12-938-005
TO TO TO ATS `E ATS -I NORTH TOWER (ATS -1) 800 KW 800 KW EMERGENCY EMERGENCY GENERATOR GENERATOR I� h 4 SETS OF 4 #500, _T 1#3 /OG IN 4'C. EACH 800 KW EMERGENCY GENERATOR 4 SETS OF 4 #500, 1 #3 /OG IN 4'C. EACH 800 KW EMERGENCY GENERATOR h r C 5000A FEEDER SYMBOL 5000A ( ( i200A ( 1200A \ 1200A SPACE C 1200AF SPACE 1200AT 1200AF 1200AT 600 TO TO NORTH ATS -4 TOWER FIRE 3p PUMP NMSBI 3000A 277/480V 3PH, 4W 225 1000 600 TO SPARE Ti! TO TO SPARE TO TO TO LS CR -i CR -2 EO TO ATS -11 CR -5NT -2 ATS -3 NORTH ATS NORTH ATS -5 ATS -10 EDP4 ATS -11 TOWER TOWER MAIN 30 to (ATS -3) (ATS -2) An BLDG. 3000A. BUS DUCT - TO FPL VAULT. 54,000A AVAILABLE FAULT CURRENT. 3000A NC M1 NO 3000A TI 3000A. BUS DUCT TO FPL VAULT. 54,000A AVAILABLE FAULT CURRENT. NC 3000A FP &L VAULT AVAILABLE FAULT CURRENT = 34,585A. - 5 SETS(4 #750MCM -4 "C.) NMSB2 FEEDER SYMBOL PAVILION 277/4 80V 277/4 ATS -9 SWITCHBOARD 3PH, 4W FEEDER SYMBOL MSN1 a 34 CRITICAL 2000A, 3PH 0 ATS -2 2 4W,277/480 00 • N 3 SETS OF 4 #500, 1 #4 /OG. IN 4' C. EACH. NSB2 ATS -6 1000A. 4P (EQUIP. SYS.) PRIORITY 3 ATS -8 FEEDER SYMBOL CONDUCTORS (3 PHASE, 3 WIRE) WITH GROUND RACEWAY SIZE CONDUIT ATS -9 CONDUCTORS (3 PHASE. 4 WIRE) WITH GROUND RACEWAY SIZE CONDUIT FEEDER SYMBOL ATS -12 34 CRITICAL 600A. 4P ATS -2 2 EQUIPMENT 600A.4P 3 *8 & 1 *IOG. 314 50 600A. 4P V 36 7 O (LIFE SAFETY) 3 *6 & 1 *IOG. 314 (EQUIP. SYS.) 4 *6 & 1 *10G. 1' (EQUIP. SYS.) 5 3 *4 & 1 *8G. 1' PRIORITY I 4 *4 & 1 *8G. 1 114 6 PRIORITY 2 3 *3 & 1 *8G. 1 114 100 PRIORITY 1 1 114 8 9 3 *1 & 1 *6G. 1 1/1 125 4 *1 & 1 *6G. 2' 0 11 lE0HD3 MCCQ 150 4 *1 /0 & 1 *6G. t O 30 3 *2/0 & 1 *6G. 2' 175 4 *2/0 & 1 *6G. 2' DEMAND LOAD SUMMARY 15 3 *3/0 & 1 *6G. 2' 200 4 *3/0 & 1 *6G. 2' 6 17 > 3 *4/0 & 1 *4G. 2' 225 EXISTING LOAD * 27 KVA 2 1/1 EODPA fi> 1EOHD2 2 1/1 250 EQUIP BRANCH 2 1/1 0 DEMAND LOAD ADDED: 1.1 KVA 3 *350 KCMIL & 1 *4G. 5 1 600 4 *350 KCMIL & 1 *4G. 3' I 600 3 3 *500 KCMIL & 1 *3G. 3 1/1 NEW TOTAL DEMAND LOAD: 28.1 KVA 4 *500 KCMIL & 1 *3G. 3 1/1 EQUIP. 5 3 *600 KCMIL & 1 *3G. EQUIP. 400 4 *600 KCMIL & 1 *3G. �n BRANCH 7 BRANCH 2-2 1/1 500 FEEDER SCHEDULE BASED ON N.E.C. TABLE 310 -16 FOR COPPER CONDUCTORS FEEDER SYMBOL CONDUCTORS (3 PHASE, 3 WIRE) WITH GROUND RACEWAY SIZE CONDUIT NOMINAL AMPERE RATING CONDUCTORS (3 PHASE. 