12-559-029U.N.O. - UNLESS OTHERWISE NOTED LIGHTING FIXTURE SCHEDULE TYPE ELECTRICAL SYMBOL TABLE VOLTS SYMBOL DESCRIPTION REMARKS SYMBOL TYPE DESCRIPTION EMCO DUPLEX RECEPTACLE -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED 277 17 TELEPHONE OUTLET -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED S2 20 AMP /125 VOLT ECA232- QVRNC- 1 000PSMH- QUAD -NP 20' ROUND TAPERED ALUM POLE 277 2 -EMPTY 3/4°" EMT STUBBED ABOVE CEILING W/ BUSHING POLE BASE SHALL MATCH EXISTING BOLT CIRCLE DIAMETER AND SHALL BE INSTALLED OVER EXISTING ANCHOR BOLTS DUPLEX RECEPTACLE - SWITCHED RECEPTACLE SEC - EDG - 4MB- WM- 10- D- UL -SV- 525 -40K 1; 7 DATA /PHONE OUTLET -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED LED 20 AMP /125 VOLT AS PER PLANS DAYBRITE v SURFACE -EMPTY 3/4'° EMT STUBBED ABOVE CEILING W/ BUSHING 0 DUPLEX RECEPTACLE - VERIFY MOUNTING HEIGHT S5 DAYBRITE TELEPHONE JUNCTION BOX -EMPTY 1.25" EMT STUBBED ABOVE CEILING W/ BUSHING 277 20 AMP /125 VOLT LED MOUNT IN EXISTING LOCATIONS S6 WALL MOUNT SEC -EDG- 4MB- WM- 12- D- UL -SV- 350 -40K WALL SURFACE GFCI DUPLEX RECEPTACLE - VERIFY MOUNTING HEIGHT LED O DATA JUNC11ON BOX -EMPTY 1.25" EMT STUBBED ABOVE CEILING W/ BUSHING BS100T5HO- 4- SA -254W- 120/207 20 AMP /125 VOLT 277 2 F54T5HO WALL MOUNT UNLESS OTHERWISE NOTED. INFINITY WEATHER- RESISTANT GFCI DUPLEX RECEPTACLE - VERIFY MOUNTING HEIGHT 277 © POWER JUNCTION BOX - CONNECT TO ELECTRICAL PANEL AS PER PLANS GFCl/WfR/W.P. 20 AMP 125 VOLT PROVIDE WEATHERPROOF ENCLOSURE SURFACE 277 WALL MOUNT 26W DDT OD DUPLEX RECEPTACLE - DEDICATED CIRCUIT, SEPARATE NEUTRAL - ALL ELECTRICAL EQUIPMENT AND MATERIALS SHALL BE APPROVED - ALL UNDERGROUND CONDUIT INSTALLATIONS SHALL COMPLY WITH JUNCTION BOX - VERIFY MOUNTING HEIGHT APPLICATION, AS DETERMINED BY AN ORGANIZATION CURRENTLY 20 AMP /125 VOLT RUN #12 GROUND WIRE BACK TO PANEL BEGHELLI VA4 -G -SA 4" X 4" 277 (�} ` I.G. DUPLEX RECEPTACLE 20 AMP /125 VOLT - ISOLATED CIRCUIT, LEVITON #5362 -IG RUN GROUND WIRE BACK TO PANEL X2 (-1 TELEVISION OUTLET -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED 277 1 - #12 WET LOCATION EXIT SIGN (GREEN LETTERS) T - PROVIDE EXPANSION JOINTS WHERE REQUIRED AS PER NEC -EMPTY 3/4" EMT STUBBED ABOVE CEILING W/ BUSHING 300.7(6). QUAD RECEPTACLE -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED 13- 413.AB.1.2 REGARDLESS OF SIZES SHOWN ON PLANS OR FPI POWER POLE -SIZE AND HEIGHT TO MATCH CEILING REQUIREMENTS 20 AMP /125 VOLT - AS PER F.B.C. 13- 413.AB.2.1, WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL - ALL DEDICATED OUTLETS SERVING EQUIPMENT SUCH AS DUAL CHANNEL FOR POWER AND DATA REFRIGERATORS, WATER COOLERS, COPIERS, FAXES, ETC. SHALL GFCI QUAD RECEPTACLE - VERIFY MOUNTING HEIGHT 1. 