Loading...
12-939-040C 0 I W 1 2 3 I prl s GENERAL NOTES-. n II 5 I I J DEMOLITION AND INSTALLATION OF PIPING, FIXTURES, EQUIPMENT, ETC UNLESS NOTED OTHERWISE ON ARCH. DRAWINGS. — ----------- 1 - - - - -I DEMOL T ON ANDNEWWORKSHOWN PATCH WITH SIMILAR TO MATCH EXISTING. SEE 2. THE HOSPITAL IS OPEN 24 HOURS A DAY, 7 DAYS A WEEK. THE CONTRACTOR SHALL HAVE ARCH. DRAWINGS. 5 6 EXIST SAN RISER TO REMAIN I UNDERGROUND PLAN -NEW CONSTRUCTION - PLUMBING Op R" 2" 4 81 2 2' I. CONTRACTOR SHALL PATCH WALLS, FLOORS, CEILINGS AND LANDSCAPING TO MATCH EXISTING FINISHES FOR I I J DEMOLITION AND INSTALLATION OF PIPING, FIXTURES, EQUIPMENT, ETC UNLESS NOTED OTHERWISE ON ARCH. DRAWINGS. — ----------- 1 - - - - -I 6 EXIST SAN RISER TO REMAIN I UNDERGROUND PLAN -NEW CONSTRUCTION - PLUMBING Op R" 2" 4 81 2 2' I. CONTRACTOR SHALL PATCH WALLS, FLOORS, CEILINGS AND LANDSCAPING TO MATCH EXISTING FINISHES FOR 8. PIPING SHOWN IS ROUTED BELOW SLAB UNLESS NOTED OTHERWISE. DEMOLITION AND INSTALLATION OF PIPING, FIXTURES, EQUIPMENT, ETC UNLESS NOTED OTHERWISE ON ARCH. DRAWINGS. — S CONCRETE 9. SHALL SAW U REQUIRED TO ACCOMMODATE DEMOL T ON ANDNEWWORKSHOWN PATCH WITH SIMILAR TO MATCH EXISTING. SEE 2. THE HOSPITAL IS OPEN 24 HOURS A DAY, 7 DAYS A WEEK. THE CONTRACTOR SHALL HAVE ARCH. DRAWINGS. TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: KEYED NOTES- A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. �1 CONNECT 4" SANITARY LINE TO EXISTING 4' LINE BELOW SLAB. CONTRACTOR SHALL VERIFY IN FIELD EXACT SIZE, LOCATION AND INVERT ELEVATION. C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. D. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. CONTRACTOR SHALL LOCATE ALL NEW VALVES AT ACCESSIBLE LOCATIONS. PROVIDE ACCESS PANELS, AS REQUIRED, FOR VALVES LOCATED ABOVE HARD CEILINGS. 5. ALL WASTE AND CONDENSATE PIPING 2' & LESS TO BE SLOPED 0 1 /4 " /FT. ALL WASTE AND CONDENSATE PIPING 21/2' & LARGER TO BE SLOPED IQ Y8' /FT. 6. WORK MAY NOT BE LIMITED TO SCOPE OF WORK OR PHASING AREAS INDICATED, BUT ALSO MAY INCLUDE WORK OUTSIDE OF THE SCOPE OF WORK OR PHASING AREAS AS INDICATED BY CONTRACT DOCUMENTS. 7. CONTRACTOR SHALL FIELD VERIFY WITH HOSPITAL LOCATION OF EXISTING SERVICE VALVES FOR SHUTDOWN OF CW. COORDINATE TIMING, DURATION AND AREA AFFECTED BY SHUTDOWN WITH HOSPITAL. 7 NEW CONSTRUCTION LEGEND SYMBOL DESCRIPTION EXISTING TO REMAIN — NEW CONSTRUCTION CONNECT TO EXIST. AT THIS POINT ARRAY healthcare facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Boca Raton, FL 33487 t :561.995.1700 f:561.995.1701 firm license number www.arrayhfs.com AA26000880 SEAL: s ,CEN q O F MAL w '� 'IIi11Y 11� a o 111a1i11 CONSULTANTS: ,r Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Certification - EB- 0000857 Michael A. Steward PE - 65701 John E. Moulder PE - 33200 SSR JOB # 1232003.0 OWNER: BAPTIST HEALTH HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: Info Desk and Coffee Shop ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 1 BID AND PERMIT SET 07 -30 -12 NO. DESCRIPTION DATE REVISIONS/ISSUES SHEET TITLE: UNDERGROUND PLAN NEW CONSTRUCTION PLUMBING DRAWN: FL CHECKED: CON /REF No. 00000 PROJECT No. 3601 DATE: 07/30/12 SCALE: As indicated SHEET NO. P2.0 'WAY (id licensed P,, use- In the titlsd F:mjact anl.- _yea rd_icfi -r ar u-'? of thi- kcurn:,nt pith„ i , it i =n 1)?(rr Ii )I hf R A h� �' r+ ill , +.al :r d r,ill pr��•r =.,ail, t ri ki -hr I'la (C)COPYRIGHT - 2012 ARRAY HFS