57. 0 161.7 100.00 UNI TY PANED ICLI OC DEVICE TYPE, Breaker ENCLOSURE, NEMA 1 MAINSCA)i MLO CONTINUOUS(A)i 150 LOCATION DEVICE FAMILYt Bolt On MOUNTINGi Surface WIRINGS 3 -Phase 4 -Wire BUS SC RATING(A) 22000 FED FROM PNL 2=1 VNLTAGEs 208/120 FAULT CURRENT(A)i 9904 EXISTING PANEL FED BY 150A BKR CKT DESCRIPTION! NOTES DEMAND VA OC PHASE OC VA DEMAND NOTES DESCRIPTION CKT KVA AMPS ------ KVA - - - CODE P- F - - - - -- AMPS P AMPS P W CODE L 1 LOUNGE 134 - REF NOTE 1 GENERAL. EQUI 800 20 1 A 20 1 360 RECEPTACLES 34. 0 TELECOM ROOM 125 2 3 SCREENING 135 NOTE 1 RECEPTACLES 540 20 1 B 20 1 360 RECEPTACLES 100.00 UNITY TELECOM ROOM 125 4 5 INFUSION 142 NOTE 1 RECEPTACLES 540 20 1 C 20 1 1280 CONTINUOUS L 100.00 UNITY HEART RHYTHM LIGHT 6 7 INFUSION 142 NOTE 1 RECEPTACLES 540 20 i A 20 1 1250 CONTINUOUS L LOCI( 131/MAINT/OFF. 8 9 EXAM 146 - 148 NOTE 1 RECEPTACLES 540 20 1 B 20 1 1413 CONTINUOUS L TREAT 104 - 109 /STO/EQ 10 11 EXAM 146 - 148 NOTE 1 RECEPTACLES 540 20 1 C 20 1 1520 CONTINUOUS L OCC THER 110/MASSAG 12 13 LOBBY RECEP DESK NOTE 1 RECEPTACLES 720 20 1 A 20 1 887 CONTINUOUS L PHY TNER 170/STO 115 14 15 OFFICE 138 6 140 NOTE 2 RECEPTACLES 900 20 1 B 20 1 853 CONTINUOUS L GROUP RMS 176,181,85 16 17 SPARE SPARE 0 20 1 C 20 1 1283 CONTINUOUS L REC THER 15/REC 159 18 19 LOCKSMITH 131 RECEPTACLES 720 20 1 A 20 1 360 RECEPTACLES TELECOM ROOM 125, 20 21 LOCKSMITH 131 RECEPTACLES 720 20 1 B 20 1 1080 RECEPTACLES OFFICES 157 -159 22 23 LOCKSMITH 131 RECEPTACLES 360 20 1 C 20 1 720 RECEPTACLES OFF 152- 155/REC THER 24 25 LOCKSMITH 131 RECEPTACLES 360 20 1 A 20 1 900 RECEPTACLES REC THERAPY REF. 26 27 MAINT 128 /HOUSEK 129 RECEPTACLES 900 20 1 B 20 1 900 RECEPTACLES OFF. 160,167 - 169,177 28 29 TREAT /OCC. THER. 110 RECEPTACLES 720 20 1 C 20 1 1080 RECEPTACLES OFF. 183,191,194-196 30 31 ATM 147 RECEPTACLES 360 20 1 A 20 1 900 RECEPTACLES FOOD SERVICE DISPLAY 32 33 OCC. THERAPY 110 RECEPTACLES 720 20 1 B 20 1 800 RECEPTACLES VENDING MACHINE 34 35 PHYSICAL THERAPY 170 RECEPTACLES 540 20 1 C 20 1 800 RECEPTACLES VENDING MACHINE 36 37 PYS THER/ RM 164 /165 RECEPTACLES 540 20 1 A 20 1 800 RECEPTACLES VENDING MACHINE 38 39 STORAGE 115 RECEPTACLES 360 20 1 B 20 1 600 GENERAL EQUI NCT 40 41 TELECOM ROOM 125 RECEPTACLES 360 20 1 C 20 1 180 RECEPTACLES I SECURITY CORR#161 42 43 SEC GATE VALET PARKI TOTAL DEMAND 5.74 20.5 a B-N 1980.0 16.5 DEMAND 5.74 GENERAL EQUI 500 20 1 A 20 1 0 SPARE SPARE 44 45 EXAM 164 RECEPTACLES 360 20 1 B 20 1 0 SPARE SPARE 46 47 EXAM 165 RECEPTACLES 360 20 1 C 20 1 0 SPARE SPARE 48 49 EXAM 139 6 141 NOTE 2 RECEPTACLES 720 20 1 A 20 1 0 SPARE SPARE 50 51 CLEAN STORAGE 143 NOTE 2 RECEPTACLES 180 20 1 B 20 1 0 SPARE SPARE 52 53 CLN STO 143 - PYXIS NOTE 2 GENERAL EQUI 1000 20 1 C 20 1 0 SPARE SPARE 54 55 REGISTRATION 