4 WIRE) WITH GROUND RACEWAY SIZE CONDUIT FEEDER SYMBOL ATS -1 NEW CONSTRUCTION CRITICAL CONNECT TO EXIST. AT THIS POINT ATS -2 2 EQUIPMENT 1 3 *8 & 1 *IOG. 314 50 4 *8 & 1 *10G. V 2 3 3 *6 & 1 *IOG. 314 60 4 *6 & 1 *10G. 1' 4 5 3 *4 & 1 *8G. 1' 70 4 *4 & 1 *8G. 1 114 6 7 3 *3 & 1 *8G. 1 114 100 4 *3 & 1 *8G. 1 114 8 9 3 *1 & 1 *6G. 1 1/1 125 4 *1 & 1 *6G. 2' 0 11 3 *1/0 & 1 *6G. 1 1/1 150 4 *1 /0 & 1 *6G. 2' 12 0> 3 *2/0 & 1 *6G. 2' 175 4 *2/0 & 1 *6G. 2' 14 15 3 *3/0 & 1 *6G. 2' 200 4 *3/0 & 1 *6G. 2' 6 17 > 3 *4/0 & 1 *4G. 2' 225 4 *4/0 & 1 *4G. 2 1/1 18 fi> 3 *250 KCMIL & 1 *4G. 2 1/1 250 4 *250 KCMIL & 1 *4G. 2 1/1 0 21 3 *350 KCMIL & 1 *4G. 3' 300 4 *350 KCMIL & 1 *4G. 3' 2 3 3 *500 KCMIL & 1 *3G. 3 1/1 350 4 *500 KCMIL & 1 *3G. 3 1/1 4 5 3 *600 KCMIL & 1 *3G. 3 1/1 400 4 *600 KCMIL & 1 *3G. 4' PRIORITY 4 SUBTOTAL 7 6 *250 KCMIL & 2 *2G. 2-2 1/1 500 8 *250 KCMIL & 2 *2G. 2 -2 1/¢ t- 9 6 *350 KCMIL & 2 *1G. 2 -3' 600 8 *350 KCMIL & 2 *1G. 2 -3' 31 6 *500 KCMIL & 2 *1 /OG. 2-3' 700 8 *500 KCMIL & 2 *1 /OG. 2 -3 1/1 2 3 6 *600 KCMIL & 2 *1 /OG. 2-3 1/1 800 8 #600 KCMIL & 2 *1 /OG. 2 -4' 4 5 9 *400 KCMIL & 3 *2 /OG. 3 -3' 1000 12 *400 KCMIL & 3 *2 /OG. 3 -3' 6 7 9 *600 KCMIL & 3 *3 /OG. 3-3 1/1 1200 12 *600 KCMIL & 3 *3 /OG. 3 -4' 8 9 12 *600 KCMIL & 4 *4 /OG. 4-3 1/1 1600 16 *600 KCMIL & 4 *4 /OG. 4 -4' 40 41 15 *600 KCMIL & 5 *250G. 5-3 1/1 2000 20 *600 KCMIL & 5 *250G. 5 -4' 42 43 18 *600 KCMIL & 6 *350G. 6-3 2500 24 *600 KCMIL & 6 *350G. 6 -4' 44 45 21 *750 KCMIL & 7 *400G. 7-4' 3000 28 *750 KCMIL & 7 *400G. 7 -5' 46 47 27 *750 KCMIL & 9 *500G. 9-4' 4000 36 *750 KCMIL & 9 *500G. 9 -5' 48 NOTES: 1. 600 KCMIL AND 750 KCMIL FEEDERS SHALL BE COORDINATED WITH PROPER TERMINATION LUGS OR PROVIDED WITH MAC ADAPTERS AS REQUIRED TO COORDINATE WITH STANDARD BREAKER LUG SIZES. 2. SEE SPECIFICATIONS FOR ACCEPTABLE CONDUCTOR TYPES. � I I GEH I 1 175 EQUIP. I I BRANCH I 4 #6,1 #IOG. 30KVA 4 #2,1 #6G. GEL 1 100 EQUIP. BRANCH KEYED NOTES: OREMOVE EXISTING FEEDER AND PROVIDE NEW AS INDICATED. COORDINATE SHUTDOWN WITH HOSPITAL A MINIMUM OF 1 WEEK IN ADVANCE. OREMOVE EXISTING 3P,50A BREAKER FEEDING PANEL LSH1 AND REPLACE WITH 3P,70A