12-939-043E C C !1 J LL 1 2 3 4 0 6 7 Lo7 -30 -12 N0. DESCRIPTION DATE REVISIONS /ISSUES PIPE HANGER RING I.T.T. GRINNELL FIG,69 ____F PIPE HANGER RING PIPE I.T.T. GRINNELL FIG.26 PIPES 21/2" & SMALLER PIPES 3" & LARGER NOTE: I. PROVIDE COPPER PLATING ON HANGER BETWEEN STEEL AND COPPER WHERE UNINSULATED COPPER PIPING IS USED. 2. PROVIDE ADDITIONAL HANGERS ON EACH SIDE OF A WALL WHERE THE PIPING PENETRATES THE WALL. 3. ALL EXTERIOR HANGERS SHALL BE STAINLESS STEEL INCLUDING CLAMPS, THREADED RODS, NUTS AND BOLTS. 9. ALL INTERIOR HANGERS SHALL BE GALVANIZED INCLUDING CLAMPS, THREADED RODS, NUTS AND BOLTS. 5. ALL PLUMBING TRADE ITEMS SHALL BE INDIVIDUALLY AND RIGIDLY SUPPORTED FROM STRUCTURE ABOVE INDEPENDENT OF ALL OTHER TRADES. (DO NOT HANG PLUMBING ITEMS FROM ANOTHER TRADE.) U.L. /F.M. APPROVED CONCRETE INSERT PIPING HANGER DETAIL 2" RELIEF VENT PERMANENT SIGN OR TAG PROVIDE "DRY WELL" 2" GALVANIZED STEEL INSECT VENT COATED BELOW SCREEN —CAST IRON COVER GRADE WITH ENAMEL \ GRADE BASE PAINT 4" / BELOW 12" MINIMUM GRADE 2" C. D. —24" 0 X 3' LONG CONCRETE PIPE OR VITRIFIED CLAY PEA GRAVEL CONDENSATE DRYWELL N 0 T E : ELEVATE A/C UNIT SUFFICIENT DISTANCE ABOVE FLOOR OR ROOF TO ALLOW FOR INSTALLATION OF TRAP WITH ADEQUATE AVOID DIRECT INSTALLATION DIMENSIONS TO WITHSTAND SYSTEM TO PREVENT FOREIGN MATERIAL OPERATING PRESSURE. COORDINATE FROM ENTERING DIRECTLY INTO WITH DETAIL FOR A \C UNIT MOUNTING. PRIMER PERFORATED VENT CAP 12" FROM BOTTOM OF HIGHEST DRAIN PAN OR RISER VALVE CUT OFF SEE SPECIFIATIONS VALVE FOR PIPING MATERIAL. TRAP PRIMER CLEAN -OUT DRAIN PAN FLOOR DRAIN TRAP VALVE, ANCHOR TO PLUG CONNECTION WALL, SEE SPECS. PRIMER DISTRIBUTION ��� t 12' TEE UNION UNITS, ANCHOR TO WALL r SEE FLOOR PLANS FOR NUMBER OF LINES REQ'D. PIPING ROUTED ~ H TEE WITHIN WALL , , MINIMUM FULL RUN TO P -TRAP 1�2 = CONNECTION SIZE ON FLOOR DRAIN. FINISHED FLOOR a X J � UNI N ELBOW FLOOR SLAB BOTTOM ALL PIPING BELOW SLAB SHALL BE SOFT COPPER TYPE "K" AND RUN WITHIN PVC SLEEVE. NO FITTINGS PERMITTED BELOW SLAB. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. TRAP PRIMER DISTRIBUTION SINK OR LAVATORY INSTANT. E WATER HE/ MOUNTED VIN rrHLL FINISHED FLOOR VLINION /Z' HW AND CW LINES TO 'IXTURE TRIM ,z LLD WATER SUPPLY LINE W/ SUPPLY STOP. NOTE: I. PROVIDE WITH JUNCTION BOX, DISCONNECT AND WIRING AS REQUIRED. �IINSTANTANEOUS WATER HEATER I. �— PIPE SUPPORT TURN PIPE DOWN AT NEAREST CONDENSATE LDRAIN, WITH MIN OF I -INCH AIR GAP UNLESS SHOWN OTHERWISE ON PLANS, SEE PLUMBING PLANS FOR CONTINUATION. NOTE: 1. CONDENSATE TRAPS SHALL BE MADE UP OF UNIONS IN EACH SIDE OF TRAP, AND SHALL BE COMPLETELY REMOVABLE FOR CLEANING. CONTRACTOR SHALL DEMONSTRATE TRAP REMOVAL PRIOR TO FINAL ACCEPTANCE. 2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. COOLING COIL CONDENSATE DRAIN LAVATORY OR SINK FAUCET MAXLINE VALVE —,, HOT WATER VALVE VALVE TANK, HEATER, TEMPERED ETC. HOT SUPPLY ON MAIN HOT SUPPLY COLD SUPPLY NOTES: I. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. SET TEMPERATURE TO 110^ MAXIMUM PER FBC. MIXING VALVE PIPING AT FAUCETS I_ FLOOR DRAIN GRATE- /--- FINISH FLOOR EXISTING SLAB FLOOR DRAIN BODY PROVIDE NEW CONCRETE TO MATCH EXISTING FLOOR FLASHING MEMBRANE (SECTION 07XXX) REMOVE EXISTING CONCRETE TO RECEIVE FLASHING CLAMP — FIRESTOP SEALANT (SECTION 07270) CORE HOLE TO RECEIVE DRAIN BODY FLOOR DRAIN IN EXISTING SLAB [jil ARRAY healthcgre facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Boca Raton, FL 33487 t:561.995.1700 f:561.995.1701 firm license number www.arrayhfs.corn AA26000880 SEAL: CONSULTANTS: f'. M o rs w IT EOF Smith S eckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr-itic.com Finn Certification - EB- 0000857 Michael A. Steward PE - 65701 John E. Moulder PE - 33200 SSR JOB # 1232003.0 OWNER: BAPTIST HEALTH HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: Info Desk and Coffee Shop ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 1 BID AND PERMIT SET Lo7 -30 -12 N0. DESCRIPTION DATE REVISIONS /ISSUES SHEET TITLE: PLUMBING DETAILS DRAWN: FL CHECKED- CON/REF No. 00000 PROJECT No. 3601 DATE: 07/30112 SCALE: As indicated SHEET NO. P5.1 Tnir irurnenl cupyrij °'.L9d ui r�.ui2n� ;�ai;e :Cy' ,,I 'ITAY;ir'l licenscj `o' use In the titled Isroj�,ct er'd,; ep,cd,rticr nr u>e of this JCCAI[r °nt withon vr7en I rrri sr;n )I ARM" is 11 :mil 1,111 he grn: :uln;l .1nl l 7ho 11% CJCOPYRIGHT- 2012 ARRAY HFS