12-939-032E 0 C 1 a J 1 2 3 El FIRST FLOOR PLAN -NEW CONSTRUCTION -FIRE PROTECTION M I GENERAL NOTES: I. CONTRACTOR SHALL PHASE WORK AS DIRECTED BY ARCHITECTURAL DRAWINGS AND OWNER. 2. CONTRACTOR SHALL PATCH WALLS, FLOORS, AND CEILINGS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF FIRE PROTECTION SYSTEMS. COORDINATE WITH ARCHITECTURAL DRAWINGS. 3. THE HOSPITAL IS OPEN 24 HOURS A DAY, 7 DAYS A WEEK. THE CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. D. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. WHERE FEASIBLE INSTALL NEW MAINS PRIOR TO DEMOLITION OF EXISTING. 4. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 5. PIPING SHOWN TO BE REMOVED IS NOT TO BE CAPPED AND ABANDONED. 6. CONTRACTOR SHALL COORDINATE TIMING, DURATION AND AREAS AFFECTED BY SHUTDOWNS WITH HOSPITAL IN ORDER TO FACILITATE REQUIRED FIRE WATCH. 7. CONTRACTOR SHALL COORDINATE NEW SPRINKLER HEAD LOCATIONS WITH CEILING GRID, CEILING MOUNTED DEVICES (LIGHTS, DIFFUSERS, SMOKE DETECTORS, ETC.) AND OBSTRUCTIONS TO SPRINKLER THROW (SOFFITS, PRIVACY CURTAINS, ETC.) PER NFPA 13. KEYED NOTES.- 5 „P iw�umi F OREMOVE EXISTING SPRINKLER HEAD AND EXTEND EXISTING I" BRANCH PIPING TO NEW SPRINKLER HEAD. COORDINATE NEW LOCATION WITH ALL CEILING MOUNTED DEVICES. (LIGHTS, DIFFUSERS, SMOKE DETECTORS, ETC.) ORAISE EXISTING A/S PIPING AS REQUIRED TO FACILITATE THE INSTALLATION OF THE NEW ABOVE CEILING SYSTEMS.) CONTRACTOR SHALL COORDINATE LOCATION OF THE AREA CONTROL VALVE. " <s i ty id rr 1 r < Ii Av ?� X 7 PROVIDE QUICK RESPONSE CONCEALED SPRINKLERS WITH WHITE FINISH IN ALL SPACES UNLESS OTHERWISE NOTED PER LIGHT HAZARD OCCUPANCY. NEW CONSTRUCTION LEGEND SYMBOL DESCRIPTION DATE EXISTING TO REMAIN NEW CONSTRUCTION -~--+� CONNECT TO EXIST. AT THIS POINT ijil ARRAY hea ►thcare facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Boca Raton, FL 33487 t:561.995.1700 f:561.995.1701 firm license number www.arrayhfs.com AA26000880 SEAL: CONSULTANTS: y m o OR �b/ �e•• i l t t����� Smith WAIIi.- Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Certification - EB- 0000857 Michael A. Steward PE - 65701 John E. Moulder PE - 33200 SSR JOB t# 1232003.0 OWNER: BAPTIST HEALTH HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: Info Desk and Coffee Shop ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 1 BID AND PERMIT SET 07 -30 -12 N0. DESCRIPTION DATE REVISIONS /ISSUES SHEET TITLE: FIRST FLOOR PLAN NEW CONSTRUCTION FIRE PROTECTION DRAWN: FL CHECKED: CON /REF No. 00000 PROJECT No. 3601 DATE: 07/30/12 SCALE: As indicated SHEET NO. FP2.1 This i s_ur ent rnpyrig� r ect� <I In n.Ir-n _ si;? r.7 of AhF;A'( arJ llc:ars d fer use in the tltlnd Fr t,--t onl %. �eorod_I ti er u,, A this d"�cum -.nt 7dthX1 Ii!I n i.(rrr-.,rm )f ,l TAY r+ ill. ,il `Ir -1 ,ill I uIol _rrl.l Tl'r IIt- Cq)COPYRIGHT-2012 ARRAY HFS