LAVATORY
FAUCET
MAXLINE
VALVE-
HOT VALVE
ALVE
TANK,
HEATER, TEMPERED
ETC. HOT SUPPLY
MAIN HOT SUPPLY
VALVE
COLD SUPPLY
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. SET TEMPERATURE TO 1100 MAXIMUM PER FBC.
MIXING VALVE PIPING AT FAUCETS
COUNTERTOP
COUNTERTOP SINK. INSTALL PER
MANUFACTURER'S
REQUIREMENTS USING MANUFACTURER'S
MOUNTING
KIT. REFER TO MANUFACTURER'S CUT
SHEET.
CONTRACTOR TO INSTALL COUNTERSUNK MACHINE SCREWS
FROM THE TOP OF THE 314 PLYWOOD. SECURE THROUGH
UNDERSIDE OF PLYWOOD USING LOCK WASHERS AND NUTS
WITH LOCKTITE THREAD LOCKER AT THE FRONT AND AT
THE BACK SIDE OFTHE REAR SLOT. 4 SCREWS MINIMUM -
2 PER ARM. COORDINATE WORK WITH COUNTERTOP
SPECIFIED BY ARCHITECT.
EXPOSED ARMS OF CARRIER.
COORDINATE ARM LENGTHS
WITH COUNTERTOP DEPTH.
—FLOOR MOUNTED CONCEALED CARRIER
ZURN *Z -1236 WITH EXPOSED ARMS TO
SUPPORT COUNTER. INSTALL TO
ACCOMMODATE 300 LBS.
.ti . .t: tea. . •t.
PHILLIPS CONCRETE FASTENS
I.T.T. GRINNELL (RED HEAD)
ALL THREAD
HANGER ROD
PIPE HANGER RING
I.T.T. GRINNELL FIG.69
PIPE HANGER RING / \— PIPE
I.T.T. GRINNELL FIG.26Or
PIPES 21/2 & SMALLER PIPES 3" & LARGER
NOTE: 1. PROVIDE COPPER PLATING ON HANGER BETWEEN
STEEL AND COPPER WHERE UNINSULATED COPPER
PIPING IS USED.
2. PROVIDE ADDITIONAL HANGERS ON EACH SIDE OF A
WALL WHERE THE PIPING PENETRATES THE WALL.
3. ALL EXTERIOR HANGERS SHALL BE STAINLESS STEEL
INCLUDING CLAMPS, THREADED RODS, NUTS AND BOLTS.
4. ALL INTERIOR HANGERS SHALL BE GALVANIZED
INCLUDING CLAMPS, THREADED RODS, NUTS AND BOLTS.
5. ALL PLUMBING TRADE ITEMS SHALL BE INDIVIDUALLY
AND RIGIDLY SUPPORTED FROM STRUCTURE ABOVE
INDEPENDENT OF ALL OTHER TRADES. (DO NOT HANG
PLUMBING ITEMS FROM ANOTHER TRADE.)
U.L./F.M. APPROVED CONCRETE
INSERT PIPING HANGER DETAIL
HANGER ROD. PROVIDE A SECTION OF HIGH
COMPRESSION STRENGTH
INSULATION AT EACH HANGER
POINT. INSULATION MAY BE
HALF ROUND OR FULL ROUND
AND EXTEND 2' BEYOND
GALVANIZED SHIELD EACH WAY.
GALVANIZED
SHIELD
NOTE: HANDLES TO BE POSITIONED AT AN 180A ANGLE IN THE
CLOSED POSITION.
TYPICAL GOOSENECK INSTALLATION
LINE PRESSURE
ALARM
0 0
O m
UNINSULATED COPPER LINES
PIPE CLAMPS WITH CUSHIONS
'PHD' MANUFACTURING MODEL ro In
2501-2514
h 91191 1 _
�;bj \' 1 1 1 r--t I +j
METAL CHANNEL STRUT INSULATED PIPE LINE WIT
PIPE CLAMP. PROVIDE
INSULATION SHIELD ON 3'
NOTES: AND LARGER.
1. TRAPEZE HANGERS SHALL NOT BE USED ON STORM,
OVERFLOW STORM OR SANITARY PIPING SYSTEMS.
2. PROVIDE ADDITIONAL HANGERS ON EACH SIDE OF A
WALL WHERE THE PIPING PENETRATES THE WALL.
3. ALL EXTERIOR HANGERS SHALL BE STAINLESS STEEL
INCLUDING CLAMPS, THREADED RODS, NUTS AND BOLTS.
4. ALL INTERIOR HANGERS SHALL BE GALVANIZED
INCLUDING CLAMPS, THREADED RODS, NUTS AND BOLTS.
5. ALL PLUMBING TRADE ITEMS SHALL BE INDIVIDUALLY
AND RIGIDLY SUPPORTED FROM STRUCTURE ABOVE
INDEPENDENT OF ALL OTHER TRADES. (DO NOT HANG
PLUMBING ITEMS FROM ANOTHER TRADE.)
NOTES:
VALVE BOX GAS
OUTLETS
{ o
x
o
ca �
FINISHED
FLOOR-\
1. LINE PRESSURE ALARM (L.P.A.) PANELS ARE NOT TO
BE LOCATED OVER ZONE VALVE BOXES (Z.V.B.)
2. COORDINATE MOUNTING HEIGHTS WITH ARCHITECTURAL
DRAWINGS. IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT
AND ENGINEER PRIOR TO INSTALLATION.
COUNTERTOP SINK FLOOR MOUNTED I e TRAPEZE PIPE HANGER 11.1
MEDICAL GAS MOUNTING HEIGHT DETAIL I e
SUPPORT
SRSmith
Seckman
Reid, Inc.
600 West Hillsboro, Suite 300
Deerfield Beach, FL 33441
(954) 421 -1260
FAX: (954) 421 -1466
www.ssr- inc.com
Firm Certification - EB- 0000857
Michael A. Steward PE - 65701
John E. Moulder PE - 33200
SSR JOB # 1232016.0
i
i
IIIIIIIIIIIIIIIIIIN
Q r
r
Comm. No:
12007.00
C.') r
t0
05/22/12
E
Co co C ~
U
N�
'NO��A°td
�,
O
7
(6M p�� f0 �C-104 �
-2 N_ O 0 0 T r
�
Cc
J Y co a E U
0 c E
LL U- -) O n- v) 1—
Comm. No:
12007.00
M
05/22/12
Drawn:
Revised:
T
M
a:
UL
0
E
W
_w
U.
F
Q
z
=
W
E
V
E
cl)
=
W
_�-
F—
E
WU
M
=moo
EI—
Vz
E
E
Cr
_
U
cc
0
CO
Z
'Q
N
a
m
0)
CID
U
Comm. No:
12007.00
Date:
05/22/12
Drawn:
Revised: