12-939-019SECTION 092900 - GYPSUM BOARD
1.1 THIS SECTION INCLUDES THE FOLLOWING:
A- INTERIOR GYPSUM BOARD
B. TILE BACKING PANELS.
1.2 QUALITY ASSURANCE
A. FIRE - RESISTANCE -RATED ASSEMBLIES: FOR FIRE - RESISTANCE -RATED ASSEMBLIES, PROVIDE MATERIALS AND CONSTRUCTION IDENTICAL TO
THOSE TESTED IN ASSEMBLY INDICATED ACCORDING TO ASTM E 119 BY AN INDEPENDENT TESTING AGENCY.
B. STC -RATED ASSEMBLIES: FOR STC -RATED ASSEMBLIES, PROVIDE MATERIALS AND CONSTRUCTION IDENTICAL TO THOSE TESTED IN ASSEMBLY
INDICATED ACCORDING TO ASTM E 90 AND CLASSIFIED ACCORDING TO ASTM E 413 BY AN INDEPENDENT TESTING AGENCY.
1.3 INTERIOR GYPSUM BOARD
A. GENERAL: COMPLYING NTH ASTM C 36/C 36M OR ASTM C 1396/C 1396M, AS APPLICABLE TO TYPE OF GYPSUM BOARD INDICATED AND WHICHEVER
E IS MORE STRINGENT.
1. TYPE X: THICKNESS: 518 INCH (15.9 MM). LONG EDGES: TAPERED.
2. FLEXIBLE TYPE: MANUFACTURED TO BEND TO FIT RADII AND TO BE MORE FLEXIBLE THAN STANDARD REGULAR -TYPE GYPSUM BOARD OF
SAME THICKNESS.
a. THICKNESS: 114 INCH (6.4 MM). LONG EDGES: TAPERED.
3. CEILING TYPE: MANUFACTURED TO HAVE MORE SAG RESISTANCE THAN REGULAR -TYPE GYPSUM BOARD.
a. THICKNESS: 112 INCH (12.7 MM). LONG EDGES: TAPERED.
1.4 AUXILIARY MATERIALS
A. GENERAL: PROVIDE AUXILIARY MATERIALS THAT COMPLY WITH REFERENCED INSTALLATION STANDARDS AND MANUFACTURER'S WRITTEN
RECOMMENDATIONS.
B. STEEL DRILL SCREWS: ASTM C 1002, UNLESS OTHERWISE INDICATED.
1. USE SCREWS COMPLYING WITH ASTM C 954 FOR FASTENING PANELS TO STEEL MEMBERS FROM 0.033 TO 0.112 INCH (0.84 TO 2.84 MM)
THICK.
2. FOR FASTENING CEMENTITIOUS BACKER UNITS, USE SCREWS OF TYPE AND SIZE RECOMMENDED BY PANEL MANUFACTURER.
1.5 APPLYING AND FINISHING PANELS, GENERAL
A. COMPLY WI TH ASTM C 840.
B. EXAMINE PANELS BEFORE INSTALLATION. REJECT PANELS THATARE WET, MOISTURE DAMAGED, AND MOLD DAMAGED.
C. ISOLATE PERIMETER OF GYPSUM BOARD APPLIED TO NON -LOAD- BEARING PARTITIONS AT STRUCTURAL ABUTMENTS, EXCEPT FLOORS.
PROVIDE 114- TO 112 -INCH- (6.4- TO 12.7 -MM -) WIDE SPACES AT THESE LOCATIONS, AND TRIM EDGES WITH EDGE TRIM WHERE EDGES OF PANELS
ARE EXPOSED. SEAL JOINTS BETWEEN EDGES AND ABUTTING STRUCTURAL SURFACES WITH ACOUSTICAL SEALANT.
1.6 APPLYING INTERIOR GYPSUM BOARD
A. INSTALL INTERIOR GYPSUM BOARD IN THE FOLLOWING LOCATIONS:
1. TYPE X: VERTICAL SURFACES, UNLESS OTHERWISE INDICATED.
2. FLEXIBLE TYPE: APPLY IN DOUBLE LAYER AT CURVED ASSEMBLIES.
3. CEILING TYPE: CEILING SURFACES AND SOFFIT.
1.7 INSTALLING TRIM ACCESSORIES
A. GENERAL: FOR TRIM WITH BACK FLANGES INTENDED FOR FASTENERS, ATTACH TO FRAMING WITH SAME FASTENERS USED FOR PANELS.
OTHERWISE, ATTACH TRIM ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS.
D B. CONTROL JOINTS: INSTALL CONTROL JOINTS ACCORDING TO ASTM C 840 AND IN SPECIFIC LOCATIONS APPROVED BY ARCHITECT FOR VISUAL
EFFECT.
C. INTERIOR TRIM: INSTALL IN THE FOLLOWING LOCATIONS:
1. CORNERBEAD: USE AT OUTSIDE CORNERS, UNLESS OTHERWISE INDICATED,
2. BULLNOSE BEAD: USE AT OUTSIDE CORNERS
3. LC -BEAD: USE AT EXPOSED PANEL EDGES
4. L -BEAD: USE WHERE INDICATED
5. U -BEAD: USE WHERE INDICATED
6. CURVED -EDGE CORNERBEAD: USE AT CURVED OPENINGS.
1.8 FINISHING GYPSUM BOARD
A. GYPSUM BOARD FINISH LEVELS: FINISH PANELS TO LEVELS INDICATED BELOW:
1. LEVEL 1: CEILING PLENUM AREAS, CONCEALED AREAS, AND WHERE INDICATED,
2. LEVEL 2: PANELS THAT ARE SUBSTRATE FOR TILE
3. LEVEL 3: ABOVE CEILING ON FIRE RATED WALLS
4. LEVEL 4: AT PANEL SURFACES THAT WILL BE EXPOSED TO VIEW, UNLESS OTHERWISE INDICATED
a. PRIMERAND ITS APPLICATION TO SURFACES ARE SPECIFIED IN OTHER DIVISION 09 SECTIONS.
5. LEVEL 5: ALL PANEL SURFACE TO RECEIVING HIGH AND SEMIGLOSS PAINT
END OF SECTION 092900
SECTION 093000 - CERAMIC TILE
1.1 THIS SECTION INCLUDES:
A. CERAMIC MOSAIC AND PORCELAIN WALL TILE.
B. SOLID POLYMER THRESHOLDS INSTALLED AS PART OF TILE INSTALLATIONS.
C. WATERPROOF MEMBRANE FOR THIN -SET TILE INSTALLATIONS.
D. CRACK- SUPPRESSION MEMBRANE FOR THIN -SET TILE INSTALLATIONS.
E. CEMENTITIOUS BACKER UNITS INSTALLED AS PART OF TILE INSTALLATIONS.
F. METAL EDGE STRIPS INSTALLED AS PART OF TILE INSTALLATIONS.
C12 QUALITY ASSURANCE
A. MOCKUPS FOR EACH FORM OF CONSTRUCTION.
1.3 TILE PRODUCTS
A. ANSI CERAMIC TILE STANDARD: PROVIDE STANDARD GRADE TILE THAT COMPLIES WITH ANSI A137.1 FOR TYPES, COMPOSITIONS, AND OTHER
CHARACTERISTICS INDICATED.
B. SEE FINISH DRAWING FOR MANUFACTURER, STYLE AND COLOR.
1.4 SETTING MATERIALS
A. PORTLAND CEMENT MORTAR (THICKSET) INSTALLATION MATERIALS: ANSI A108.02.
B. DRY -SET PORTLAND CEMENT MORTAR (THIN SET): ANSI Al 18.1.
C. WALL TILE SHALL BE INSTALLED BY THIN -SET METHOD VV242 AND MORTAR METHOD VV222 AS DEFINED BY THE TILE COUNCIL OF AMERICA AND
INSTALLATION SHALL FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR SETTING AND GROUTING TILES,
D. FLOOR TILE SHALL BE INSTALLED BY DRY -SET MORTAR INSTALLATION METHOD F113, AS DEFINED BY THE TILE COUNCIL OF AMERICA.
E. PREMIUM- GRADE, WATER-CLEANABLE, 100%-SOLIDS, HIGH - STRENGTH EPDXY MORTAR AND CHEMICAL- RESISTANT NONSAGGING GROUT
SYSTEM: ANSI A118.3.
1.5 MATERIALS
A. PORCELAIN WALL TILE TRIM SHAPES: COVED BASE, BULLNOSE CAP, BULLNOSE EXTERNAL CORNER.
1. TILE STYLES, COLORS, PATTERNS AND ACCENT BORDERS SHALL BE AS SPECIFIED IN THE INTERIOR FINISH SCHEDULE AND /OR AS
SHOWN ON THE DRAWINGS.