SQUARE D TYPE FC BREAKER. COORDINATE WORK AND SHUTDOWN WITH REPLACEMENT OF FEEDER. O PROVIDE NEW 3P,175A CUTLER HAMMER FD TYPE BREAKER FOR NEW FEEDER OPROVIDE NEW LABELS TO INDICATE 'SPARE' FOR EXHAUST FANS EF -6A, EF -6B & EF -6C CUBICLES ONCE RE- CIRCUITED TO NEW PANEL. ODISCONNECT EXISTING FEEDER FOR GEH. TURN OFF BREAKER AND PROVIDE NEW LABEL TO INDICATE 'SPARE'. COORDINATE WORK WITH INSTALLATION OF NEW FEEDER TO MINIMIZE DOWNTIME. OUPON COMPLETION OF RE- FEEDING PANEL GEH TO NEW SOURCE - ATS SHALL BE RE- PROGRAMMED AS A PRIORITY 2 ATS. OUPON COMPLETION OF RE- FEEDING EXISTING GENERATOR ROOM EXHAUST FANS TO NEW SOURCE - ATS SHALL BE RE- PROGRAMMED AS A PRIORITY 3 ATS. CONSTRUCTION LEGEND SYMBOL DESCRIPTION PRIORITY EXISTING TO REMAIN DEMAND LOAD (KW)' -x- EXISTING TO BE REMOVED ATS -1 NEW CONSTRUCTION CRITICAL CONNECT TO EXIST. AT THIS POINT `0 o 0 CD UPDATED ATS PRIORITY SCHEDULE U) DESCRIPTION PRIORITY BRANCH DEMAND LOAD (KW)' CENTRAL ENERGY PLANT (PAVILION BLDG) ATS -1 1 CRITICAL 219 ATS -2 2 EQUIPMENT 109 ATS -3 2 EQUIPMENT 163 ATS -4 2 EQUIPMENT 4 ATS -E 1 LIFE SAFETY 23 ATS -6 3 EQUIPMENT 516 ATS -8 1 LIFE SAFETY 24 ATS -9 2 EQUIPMENT 66 ATS -10 i CRITICAL 91 ATS -11 3 EQUIPMENT 181 ATS -12 1 EQUIPMENT 220 ATS -CH5 4 EQUIPMENT 415 MAIN BLDG ATS -2 1 CRITICAL 11 ATS -3 2 EQUIPMENT 43 ATS -4 1 LIFE SAFETY 4 ATS -2LS 1 LIFE SAFETY 6 ATS -2C 1 CRITICAL 56 NORTH TOWER ATS -1 1 LIFE SAFETY 15 ATS -2 1 CRITICAL 73 ATS -3 2 EQUIPMENT 186 ATS -4 2 EQUIPMENT 36 ATS -5 1 CRITICAL 19 LOAD SUMMARY PRIORITY 1 SUBTOTAL 761 PRIORITY 2 SUBTOTAL 607 PRIORITY 3 SUBTOTAL 697 PRIORITY 4 SUBTOTAL 415 GRAND TOTAL 2480 le ffln an C. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- ine.com Firm Certification - EBMW857 John E. Moulder PE - 33200 NRchael A- Steward PE - 65701 SSR JOB # 1232030.0 ��lllilrrrr .�`0 E 7 STEW * : N 6570 cr W •• S TEOF __U �Z B��oP••'��: F i��rr11j11,��� DRAWN CHECKED DATE 08/15/12 REVISED SHEET N0. ELECTRICAL RISER DIAGRAM E3.1 U) W �a 0 Cn Cn CO O W Q cc o W _ COo 0 LL W u� Z J NH D 0 Oz Cl) c,r,l W W U W ��lllilrrrr .�`0 E 7 STEW * : N 6570 cr W •• S TEOF __U �Z B��oP••'��: F i��rr11j11,��� DRAWN CHECKED DATE 08/15/12 REVISED SHEET N0. ELECTRICAL RISER DIAGRAM E3.1