12-939-016E
C
1 2 3 4 5 6
SECTION @ COFFEE SHOP - UPPER COUNTER
CLEAR SEAL
ASECTION THROUGH GLAZING JAMB
l } „_ „ - -- -
--- 2 -1 -0
41 /2"
- d fi
1/2" THICK TEMPERED GLASS
HARDWOOD FINISH STAINED TO
MATCH LAMINATE
1/2" F.R.T. PLYWOOD WITH LAMINATE FINISH
NOTE:
OPPOSITE END IS SIMILAR
2X F.R.T. WOOD FRAMING
FLUSH
D SURFACE OCOUNTERTOP OVER
'LYWOOD
D CORE EDGE TRIM
TIC LAMINATE SHELF WITH 314"
PLYWOOD CORE ON FULL
EXTENSION SLIDES
"LASTIC LAMINATE FACED PANEL
TRICAL BACK BOX
4 F.R.T. WOOD FRAMING
X 4" HARDWOOD BASE
[WOOD BLOCKING
SS -3
(SOLID SURFACE CAP)
2X F.R.T. WOOD FRAMING
TRASH
z
0
o w
w
N Z
0
PLASTIC LAMINATE
INTERIOR FINISH
CASEWORK @ TRASH UNIT
(D3;
11/2" _-- T�_0"
5112"
11/2', 11/2'
w "
T -0"
WOOD BLOCKING
SOLID SURFACE CAP
3 518" METAL STUD
GLASS TILE BACKSPLASH
r SOLID POLYMER EDGE BANDING
I I
I SOLID SURFACE BACKSPLASH
' SOLID SURFACE COUNTERTOP
WOOD BLOCKING
I =1
318" HEX HEAD BOLT WITH WALL
_TOGGLE FASTENED TO 6" W X 18
GAUGE GALVANIZED STEEL PLATE
SECURED TO A MINIMUM OF 3 STUDS
1
I
PLASTIC LAMINATE DOOR FACE
__ -(- 3 518" X 20 GAUGE METAL STUD
FRAMING @ 16" O.C. W/ 5/8"
GYPSUM WALL BOARD ON EACH
SIDE
I
TILE FLOOR
3 4" PLYWOOD WITH PLASTIC LAMINATE FINISH
SLID SURFACE EDGE BANDING
B3 SECTION @ COFFEE SHOP
em
(2) LAYERS 1/4" F.R.T.
PLYWOOD WITH PLASTIC
LAMINATE FINISH
1/2" LAMINATE FACED
REVEAL
SS -1
(SOLID SURFACE END CAP)
1/2" F.R.T. PLYWOOD WITH 2 X 3 F.R.T. WOOD
LAMINATE FINISH FRAMING @ 16 O.C.
SECTION -CAP DETAIL - DE
-- TAIL -END CAP
A2) -- _ _._ __ (A3� -;i -_ - - - -
`- 1112 -1 -0 1112 -1 -0
A4
A632B
I o
PLAN m SECTION
MOVABLE CAMERA PEDESTAL DETAIL
IliSMAl 111111 i
IDENTIFICATION OF PARTS NOTES
1. DRAWER FRONTS AND DOORS ARE CLOSED;
2. CABINETS AND SHELVING ARE OPEN -TYPE OR BEHIND CLEAR GLASS DOOR;
3. BOTTOMS OF CABINETS ARE SEEN 42" OR MORE ABOVE FINISHED FLOOR;
4. TOPS OF CABINETS ARE SEEN BELOW 78" ABOVE FINISHED FLOOR, OR ARE
VISIBLE FROM AN UPPER FLOOR OR STAIRCASE AFTER INSTALLATION,
5. PORTION OF CABINETS ARE VISIBLE AFTER FIXED APPLIANCES ARE INSTALL
6. FRONT EDGES OF CABINET BODY MEMBERS ARE VISIBLE OR SEEN THROUG
GAP GREATER THAN 1/8" WITH DOORS AND DRAWERS CLOSED.
SEMI - EXPOSED PARTS - SURFACES VISIBLE WHEN:
1. DRAWER AND DOORS ARE IN THE OPEN POSITION;
2. BOTTOMS OF CABINETS ARE BETWEEN 30" AND UP TO 42" ABOVE FINISHED
FLOOR.
3. ALL FRONT EDGES OF SHELVING BEHIND DOORS.
CONCEALED SURFACES - SURFACES ARE CONCEALED WHEN:
1. SURFACES ARE NOT VISIBLE AFTER INSTALLATION;
2. BOTTOMS OF CABINETS ARE LESS THAN 30" ABOVE FINISHED FLOOR;
3. TOPS OF CABINETS ARE OVER 78" ABOVE FINISHED FLOOR AND ARE NOT
VISIBLE FROM AN UPPER FLOOR OR STAIRCASE AFTER INSTALLATION.
4. STRETCHERS, BLOCKING AND /OR COMPONENTS ARE CONCEALED BY
7
CASEWORK NOTES
1. THESE NOTES ARE TYPICAL UNLESS OTHERWISE NOTED.
2. ALL CASEWORK TO BE BALANCED CONSTRUCTION.
3. ALL COUNTERTOPS WITH SINKS TO HAVE MARINE GRADE PLYWOOD
SUBSTRATE.
4. ALL EXPOSED AND SEMI EXPOSED PARTS, AS DETERMINED IN THE
"IDENTIFICATION OF PART NOTES" TO HAVE PLASTIC LAMINATE FINISH.
5. ALL SIX FACES OF ADJUSTABLE SHELVING TO HAVE PLASTIC LAMINATE FINISH.
6. ALLADJUSTABLE SHELVING TO MATCH CABINET DEPTH UNLESS OTHERWISE
NOTED.
7. ALL SHELVES TO BE 314" THICK MDF FOR SPANS UP TO a -0 ". ADD 314" X 1 -1/2"
SOLID LUMBER DROPPED EDGE FOR SPANS OVER 3' -0" USE.
8. ALL OPEN SPACE SIZES AND KNEE BRACES LOCATIONS TO BE VERIFIED WITH
EQUIPMENT TO BE INSTALLEDAND WITH ACTUAL ROOM DIMENSIONS.
9. PROVIDE SURFACE MOUNTED WALL BRACKET FOR COUNTERS WITH SPANS
GREATER THAN 4' -0" UNLESS NOTED OTHERWISE.
10. ALL PLASTIC LAMINATE JOINTS TO BE NOTED ON SHOP DRAWINGS.
11. 4" BACKSPLASH AND ENDSPLASH TYPICAL UNLESS OTHERWISE NOTED.
12. ALL FINISHED END PANELS AT VIALL CABINETS TO BE ONE CONTINUOUS PANEL
INCLUDING VALANCE.
13. ALL FINISHED END PANELS AT BASE CABINETS TO BE ONE CONTINUOUS PANEL
INCLUDING BASE.
14. ALL EXPOSED CORNERS OF COUNTERTOPS TO HAVE 1" RADIUS.
15. AT CUTOUTS AND "L" SHAPED COUNTERTOPS, ALL INSIDE CORNERS TO BE
SMOOTHLY ROUNDED WITH A MINIMUM CORNER RADIUS OF 1/2 ".
16. INSTALL GROMMETS IN COUNTER TOPS @ EACH PIECE OF OWNER FURNISHED
EQUIPMENT.
17. PULL SHOWN INDICATES POSITION ONLY SEE CODE FOR HINGE SIDE OF DOOR.
LOCATE PULL OPPOSITE HINGE.
18. IN EXISTING PARTITION WHERE METAL PLATE IS REQUIRED TO SUPPORT
CABINETS, REMOVE SECTION OF EXISTING GYPSUM WALL BOARD TO INSTALL
METAL PLATE,
19. PROVIDE A MINIMUM 1 -112" FILLER/ SCRIBE STRIPS @ JUNCTION BETWEEN ALL
BASE AND WALL CABINETS AND ADJACENT WALLS TO ALLOW DOORS TO SWING
OPEN AT LEAST 90 DEGREES.
20. 3MM EDGE BANDING ON ALL EXPOSED EDGES (DRAWERS AND DOORS).
21. ALL SOLID SURFACES SHALL HAVE A RADIUS EDGE.
22. ALL SOLID SURFACE TRIMS AND TRANSACTION TOP SHALL HAVE A SOFTENED
EDGE.
23. THE UNDERSIDE OF ALL WORK SURFACES SHALL BE SMOOTH AND EVEN IN
ORDER TO ALLOW BHSF TO MOUNT TRACKS FOR ADJUSTABLE KEYBOARD
TRAYS PROVIDED BY OWNER.
