Loading...
12-559R-001F1 RST--- a =Abbreviations Symbol Legend General Notes and Specifications List of Drawings Information AL. ALUMINUM HORZ. HORIZONTAL NORTH ARROW 1. ALL WORK IS TO CONFORM TO THE FLORIDA BUILDING CODE, THE AMERICANS WITH Mechanical „ ^ DISABILITY ACT AND ALL OTHER APPLICABLE CODES AND REGULATIONS I General Notes, Location Map, Key Plan - p APPROX. APPROXIMATE HP HIGH POINT p y ` " -° " " "" ARCH. ARCHITECTURAL, ARCHITECT INSUL. INSULATE, INSULATION DIRECTION Abbreviations, Typical Mounting Heights MP -100 HVAC and Plumbing General Notes and Details 2• ALL CONTRACTORS ARE TO FAMILIARIZE THEMSELVES WITH, AND CONFIRM ALL EXISTING MATERIALS, AVG. AVERAGE INT. INTERIOR QUANTITIES, DIMENSIONS AND CONDITIONS PRIOR TO SUBMITTING THEIR BID. NOTIFY THE MP -11O HVAC and Notes and Details SECTION NUMBER ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. . Architectural BD BOARD JT. JOINT SHEET NUMBER BD. BOTTOM OF LB. POUND 3. NO SUBSTITUTIONS UNLESS AUTHORIZED BY THE ARCHITECT, IN WRITING, PRIOR TO THE BID OPENING. ArCh MP -200 Ground Floor Mechanical Plan B.O.B. BOTTOM OF BEAM LP LOW POINT DETAIL NUMBER 4. ALL MATERIALS FURNISHED ON THE JOB SITE SHALL BE NEW AND STORED IN SUCH A MANNER AS TO A -1 Level 1 Floor Plan and Details B.O.G. BOTTOM OF CEILING MAX. MAXIMUM SHEET NUMBER PROTECT THEM FROM THE ELEMENTS. MP -210 Second Floor Mechanical Plan A -2 Level 2 Floor Plan and Partition Type BCTT. BOTTOM MECH. MECHANICAL 5. ALL CONTRACTORS ARE TO KEEP THE JOB SITE CLEAN AND FREE OF ALL DEBRIS AT ALL TIMES. MP -220 Third Floor Mechanical Plan CEM. PLS. CEMENT PLASTER MEMB. MEMBRANE SHEET NUMBER A -3 Level 3 Floor Plan 0--- ELEVATION NUMBER 6. DO NOT SCALE DRAWINGS. DIMENSION AND /OR EXISTING CONDITIONS GOVERN. NOTIFY THE MP -230 Fourth Floor Mechanical Plan C11TV CLOSED CIRCUIT TELEVISION MET. METAL ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. A -4 Level 4 Floor Plan (LG. CEILING MANF. MANUFACTURER DIRECTION CMU CONCRETE MASONRY UNIT MIN. MINIMUM 7. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH THE BEST PRACTICES OF THE CONSTRUCTION TRADE. A -5 Level 5 Floor Plan MP -240 Fifth Floor Mechanical Plan FLOOR NUMBER COL. COLUMN MISC. MISCELLANEOUS 00 (WHEN NECESSARY) 8. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. A -6 Level 6 Floor Plan and Existing Conditions MP -250 Sixth Floor Mechanical Plan CONC. CONCRETE MAT. MATERIAL DOOR NUMBER A -7 Door Schedule and Details CONT. CONTINUOUS NIC NOT IN CONTRACT g• DURING CONSTRUCTION THE CONTRACTOR SHALL COORDINATE ALL ACTIVITIES WITH THE OWNER'S PROJECT MANAGER. )IA. DIAMETER NO. NUMBER (HEN NECESS RY} 10. ALL TRADE CONTRACTORS SHALL VERIFY ALL UTILITIES, AND PLACEMENT LOCATIONS OF PIPE A -$ Elevator Enclosure Plans and Elevations 3 DIM. DIMENSION N.T.S. NOT TO SCALE 000 CONDUIT, EQUIPMENT, DUCTWORK, ETC., PRIOR TO SUBMITTING THEIR BID. DN, DOWN PLS. LAM. PLASTIC LAMINATE A -9 Exterior Elevations and Details Fire Alarm WINDOW NUMBER 11. ALL GYPSUM BOARD CORNERS SHALL RECEIVE METAL CORNER BEADS. ALL EXPOSED GYPSUM BOARD DBL. DOUBLE PL. PLATE EDGES SHALL HAVE METAL CASING BEADS. A -1O Partition Type, Interior Elevations and Details FA -100 Ground Floor Fire Alarm Plan FLOOR NUMBER DWG. DRAWING PLYWD. PLYWOOD (WHEN NECESSARY) A -11 Elevator Enclosure Wall Sections and Details 000 12• WHERE CONFLICTS EXIST AND / OR VARIANCES EXIST IN THE DRAWINGS, THE ARRANGEMENT OF BETTER FA -200 Second Floor Fire Alarm Plan EA. EACH PREFAB. PREFABRICATED QUALITY, GREATER QUANTITY, AND HIGHER COST SHALL BE INCLUDED IN THE BID PRICE. THE ARCHITECT ELEV. ELEVATON PVC POLYVINYL CHLORIDE PIPE ROOM NUMBER WILL HAVE FINAL DECISION REGARDING ITEM AND MANNER IN WHICH WORK SHALL BE INSTALLED. A -12 Incinerator ROOM Roof Plan, Section, and Details . FA -300 Third Floor Fire Alarm Plan ELEC. ELECTRICAL R. RADIUS O PARTITION TYPE 13. SUBMIT FOUR SETS MINIMUM OF DETAILED SHOP DRAWINGS, CUT SHEETS AND /OR SAMPLES FOR ALL Structural I EMERG. EMERGENCY REQ. REQUIRED PROCURED, MANUFACTURED OR SHOP CREATED ITEMS FOR REVIEW AND APPROVAL BY THE ARCHITECT. FA -400 Fourth Floor Fire Alarm Plan EQPT. EQUIPMENT REINF. REINFORCEMENT S -1 Level 1 Structural Repair Floor Plan SC SOLID CORE �0 REVISION MARK 14. ALL DETAILS, SECTIONS, DIAGRAMS, ETC. ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO FA -500 Fifth Floor Fire Alarm Plan . EQ. EQUAL APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE PROJECT. S -2 Level 2 Structural Repair Floor Plan EXH. EXHAUST SAM. SIMILAR SHT. SHEET 15. THE CONTRACTOR SHALL ARRANGE FOR ALL INSPECTIONS BY THE BUILDING AUTHORITIES. COST OF SPECIAL S -3 Level 3 Structural Repair Floor Plan FA -600 Sixth Floor Fire Alarm Plan EXIST. EXISTING O SPEC. SPECIFICATION TOILET ROOM ACCESSORY INSPECTORS SHALL BE INCLUDED IN THE PROJECT COST IF NECESSARY. E.J. EXPANSION JOINT S.S. STAINLESS STEEL S -4 Level 4 Structural Repair Floor Plan FA -700 Fire Alarm Riser E.W. EACH WAY SUSP SUSPEND, SUSPENDED S 5 L I 5 S{ t 1 R *. FI Dl ~% Product Approval Schedule COMPONENT APPROVAL NUMBER 000 FURNITURE/EQUIPMENT INDICATOR EWC ELECTRIC WATER COOLER SYS. SYSTEM STOREFRONT WINDOW WALL SYSTEM - IMPACT RESISTANT FD. FLOOR DRAIN TEMP. TEMPERED 09- 1110.04 ARCH ALUMINUM & GLASS CO., INC. 03 -17 -15 FIXED METAL LOUVRE DOOR 10- 0727.02 LINE OF OBJECT ABOVE FIN FINISH T &G TONGUE AND GROOVE 04 -22 -15 FL FLOOR T.O.B. TOP OF BEAM . • • • • • • • • ° • ° ° . ° • • • • ° ° ° EQUIPMENT/FURNITURE N.I.C. FT. FOOT T.O.S. TOP OF SLAB XXX SPACES LEVEL 1 41,192 SF /500 = 83 PEOPLE HIDDEN LINE FTG. FOOTING T.O.P. TOP OF PARAPET ONCOLOGY SURFACE GA. GAUGE T.O.W. TOP OF WALL BOUNDARY LINE GALV. GALVANIZED TYP. TYPICAL 86 PEOPLE EMPLOYEE PARKING GARAGE: LEVEL 5 42,813 SF /500 = DEMOLITION LINE G.C. GENERAL CONTRACTOR U.Q.N. UNLESS OTHERWISE NOTED LEVEL 6 33,184 SF /500 = GL. GLASS VERT. VERTICAL - - CENTER LINE GYPSUM W/ WITH 88 40 Product Approval Schedule COMPONENT APPROVAL NUMBER COMPANY NAME EXPIRATION DATE METAL DOOR SINGLE OR DOUBLE 09- 0112.03 NEXT DOOR COMPANY 05 -13 -14 STOREFRONT WINDOW WALL SYSTEM - IMPACT RESISTANT 09- 1022.01 ARCH ALUMINUM & GLASS CO., INC. 03 -31 -15 STOREFRONT DOOR - IMPACT RESISTANT 09- 1110.04 ARCH ALUMINUM & GLASS CO., INC. 03 -17 -15 FIXED METAL LOUVRE DOOR 10- 0727.02 NEXT DOOR COMPANY 01 -13 -15 2'X2' FIXED METAL LOUVRE DOOR 10- 0217.04 DAYBAR INDUSTRIES LIMITED 04 -22 -15 ROOF EDGE TERMINATION SYSTEM(COPING CAP) 10- 0603.02 WP HICKMAN COMPANY 10 -18 -12 eve ruc ura epar aor an FA -710 Fire Alarm Riser Continued S -6 Level 6 Structural Repair Floor Plan FA -720 Fire Alarm Riser Continued S -7 Structural Repair Sections S -8 Structural Repair Details FA -730 Fire Alarm, Schedules, Notes, and Details S -9 Elevator Enclosure Structural Plan and Details Electrical E -100 Electrical Symbols and Notes E -200 Ground Floor Electrical Power Plan Gam'' - - PROPERTY LINE E -210 Second Floor Electrical Power Plan HC. HOLLOW CORE WD. WOOD NOTE: SUBSTITUTIONS TO PRODUCTS ABOVE MUST BE APPROVED BY OWNER AND ARCHITECT E -220 Third Floor Electrical Power Plan HEW. HARDWARE W/0 WITHOUT . ---" HM. HOLLOW METAL WWF WIRE WELDED FABRIC 5' -0• DIAMETER TURNING RADIUS E -23® Fourth Floor Electrical Power Plan 600 E -240 Fifth Floor Electrical Power Plan CLEAR All E -250 Sixth Floor Electrical Power Plan E -260 Electrical Room Plan, Roof Electrical Plan and Panel Schedule List of Consultants Architecture: FORBES ARCHITECTS 4565 PONCE DE LEON BOULEVARD CORAL GABLES, FL 33146 