150 NOTE 2 RECEPTACLES 540 20 1 A 20 1 0 SPARE SPARE 56 57 REGISTRATION 150 NOTE 2 RECEPTACLES 540 20 1 B 20 1 0 SPARE SPARE 58 59 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 60 61 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 62 63 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 64 65 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 66 67 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 68 69 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 70 71 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 72 73 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 74 75 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 76 77 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 78 79 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 80 81 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 82 83 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 84 ALL CONNECTED KVA MAX PH AMPS a PHASE TOTALS VA IMPS BUS TOTALS KVA TOTAL CONNECTED 34.31 98. 0 a A-N 11257.0 93.7 CONNECTED 34.31 TOTAL DEMAND 20. 55 63.0 a B-N 11766.0 98. 0 DEMAND 20.55 TOTAL DESIGN 22.68 71.5 a C-N 11283.0 94.0 DESIGN 22.68 NOTEi ALL LOADS ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED NOTE 1s REUSE EXISTING CIRCUIT (PREVIOUSLY SERVING AREA) NOTE 21 CONNECT TO EXISTING SPARE CIRCUIT BREAKER DEMAND CALCULATION: LOCATION: DEVICE FAMILYt Bolt On MOUNTINGS Surface WIRIM 3 -Phase 4 -Wire BUS SC RATING(A) 10000 FED FROMs PNL 2LSLD1 VOLTAGEt 208 /120 FAULT CURRENT(A)e 5249 EXISTING PANEL FED BY IOOA BKR CKT DESCRIPTION NOTES ----------------------------------------------------------------------------------- ITEM DESCRIPTION * CONNECTED MAX PH • DEMAND MAX PH * DESIGN MAX PH • X NOTES KVA AMPS KVA AMPS ------ KVA - - - -- AMPS--- P- F - - - - -- ----------------------------------------------------------------------------------- END USE LOADS AMPS P W CODE L RECEPTACLES 22. 9 74.1 9.2 29. 6 9.2 29. 6 100.00 UNI TY CONTINUOUS LIGHT 8.5 34. 0 8.5 34. 0 10.6 42.5 100.00 UNITY GENERAL EQUI PMEN 2.9 10. B 2.9 10. 8 2.9 10. 8 100.00 UNITY BRANCH LOADS 4 5 FACP WU TOTALS 34. 3 98.0 20.6 63.0 22.7 71.5 100.00 UNITY PANEL, ILSLI OC DEVICE TYPE, Breaker ENCLOSURE, NEMA 1 MAINS(A)s MLO CONTINUOUSCA)s 100 LOCATION: DEVICE FAMILYt Bolt On MOUNTINGS Surface WIRIM 3 -Phase 4 -Wire BUS SC RATING(A) 10000 FED FROMs PNL 2LSLD1 VOLTAGEt 208 /120 FAULT CURRENT(A)e 5249 EXISTING PANEL FED BY IOOA BKR CKT DESCRIPTION NOTES DEMAND VA OC PHASE OC VA DEMAND NOTES DESCRIPTION CKT U. CODE AMPS P AMPS P W CODE L 1 GENERATOR ROOM RECEPTACLES 360 20 1 A 20 1 920 CONTINUOUS L LOBBY /HEART RHYTHM 2 3 GENERATOR ROOM CONTINUOUS L 200 20 1 B 20 1 880 CONTINUOUS L CORRIDOR 4 5 FACP WU GENERAL EQUI 400 20 1 C 20 1 400 CONTINUOUS L CC i.. SOUTH WALL