B. CERAMIC MOSAIC TRIM SHAPES: COVED BASE, BEAD ( BULLNOSE) CAP, BEAD ( BULLNOSE) EXTERNAL CORNER, COVED INTERNAL CORNER.
1. TILE STYLES, COLORS, PATTERNS AND ACCENT BORDERS SHALL BE AS SPECIFIED IN THE INTERIOR FINISH SCHEDULE AND /GRAS
SHOWN ON THE DRAWINGS.
C. THRESHOLDS: MARBLE OR SOLID POLYMER.
D. WATERPROOFING: UNREINFORCED, FLUID- APPLIED RUBBER.
E. CRACK - SUPPRESSION MEMBRANES: PVC SHEET.
F. ELASTOMERIC SEALANTS: ONE -PART, MILDEW - RESISTANT SILICONE.
1.6 INSTALLATION
A. COMPLY WITH TCA'S "HANDBOOK FORCERAMIC TILE INSTALLATION" FOR TCA INSTALLATION METHODS SPECIFIED IN TILE INSTALLATION
B SCHEDULES. COMPLY VrATH PARTS OF THE ANSI A108 SERIES "SPECIFICATIONS FOR INSTALLATION OF CERAMIC TILE" THAT ARE REFERENCED IN
TCA INSTALLATION METHODS, SPECIFIED IN TILE INSTALLATION SCHEDULES, AND APPLY TO TYPES OF SETTING AND GROUTING MATERIALS USED.
END OF SECTION 093000
18xij�[ �P►C IsyfYl�:7[�►�I.�:1:1 »17�:l�lgb9
PART 1 -GENERAL
1.1 SUMMARY
A. SECTION INCLUDES SHOP- FABRICATED, FABRIC - WRAPPED WALL PANELS.
1.2 ACTION SUBMITTALS
A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.
B. SHOP DRAWINGS: FOR FABRIC - WRAPPED WALL PANELS. INCLUDE MOUNTING DEVICES AND DETAILS.
C. SAMPLES: FOR EACH EXPOSED PRODUCT AND FOR EACH COLOR AND TEXTURE SPECIFIED.
1.3 CLOSEOUT SUBMITTALS
A. MAINTENANCE DATA.
1.4 QUALITY ASSURANCE
A. FIRE - TEST - RESPONSE CHARACTERISTICS: PROVIDE FABRIC - WRAPPED WALL PANELS MEETING THE FOLLOWING AS DETERMINED BY TESTING
IDENTICAL PRODUCTS BY UL OR ANOTHER TESTING AND INSPECTING AGENCY ACCEPTABLE TOAUTHORITIES HAVING JURISDICTION:
1. SURFACE- BURNING CHARACTERISTICS: AS DETERMINED BY TESTING PER ASTM E 84.
A. FLAME - SPREAD INDEX: 25 OR LESS.
B. SMOKE - DEVELOPED INDEX: 50 OR LESS.
2. FIRE GROWTH CONTRIBUTION: MEETING ACCEPTANCE CRITERIA OF LOCAL CODE AND AUTHORITIES HAVING JURISDICTION WHEN
TESTED ACCORDING TO NFPA 286.
PART 2- PRODUCTS
2.1 FABRIC - WRAPPED WALL PANELS
A. GENERAL REQUIREMENTS FOR FABRIC - WRAPPED WALL PANELS: PANELS SHALL COMPLY WITH THE TESTING AND PRODUCT REQUIREMENTS
OF THE CALIFORNIA DEPARTMENT OF HEALTH SERVICES - STANDARD PRACTICE FOR THE TESTING OF VOLATILE ORGANIC EMISSIONS FROM
VARIOUS SOURCES USING SMALL -SCALE ENVIRONMENTAL CHAMBERS."
B. FABRIC - WRAPPED WALL PANEL: MANUFACTURER'S STANDARD PANEL CONSTRUCTION CONSISTING OF FACING MATERIAL STRETCHED
OVER FRONT FACE OF EDGE - FRAMED CORE AND BONDED OR ATTACHED TO EDGES AND BACK OF FRAME.
1. MOUNTING: EDGE MOUNTED WITH SPLINES SECURED TO SUBSTRATE.
2. MOUNTING: BACK MOUNTED NTH MANUFACTURER'S STANDARD ADHESIVE.
3. CORE: MANUFACTURER'S STANDARD.
C. CORE -FACE LAYER: MANUFACTURER'S STANDARD TACKABLE, IMPACT - RESISTANT, HIGH - DENSITY BOARD.
1. CORE OVERLAY: POLYESTER BATTING 112 INCH (13 MM) THICK.
2. EDGE CONSTRUCTION. MANUFACTURER'S STANDARD CHEMICALLY HARDENED CORE WITH NO FRAME.
3. EDGE PROFILE: EASED (SMALL RADIUS).
4. CORNER DETAIL IN ELEVATION. SQUARE NTH CONTINUOUS EDGE PROFILE INDICATED.
5. REVEALS BETWEEN PANELS: FLUSH.
6. FACING MATERIAL: TO BE SELECTED BYN OWNER.
2.2 MATERIALS
A. CORE MATERIALS:MANUFACTURER'S STANDARD.
1. MINERAL -FIBER BOARD: MAXIMUM FLAME- SPREAD AND SMOKE - DEVELOPED INDEXES OF 25 AND 10, RESPECTIVELY.
2. LINING MATERIAL: MANUFACTURER'S STANDARD FABRIC FOR EACH USE INDICATED.
B. MOUNTING DEVICES: CONCEALED ON BACK OF PANEL, RECOMMENDED BY MANUFACTURER TO SUPPORT WEIGHT OF PANEL, AND AS
FOLLOWS:
1. ADHESIVES: AS RECOMMENDED BY FABRIC - WRAPPED, WALL PANEL MANUFACTURER.
2.3 FABRICATION
A. GENERAL: USE MANUFACTURER'S STANDARD CONSTRUCTION EXCEPT AS OTHERWISE INDICATED; WITH FACING MATERIAL APPLIED TO
FACE, EDGES, AND BACK BORDER OF DIMENSIONALLY STABLE CORE; AND NTH RIGID EDGES TO REINFORCE PANEL PERIMETER AGAINST
WARPAGE AND DAMAGE.
B. CORE -FACE LAYER[ AND CORE OVERLAY]: EVENLY STRETCHED OVER CORE FACE AND EDGES AND SECURELY ATTACHED TO CORE, FREE
FROM PUCKERS, RIPPLES, WRINKLES, OR SAGS.
C. FACING MATERIAL[AND LINING MATERIAL]: APPLY FABRIC FULLY COVERING VISIBLE SURFACES OF PANEL; WITH MATERIAL STRETCHED
STRAIGHT, ON THE GRAIN, TIGHT, SQUARE, AND FREE FROM PUCKERS, RIPPLES, WRINKLES, SAGS, BLISTERS, SEAMS, ADHESIVE, OR OTHER
VISIBLE DISTORTIONS OR FOREIGN MATTER.
1. FABRICS WITH DIRECTIONAL OR REPEATING PATTERNS OR DIRECTIONAL WEAVE: MARK FABRIC TOP AND ATTACH FABRIC IN SAME
DIRECTION SO PATTERN OR WEAVE MATCHES IN ADJACENT PANELS.
D. DIMENSIONAL TOLERANCES OF FINISHED PANELS: PLUS OR MINUS 1/16 INCH (1.6 MM).
PART 3 - EXECUTION
3.1 INSTALLATION
A. INSTALL FABRIC - WRAPPED WALL PANELS IN LOCATIONS INDICATED WITH VERTICAL SURFACES AND EDGES PLUMB, TOP EDGES LEVEL AND IN
ALIGNMENT VATH OTHER PANELS, FACES FLUSH, AND SCRIBED TO FIT ADJOINING WORK ACCURATELY AT BORDERS AND AT
PENETRATIONS.
B. COMPLY WITH FABRIC - WRAPPED, WALL PANEL MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLATION OF PANELS USING TYPE OF
MOUNTING DEVICES INDICATED. MOUNT PANELS SECURELY TO SUPPORTING SUBSTRATE.
C. ALIGN AND LEVEL FABRIC PATTERN AND GRAIN AMONG ADJACENT PANELS.
D. CLIP LOOSE THREADS; REMOVE PILLS AND EXTRANEOUS MATERIALS.
E. CLEAN PANELS ON COMPLETION OF INSTALLATION TO REMOVE DUSTAND OTHER FOREIGN MATERIALS ACCORDING TO MANUFACTURER'S
WRITTEN INSTRUCTIONS.
END OF SECTION 097723
5
SECTION 099123 - INTERIOR PAINTING
1.1 THIS SECTION INCLUDES SURFACE PREPARATION AND THE APPLICATION OF PAINT SYSTEMS ON THE FOLLOWING INTERIOR SUBSTRATES:
A. GYPSUM BOARD
C�
1.2 SAMPLES: FOR EACH COLOR AND TEXTURE REQUIRED. LABEL EACH SAMPLE WITH MANUFACTURER'S NAME, MATERIAL DESCRIPTION, COLOR, PATTERN, AND
DESIGNATION INDICATED ON DRAWINGS AND IN SCHEDULES.
A. DRAW DOWNS TO BE MINIMUM OF 6 INCH SQUARE SAMPLE
1.3 QUALITY ASSURANCE
A. MPI STANDARDS:
1. PRODUCTS: COMPLYING NTH MPI STANDARDS INDICATED AND LISTED IN "MPI APPROVED PRODUCTS LIST."
2. PREPARATION AND WORKMANSHIP: COMPLY WITH REQUIREMENTS IN "MPI ARCHITECTURAL PAINTING SPECIFICATION MANUAL" FOR PRODUCTS AND
PAINT SYSTEMS INDICATED.
1.4 MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, SEE FINISH DRAWINGS FOR COLOR AND LOCATION. PROVIDE PRODUCTS BY ONE OF THE
FOLLOWING:
A. BENJAMIN MOORE 8 CO.
B. DURON, INC.
C. ICI PAINTS.
D. M.A.B. PAINTS.
E. PPG ARCHITECTURAL FINISHES, INC.
F. SHERNN- WILLIAMS COMPANY (THE).
1.5 PAINT, GENERAL
A. VOC CONTENT OF FIELD - APPLIED INTERIOR PAINTS AND COATINGS: PROVIDE PRODUCTS THAT COMPLY NTH THE FOLLOWING LIMITS FOR VOC CONTENT,
EXCLUSIVE OF COLORANTS ADDED TO A TINT BASE, WHEN CALCULATED ACCORDING TO 40 CFE 59, SUBPART D (EPA METHOD 24); THESE REQUIREMENTS
DO NOT APPLY TO PAINTS AND COATINGS THAT RE APPLIED IN A FABRICATION OR FINISHING SHOP.
B. PRIMERS /SEALERS: INTERIOR LATEX PRIMER/SEALER: MPI #50.
C. METAL PRIMERS: RUST - INHIBITIVE PRIMER (WATER BASED): MPI #107.
D WOOD PRIMERS: INTERIOR LATEX -BASED WOOD PRIMER: MPI #39.
E. LATEX PAINTS: INSTITUTIONAL LOW- ODORrVOC LATEX (SEMI - GLOSS): MPI #147 (GLOSS LEVEL 5).
F. QUICK- DRYING ENAMELS: QUICK- DRYING ENAMEL (SEMI - GLOSS): MPI #81 (GLOSS LEVEL 5).
1.5 EXAMINE SUBSTRATES AND CONDITIONS, WITH APPLICATOR PRESENT, FOR COMPLIANCE NTH REQUIREMENTS FOR MAXIMUM MOISTURE CONTENT AND
OTHER CONDITIONS AFFECTING PERFORMANCE OF WORK.
1.6 PREPARATION
A. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS IN "MPI ARCHITECTURAL PAINTING SPECIFICATION MANUAL"
APPLICABLE TO SUBSTRATES INDICATED.
B. GALVANIZED -METAL SUBSTRATES: REMOVE GREASE AND OIL RESIDUE FROM GALVANIZED SHEET METAL FABRICATED FROM COIL STOCK BY MECHANICAL
METHODS TO PRODUCE CLEAN, LIGHTLY ETCHED SURFACES THAT PROMOTE ADHESION OF SUBSEQUENTLY APPLIED PAINTS.
C. GYPSUM BOARD SUBSTRATES: DO NOT BEGIN PAINT APPLICATION UNTIL FINISHING COMPOUND IS DRY AND SANDED SMOOTH AND COMPOUND DUST IS
REMOVED FOR THE SURFACE.