305.446.0849 Structural: DDA ENGINEERS, PA 4930 SW 74TH COURT MIAMI, FL 33155 305.666.0711 Mechanical & Electrical: PUGA AND ASSOCIATES, INC. 7326 SW 48TH STREET MIAMI, FL 33155 305.661.7700 PARKING SUMMARY: 02 -22 -12 Commission 1. EMPLOYEES REQUIRED: 858 SPACES XXX SPACES (BUSINESS) XX,XXX SF /300 = XXX SPACES (STORAGE) 10,000 SF /1,000 = XXX SPACES (STORAGE) XX,XXX SF /2,000 = XXX SPACES ACCESSIBLE PARKING PROVIDED: XXX SPACES PROVIDED: SPACE XXX SPACES STANDARD XXX SPACES ACCESSIBLE EMPLOYEE GARAGE XXX SPACES Project Summary Project Description: SELECTIVE REFURBISHMENTS TO AN EXISTING PARKING GARAGE. ,Parking Summary: � to PLUMBING FIXTURES PROVIDED: TOTAL 1 2 - 2 MALE 1 X 1 FEMALE 1 - 1 IV "Wr IV Life Safety Notes: 02 -22 -12 Commission 1. EMPLOYEES 2,575/3 = 858 SPACES Occupancy and Occupant Load: DURING WORK SCOPE. THE STRUCTURE HAS THREE STAIR 2. THIS BUILDING IS EQUIPPED WITH A FIRE ALARM SYSTEM EMPLOYEE GARAGE ACCESSIBLE O 2% 792 X .02 = 16 SPACLO IMPROVEMENT AREA: 245,628 SF OCCUPANCY: GROUP S -2: STORAGE PER THE 2007 FFPC CHAPTER 43.1.1, THIS PROJECT IS A TIME. WHILE MAINTAINING ACCESS TO THE OTHER TWO CLASSIFIED AS A REPAIR, RENOVATION AND MODIFICATION. WITH INCIDENTAL OFFICE PARKING PROVIDED: THE DURATION OF THE CONSTRUCTION OF THE PROJECT A 903 SPACES THE EMPLOYEE PARKING STRUCTURE WILL BE OCCUPIED SPACE DURING THE PROPOSED WORK SCOPE. THE AREAS BEING WITHOUT ENTERING AN AREA BARRICADED FOR CONSTRUCTION (GROUP S -2) ACTIVITIES. EMPLOYEE GARAGE 792 SPACES LEVEL 1 41,192 SF /500 = 83 PEOPLE EMPLOYEE EMERGENCY /RADIATION/ RE -ENTRY TO THE VARIOUS PARKING LEVELS LEVEL 2 42,813 SF /500 = 86 PEOPLE ONCOLOGY SURFACE PARKING 111 SPACES LEVEL 3 42,813 SF /500 = 86 PEOPLE • LEVEL 4 42,813 SF /500 = 86 PEOPLE EMPLOYEE PARKING GARAGE: LEVEL 5 42,813 SF /500 = 86 PEOPLE PROVIDED EXISTING EXISTING EXISTING LEVEL 6 33,184 SF /500 = 67 PEOPLE LEVEL STANDARD COMPACT ACCESSIBLE • FIRST 88 40 2 SECOND 101 38 2 Plumbing Fixture Count: THIRD 99 38 3 FOURTH 98 38 3 1 PLUMBING FIXTURES REQUIRED: # OF PEOPLE DF WC UR LAV TOTAL 17 1 2 - 2 FIFTH 99 38 3 MALE 1 X 1 SIXTH 81 18 3 FEMALE 1 - 1 SUB -TOTAL 566 210 16 TOTAL 792 %_ w w w PLUMBING FIXTURES PROVIDED: TOTAL 1 2 - 2 MALE 1 X 1 FEMALE 1 - 1 IV "Wr IV Life Safety Notes: 02 -22 -12 Commission 1. THIS BUILDING IS NM EQUIPPED WITH A SPRINKLER SYSTEM 5. THE EMPLOYEE PARKING STRUCTURE WILL BE OCCUPIED 04 -24-12 ADDENDUM #2 a DURING WORK SCOPE. THE STRUCTURE HAS THREE STAIR 2. THIS BUILDING IS EQUIPPED