12-939-033E
0
7
W1
J
LL
rt
3
0
"MAIN A/S DRAIN
INE FLOOR TO FLOOR
RISER CLAMP
ELEVATION
5
A/S ZONE DRAIN LINE
A/S DRAIN VALVE
INSPECTOR TEST
CONNNECTION
TEST VALVE 1 "
SITE GLASS 1"
JNION WITH ORIFICE
;ONNECTION TO MAIN
VS DRAIN LINE
TERMINATE A/S DRAIN
-INE TO EXTERIOR 18"
N.F.G. SEE SECTION.
SCUTCHEON
GROUND FLOOR
NOTE:
SINGLE A/S ZONE PIPE
ARRANGEMENT WITH A
CONTINUOUS MAIN A/S DRAIN
LINE,AND TERMINATION ON
GROUND FLOOR WITH EXPOSED
PIPING..
0
"1AIN A/S DRAIN
INE FLOOR TO FLOOR
;ISER CLAMP
S ZONE DRAIN LINE
ELEVATION
NOTE:
1. TYPICAL A/S DRAIN LINE TERMINATION TO EXTERIOR.
2. VALVES TO BE MOUNTED AT A MAXIMUM OF 5' -0" A.F.F.
IS DRAIN VALVE
JSPECTOR TEST
:ONNNECTION
TEST VALVE I"
;ITE GLASS 1"
INION WITH ORIFICE
;ONNECTION TO MAIN
JS DRAIN LINE
ISER CLAMP
IPPER FLOOR
NOTE:
SINGLE A/S ZONE PIPE
ARRANGEMENT WITH A
CONTINUOUS MAIN A/S
DRAIN LINE FLOOR TO
FLOOR AND EXPOSED
PIPES.
EXISTING A/S DRAIN AND TEST CONNECTION DETAIL
"A" DIMENSION, MINIMUM DIA
"B" (INCHES)
ADJUSTIBLE
CLEVIS HANGER
FOR PIPING 4" AND LARGER
GRINNELL FIG #260
---A
SIDE JOIST ATTACHMENT
OR
SIDE JOIST ADJUSTABLE
HANGER
NOTE:
HANGER ROD DIAMETER IS THE MINIMUM
SIZE PER NFPA. HANGER ROD DIAMETER
SHALL BE THE DIAMETER APPROVED FOR
USE WITH THE HANGER ASSEMBLY.
_ "A" DIMENSION,
MINIMUM DIA. v
- b
PHILLIPS CONCRETE
FASTENER I.T.T. GRINJON
(RED HEAD) TO BE UNEW CONSTRUCTION. HILTIKWIK BOLT, ZINC METAL EXPANSION ANEXISTING CONSTRUCTI
(SEE SPECIFICATIONS).
ADJUSTIBLE
SWIVEL RING HANGER
FOR PIPING 3" AND SMALLER
GRINNELL FIG #69
CENTER I —BEAM CLAMP
U AI\ICCDC
"A" DIMENSION,
MINIMUN DIA.(INCHES)
THREADED ROD
SIZE, CUT TO
LENGTH
SELF DRILLING CONCRETE WEDGE ANCHOR
TOP BEAM CLAMP
HANGER SPACING
1. 1" AND 11/4' DIA. STEEL PIPE: MAXIMUM 12 FT. SPACING.
2. 1" THRU 3" DIA. THREADED LIGHTWALL PIPE: MAX. 12 FT. SPACING
3. 11,2" AND LARGER DIA. STEEL PIPE: MAXIMUM 15 FT. SPACING.
4. ALL PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH
NFPA -13. EACH SECTION OF PIPE SHALL HAVE NO LESS
THAN ONE HANGER. ARMOVERS EXCEEDING 1 FT. SHALL HAVE
A HANGER.
5. PROVIDE PIPE CLAMP AT EACH FLOOR FOR RISERS
PENETRATING FLOORS.
6. TRAPEZE HANGERS SHALL NOT BE USED.
7. ALL HANGERS SHALL BE U.L. LISTED.
8. ALL EXTERIOR HANGERS SHALL BE STAINLESS STEEL INCLUDING
CLAMPS,THREADED RODS, NUTS & BOLTS.
9. ALL INTERIOR HANGERS SHALL BE GALVANIZED INCLUDING
CLAMPS.THREADED RODS, NUTS & BOLTS.
PIPE
SIZE
A
B
PIPE
SIZE
A
B
1
3/8
1/8
4
3/8
1/4
1
3/8
1/8
6
-T-/-2'-1/4
1
3/8
1/8
8
1/2"
174
2
3/8
1/4
10
5/8
1/4
2/
3/8
1/4
12
5/
1/4
3
3/8
1/4
HANGER ROD SCHEDULE
N.T.S
II■1]:i�7111111111011aa _111 0
I" X 1/2" REDUCER
CONCEALED
SPRINKLER HEAD
rA
SECTION
PIPE HANGER DETAIL TYPICAL SPRINKLER HEAD
DROP (RETURN BEND) DETAIL
4J':S
} s (ta'Mi %'ate
b3R ICf x ._t ll.
'ERIOR WALL
ARCH. DWG.
33 DRAIN LINE
SLEEVE
UTHEON
EADED OUTLET
i ELBOW
A.F.G.
NCRETE
LASH BLOCK
MINIMUM ONE HANGER ON
ARMOVERS 12" OR MORE
IN LENGTH
I" CLOSE NIPPLE
BRANCH LINE
CEILING
-j! ARRAY
he2!ihca re facilities solutions
6800 Broken Sound Boulevard NW
Suite 125
Boca Raton, FL 33487
t:561.995.1700
f:561.995.1701
www,arrayhfs.com
SEAL:
firm license number
AA26000880
CONSULTANTS:
Smith
Seckman
Reid, Inc.
600 West Hillsboro, Suite 300
Deerfield Beach, FL 33441
(954) 421 -1260
FAX: (954) 421 -1466
www.ssr- inc.com
Firm Certification - EB- 0000857
Michael A. Steward PE - 65701
John E. Moulder PE - 33200
SSR JOB # 1232003.0
OWNER:
BAPTIST HEALTH
HOSPITAL:
SOUTH MIAMI
HOSPITAL
PROD ECT:
Info Desk and Coffee
Shop
ADDRESS:
6200 Southwest 73rd Street
South Miami, FL 33143
1 BID AND PERMIT SET 07 -30 -12
NO. DESCRIPTION DATE
REVISIONS /ISSUES
SHEET TITLE:
FIRE PROTECTION
D ETAI LS
DRAWN: FL CHECKED :'
CON /REF No. 00000
PROJECT No. 3601
DATE: 07/30/12 SCALE: As indicated
SHEET NO.
FP5.1
This J�aiment r �t cep >yri� [ n .�:a.�d ui:���_unan ?rdie ;r.v ,I Nf�fiA'( Ur_1
lican � ror use in t'ne titl d 1rj5�',h �nl �'a�od.rctlar cr u" �t this d�scwneni
wi:Y� 1 miri_n �..rrh ?ico it ,;P6'A's i ill �:al :ci hill Pr pi � ':ulul .rilnr hr Ire,
COPYRIGHT - 2012 ARRAY HFS