24. ALL CABINET BASES SHALL INCLUDE 4" HIGH WITH 2" RECESSED TOE KICK BASE.
25. SEAL UNDERNEATH COUNTER TOP. NO EXPOSED PLYWOOD.
26. COVER ALL EXPOSED SINK PIPES WITH PANEL DOOR.
27. ALL MILLWORK EXPOSED EDGES SHALL BE FINISHED.
TYPICAL BLOCKING /ANCHORING LOCATION
VERIFY ALL DIMENSIONS WTH CASEWORK CONTRACTOR.
BLOCKING HEIGHT MAY VARY DEPENDING ON CABINET HEIGHT,
COUNTER TOP HEIGHT & FIELD CONDITIONS
FASTENER
6" (18 GAUGE STEEL
STRAP REINFORCING
w IN WALL
CIL - -
FINISH FLOOR
BASE CABINET
FASTENER ..
(TOP OF CABINET) J
J-,
6" (18 GAUGE STEEL
STRAP REINFORCING IN
WALL (ALL REINFORCING
SHALL BE FASTENED TO
A MINIMUM OF 3 STUDS)
NOTES: FOR CABINETS
36 "WIDE ORWIDER,
PROVIDE 3 FASTENERS
PER PLATE PER CABINET.
FOR CABINETS LESS
THAN 36" VVIDE PROVIDE 2
FASTENERS PER PLATE
PERCABINET.
6" (18 GAUGE STEEL STRAP) % - 6" (18 GAUGE STEEL STRAP) 6" (18 GAUGE STEEL STRAP)
- - - - - -- -
4
C
0
C4 N N CV
- Q
[V CV cj (y
D q Cb
O O O
V r N N
N
-_F �-
TYPICAL BLOCKING LOCATION FOR 30" UPPER TYPICAL BLOCKING LOCATION FOR 24" UPPER TYPICAL BLOCKING LOCATION FOR 36" UPPER
CABINETS &34" BASE CABINETS CABINETS & 34" BASE CABINETS WITH SINK CABINETS & 34" BASE CABINETS
SS -3
SOLID SURFACE CAP
1/2" MDF PLYWOOD WITH
LAMINATE FINISH
HOMOSOTE PANEL WITH HOLES AND BAMBOO
REEDS INSERTED INTO HOLES EPDXY
COATED RIVER ROCK OVER PANELS
NOTE:
SIGNAGE BOX IS TO BE REMOVABLE.
- PLANTER SECTION
1/2" THICK TEMPERED GLASS
CONSTRUCT SLEEVE TO SLIDE
GLASS PANEL FOR SUPPORT
SOLID SURFACE (SOFTENED EDGE)
SS -2
21/2 "x2" F.R. WOOD FRAMING
R R A Y
healthcare facilities solutions
6800 Broken Sound Boulevard NW
Suite 125
Boca Raton, FL 33487
t: 561.995.1700
f: 561,995.1701 firm license number
www.arrayhfs.com AA26000880
SEAL:
q
,y wq
MARK D. TAUDIEN AR0011821
CONSULTANTS:
Smith Seckman Reid, Inc.
600 West Hillsboro Blvd., Suite 300
Deerfield Beach, FL 33441
OWNER:
BAPTIST HEALTH SOUTH
FLORIDA
HOSPITAL:
SOUTH MIAMI
HOSPITAL
PROJECT:
Info Desk Et Coffee Shop
ADDRESS:
6200 Southwest 73rd Street
South Miami, FL 33143
1 BID AND PERMIT SET 107-30-12
NO. DESCRIPTION DATE
REVISIONS /ISSUES
SHEET TITLE:
CASEWORK SECTIONS a
DETAILS
DRAWN: ES CHECKED: MDT
1/2" THICK LAMINATE CLAD
PLYWOOD PANEL CON /REF No. 00000
PL -1
PROJECT No. 3601
3/4"x4" FINISHED TO MATCH DATE: 07/30/2012 SCALE: As indicated
LAMINATE -
SHEET NO.
A632B
fhic dpr_urnenl ie a copyright prolerted irutrurnent of servico, properly of FlftRAY uud
licensed for us., in the titled pirojnrt only. P,eprodurfi[n or uae of thin doc�rnent
without wrlllen pennis'Sion of kRRA'' is ille4nl and will be prbs'eculed under Lhe law_
(CiCOPYRIGHT - 2012 ARRAY HFS