1. A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL �1 DISCONNECT -SIZED AND FUSED AS PER EQUIPMENT 2• FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR 20 AMP /125 VOLT ALL DISTRIBUTION. (WHITE DECORA) OR EQUAL AS APPROVED BY ARCHITECT OR ENGINEER. NAMEPLATE RATING SINGLE RECEPTACLE -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED THE BUILDING OWNER. THE MANUALS SHALL INCLUDE, AT A �I MOTOR STARTER - VERIFY HEATER STRIP SIZE WITH EQUIPMENT 1. SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED 20 AMP /125 VOLT VOLTAGE AND AMPACITY AS PER PLANS FIRE RATED WALLS. THIS INCLUDES MAINTAINING A MINIMUM 24" MAINTENANCE. SEPARATION BETWEEN ELECTRICAL DEVICES MOUNTED ON OPPOSITE 2. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH SIDES OF ALL FIRE RATED PARTITIONS AND WALLS. CLOCK HANGER RECEPTACLE - VERIFY MOUNTING HEIGHT ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY �D VARIABLE FREQUENCY - PROVIDED BY MECHANICAL CONTRACTOR C 20 AMP /125 VOLT SERVICE AGENCY. - ELECTRICAL CONTRACTOR SHALL COORDINATE WORK WITH THE - IF ANY CONFLICT IS ENCOUNTERED WITHIN THE DESIGN DRIVE DOCUMENTS, REGARDLESS OF TRADE OR RESPONSIBILITY, THE lT1 EQUIPMENT RECEPTACLE -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED PER. PLANS - CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECT • •� PIN- AND - SLEEVE RECEPTACLE - VERIFY NUMBER OF POLES AND REQUIREMENTS WITH AFTER ACCEPTANCE OF THE PROJECT. 120/208/277/480 VOLT VOLTAGE AND AMPACITY AS ELECTRICAL WIRING DEVICES (INCLUDING LUMINAIRES, RECEPTACLES, SWITCHES, CONDUITS, WIRING, ETC.) WITH OTHER TRADES TO AVOID EQUIPMENT. PROVIDE PLUG FOR EQUIPMENT. CONFLICTS. SWITCH, SINGLE POLE 20 AMP /120 -277 VOLT -MOUNT 44" A.F.F. UNLESS OTHERWISE NOTED �/ EXHAUST FAN /MOTOR -SEE MECHANICAL DRAWINGS FOR DETAILS SWITCH, DOUBLE POLE -MOUNT 44" A.F.F. UNLESS OTHERWISE NOTED LC LIGHTING CONTACTOR - VERIFY NUMBER OF POLES OP 20 AMP /120 -277 VOLT SWITCH, THREE -WAY -MOUNT 44'" A.F.F. UNLESS OTHERWISE NOTED FK CARD READER / KEYPAD - JUNCTION BOX AND EMPTY 3/4" EMT STUBBED ABOVE CEILING W/ BUSHING. VERIFY EXACT MOUNTING HEIGHT 20 AMP /120 -277 VOLT AND LOCATION WITH SECURITY CONSULTANT. $4 SWITCH, FOUR -WAY -MOUNT 44°" A.F.F. UNLESS OTHERWISE NOTED INTERCOM - JUNCTION BOX AND EMPTY 3/4" EMT STUBBED ABOVE CEILING W/ BUSHING. VERIFY EXACT MOUNTING HEIGHT 20 AMP /120 -277 VOLT AND LOCA11ON WITH SECURITY CONSULTANT, SWITCH, DIMMER -SIZE DIMMER WITH TOTAL LAMP WATTAGE Fs-1 DEVICE - JUNCTION BOX AND EMPTY 3/4" EMT STUBBED ABOVE CEILING W/ BUSHING. VERIFY EXACT MOUNTING HEIGHT 0 120 -277 VOLT AND LOCATION WITH SECURITY CONSULTANT. SWITCH, FAN DIMMER -SIZE DIMMER WITH TOTAL MOTOR LOAD MONITOR CAMERA - JUNCTION BOX AND EMPTY 1.0" EMT STUBBED ABOVE CEILING W BUSHING. VERIFY EXACT MOUNTING HEIGHT R 120 VOLT RHEOSTAT AND LOCATION WITH SECURITY CONSULTANT. $m SWITCH, MOTOR RATED -RATED FOR USE WITH TOTAL MOTOR LOADS ALARM CONTACTS 120 -277 VOLT AMPS RATING SHALL MATCH OVERCURRENT