12-637-001SCOPE of WORK This is an existing 2 -Story Human Resources building located at South Miami Hospital, with an existing Faraday Firewatch XVI fire alarm control panel. The scope of this project shall be the remodeling & renovation .of a portion, of the 2nd floor. Under this scope, new Fire Alarm Notification devices shall be installed. There are existing initiating devices, and these devices (Smoke Detectors) shall remain in the same location, and not altered. Also, there are two (2) existing Pull Stations that shall be replaced with new devices. All new initiating devices will be connected to and supervised by the existing fire alarm panel, which will result in a fully functional single system for the existing facility. There shall be no other work preformed under this scope. The new Notification Appliances (Horn /Strobes & Strobe Lights) shall be connected to a new Remote Power Booster that shall be located on the 1St floor next to the existing Fire Alarm Control Panel. This new Power Booster shall be connected to, powered & supervised by the existing Fire Alarm Control Panel per the manufacturer's instructions & NFPA 72. NOTE: The existing Firewatch 16 Fire Alarm Control Panel is NOT capable, of silencing the Horns, and leaving the Strobe Lights flashing. When the Silence switch is activated, the Horns will silence, and the Strobe Lights shall turn off as well. The devices being installed in this project are of the same manufacturer, and are UL /FM listed per NFPA 72 and are 100% compatible. THIS EXISTING FIRE ALARM SYSTEM IS CONVENTIONAL, HARDWIRED, NOT ADDRESSABLE THIS IS AN EXISTING 'REMOTE SUPERVISING STATION FIRE ALARM SYSTEM' REQUIRING 24 HOURS STANDBY BATTERY CALCULATION TIME. AI nTE'. ALL CIRCUITS ARE TO BE "CLASS B" THIS BUILDING IS FULLY SPRINKLED THE EXISTING FIRE ALARM ZONING OF INITIATING DEVICES SHALL NOT BE ALTERED UNDER THIS SCOPE, AND SHALL REMAIN AS IS. THE LISTED CABLES COMPLY WITH NEC 760 - 30(x)(1); 760- 30(b)(4); 760- 31(e); AND 760- 71(f)(i). FIRE ALARM SYSTEM CONDUIT SHALL NOT BE FILLED TO GREATER THAN 40% OF ITS CAPACITY FIRE ALARM SYSTEM IS. POWER— LIMITED. ALL EQUIPMENT IS OF THE SAME MANUFACTURER AND IS 100%, COMPATIBLE AND IS UL /FM LISTED PER N.F.P.A. 72 THERE ARE NO NEW DEVICES BEING CONNECTED UNDER THIS SCOPE TO THE EXISTING FIRE ALARM CONTROL PANEL, THEREFORE NO STANDBY BATTERY CALCULATIONS FOR THE EXIST FIRE ALARM PANEL ARE REQUIRED. INSTALLING CONTRACTOR SHALL VERIFY' THAT THE EXISTING SMOKE DETECTORS TO REMAIN ARE COVERED & PROTECTED DURING THE REMODELING FROM DEMOLITION /CONSTRUCTION DEBRIS AND DUST PARTICLES. IF TAPE (MASKING /DUCT, ETC.) IS USED TO COVER & PROTECT SMOKE DETECTORS, CONTRACTOR SHALL VERIFY THAT NO TAPE RESIDUE IS LEFT ON TH,E SMOKE DETECTORS AFTER REMOVAL OF TAPE. EXISTING SMOKE DETECTORS TO REMAIN ('ETR') TYPICAL ! 