Loading...
12-939-0021 2 3 4 5 SOUTH MIAMI HOSPITAL E Info Desk Ei Coffee Shop 6200 Southwest 73rd Street South Miami, FL 33143 C I n VICINITY MAP OWNER BAPTIST HEALTH SOUTH FLORIDA 8900 Kendall Drive MIAMI, FL 33178 PHONE: 305.662.5150 Permit Set 7 -30 -12 ARCHITECT ARRAY Healthcare Facilities Solutions 6800 Broken Sound Parkway NW Boca Raton, FL 33487 PHONE: 561.995.1700 CODE REQUIREMENTS FOR RENOVATION PROJECT PROJECT LOCATION APPLICABLE NFPA CODES, STANDARDS, AND GUIDELINES: APPLICABLE CODES: NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2007, FLORIDA BUILDING CODE 2010 EDITION NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2007; FLORIDA EXISTING BUILDING CODE 2010 EDITION NFPA 14, STANDARD FOR THE INSTALLATION OF STANDPIPE & HOSE SYSTEMS, 2007; FLORIDA BUILDING CODE, MECHANICAL 2010 EDITION NFPA 70, NATIONAL ELECTRIC CODE, 2008 FLORIDA BUILDING CODE, FUEL GAS 2010 EDITION NFPA 72, NATIONAL FIRE ALARM CODE, 2007; FLORIDA FIRE PREVENTION CODE 2010 EDITION NFPA 75, STANDARD FOR THE PROTECTION OF INFORMATION TECHNOLOGY EQUIPMENT, 2009, q FLORIDA BUILDING CODE, CHAPTER 27 (ELECTRICAL) 2010 NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR CONDITIONING & VENTILATING SYSTEMS, 2009 „ E BARRIER FREE SUBCODE FLORIDA BUILDING CODE 2010 NFPA 101, LIFE SAFETY CODE, 2009 AIA GUIDELINES (FOR HOSPITALS & HEALTHCARE FACILITIES), 2010 NFPA 110, STANDARD FOR EMERGENCYAND STANDBY POWER SYSTEMS, 2005, NFPA 101, LIFE SAFETY CODE, 2009, CHAPTER 18 - NEW HEALTHCARE OCCUPANCY NFPA 220, STANDARD ON TYPES OF BLDG CONSTRUCTION, 2012 NFPA 241, STANDARDS FOR SAFEGUARDING CONST., ALTERATION AND DEMO OPERATIONS 2004 BUILDING CODE NFPA 101 BUILDING OCCUPANCY CLASSIFICATION PROJECT LOCATION; y INSTITUTIONAL (NO CHANGE) TYPE OF CONSTRUCTION: _. >� I� VICINITY MAP OWNER BAPTIST HEALTH SOUTH FLORIDA 8900 Kendall Drive MIAMI, FL 33178 PHONE: 305.662.5150 Permit Set 7 -30 -12 ARCHITECT ARRAY Healthcare Facilities Solutions 6800 Broken Sound Parkway NW Boca Raton, FL 33487 PHONE: 561.995.1700 CODE REQUIREMENTS FOR RENOVATION PROJECT APPLICABLE CODES: APPLICABLE NFPA CODES, STANDARDS, AND GUIDELINES: APPLICABLE CODES: NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2007, FLORIDA BUILDING CODE 2010 EDITION NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2007; FLORIDA EXISTING BUILDING CODE 2010 EDITION NFPA 14, STANDARD FOR THE INSTALLATION OF STANDPIPE & HOSE SYSTEMS, 2007; FLORIDA BUILDING CODE, MECHANICAL 2010 EDITION NFPA 70, NATIONAL ELECTRIC CODE, 2008 FLORIDA BUILDING CODE, FUEL GAS 2010 EDITION NFPA 72, NATIONAL FIRE ALARM CODE, 2007; FLORIDA FIRE PREVENTION CODE 2010 EDITION NFPA 75, STANDARD FOR THE PROTECTION OF INFORMATION TECHNOLOGY EQUIPMENT, 2009, FLORIDA BUILDING CODE, CHAPTER 13 (ENERGY) 2010 NFPA 80, STANDARD FOR FIRE DOORS AND FIRE WNDOWS, 2007; FLORIDA BUILDING CODE, CHAPTER 27 (ELECTRICAL) 2010 NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR CONDITIONING & VENTILATING SYSTEMS, 2009 FLORIDA BUILDING CODE, PLUMBING 2010 NFPA 99, STANDARD FOR HEALTHCARE FACILITIES, 2005; BARRIER FREE SUBCODE FLORIDA BUILDING CODE 2010 NFPA 101, LIFE SAFETY CODE, 2009 AIA GUIDELINES (FOR HOSPITALS & HEALTHCARE FACILITIES), 2010 NFPA 110, STANDARD FOR EMERGENCYAND STANDBY POWER SYSTEMS, 2005, NFPA 101, LIFE SAFETY CODE, 2009, CHAPTER 18 - NEW HEALTHCARE OCCUPANCY NFPA 220, STANDARD ON TYPES OF BLDG CONSTRUCTION, 2012 NFPA 241, STANDARDS FOR SAFEGUARDING CONST., ALTERATION AND DEMO OPERATIONS 2004 BUILDING CODE NFPA 101 BUILDING OCCUPANCY CLASSIFICATION INSTITUTIONAL GROUP 1(NO CHANGE) INSTITUTIONAL (NO CHANGE) TYPE OF CONSTRUCTION: IB (NO CHANGE) TYPE II (2 -2 -2) (NO CHANGE) EXISTING BUILDING HEIGHT/ AREA: NO CHANGE NO CHANGE PROJECT AREA: 398.4 SQ. FT. 398.4 SQ. FT. FIRE SUPPRESSION SYSTEM EXISTING NFPA 13 SPRINKLER SYSTEM EXISTING NFPA 13 SPRINKLER SYSTEM TABLE 503: ALLOWABLE HEIGHT/ AREA NOTAPPLICABLE NOTAPPLICABLE SEISMIC / W ND REQUIREMENTS OCCUPANCY CATEGORY NOT APPLICABLE NOT APPLICABLE SEISMIC DESIGN CATEGORY NOTAPPLICABLE NOTAPPLICABLE WIND ZONE NOT APPLICABLE NOTAPPLICABLE CORRIDOi CORRIDOR SERVING 50 PEOPLE OR LESS 36 INCHES CORRIDORS NON HOSPITAL 44 INCHES CORRIDOR ACCESS (MIN.) 60 INCHES CORRIDORS 1 -2 BED MOVEMENT 96 INCHES ALLOWABLE DEAD END CORRIDOR: 20 FEET TRAVEL DISTANCE: MAXIMUM ALLOWABLE TRAVEL DISTANCE 200 FEET 200 FEET SUITE TRAVEL DISTANCE 100 FEET 100 FEET COMMON PATH OF TRAVEL 75 FEET 75 FEET OCCUPANT: SEE LIFE SAFETY PLANS SEE LIFE SAFETY PLANS OCCUPANT LOAD BY TABLE ACTUAL OCCUPANT LOAD WITHIN WORK AREA 5 OCCUPANTS EXIT: (MINIMUM) NUMBER OF EXITS REQUIRED WITHIN WORK AREA 2 REQUIRED (< 500 OCCUPANTS TOTAL FLOOR) (MINIMUM) DOOR AND CORRIDOR WIDTH REQUIRED WITHIN WORK AREA MINIMUM DOOR VADTH 32" CORRIDOR FIRE - RESISTANT RATING W TH OCCUPANT LOAD GREATER THAN 30 0 0 INTERIOR FINISHES EXIT I CORRIDORS ROOMS _ CLASS A CLASS A CLASS B CLASS 1 CLASS A OR B N/A INTERIOR WALL AND CEILING FINISH REQUIREMENTS INTERIOR FLOOR FINISH REQUIREMENTS MEP ENGINEER Smith Seckman Reid, Inc. 600 West Hillsboro Blvd., Suite 300 Deerfield Beach, FL 33441 PHONE: 954.421.1260 Sheet List Sheet List 7 Sheet Sheet -- - Number Sheet Name Number Sheet Name ARCHITECTURAL CS -1 COVER SHEET G001 GENERAL INFORMATION ALS101 FIRST FLOOR - LIFE SAFETY PLAN AD111 FIRST FLOOR - DEMOLITION PLAN /ICRA A001 PHASING /ICRA PLAN �A111 FIRST FLOOR - ARCHITECTURAL PLAN FPO FLOOR—, DIMENSION PLAN A113_ FIRST FLOOR - EQUIPMENT PLAN A114 FIRST FLOOR — REFLECTED CEILING PLAN & DETAILS