WITH A FIRE ALARM SYSTEM TOWERS, ONE AT EACH VERTEX OF THE TRIANGULAR SHAPED STRUCTURE. THE GC SHALL WORK ON ONE STAIR TOWER AT 3. PER THE 2007 FFPC CHAPTER 43.1.1, THIS PROJECT IS A TIME. WHILE MAINTAINING ACCESS TO THE OTHER TWO CLASSIFIED AS A REPAIR, RENOVATION AND MODIFICATION. STAIR TOWERS. IN ADDITION, THE GC SHALL. MAINTAIN FOR Sheet THE DURATION OF THE CONSTRUCTION OF THE PROJECT A 4. THE EMPLOYEE PARKING STRUCTURE WILL BE OCCUPIED CLEAR PATH AND SIGNAGE FOR OCCUPANTS TO EGRESS DURING THE PROPOSED WORK SCOPE. THE AREAS BEING WITHOUT ENTERING AN AREA BARRICADED FOR CONSTRUCTION WORKED ON WILL BE TEMPORARILY BARRICADED OFF FROM ACTIVITIES. ACCESS TO THE EMPLOYEES/VEHICLES WHILE WORK IS ONGOING. THE PROPOSED WORK DOES NOT CREATE A 6. ALL STAIR TOWER DOOR HARDWARE SHALL ALLOW FOR HIGHER HAZARD LEVEL THEN THE OCCUPIED PORTION OF RE -ENTRY TO THE VARIOUS PARKING LEVELS THE BUILDING: THEREFORE, A RATED SEPARATION INDICATED t IN FFPC 1 :16.4.2.1 IS NOT REQUIRED coj- `i. ��EK ma�. _ #: cent» Location Map nts F.ORBES ARCHITECTS architecture land planning retail design apace planning construction management 4565 ponce de loon blvd. suite 100 coral gables, florida 33146 te1 :305.446.0649 fa x: 305 444 5557 fIorlde registration no. AA - F000104 e • e • e a e e 0 • • • • e a • e a • • s • • • e • • e • • • e • e V • • • • • s e • • • e a a tjO � . A �` .pP4, I John Roberts Forbes AR0009810 OV093MW AM USE OF THE DOCUMENTS THESE ORAUTII M SCHEDUI= SPECIFICATIONS AM DRESSED IDEAS AS INSTRUMENTS OF SERVICE ARE AM SHALL REMAIN THE PROPERTY OF FORBES ARCHITECTS WHETHER THE PROJECT FOR WHICH THEY ARE PREPARED IS E7ECU7M OR NOT. THE OWNER AIO/OR TENANT SHAH. ONLY BE N•Di►lTTED TO AM COPES OF THESE DRAWINM SCHEIX XS SPECIFICATIONS AM DIPRESSED IDEAS FOR IFORI4ATION AM REFERENCE. THE DRAWINGS. SCHEDULES. SPECIFICATIONS AM DIPRESSED IDEAS SHALL NOT BE USED BY THE OWNER AM/OR TENANT 04 OTHER PROJECTS. FOR ADDITIONS TO THIS PROJECT OR FOR COMPLE7101 OF THE PROJECT BY OTHERS EXCEPT BY AC12MI NT IN WRITING AM WITH APPROPRIATE COAF'EN511 TO FORBES ARCHITECTS. COPTRKd4TM 20,2..IDHI4 FORBES. let;.., dba FORBES ARCHITECTS. ALL RIGHTS RESERVED. "so Z� I t 1 co o Q o c LL E: CO E m TD 0 0 T: c 3 0 02 -22 -12 Commission 11070 Revisions 04 -24-12 ADDENDUM #2 a 05- 14-12 MD FIRE 4 03 -04-13 Sheet 1 of 1 i t • • "so Z� I t 1 co o Q o c LL E: CO E m TD 0 0 T: c 3 0 02 -22 -12 Commission 11070 Revisions 04 -24-12 ADDENDUM #2 a 05- 14-12 MD FIRE a 03 -04-13 Sheet 1 of 1