9 WATAIFI SCOPE OF WORK Al APKA THE INTENT IS TO SHOW � THE AREA OF WORK UNDER THIS SCOPE. IT IS NOT THE INTENT TO SHOW THE ENTIRE FACILITY OR THE COMPLETE FIRE ALARM SYSTEM. DEVICE LEGEND FIRS, AI- - -ARr4 NEI ES ^^ SYMBOL DESCRIPTION MODEL # SURFACE BACKBOX FLUSH BACKBOX FACP EX' EXISTING FIRE ALARM CONTROL PANEL FIREWATCH XVI N/A EXISTING RPS NEW REMOTE POWER BOOSTER RSE -300 SUPPLIED w/ PRODUCT SUPPLIED w/ PRODUCT ® ETR SMOKE DETECTOR EXISTING EXISTING EXISTING EXISTING 0 PULL STATION 10561 1900 BOX w/ 1 GANG RING 1900 BOX w/ 1 GANG RING ® LOAD RELAY — SPST R712 -1 SUPPLIED w/ PRODUCT SUPPLIED w/ PRODUCT SYSTEM. HORN /STROBE 75CD WALL MNT ZH —MC —R 1900 DEEP BOX —NO RING 1900 DEEP BOX —NO RING O STROBE LIGHT 75CD WALL_ MNT ZR —MC —R 1900 DEEP BOX —NO RING 1900 DEEP BOX —NO RING O C STROBE LIGHT 75CD CEILING MNT ZR —MC —CR 1900 DEEP BOX —NO RING 1900 DEEP BOX —NO RING "ETR" DENOTES EXISTING DEVICE TO REMAIN. contacts have a MAXIMUM cabablLlty of 1.0 amps @ 24v and 0.3 amps @ 120VAC. Contractor must verify that the shutdown circuit does NOT exceed these maximum current NOTE: THE RELAY USED FOR THE MAG LOCK OVERRIDE MUST HAVE A SEPARATE, 1 PAIR, 2 CONDUCTOR WIRE ('P') HOMERUN TO THE EXISTING FACP. DO NOT CONNECT THIS RELAY TO ANY OTHER CIRCUIT (INITIATING, NAC, ETC.) Do 1Y RT MIAIVN- DAd�COUiWYYIrIF� ��p,�.'tM,__. BLDG. PMMIT W1AMR t+tAilI EXT.,•,_ --- FIRESUPP ESSI R- ----'- Ul p.ccolD �STA►� -� A72, 7% 101 - General Notes FIRS, AI- - -ARr4 NEI ES ^^ WIRE LEGEND of the genera: a'.arm t; pe- -)-r NFPA _72. All equipment Is SYMBOL 2) The fire alarm panel Is pi ovided clth standhy ba =tery DESCRIPTION Should loss of normal 120VAC operating power incur, the CIRCUIT/FUNCTION A 1 PAIR #18 FPL, FPLP, FPLR, THHN INITIATING DEVICE CIRCUIT 4) Pull stations to be mounted at 48' AFF per the ADA P 1 PAIR #14 FPL, FPLP, FPLR, THHN MAGNETIC DOOR LOCK RELAY CIRCUIT SX 1 PAIR #14 FPL, FPLP, FPLR, THHN NAC (NOTIFICATION APPLIANCE CIRCUIT ( "x" DENOTES CIRCUIT NUMBER) IT IS RECOMMENDED THAT YOU DO NOT SUBSITUTE FOR THE SPECIFIED CABLES ABOVE, AS THEY ARE FACTORY APPROVED TO INSURE PROPER OPERATION OF THE INSTALLED SYSTEM. 4.4.1.4.2.1 - The dedicated branch clrcuit(s) and connectio shall be mechanically protected. NOTE: THE ABOVE LISTED CABLES COMPLY WITH NEC 760- 30(a)(1), 760- 30(b)(4), 760- 31(e), AND 760- 71(f)(i). 4.4.1.4.2.3 - The location of the disconnecting means shall be permanetly Idendlfled at the fire alarm control unit. 9) The control (relay) module for AHU shutdown shall be Located within three (3) feet of the device being NOTE: THE RELAY USED FOR THE MAG LOCK OVERRIDE MUST HAVE A SEPARATE, 1 PAIR, 2 CONDUCTOR WIRE ('P') HOMERUN TO THE EXISTING FACP. DO NOT CONNECT THIS RELAY TO ANY OTHER CIRCUIT (INITIATING, NAC, ETC.) Do 1Y RT MIAIVN- DAd�COUiWYYIrIF� ��p,�.'tM,__. BLDG. PMMIT W1AMR t+tAilI EXT.,•,_ --- FIRESUPP ESSI R- ----'- Ul p.ccolD �STA►� -� A72, 7% 101 - General Notes FIRS, AI- - -ARr4 NEI ES ^^ ALL MAY NOV APPLY --^ ^ ^^ 1) The fire alarm system Is U.L. Listed as POWER LIMITED is of the genera: a'.arm t; pe- -)-r NFPA _72. All equipment Is U.L. Listed for_ Its-Intended use. ^ 2) The fire alarm panel Is pi ovided clth standhy ba =tery per NFPA 72 -H'th- 24 -ho4rc - standby, an6 5 m?wteE, alarm. Should loss of normal 120VAC operating power incur, the fire alarm panel will automatically transfer to the standby battery. 3) A break In any field wiring or grounding of any conductor will result In the activation of the fire alarm panel trouble buzzer, which can be sienced by operating the 'Trouble Silence' button an the fire alarm panel. 4) Pull stations to be mounted at 48' AFF per the ADA code. 5) A/V dgvlces to be mounted at 80' AFF per the NFPA code. 6) Celing mounted smoke detectors shall not be located In a direct alrflow, nor closer than 3 feet from an air supply difuser per NFPA 72. 