A115 FIRST FLOOR — FINISH PLAN A211 INTERIOR ELEVATIONS A212 INTERIOR ELEVATIONS - - - - -- - - - -- - - -- - - - - - - -- _ - A631 CASEWORK SECTIONS & DETAILS A632A CASEWORK SECTIONS & DETAILS A632B CASEWORK SECTIONS & DETAILS A801 SPECIFICATIONS A802 SPECIFICATIONS A803 SPECIFICATIONS MECHANICAL M0.1 MECHANICAL LEGENDS, SCHEDULES AND DRAWING INDEX MO.2 MECHANICAL SPECIFICATIONS M0.3 MECHANICAL CONSTRUCTION ZONE VENTILATION PLAN M0.4 MECHANICAL CONSTRUCTION ZO_ NE VENTILATION PLAN M1.1 FIRST FLOOR PLAN DEMOLITION MECHANICAL M2.1 FIRST FLOOR PLAN - NEW CONSTRUCTION MECHANICAL M3.1 MECHANICAL DETAILS M3.2 MECHANICAL DETAILS AND CONTROLS FIRE PROTECTION FP0.1 FIRE PRECTECTION LEGENDS, SCHEDULES AND DRAWING INDEX FPO.2 FIRE PRCTECTION SPECIFICATION FPO.3 FIRE PRCTECTION SPECIFICATION FP1.1 FIRST FLOOR PLAN - DEMOLITION FIRE PROTECTION FP2.1 FIRST FLOOR PLAN - NEW CONSTRUCTION FIRE PROTECTION FP5.1 FIRE PRCTECTION DETAILS PLUMBING PO.1 PLUMBING LEGENDS, SCHEDULES AND DRAWING INDEX PO.2 PLUMBING SCHEDULES PO.3 PLUMBING SPECIFICATIONS PO.4 PLUMBING SPECIFICATIONS PO.5 PLUMBING SPECIFICATIONS PO.6 PLUMBING SPECIFICATIONS P2.0 FIRST FLOOR PLAN - NEW CONSTRUCTION PLUMBING P2.1 FIRST FLOOR PLAN - NEW CONSTRUCTION PLUMBING P4.1 PLUMBING RISER DIAGRAMS P5.1 PLUMBING DETAILS ELECTRICAL EO.0 ELECTRICAL LEGEND, NOTES AND DRAWING INDEX EO.1 ELECTRICAL LOCATIONS REFERENCE PLAN E1.1 FIRST FLOOR PLAN - DEMOLITION ELECTRICAL E2.1 FIRST FLOOR PLAN - NEW CONSTRUCTION LIGHTING E2.2 FIRST FLOOR PLAN - NEW CONSTRUCTION POWER & SYSTEMS E3.1 ELECTRICAL ONE -LINE DIAGRAM E4.1 ELECTRICAL SCHEDULES E5.1 ELECTRICAL SPECIFICATIONS E5.2 ELECTRICAL SPECIFICATIONS rll °Y O 'SOt TLA MIAMlii UILJ)) fix � WEPT. } tJs: rL)RAL, S" (,TIQN I A R R A Y sr t d healthcare facilities solutions 6800 Broken Sound Boulevard NW Suite 125 Boca Raton, FL 33487 t: 561.995.1700 f: 561.995.1701 www.arrayhfs.com firm license number AA26000880 MARK D. TAUDIEN AR0011821 CONSULTANTS: Smith Seckman Reid, Inc. 600 West Hillsboro Blvd., Suite 200 Deerfield Beach, FL 3344'1 OWNER: BAPTIST HEALTH SOUTH FLORIDA HOSPITAL: SOUTH MIAMI HOSPITAL PROJECT: Info Desk Et Coffee Shop ADDRESS: 6200 Southwest 73rd Street South Miami, FL 33143 1 BID AND PERMIT SET 07 -30 -12 -. - - --- -- - - -_ - NO. DESCRIPTION DA- TE REVISIONSIISSUES SHEET TITLE: COVER SHEET DRAWN: FL CHECKED: MDT CON /REF No. 00000 PROJECT No. 3601 DATE: 07/30/2012 SCALE: 12" = 1' -0" SHEET NO. CS -1 Ihie dUCllfnf'11t is a copyright pro ter Lel ifi�trurnent ul' service, property of ARItAY rind l-ensed for uee in the titlod praject oily. Reproductbr or aee of this document ithnli written prrniie3iun u ARRAY is illegal (if id ;,ill be pioaecutod under the law. (C)COPYRIGHT - 2012 ARRAY HFS