Loading...
12-637R-001SCOPE of WORK This is an existing 2 -Story Human Resources building located at South Miami Hospital, with an existing Faraday Firewatch XVI fire alarm control panel. The scope of this project shall be the remodeling & renovation of a portion of the 2nd floor. Under this scope, new Fire Alarm Notification devices shall be installed. There are existing initiating devices, and these devices (Smoke Detectors) shall remain in the same location, and not altered. Also, there are two (2) existing Pull Stations that shall be replaced with new devices. All new initiating devices will be connected to and supervised by the existing fire alarm panel, which will result in a fully functional single system for the existing facility. There shall be no other work preformed under this scope. The new Notification Appliances (Horn /Strobes & Strobe Lights) shall be connected to a new Remote Power Booster that shall be located on the 1st floor next to the existing Fire Alarm Control Panel. This new Power Booster shall be connected to, powered & supervised by the existing Fire Alarm Control Panel per the manufacturer's instructions & NFPA 72. NOTE: The existing Firewatch 16 Fire Alarm Control Panel is NOT capable of silencing the Horns, and leaving the Strobe Lights flashing. When the Silence switch is activated, the Horns will silence, and the Strobe Lights shall turn off as well. The devices being installed in this project are of the same manufacturer, and are UL /FM listed per NFPA 72 and are 100% compatible. THIS EXISTING FIRE ALARM SYSTEM IS CONVENTIONAL, HARDWIRED, NOT ADDRESSABLE THIS IS AN EXISTING 'REMOTE SUPERVISING STATION FIRE ALARM SYSTEM' REQUIRING 24 HOURS STANDBY BATTERY CALCULATION TIME. NOTE: ALL CIRCUITS ARE TO BE "CLASS B" THIS BUILDING IS FULLY SPRINKLED THE EXISTING FIRE ALARM ZONING OF INITIATING DEVICES SHALL NOT BE ALTERED UNDER THIS SCOPE, AND SHALL REMAIN AS IS. THE LISTED CABLES COMPLY WITH NEC 760- 30(a)(1); 760- 30(b)(4); 760- 31(e); AND 760- 71(f)(i). FIRE ALARM SYSTEM CONDUIT SHALL NOT BE FILLED TO GREATER THAN 40% OF ITS CAPACITY FIRE ALARM SYSTEM IS POWER- LIMITED. ALL EQUIPMENT IS OF THE SAME MANUFACTURER AND IS 100% COMPATIBLE AND IS UL /FM LISTED PER N.F.P.A. 72 THERE ARE NO NEW DEVICES BEING CONNECTED UNDER THIS SCOPE TO THE EXISTING FIRE ALARM CONTROL PANEL, THEREFORE NO STANDBY BATTERY CALCULATIONS FOR THE EXIST FIRE ALARM PANEL ARE REQUIRED. INSTALLING CONTRACTOR SHALL VERIFY THAT THE EXISTING SMOKE DETECTORS TO REMAIN ARE COVERED & PROTECTED DURING THE REMODELING FROM DEMOLITION /CONSTRUCTION DEBRIS AND DUST PARTICLES. FIREWATCH XVI IF TAPE (MASKING /DUCT, ETC.) IS USED TO COVER & PROTECT SMOKE DETECTORS, CONTRACTOR SHALL VERIFY THAT NO TAPE RESIDUE IS LEFT ON THE SMOKE DETECTORS AFTER REMOVAL OF TAPE. EXISTING SMOKE DETECTORS REPLACED WITH NEW ('ETRN') TYPICAL SCOPE OF WORK 2nd FLOOR FIRE ALARM SCALE: 1/8"- 1'0" THE INTENT IS TO SHOW THE AREA OF WORK UNDER THIS SCOPE. IT IS NOT THE INTENT TO SHOW THE ENTIRE FACILITY OR THE COMPLETE FIRE ALARM SYSTEM. NOTE: THE RELAY USED FOR THE MAG LOCK OVERRIDE SHALL RELEASE THE MAG LOCK UPON ACTIVATION OF THE FIRE ALARM, DEVICE LEGEND SYMBOL DESCRIPTION MODEL # SURFACE BACKBOX FLUSH BACKBOX EACP EX EXISTING FIRE ALARM CONTROL PANEL FIREWATCH XVI N/A EXISTING RPS NEW REMOTE POWER BOOSTER RSE -300 SUPPLIED w/ PRODUCT SUPPLIED w/ PRODUCT ® SMOKE DETECTOR 2W —B 1900 BOX w/ 1 GANG RING 1900 BOX w/ 1 GANG RING LEI PULL STATION 10561 1900 BOX w/ 1 GANG RING 1900 BOX w/ 1 GANG RING ® LOAD RELAY — SPST R712 -1 SUPPLIED w/ PRODUCT SUPPLIED w/ PRODUCT t) The 120VAC primary power shall conform to NFPA 72 HORN /STROBE 75CD WALL MNT ZH —MC —R 1900 DEEP BOX —NO RING 1900 DEEP BOX —NO RING O STROBE LIGHT 75CD WALL MNT ZR —MC —R 1900 DEEP BOX ---NO RING 1900 DEEP BOX —NO RING O C STROBE LIGHT 75CD CEILING MNT ZR —MC —CR 1900 DEEP BOX —NO RING 1900 DEEP BOX —NO RING "N" DENOTES NEW DEVICE. "EX" DENOTES EXISTING DEVICE. "ETRN" DENOTES EXISTING DEVICE REPLACED WITH NEW. 111AiA�! -DARE C0UNTY FIRE DEPARTF"EN EL 3, ; :t�l!'6 eta: A,.a"'Trrt pis E F" k sei l A tit�l."�"%::T. - ,:s:� r.r.� rM ALARM SYSTEM TO $T� MSTAI. LED IN ACCor�(OANCE WITH NFPA 72; 70;101 • � u r • •eWr`...,,.Rww.l Wal..,�,,.. Y� r� • W� -F-IRE N11TES WIRE LEGEND SYMBOL ,I) The,CICr,,,alarm d;%titem IsmLI.1,1_15ted as POWER LIMITED L DESCRIPTION U.L. Listed forW Its Intenaed use, CIRCUIT /FUNCTION A 1 PAIR #18 FPL, FPLP, FPLR, THHN INITIATING DEVICE CIRCUIT P 1 PAIR #14 FPL, FPLP, FPLR, THHN MAGNETIC DOOR LOCK RELAY CIRCUIT SX 1 PAIR #14 FPL, FPLP, FPLR, THHN NAC (NOTIFICATION APPLIANCE CIRCUIT ( "x" DENOTES CIRCUIT NUMBER) IT IS RECOMMENDED THAT YOU DO NOT SUBSITUTE FOR THE SPECIFIED CABLES ABOVE, AS THEY ARE FACTORY APPROVED TO INSURE PROPER OPERATION OF THE INSTALLED SYSTEM. NOTE: THE ABOVE LISTED CABLES COMPLY WITH NEC 760- 30(x)(1), 760- 30(b)(4), 760- 31(e), AND 760- 71(f)(i). NOTE, Do NOT disconnect the AC power feed from the terminal block to disconnect power, t) The 120VAC primary power shall conform to NFPA 72 2002 Edition Section 4.4141 111AiA�! -DARE C0UNTY FIRE DEPARTF"EN EL 3, ; :t�l!'6 eta: A,.a"'Trrt pis E F" k sei l A tit�l."�"%::T. - ,:s:� r.r.� rM ALARM SYSTEM TO $T� MSTAI. LED IN ACCor�(OANCE WITH NFPA 72; 70;101 • � u r • •eWr`...,,.Rww.l Wal..,�,,.. Y� r� • W� 1 ■ Engineer Engineering Corp. 0.506-" 7816 SW 195 TEAR CE " Miami, Florida 00. 1 Dll (305) 772 -50 S i f a n Z h a o � � '� � �'� � "•t ' �' 9 Y C.A.N. 9324 Fl. Re 0 5., These Fire Alarm drawings are approved and `comply with the Engineer of Record's design criteria. Project Name and Address BAPTIST HEALTH OF SOUTH FLORIDA SOUTH MIAMI HOSPITAL HR RELOCATION -2nd FL FIRE AIJARM 6200 SW 73rd ST. SUITE 200 SOUTH MIAMI, JFL. ;33143 �" •.' ill I Fire ,alarm System Distribllbtor DIVERSI &+E SYSTEMS I� INC. ' 13830 N.W. 19TH AVE. MIAMI, FLORID k 33054 (305) 681-1:3216 STATE EF # 0000220 Project Sheet Date FA — 3 9 0 2 01 -30 -202 Drawn .Y: SHEET i. G. 1 of 3 ■i I m -F-IRE N11TES ALL MAY NOT APPLY ,I) The,CICr,,,alarm d;%titem IsmLI.1,1_15ted as POWER LIMITED L • of the g „nera, alar,-9 type pe • NFPA 72. All equipment Is U.L. Listed forW Its Intenaed use, 2i Zhe �i�► alnrr-Y oanbl Ls Liroviwed with standby battery per I�FP ;�72 withV 24 hours standby and 5 minutes alarm. Should loss of normal 120VAC operating power occur, the fire alarm panel will autematically transfer to the standby battery, 3) A break In any field wiring or grounding of any conductor will result In the activation of the fire alarm panel trouble buzzer, which can I•e slenced by operating the 'Trouble Silence” button on the fire alarm panel, 4) Pull stations to be mounted at 43' AFF per the ADA code, 5) A/V devices to be mounted at 20' AFF per the NFPA code, G) Celing mounted smoke detectors shall not be located In a direct alrflow, nor closer than 3 feet from an air supply difuser per NFPA 72, 7) Power up and power down of the fire alarm panel must Ise .lone In the proper sequoncei Power Down, Disconnect battery and then turn off the AC power at the breaker, Power Up' Turn on the AC power at the breaker and then connect the battery, NOTE, Do NOT disconnect the AC power feed from the terminal block to disconnect power, t) The 120VAC primary power shall conform to NFPA 72 2002 Edition Section 4.4141 4,4,1,4,2 - Mechanical Protection 4,414,2A - The dedicated branch clrcult(s) and connectlo shall be mechanlcally protected, 4,4,1,4,2.2 - Clrcult disconnecting means shall have a red marking, shall be accessible only to authorized personnel and shall be Idenlfled as 'FIRE ALARM CIRCUIT" 4,4,1,4.2,3 - The location of the disconnecting means shall be permanetly Idendlfled at the fire alarm control unit, 9) The control (relay) module for AHU shutdown shall be located within three (3) feet of the device I•eing controlled, NFPA 101, The control module shall be located such that the front mounted LED Is vlslble upon entry Into mechanical room, Should the duct detectors be located above the telling, the control module shall be located In the telling dlrectly below the duct detector so the LED Is clearly vlSlble, The relay contacts have a MAXIMUM cababillty of 1.0 amps @ 24v and 0.3 amps E 120VAC, Contractor must verify that the shutdown circuit does NOT exceed these maximum current ratings, 10) The installing contractor shall set the device address as Identified on the Installation wiring dls•9rams, and there shall be no changes from the addresses shown, as this drawing will serve as the as -bunt drawing, and the software program Is being written based on the addresses shown, 11) The specified 'SLC /Data" loop cable Is extremely Important, and It Is recommended that It NOT be substituted by the Installer, The specified cable has been selected because It Meets all of the techlnal requirements of the system being Installed and Is on the approved factory list of cables, NOTICE. This drawing and all data Contained herein is the intellectual property of Diversifire Systems, Inc. and shall not be duplicated electronically or mechanically, modified or altered, used or disclosed in part or in whole for any reason or pupose without the express written consent of a principal of the firm, or be liable for the fullest legal recourse. FIRE INSPECTOR CHANGES 8/2/2012 No. Revision /Issue Date 1 ■ Engineer Engineering Corp. 0.506-" 7816 SW 195 TEAR CE " Miami, Florida 00. 1 Dll (305) 772 -50 S i f a n Z h a o � � '� � �'� � "•t ' �' 9 Y C.A.N. 9324 Fl. Re 0 5., These Fire Alarm drawings are approved and `comply with the Engineer of Record's design criteria. Project Name and Address BAPTIST HEALTH OF SOUTH FLORIDA SOUTH MIAMI HOSPITAL HR RELOCATION -2nd FL FIRE AIJARM 6200 SW 73rd ST. SUITE 200 SOUTH MIAMI, JFL. ;33143 �" •.' ill I Fire ,alarm System Distribllbtor DIVERSI &+E SYSTEMS I� INC. ' 13830 N.W. 19TH AVE. MIAMI, FLORID k 33054 (305) 681-1:3216 STATE EF # 0000220 Project Sheet Date FA — 3 9 0 2 01 -30 -202 Drawn .Y: SHEET i. G. 1 of 3 ■i I m