PROTECTION $K SWITCH, KEY 20 AMP /120 -277 VOLT -AS MANUFACTURED BY "LEVITON" Q DOOR BUZZER MODEL #1221 -2L / 55500 $TS TIME SWITCH OVERRIDE MAXIMUM SETTING OF 4 HOURS -SEE PANEL SCHEDULE FOR SPECIFICATION LOW VOLTAGE CEILING MOUNTED SPEAKERS $* DIMMING PANEL OVERRIDE - DEVICE MUST BE IDENTIFIED TO BE COMPATIBLE F DENOTES FLOOR OR ROOF MOUNT MAXIMUM SETTING OF 4 HOURS WITH DIMMING/LIGHTING CONTROL PANEL L -J $0 SWITCH, OCCUPANCY SENSOR -AS MANUFACTURED BY "SENSOR SWITCH" ( ^1 DENOTES CEILING MOUNT 20 AMP /120 -277 VOLT MODEL #WSD -PDT, PIR /MICROPHONICS, U.N.O. $0/2P SWITCH, OCC. SENSOR, 2 -POLE 20 AMP /120 -277 VOLT -AS MANUFACTURED BY "SENSOR SWITCH" (� DENOTES CORD DROP DEVICE -VERIFY MOUNTING HEIGHT MODEL #WSD - PDT -2P, PIR /MICROPHONICS, U.N.O. `C SWITCH, OCC, SENSOR, 2 -POLE, FAN -AS MANUFACTURED BY "SENSOR SWITCH" 0 /2P/FAN 20 AMP /120 -277 VOLT MODEL #WSD- PDT -2P -FAN, PIR /MICROPHONICS, U.N.O. $O SWITCH, OCC. SENSOR, SEMI AUTO. -AS MANUFACTURED BY "SENSOR SWITCH" /SA 20 AMP /120 -277 VOLT MODEL #WSD - PDT -SA, PIR /MICROPHONICS, U.N.O. SWITCH, VACANCY SENSOR -AS MANUFACTURED BY "SENSOR SWITCH" VA 20 AMP /120 -277 VOLT MODEL #WSD- PDT -VA, PIR /MICROPHONICS, U.N.O. n OCCUPANCY SENSOR, CORRIDOR -AS MANUFACTURED BY "SENSOR SWITCH" m 20 AMP /120 -277 VOLT MODEL #HWR -13, PIR, U.N.O. OCC. SENSOR, WIDE VIEW, CORNER -AS MANUFACTURED BY "SENSOR SWITCH" 20 AMP /120 -277 VOLT MODEL #WVR- PDT -16, PIR, U.N.O. (� OCCUPANCY SENSOR, CEILING -AS MANUFACTURED BY "SENSOR SWITCH" �-' 20 AMP /120 -277 VOLT MODEL #CMR- PDT -10, PIR /MICROPHONICS, U.N.O. 0 /2p OCCUPANCY SENSOR, CEILING, -AS MANUFACTURED BY "SENSOR SWITCH" ��✓/ 2 -POLE, 20 AMP /120 -277 VOLT MODEL #CMR- PDT- 10 -2P, PIR /MICROPHONICS, U.N.O. �Lv OCCUPANCY SENSOR, CEILING -AS MANUFACTURED BY "SENSOR SWITCH" LOW VOLTAGE MODEL #CM- PDT -10, PIR /MICROPHONICS, U.N.O. �HB OCCUPANCY SENSOR, HIGH BAY -AS MANUFACTURED BY "SENSOR SWITCH" `-� 20 AMP /120 -277 VOLT MODEL #CMR -6, PIR, U.N.O. s HBAV `-� OCCUPANCY SENSOR, HIGH BAY -AS MANUFACTURED BY "SENSOR SWITCH" LOW VOLTAGE MODEL #CM -6, PIR, U.N.O. OC -PP POWER PACK -AS MANUFACTURED BY "SENSOR SWITCH" 20 AMP /120 -277 VOLT MODEL #PP -20, U.N.O. 66-2P POWER PACK, 2 -POLE -AS MANUFACTURED BY "SENSOR SWITCH" 20 AMP /120 -277 VOLT MODEL #PP- 20 -2P, U.N.O. U.N.O. - UNLESS OTHERWISE NOTED LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER CATALOG NUMBER MOUNTING VOLTS BUILDING CODE (F.B.C.) WITH LATEST SUPPLEMENTS & LAMPS REMARKS QTY TYPE S1 EMCO ECA231- QVRNC-1000PSMH- QUAD -NP 20' ROUND TAPERED ALUM POLE 277 1 100OW PS MH POLE BASE SHALL MATCH EXISTING BOLT CIRCLE DIAMETER AND SHALL BE INSTALLED OVER EXISTING ANCHOR BOLTS S2 EMCO ECA232- QVRNC- 1 000PSMH- QUAD -NP 20' ROUND TAPERED ALUM POLE 277 2 100OW PS MH POLE BASE SHALL MATCH EXISTING BOLT CIRCLE DIAMETER AND SHALL BE INSTALLED OVER EXISTING ANCHOR BOLTS S3 BETALED SEC - EDG - 4MB- WM- 10- D- UL -SV- 525 -40K WALL MOUNTED AT 12' A.F.F. 277 - LED WALL MOUNTED FIXTURE S4 DAYBRITE FS19OWLU- MHP -AL SURFACE 277 - LED WALL MOUNTED TWIN FLOODLIGHT FOR COURTYARD S5 DAYBRITE WTM40WLUSC2 -AL WALL SURFACE 277 - LED MOUNT IN EXISTING LOCATIONS S6 BETALED SEC -EDG- 4MB- WM- 12- D- UL -SV- 350 -40K WALL SURFACE 277 - LED MOUNT IN EXISTING LOCATIONS A BEGHELLI BS100T5HO- 4- SA -254W- 120/207 SURFACE 277 2 F54T5HO 4' NON METALLIC FLUORESCENT FIXTURE B INFINITY PH75- 213Q- CS- MWT- EB2- UNV -RETRO RECESS 277 2 13W DDT REMODEL COMPACT FLUORESCENT DOWNLIGHT C BETA CALCO 15- 1904 -OP -WH SURFACE 277 2 26W DDT ROUND CEILING LIGHT m cc - ALL ELECTRICAL EQUIPMENT AND MATERIALS SHALL BE APPROVED - ALL UNDERGROUND CONDUIT INSTALLATIONS SHALL COMPLY WITH AS SAFE FOR USE IN THE U.S. WORKPLACE FOR THE INTENDED NEC SECTION 300.5. APPLICATION, AS DETERMINED BY AN ORGANIZATION CURRENTLY > Q X1 BEGHELLI VA4 -G -SA UNIVERSAL 277 - LED DAMP LOCATION EXIT SIGN (GREEN LETTERS) X2 BEGHELLI FTZ- SA- LG- U -U -WW UNIVERSAL 277 1 - ILED WET LOCATION EXIT SIGN (GREEN LETTERS) GENERAL ELECTRICAL NOTES - ALL ELECTRICAL WORK PERFORMED UNDER THIS CONTRACT SHALL - ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC) 2008, SUSPENSION SYSTEMS FOR SELECTION OF THE PROPER TRIM AND LOCAL CODES AND ORDINANCES (INCLUDING THE 2007 FLORIDA SUPPORT ARRANGEMENTS OF ALL ELECTRICAL DEVICES. BUILDING CODE (F.B.C.) WITH LATEST SUPPLEMENTS & AMENDMENTS), AND ALL STANDARDS OF CONSTRUCTION - PROVIDE ACCESS PANELS AS REQUIRED TO SERVICE ALL ESTABLISHED BY THE LANDLORD. ELECTRICAL EQUIPMENT ABOVE HARD CEILINGS. COORDINATE WITH ARCHITECT BEFORE ROUGH INSTALLATION. - PRIOR TO BID OR COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VISIT THE JOB SITE AND EVALUATE ALL EXISTING FIELD - WHERE APPLICABLE, ALL LUMINAIRES SHALL BE PROPERLY CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OR SECURED TO CEILING GRID SYSTEM. ENGINEER OF ANY DISCREPANCIES. THE CONTRACTOR SHALL QUALIFY THE BID ACCORDINGLY. - LUMINAIRES THAT USE A METAL HALIDE LAMP OTHER THAN A THICK -GLASS PARABOLIC REFLECTOR LAMP (PAR) SHALL BE - THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR PROVIDED WITH A CONTAINMENT BARRIER THAT ENCLOSES THE ACCEPTANCE BY THE ARCHITECT AND /OR ENGINEER BEFORE LAMP, OR SHALL BE PROVIDED WITH A PHYSICAL MEANS THAT °0" PROCEEDING WITH THE PURCHASE OR INSTALLATION OF THE ONLY ALLOWS THE USE OF A LAMP THAT IS TYPE IN EQUIPMENT AND MATERIALS. NO FACSIMILES OR FACSIMILE COPIES ACCORDANCE WITH NEC 410.130(F)(5). SHALL BE ACCEPTED. - FLUORESCENT LUMINAIRES THAT UTILIZE DOUBLE -ENDED LAMPS - THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER AND CONTAIN BALLAST(S) THAT CAN BE SERVICED IN PLACE OR PRIOR TO CUTTING OR DRILLING ANY STRUCTURAL SUPPORT BALLASTED LUMINAIRES THAT ARE SUPPLIED FROM MULTIWIRE MEMBER. BRANCH CIRCUITS AND CONTAIN BALLAST(S) THAT CAN BE SERVICED IN PLACE SHALL HAVE A DISCONNECTING MEANS IN - THE CONTRACTOR SHALL SATISFACTORILY REPAIR /REPLACE ANY ACCORDANCE WITH NEC 410.130(G), WHERE APPLICABLE. EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF WORK PERFORMED. SURFACES AND FINISHED AREAS SHALL BE - ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE RESTORED TO MATCH ADJACENT AREAS. WITH THE CEILING SYSTEM MANUFACTURER RECOMMENDA11ONS AND LOCAL CODE REQUIREMENTS. - ALL CONDUCTORS SHALL BE THWN OR THHN COPPER. - ALL LIGHTING CIRCUITS WHICH CONTROL AND /OR OPERATE - METAL -CLAD (MC) CABLE SHALL NOT BE USED IN ANY PORTION LIGHTING FIXTURES WITH AN ELECTRONIC BALLAST SHALL BE OF THE INSTALLATION UNLESS PRIOR WRITTEN CONSENT IS PROVIDED WITH A SEPARATE NEUTRAL WIRE PER EACH PHASE. OBTAINED FROM THE OWNER, ARCHITECT AND ENGINEER. - ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL LIGHT - ALL OPEN WIRING ABOVE A SUSPENDED CEILING SYSTEM USED AS FIXTURE QUANTITIES AND MEASUREMENTS (LENGTHS) ON PLANS A RETURN AIR PLENUM SHALL BE RATED FOR USE IN A RETURN PRIOR TO SUBMITTAL OF SHOP DRAWINGS. AIR PLENUM. ALL CABLING SHALL COMPLY WITH N. F. P. A. STANDARDS. - EACH MULTIWIRE BRANCH CIRCUIT SHALL BE PROVIDED WITH A MEANS WHAT WILL SIMULTANEOUSLY DISCONNECT ALL - ALL EXPOSED CONDUITS SHALL BE RUN AS NEAT AS POSSIBLE. UNGROUNDED CONDUCTORS AT THE POINT WHERE THE BRANCH P.V.C. CONDUIT SHALL ONLY BE USED IN SLAB OR UNDERGROUND CIRCUIT ORIGINATES AS PER NEC 210.4(B). AT A MINIMUM DEPTH OF 24 INCHES. m cc - ALL ELECTRICAL EQUIPMENT AND MATERIALS SHALL BE APPROVED - ALL UNDERGROUND CONDUIT INSTALLATIONS SHALL COMPLY WITH AS SAFE FOR USE IN THE U.S. WORKPLACE FOR THE INTENDED NEC SECTION 300.5. APPLICATION, AS DETERMINED BY AN ORGANIZATION CURRENTLY > Q RECOGNIZED BY OSHA (OCCUPATIONAL SAFETY AND HEALTH) AS A - ALL UNDERGROUND CONDUITS SHALL BE CONVERTED TO E.M.T. NRTL (NATIONALLY RECOGNIZED TEST LABORATORY ). (E.G. - UL, CONDUIT ABOVE SLAB LEVEL. ALL UNDERGROUND ELBOWS SHALL CST, ETC.) BE R.G.S. CONDUIT, cc - PROVIDE PULL STRINGS IN ALL EMPTY CONDUITS. - AS PER F.B.C. 13- 413.AB.1.1, FEEDER AND CUSTOMER -OWNED i SERVICE CONDUCTORS SHALL BE SIZED FOR A MAXIMUM VOLTAGE - ALLOW NO MORE THAN THE EQUIVALENT OF FOUR QUARTER DROP OF 2 PERCENT AT DESIGN LOAD REGARDLESS OF SIZES BENDS (360 DEGREES TOTAL) BETWEEN ALL PULL POINTS, E.G., SHOWN ON PLANS OR PANEL SCHEDULES. CONDUIT BODIES AND BOXES AS PER NEC 344.26. - ALL . BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED IN - PROVIDE EXPANSION JOINTS WHERE REQUIRED AS PER NEC ACCORDANCE WITH N.E.C. 210.19 AND FOR A MAXIMUM VOLTAGE 300.7(6). DROP OF 3 PERCENT AT DESIGN LOAD AS PER F.B.C. 13- 413.AB.1.2 REGARDLESS OF SIZES SHOWN ON PLANS OR PANEL SCHEDULES. - FLEXIBLE CONDUIT SHALL BE USED FOR CONNECTION TO ALL VIBRATING EQUIPMENT SUCH AS MOTORS, ETC. - AS PER F.B.C. 13- 413.AB.2.1, WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL - ALL DEDICATED OUTLETS SERVING EQUIPMENT SUCH AS INSTALLATION SHALL BE PROVIDED BY THE GENERAL CONTRACTOR REFRIGERATORS, WATER COOLERS, COPIERS, FAXES, ETC. SHALL THE BUILDING OWNER, INCLUDING. HAVE SEPARATE NEUTRAL CONDUCTORS TO EACH DEVICE OR 1. 