12-565-007
FIRE BARRIER PARTITION OR CHASE TYPICAL DUCT INSULATION - ACCESS PANEL, NOTE 5 NOTES: 1" MIN. a NOTE 6 SLEEVE, NOTE 2 DAMPER COLLAR EXTENSION INTEGRAL PART OF SLEEVE DAMPER, NOTE 1 DUCT CONNECTION, NOTE 4 SLEEVE, NOTE 2 PERIMETER ANGLE, NOTE 3 (NOT FASTENED TO PARTITION) FIRE DAMPER DETAIL NOT TO SCALE O1 A VERTICAL DAMPER IS SHOWN. HORIZONTAL DAMPER INSTALLATION IS SIMILAR. FOLLOW DAMPER MANUFACTURER'S INSTRUCTIONS, INCLUDING FASTENER OPTIONS AND GAUGES FOR SLEEVE AND PERIMETER ANGLES. FIRE DAMPERS MUST BE INSTALLED IN THE PARTITION OR FLOOR, NOT OUTSIDE THE PARTITION. O2 GALVANIZED SLEEVE: GAUGE NOT LESS THAN CONNECTING DUCT. FASTEN SLEEVE TO DAMPER FRAME AND TO PERIMETER ANGLES. O3 PERIMETER ANGLES: GALVANIZED STEEL, NOT LESS THAN 1-1/2" x 1-1/2" 14 GAUGE, TO PROVIDE 1 INCH MINIMUM OVERLAP OF OPENING ON ALL 4 SIDES. ® BREAKAWAY DUCT CONNECTION: CONTRACTOR'S OPTION OF TYPES SHOWN IN SMACNA LPDS, FIG. 2 -13. SEAL JOINTS. O5 ACCESS PANELS: SIZE AND LOCATION TO PERMIT SERVICING THE FUSIBLE LINK OR LINKS. © PROVIDE 1/4 TO 1/2 INCH CLEARANCE ON HEIGHT AND WIDTH. FILL OPEN SPACE WITH ROCK WOOL FIRESTOP FIBER. 2 4 r�:Lw 1 A 1O PRE -RATED CONCRETE FLOORS OR BLOCK WALLS= MIN 3" THICK CONCRETE FLOOR ASSEMBLY MIN 3 -1/2" THICK CONCRETE WALL ASSEMBLIES. 2O METALLIC PIPE. A) STEEL PIPE- 8 "DIAM (OR SMALLER) SCH. 40(OR HEAVIER) STEEL PIPE B) IRON PIPE - 8 "DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. C) CONDUIT- 4 "DIAM ( OR SMALLER) STEEL EMT OR CONDUIT D) COPPER TUBING - 4 "DIAM ( OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING E) COPPER PIPE- DIAM (OR SMALLER) REGULAR ( OR HEAVIER) COPPER PIPE THE ANNULAR SPACE SHALL BE MIN 1/2" TO MAX 7/8" O PACKING MATERIAL- MIN 2 -1/2" THICKNESS OF MINERAL WOOL (MIN. 4.0 PCF) INSULATION, FIRMLY PACKED INTO THE OPENING AS PERMANENT FORM. 4O FYRE- SHIELD - MIN 1/2" THICKNESS OF SEALANT APPLIED WITHIN ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL ASSEMBLY. THROUGH PENETRATION FIRESTOPPING UL -1479 2 HOUR FIRE RATED PENETRATION FIRESTOP FOR SINGLE METAL PIPE DETAIL !!1 NOT TO SCALE �I{ V II II Y Z I i • - i) J a W 0 a U z 0 1911:9 JOB NO.: 212 -1009 DATE : 04 -25 -12 PLOT SIZE: AS NOTED DESIGNED /DRAWN BY. A.V. CHECKED BY: F.A. SHEET No.: E -5 W W a a OC) M =z� o Q QOz - LL_ m z C) N 0 = N WQ N U i) J a W 0 a U z 0 1911:9 JOB NO.: 212 -1009 DATE : 04 -25 -12 PLOT SIZE: AS NOTED DESIGNED /DRAWN BY. A.V. CHECKED BY: F.A. SHEET No.: E -5