Loading...
12-965-039rte■ t a� a O N r\ hi v D 0 d r I In E I Q Q N to N i N Q N N E v v I— ai E v c a� ii LAVATORY FAUCET MAXLINE VALVE- HOT VALVE ALVE TANK, HEATER, TEMPERED ETC. HOT SUPPLY MAIN HOT SUPPLY VALVE COLD SUPPLY NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. SET TEMPERATURE TO 1100 MAXIMUM PER FBC. MIXING VALVE PIPING AT FAUCETS COUNTERTOP COUNTERTOP SINK. INSTALL PER MANUFACTURER'S REQUIREMENTS USING MANUFACTURER'S MOUNTING KIT. REFER TO MANUFACTURER'S CUT SHEET. CONTRACTOR TO INSTALL COUNTERSUNK MACHINE SCREWS FROM THE TOP OF THE 314 PLYWOOD. SECURE THROUGH UNDERSIDE OF PLYWOOD USING LOCK WASHERS AND NUTS WITH LOCKTITE THREAD LOCKER AT THE FRONT AND AT THE BACK SIDE OFTHE REAR SLOT. 4 SCREWS MINIMUM - 2 PER ARM. COORDINATE WORK WITH COUNTERTOP SPECIFIED BY ARCHITECT. EXPOSED ARMS OF CARRIER. COORDINATE ARM LENGTHS WITH COUNTERTOP DEPTH. —FLOOR MOUNTED CONCEALED CARRIER ZURN *Z -1236 WITH EXPOSED ARMS TO SUPPORT COUNTER. INSTALL TO ACCOMMODATE 300 LBS. .ti . .t: tea. . •t. PHILLIPS CONCRETE FASTENS I.T.T. GRINNELL (RED HEAD) ALL THREAD HANGER ROD PIPE HANGER RING I.T.T. GRINNELL FIG.69 PIPE HANGER RING / \— PIPE I.T.T. GRINNELL FIG.26Or PIPES 21/2 & SMALLER PIPES 3" & LARGER NOTE: 1. PROVIDE COPPER PLATING ON HANGER BETWEEN STEEL AND COPPER WHERE UNINSULATED COPPER PIPING IS USED. 2. PROVIDE ADDITIONAL HANGERS ON EACH SIDE OF A WALL WHERE THE PIPING PENETRATES THE WALL. 3. ALL EXTERIOR HANGERS SHALL BE STAINLESS STEEL INCLUDING CLAMPS, THREADED RODS, NUTS AND BOLTS. 4. ALL INTERIOR HANGERS SHALL BE GALVANIZED INCLUDING CLAMPS, THREADED RODS, NUTS AND BOLTS. 5. ALL PLUMBING TRADE ITEMS SHALL BE INDIVIDUALLY AND RIGIDLY SUPPORTED FROM STRUCTURE ABOVE INDEPENDENT OF ALL OTHER TRADES. (DO NOT HANG PLUMBING ITEMS FROM ANOTHER TRADE.) U.L./F.M. APPROVED CONCRETE INSERT PIPING HANGER DETAIL HANGER ROD. PROVIDE A SECTION OF HIGH COMPRESSION STRENGTH INSULATION AT EACH HANGER POINT. INSULATION MAY BE HALF ROUND OR FULL ROUND AND EXTEND 2' BEYOND GALVANIZED SHIELD EACH WAY. GALVANIZED SHIELD NOTE: HANDLES TO BE POSITIONED AT AN 180A ANGLE IN THE CLOSED POSITION. TYPICAL GOOSENECK INSTALLATION LINE PRESSURE ALARM 0 0 O m UNINSULATED COPPER LINES PIPE CLAMPS WITH CUSHIONS 'PHD' MANUFACTURING MODEL ro In 2501-2514 h 91191 1 _ �;bj \' 1 1 1 r--t I +j METAL CHANNEL STRUT INSULATED PIPE LINE WIT PIPE CLAMP. PROVIDE INSULATION SHIELD ON 3' NOTES: AND LARGER. 1. TRAPEZE HANGERS SHALL NOT BE USED ON STORM, OVERFLOW STORM OR SANITARY PIPING SYSTEMS. 2. PROVIDE ADDITIONAL HANGERS ON EACH SIDE OF A WALL WHERE THE PIPING PENETRATES THE WALL. 3. ALL EXTERIOR HANGERS SHALL BE STAINLESS STEEL INCLUDING CLAMPS, THREADED RODS, NUTS AND BOLTS. 4. ALL INTERIOR HANGERS SHALL BE GALVANIZED INCLUDING CLAMPS, THREADED RODS, NUTS AND BOLTS. 5. ALL PLUMBING TRADE ITEMS SHALL BE INDIVIDUALLY AND RIGIDLY SUPPORTED FROM STRUCTURE ABOVE INDEPENDENT OF ALL OTHER TRADES. (DO NOT HANG PLUMBING ITEMS FROM ANOTHER TRADE.) NOTES: VALVE BOX GAS OUTLETS { o x o ca � FINISHED FLOOR-\ 1. LINE PRESSURE ALARM (L.P.A.) PANELS ARE NOT TO BE LOCATED OVER ZONE VALVE BOXES (Z.V.B.) 2. COORDINATE MOUNTING HEIGHTS WITH ARCHITECTURAL DRAWINGS. IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT AND ENGINEER PRIOR TO INSTALLATION. COUNTERTOP SINK FLOOR MOUNTED I e TRAPEZE PIPE HANGER 11.1 MEDICAL GAS MOUNTING HEIGHT DETAIL I e SUPPORT SRSmith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Certification - EB- 0000857 Michael A. Steward PE - 65701 John E. Moulder PE - 33200 SSR JOB # 1232016.0 i i IIIIIIIIIIIIIIIIIIN Q r r Comm. No: 12007.00 C.') r t0 05/22/12 E Co co C ~ U N� 'NO��A°td �, O 7 (6M p�� f0 �C-104 � -2 N_ O 0 0 T r � Cc J Y co a E U 0 c E LL U- -) O n- v) 1— Comm. No: 12007.00 M 05/22/12 Drawn: Revised: T M a: UL 0 E W _w U. F Q z = W E V E cl) = W _�- F— E WU M =moo EI— Vz E E Cr _ U cc 0 CO Z 'Q N a m 0) CID U Comm. No: 12007.00 Date: 05/22/12 Drawn: Revised: