12-939-049
❑E J PAVILION SWITCHBOARD MSNI 2000A, 3PH 4W, 277/480 as as O O O O O U O O Ln l9 T Q13 L,() NDPA 600A NORMAL BRANCH NIiIB 200A 0 NORMAL BRANCH 30KVA INLCFI I I IOOA NORMAL BRANCH 00 G G O O W co T (-D CD 2 f=P &L XFMR i_yTr_� 5 SETS(4 #75OMCM -4 "C.) 3P 2000A L ~ W 3 3000A, BUS DUCT 3000A" BUS DUCT TO FPL VAULT. TO FPL VAULT. NMSBI _T /\ NMSB2 3000A 3000A 271/180V 277/480V 3PH, _11N 3000A NC NC 3000A 3PH, 4'N MI M2 GF� GFP NO \ �\ —1 TI TI � \ 800A 800A 800A 800A 4 800KVV EMERGENCY GENERATOR PARALLELING SWITCHGEAR 5000A, 3P1 -I 41N, 277/480 1600A 1200A 800KW 1600A I ?nnA KEYED NOTES: O EXISTING PANEL BEING MODIFIED - PROVIDE UPDATED TYPED DIRECTORY. •" "" ... ... "" UUNUUII [tAIINh — _. ...... _..__.._ 120/208V FEEDER 11UNUUI1 SIZE I 3 #8 & 1 #I0G. OVERCURRENT VERCURRENT 3/4" 50 4 #8 & 1 #10G. I' 2 3 3 #6 & 1 #I0G. T9 3/4" 60 4 #6 & I #IOG. 30A, 3P 3 #12 & 1 #12G - 3/4'C. if 4 5 3 #4 & I #8G. 42 30A, 3P 1" 70 4 #4 & 1 #8G. T30 30 11/4' 6 7 3 #3 & I #8G. 4 #3 & 1 #8G - I I/ 4'C. 1 #8 - 3/41C 1 1/4' 100 4 #3 & 1#8G. 80A, 3P 150A, 3P 1 1/4" 8 9 3 #1 & 1 #6G. 90 208 1 1/4' 125 4 #1 & I #6G. 4 #250 KCMIL & 1 #213 1 #2 - 3/4'C 2" 10 II 3 #1 /0 & I #6G. I I /2' 150 4 #1 /0 & 1 #6G. 112.5 135 2" 12 13 3 #2/0 & 1 #6G. 1 #1 /0 - 3/4'C. 2' 175 4 #2/0 & I #6G. 2" 14 15 3 #3/0 & 1 #60. 417 300A, 3P 2' 200 4 #3/0 & 1 #6G. 2" 16 17 3 #4/0 & 1 #4G. 2 -2 1 /2'C. 2' 225 4 #4/0 & 1 #4G. 400A, 3P 800A, 3P 2 1/2' 18 19 3 #250 KCMIL & 1 #4G. 2 1/2" 250 4 #250 KCMIL & 1 #4G. 2 112' 20 21 3 #350 KCMIL & 1 #4G. 3' 300 4 #350 KCMIL & 1 #4G. 3" 22 23 3 #500 KCMIL & 1 #3G. 3 1/2" 350 4 #500 KCMIL & 1 #3G. 3 112' 24 25 3 #600 KCMIL & 1 #3G. 3 1/2" 400 4 #600 KCMIL & 1 #3G. 4" 26 27 6 #250 KCMIL & 2 #2G. 2-2 1/2' 500 8 #250 KCMIL & 2 #2G. 2 -2 1/2" 28 29 6 #350 KCMIL & 2 #IG. 2 -3" 600 8 #350 KCMIL & 2 #IG. 2 -3' 30 31 6 #500 KCMIL & 2 #1 /OG. 2-3" 700 8 #500 KCMIL & 2 #1 /OG. 2 -3 1/2' 32 3 6 #600 KCMIL & 2#1 /OG. 2 -3 1/2' 800 8 #600 KCMIL & 2 #1 /OG. 2 -4' 34 35 9 #400 KCMIL & 3 #2 /OG. 3 -3' 1000 12 #400 KCMIL & 3 #2 /OG. 3 -3' 36 37 9 #600 KCMIL & 3 #3 /OG. 3 -3 1/2' 1200 12 #600 KCMIL & 3 #3 /OG. 3 -4' 38 39 12 #600 KCMIL & 4 #4 /OG. 4 -3 1/2' 1600 16 #600 KCMIL & 4 #4 /OG. 4 -4' 40 41 15 #600 KCMIL & 5 #250G. 5 -3 1/2" 2000 20 #600 KCMIL & 5 #250G. 5 -4' 42 43 18 #600 KCMIL & 6 #350G. 6 -3 1/2' 2500 24 #600 KCMIL & 6 #350G. 6 -4" 44 45 21#750 KCMIL & 7 #400G. 7 -4" 3000 28 #750 KCMIL & 7 #400G. 7 -5" 46 47 27 #750 KCMIL & 9 #500G. 9-4" 11 4000 36 #750 KCMIL & 9 #500G. 9 -5" 48 NOTES: I. 600 KCMIL AND 750 KCMIL FEEDERS SHALL BE COORDINATED WITH PROPER TERMINATION LUGS OR PROVIDED WITH MAC ADAPTERS AS REQUIRED TO COORDINATE WITH STANDARD BREAKER LUG SIZES. 2. SEE SPECIFICATIONS FOR ACCEPTABLE CONDUCTOR TYPES. 1 LSLIB - 20A LIFE SAFETY BRANCH 800KW /Cc1 I� 1600A ELY 'J 80OKW 1600A 1200A NORTH TOWER SWITCHBOARD MDP 2000A, 3PH 0, 277/480 + \ )P 200A / MAIN No, 2 O� 0 0 0 0 tnLn * GG * 00 FF&L XFMR Y rY 2000A BUS DUCK CONSTRUCTION LEGEND SYMBOL DESCRIPTION PRIMARY EXISTING TO REMAIN — 208 VOLT NEW CONSTRUCTION 120/208V FEEDER EQLISA ' �\ EOL.ISA I tIOOA EQUIP, BRANCH cQ O O U O U Lr 7 NDP2 600A NORMAL BRANCH 4 #500,1 113G" IN 9 "C -4 IP. BRANCH A 500,I'13Go IN 4 11C \ 3P 1000 A / MAIN No. I Li U U Q Q 1� s 00 G O .y LSP NDPI 500A NORMAL BRANCH DRY TYPE TRANSFORMER SCHEDULE BID AND PERMIT SET 07 -30-12 PRIMARY SECONDARY 480 VOLT 208 VOLT 480V FEEDER 120/208V FEEDER GROUNDING SIZE KVA AMPS AMPS OVERCURRENT VERCURRENT SEE NOTE #2 SEE NOTE #2 SEE NOTE #3 SEE NOTE #1 T9 9 II 25 20A, 3P 30A, 3P 3 #12 & 1 #12G - 3/4'C. 4 #10 & I #8G - 3/4 "C. 1 #8 - 3/4'C TI5 15 18 42 30A, 3P 50A, 3P 3 #10 & I #IOG - 3/4'C. 4 #8 & I #$G - I "C. I #8 - T30 30 36 83 60A, 3P IOOA, 3P 3 #6 & I #IOG - 3/4'C. 4 #3 & 1 #8G - I I/ 4'C. 1 #8 - 3/41C T45 45 54 125 80A, 3P 150A, 3P 3 #4 & I #8G - INC. 4 #1 10 & 1 #6G - 2 "C. 1 #6 - 3/4 "C T75 75 90 208 150A, 3P 250A, 3P 3 #1 /0 & I #6G - 1 1 /2 1C. 4 #250 KCMIL & 1 #213 1 #2 - 3/4'C - 2 1 /2'C. T112 112.5 135 313 200A, 3P 400A, 3P 3 #3/0 & 1 #6G - 2'C. 4#400 KCMIL & I #I /OG 1 #1 /0 - 3/4'C. T150 150 181 417 300A, 3P 500A, 3P 3 #350 KCMIL & 1 #4G 8 #250 KCMIL & 2 #1 /OG 1 #1 /0 - 3/4 "C - 3 "C. 2 -2 1 /2'C. T225 225 271 625 400A, 3P 800A, 3P 3 #600 KCMIL & 1 #3G 8 #600 KCMIL & 2 #3 /OG 1 #3/0 - 3/4 "C - 3 1 /2 1C. 2 -4'C. T300 300 361 833 600A, 3P IOOOA, 3P 6 #350 KCMIL & 2 #IG 12 #400 KCMIL & 3 #3 /OG 1 #3/0 - 3/4 "C 2 -3'C. 3 -3 "C. T500 500 602 1389 900A, 3P 1600A, 3P 9 #350 KCMIL & 3 #2 /OG 16 #600 KCMIL & 4 #35OG 1 #350KCMIL -I'C. 3 -3'C. 4 -4'C. TRANSFORMER NOTES: I. SECONDARY OVERCURRENT PROTECTION SHALL BE LOCATED WITHIN TEN (10) FEET OF THE TRANSFORMER SECONDARY TERMINALS EITHER IN A PANELBOARD (MAIN BREAKER) OR A INDIVIDUALLY MOUNTED CIRCUIT BREAKER. 2. ALL CONDUCTOR SIZES ARE BASED ON N.E.C. TABLE 310 -16 FOR COPPER CONDUCTORS. 3. TRANSFORMER BONDING JUMPER AND GROUNDING ELECTRODE CONDUCTOR (COPPER CONDUCTORS). BOND THE NEUTRAL OF THE TRANSFORMER SECONDARY TO THE TRANSFORMER CASE, WITH BONDING JUMPER. GROUND THE CASE OF THE TRANSFORMER WITH THE GROUNDING ELECTRODE CONDUCTOR TO THE NEAREST AVAILABLE EFFECTIVELY GROUNDED STRUCTURAL METAL MEMBER OF THE STRUCTURE, OR THE NEAREST AVAILABLE EFFECTIVELY GROUNDED METAL WATER PIPE OR OTHER ELECTRODES AS SPECIFIED IN N.E.C. SECTIONS 250 -50 AND 250 -52 WHERE THE PRECEDING ELECTRODES ARE NOT AVAILABLE. 4. 600 KCMIL CONDUCTORS SHALL BE COORDINATED WITH PROPER TERMINATION LUGS OR PROVIDED WITH MAC ADAPTERS AS REQUIRED TO COORDINATE WITH STANDARD BREAKER LUG SIZES. ARRAY healtheare facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Boca Raton, FL 33487 1:561.995.1700 f:561.995.1701 firm license number www.arrayhfs.com AA26000880 SEAL: ,w I I I I I I I// �C °�XC,EP7S ¢ , 6576`' CONSULTANTS: SRSmith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421. -1466 www.ssr- inc.com Firm Certification - EB- 0000857 Michael A. Steward PE - 65701 John E. Moulder PE - 33200 SSR JOB # 1232003.0 OWNER: BAPTIST HEALTH HOSPITAL: SOUTH MIAMI HOSPITAL PROJ ECT: Info Desk and Coffee Shop ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 7 BID AND PERMIT SET 07 -30-12 N0. DESCRIPTION DATE REVISIONS /ISSUES SHEET TITLE: ELECTRICAL ONE -LINE DIAGRAM DRAWN: FL CHECKED: CON /REF No. 00000 PROJECT No. 3601 DATE: 07/30/12 SCALE: As indicated SHEET NO. E3.1 Ihis doc�.irnenl u i cG)qi;hi. pi:��ca�d irr:lii.¢ncnl ci rrerc, �"iN`�:} '.f AREA arrl Ilcensed rcr use in the i 6 >:I pro; et only. ;'e, :�uctrr u� ,rs .f tFi I,-.c_rn�n; ei' -h,�i� rnit �,n p:rn�l °, r. at APf i illa�a.�d :uid viill h. . c,�.errf� l i �;lrr -h� I;u. COPYRIGHT - 2012 ARRAY HFS