1.7 APPLICATION
A. APPLY PAINTS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS.
B TINT EACH UNDERCOAT A LIGHTER SHADE TO FACILITATE IDENTIFICATION OF EACH COAT IF MULTIPLE COATS OF SAME MATERIAL ARE TO BE APPLIED.
TINT UNDERCOATS TO MATCH COLOR OF TOPCOAT, BUT PROVIDE SUFFICIENT DIFFERENCE IN SHADE OF UNDERCOATS TO DISTINGUISH EACH SEPARATE
COAT.
C. PAINTING MECHANICAL AND ELECTRICAL WORK: PAINT ITEMS EXPOSED IN EQUIPMENT ROOMS AND OCCUPIED SPACES.
1.8 CLEANING AND PROTECTION
A. AFTER COMPLETING PAINT APPLICATION, CLEAN SPATTERED SURFACES. REMOVE SPATTERED PAINTS BY WASHING, SCRAPING, OR OTHER METHODS.
DO NOT SCRATCH OR DAMAGE ADJACENT FINISHED SURFACES.
B. PROTECT WORK OF OTHER TRADES AGAINST DAMAGE FROM PAINT APPLICATION. CORRECT DAMAGE TO WORK OF OTHER TRADES BY CLEANING,
REPAIRING, REPLACING, AND REFINISHING, AS APPROVED BY ARCHITECT, AND LEAVE IN AN UNDAMAGED CONDITION.
1.9 INTERIOR PAINTING SCHEDULE
A. GYPSUM BOARD SUBSTRATES:
1. INSTITUTIONAL LOW- ODORIVOC LATEX SYSTEM: MPI INT9.2M.
a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER.
b. INTERMEDIATE COAT: INSTITUTIONAL LOW- ODOR/VOC INTERIOR LATEX MATCHING TOPCOAT.
c. TOPCOAT: INSTITUTIONAL LOW- ODORNOC INTERIOR LATEX EGGSHELL FINISH
2. HIGH - PERFORMANCE ARCHITECTURAL LATEX SYSTEM: MPI INT9.213. (EPDXY PAINT USED ON PLUMBING WALLS OF TOILET ROOMS AND AS NOTED ON
DRAWINGS)
a. PRIME COAT: INTERIOR LATEX PRIMER/SEALER.
b. INTERMEDIATE COAT: HIGH - PERFORMANCE ARCHITECTURAL LATEX MATCHING TOPCOAT.
c. TOPCOAT: HIGH - PERFORMANCE ARCHITECTURAL LATEX EGGSHELL FINISH
Iqi :11Ir]I�9xilll[rt]►Db'�sylr�e]
7
i'T .-i t) F Uf ] -.I 'I'll I A IVI
033 DEPT.
=r.94i A R R A Y
t
healthcare facilities solutions
6800 Broken Sound Boulevard NW
Suite 125
Boca Raton, FL 33487
t: 561.995.1700
f: 561.995.1701
www.arrayhfs.com
SEAL:
firm license number
AA26000880
MARK D. TAUDIEN AR0011821
CONSULTANTS:
Smith Seckman Reid, Inc.
600 West Hillsboro Blvd., Suite 300
Deerfield Beach, FL 33441
1 11 i
BAPTIST HEALTH SOUTH
FLORIDA
HOSPITAL:
SOUTH MIAMI
HOSPITAL
PROJ ECT:
Info Desk [t Coffee Shop
ADDRESS:
6200 Southwest 73rd Street
South Miami, FL 33143
_ ------- - - - - --
1 BID AND PERMIT SET 07 -30 -12
NO. DESCRIPTION DATE
REVISIONS /ISSUES
SHEET TITLE:
SPECIFICATIONS
DRAWN: FL CHECKED: MDT
CON /REF No. 00000
PROJECT No. 3601
DATE: 07/30/2012 SCALE: 12" = V-o°
SHEET NO.
A803
Ihiis �:lorainent is a rapyright prnferled incliurnent rf ssrrice, properly of t \RRSY and
licaiv�d far usr in tha LiLI?d proj��l only_ Reprudu!!ian or !i,c of lhi; docurnant
,vilhoi.il wfflLen pNrrniasion aF'�RRA'f is illegal and v;ill b? prnannutr.l order file law.
<CiCOPYRIGHT - 2012 ARRAY HFS