EXTERIOR 6 7 FATC GENERAL EQUI 400 20 1 A 20 1 500 CONTINUOUS L FLOOD LTS SW MALL 8 9 ELEVATOR CAB LTS r� V/ CONTINUOUS L 400 20 1 B 20 1 500 CONTINUOUS L FLOOD LTS NE WALL 10 11 MGAP FIBRIOD CENTER GENERAL EQUI 500 20 1 C 20 1 0 SPARE SPARE 12 13 MGAP HEART RHTYHM NOTE 1 GENERAL EQUI 500 20 1 A 20 1 0 SPARE SPARE 14 15 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 16 17 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 18 19 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 20 21 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 22 23 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 24 25 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 26 27 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 28 29 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 30 31 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 32 33 SPARE SPARE 0 20 1 B 20 1 0 SPAN SPARE 34 35 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 36 37 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 38 39 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 40 41 ISPARE SPARE 1 0 20 1 C 1 20 1 0 SPARE I SPARE 42 ALL CONNECTED KVA MAX PH AMPS a PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 5.96 22. 3 a A-N 268M 0 22. 3 CONNECTED 5.96 TOTAL DEMAND 5.74 20.5 a B-N 1980.0 16.5 DEMAND 5.74 TOTAL DESIGN 6.69 23.5 a C-N 1300.0 10.8 DESIGN 6.69 NOTE, ALL LOADS ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED NOTE 11 CONNECT TO EXISTING SPARE CIRCUIT BREAKER DEMAND CALCULATION: ----------------------------------------------------------------------------------- ITEM DESCRIPTION • CONNECTED MAX PH • DEMAND MAX PH • DESIGN MAX PH * X KVA AMPS KVA AMPS KVA AMPS P F END USE LOADS RECEPTACLES 0.4 3.0 0.1 1.2 0.1 1.2 100.00 UNITY GENERAL EOUI PMEN 1. 8 7.5 1.8 7.5 1.8 7.5 100.00 UNITY CONTINUOUS LIGHT 3.8 16.5 3.8 16.5 4.8 20.6 100.00 UNITY BRANCH LOADS ----------------------------------------------------------------------------------- TOTALS 6.0 22.3 5.7 20.5 6.7 23.5 100.00 UNITY INL4 1EQL2 INL2 ICLI Drawn: I LSL1 Revised: co co M U. O w J W � L Q Z W i DV/ 02 °z i 0) W G _�- WU INL4 1EQL2 INL2 ICLI Drawn: I LSL1 Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Certification - EB -0000857 Michael A. Steward PE - 65701 John E. Moulder PE - 33200 SSR JOB # 1232016.0 O r- m 0 p so M ( 00 r -�r„� E rl- co C14 to 0 L6 r-_ U*) N C V T 0) ` C004 �@'vN Q2 .0 Z � ° 0 C9 0 c0o�^r°ncm6aoo = .: 0= =d mU iftL- aOo - v)H¢ Comm. No: 12007.00 co 05/22/12 Drawn: Revised: co co M U. O w J W � L Q Z W i DV/ 02 °z 0) W G _�- WU J a: CC i.. O a co Uj F_ z W CO v r� V/ F V/ < 04 O mtn coU Comm. No: 12007.00 Date: 05/22/12 Drawn: Revised: P IFJr,ATIPW, PLY.WrrH TH. AN e71j,.t�ti1F * 065 1 L}< LLJ w / OF ©20f ,y '� �lq L'?, INC E6.1