12-938-004f i iF \l l f Ty s ♦ \ � �- °''rJ /, Fes: �. 0 WIN MCCO ROOF PLAN - DEMOLITION - ELECTRICAL N 0' 2' 4' 8' 16' 24' 480 VOLT, 3 PHASE MOTOR BRANCH CIRCUITS HP FLA (1) NEMA (2) STARTER MCP (2) C.B. (3) FUSES (3) PHASE WIRE (4) GROUND WIRE (5) CONDUIT (6) NON TIME- I DELAY TIME- DELAY 1/2 i.t 1 3 20 3 3 12 12 314 3A 1.6 1 3 20 6 3 12 12 314 1 2.1 1 3 20 6 6 12 12 314 1 1/2 3.0 1 7 20 10 6 12 12 314 2 3.4 1 7 20 10 6 12 12 314 3 4.8 1 7 20 15 10 12 12 314 5 7.6 1 15 20 25 15 12 12 3/4 7 1/2 11 1 15 30 35 20 10 10 3/4 10 14 1 30 35 45 25 10 10 314 15 21 2 30 60 70 40 8 10 314 20 27 2 50 70 90 50 6 8 1' 25 34 2 50 90 110 60 6 8 1' 30 40 3 100 100 125 70 6 8 1' 40 52 3 100 150 175 100 4 6 11/4 50 65 3 100 175 200 125 3 6 11/4 60 77 4 150 200 250 150 2 6 11/4 75 96 4 150 250 300 175 1/0 4 2' 100 124 4 150 350 400 225 3/0 3 2' 125 156 5 250 400 500 300 410 3 2 1/1 150 180 5 250 450 600 350 250KCMIL 2 3' 200 240 5 400 600 800 450 400KCMIL 1 3' (1) PER NEC, TABLE 430 -150 (2)PER CUTLER HAMMER CATALOG (3) PER NEC, ARTICLE 430 -52 AND TABLE 430 -52 (4) PER NEC, ARTICLE 430 -22 (LENGTH OF FEEDER NOT TO EXCEED 400 FEET) (COPPER CONDUCTORS) (5) PER NEC, ARTICLE 250 -122 AND TABLE 250 -122 (GROUND SIZE BASED ON CIRCUIT BREAKER AMPERE RATING. WHERE NON TIME -DELAY FUSES ARE EMPLOYED, GROUND WIRE SIZE AND CONDUIT SHALL BE INCREASED ACCORDINGLY) (6) PER NEC, APPENDIX C, TABLES Cl THROUGH C12 GENERAL NOTE: OVERLOAD PROTECTION SHALL BE PROVIDED EITHER INTERNAL TO THE MOTOR OR BY MEANS OF AN EXTERNAL OVERLOAD DEVICE. GENERAL NOTES: A. CONTRACTOR SHALL COORDINATE EXACT LOCATION AND MOUNTING HE OF NEW LIGHTING ON ROOF IN THE FIELD WITH ENGINEER AND HOSPIT B. ALL CONDUIT ON ROOF LEVEL SHALL BE WEATHERTIGHT. PROVIDE INS GLAND COMRESSION FITTINGS AND IMC CONDUIT ALONG EXTERIOR ANE AREAS. KEYED NOTES: TO NEW O EXISTING ND CATEDGONENEW WORK PLAN. REMOVEAW WIRING B BACK TO RE-FED EXISTING EXISTING CONDUIT PENETRATION THROUGH ROOF MAY BE RE -USED. ONEW CIRCUIT FOR EXISTING EXHAUST FAN TO BE ROUTED VIA NEW STARTER ON FIRST FLOOR. REFER TO SHEET E2.1 FOR LOCATION OF STARTER. OPROVIDE NEW ENGRAVED LABEL FOR EXHAUST FAN INDICATING NEW AND CIRCUIT. OPROVIDE NEW PHOTOCELL TO CONTROL NEW ROOF LIGHTING FOR AL DUSK TO DAWN OPERATION. W NSTRUCTION LEGEND DESCRIPTION r EXISTING TO REMAIN EXISTING TO BE REMOVED NEW CONSTRUCTION e Smith al _S8 e1 Tnc 600 West Hillsboro, Suite 3C Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- ine.com Firm Certification - EB- 0000857 John E. Moulder PE - 33200 Michael A Steward PE - 65701 SSx JOB # 1232030.0 STE �\GENSE�� �O * : 65701 * D" W TE OF •.-' l?J �ONAL�� DRAWN CHECKED DATE 08/15/12 REVISED SHEET N0. CEP ROOF PLAN - DEMO & NEW WORK - ELECTRICAL E2.2 LU I C • O WQ � Q W _ I— `O Co LL CD j Q N� (D = D Iss— 0 0 U) w U U) W STE �\GENSE�� �O * : 65701 * D" W TE OF •.-' l?J �ONAL�� DRAWN CHECKED DATE 08/15/12 REVISED SHEET N0. CEP ROOF PLAN - DEMO & NEW WORK - ELECTRICAL E2.2