7) Power up and power down of the fire alarm panel must be done In the proper sequences Power Downs Disconnect battery and then turn off the AC power at the breaker. Power Ups Turn on the AC power at the breaker and then connect the battery. NOTEi Do NOT disconnect the AC power feed from the terminal block to disconnect power. 8) The 120VAC primary power shall conform to NFPA 72 2002 Edition Section 4.4.1.41 4.4.1.4.2 - Mechanical Protection 4.4.1.4.2.1 - The dedicated branch clrcuit(s) and connectio shall be mechanically protected. 4.4.1.4.2.2 - Circuit disconnecting means shall have a red marking, shall be accessible only to authorized personnel and shall be idenifled as 'FIRE ALARM CIRCUIT.' 4.4.1.4.2.3 - The location of the disconnecting means shall be permanetly Idendlfled at the fire alarm control unit. 9) The control (relay) module for AHU shutdown shall be Located within three (3) feet of the device being controlled. NFPA 101. The control module shall be located such that the front mounted LED Is visible upon entry Into mechanical room. Should the duct detectors be located above the ceiling, the control module shall be located In the ceiling directly below the duct detector so the LED Is clearly visible. The relay contacts have a MAXIMUM cabablLlty of 1.0 amps @ 24v and 0.3 amps @ 120VAC. Contractor must verify that the shutdown circuit does NOT exceed these maximum current ratings. 10) The Installing contractor shall set the device address as Identified on the Installation wiring disgrams, and there shall be no changes from the addresses shown, as this drawing will serve as the as -built drawing, and the software program Is being written based on the addresses shown. 11) The specified 'SLC /Data' loop cable Is extremely Important, and It Is recommended that It NOT be substituted by the Installer. The specified cable has been selected because It meets all of the techlnal requirements of the, system beingllnstalled and Is on the approved factory list of cables. NOTICE.- This drawing and all data Contained herein is the intellectual property of Diversifire Systems, Inc., and shall not be duplicated electronically or mechanically, modified or altered, used or disclosed in part or in whole for any reason or pupose without the express written consent of a principal of the firm, or be liable for. the fullest legal recourse. No. Revision /Issue Date ' Drawing Reference Contract Set Sheet #: N/A Contract Set Date: N/A ,,Revision # /Date: N/A Engineer G . �y Erngide r4ng tCmrp0 85 ' 7816 SW 1:95; TERR E Mipmi, Floti7a '3t� 7 >_ ' � (305) 772 ='5 ®� o;: Sifang Zhao, P:, . •`V ,�`;. C.A.N. 9324 FI. Reg I N566'8.5 These Fire Alarm drawings are approved and comply, with the Engineer of Record's design criteria. Installing Contractor TRICITY ELECTRIC CO. 625 NW 16 AVENUE MIAMI, FL. 33125 (305) 642 4011 EC 0000136 J Project Name and Address BAPTIST HEALTH OF SOUTH FLORIDA SOUTH MIAMI HOSPITAL HR RELOCATION -2nd FL FIRE ALARM 6200 SW 73rd ST. SUITE 200 SOUTH MIAMI, FL. 33143 Fire Alarm System Distributor DIVERSIFIRE SYSTEMS INC. 13830 N.W. 19TH AVE. MIAMI, FLORIDA 33054 (305) 681 -3216 i\ STATE EF # 0000220 J Project Sheet I I Date FA -39 02 .01 -30 -2012 Drawn By: SHEET J.G. 1 of 3