1. A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL APPLIANCE. DISTRIBUTION SYSTEM AND 2• FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR - ALL WIRING DEVICES SHALL BE LEVITON COMMERCIAL GRADE ALL DISTRIBUTION. (WHITE DECORA) OR EQUAL AS APPROVED BY ARCHITECT OR ENGINEER. - AS PER F.B.C. 13- 413.AB.2.2, THE GENERAL CONTRACTOR SHALL PROVIDE AN OPERATING MANUAL AND MAINTENANCE MANUAL TO -', ALL RECEPTACLES SHALL BE INSTALLED AT 18 A.F.F. UNLESS THE BUILDING OWNER. THE MANUALS SHALL INCLUDE, AT A OTHERWISE NOTED, MINIMUM, THE FOLLOWING: 1. SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED - ! MAINTAIN FIRE RATING IN ALL PENETRATIONS THRU DEMISING AND OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING FIRE RATED WALLS. THIS INCLUDES MAINTAINING A MINIMUM 24" MAINTENANCE. SEPARATION BETWEEN ELECTRICAL DEVICES MOUNTED ON OPPOSITE 2. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH SIDES OF ALL FIRE RATED PARTITIONS AND WALLS. PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY - ELECTRICAL POWER AND CONTROL WIRING FOR H,V.A.C. AND IDENTIFIED. MECHANICAL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY 3. NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED THE ELECTRICAL CONTRACTOR. SERVICE AGENCY. - ELECTRICAL CONTRACTOR SHALL COORDINATE WORK WITH THE - IF ANY CONFLICT IS ENCOUNTERED WITHIN THE DESIGN ARCHITECTURAL PLANS BEFORE ROUGH INSTALLATION OF LIGHTS, DOCUMENTS, REGARDLESS OF TRADE OR RESPONSIBILITY, THE RECEPTACLES, SWITCHES, AND .EQUIPMENT FOR EXACT LOCATION. GREATER SCOPE OF WORK SHALL PREVAIL - ELECTRICAL CONTRACTOR SHALL VERIFY EXACT DIMENSIONS AND - CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECT LOCATIONS OF ALL EQUIPMENT WITH TENANT PRIOR TO ROUGH IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR INSTALLATION. AFTER ACCEPTANCE OF THE PROJECT. -'!' ELECTRICAL CONTRACTOR SHALL COORDINATE LOCATIONS OF ALL ELECTRICAL WIRING DEVICES (INCLUDING LUMINAIRES, RECEPTACLES, SWITCHES, CONDUITS, WIRING, ETC.) WITH OTHER TRADES TO AVOID CONFLICTS. D 01 Ili i THE DESIGNATED NUMBERS ARE SHOWN ON THESE PLANS AS PER A PREVIOUS FIELD INSPECTION TO DETERMINE THE POSSIBLE SPACES OR SPARES IN THE EXISTING PANEL. CONTRACTOR SHALL SHOW THE CIRCUIT NUMBERS ACTUALLY USED IN THE INSTALLATION ON THE "AS- BUILT" DRAWINGS. THE EXISTING TENANT SPACE HAS SEVERAL ELECTRICAL DEVICES AND /OR LIGHT FIXTURES IN AREA OF DEMOLITION TO BE REMOVED. ALL RE- USABLE DEVICES AND LIGHT FIXTURES SHALL BE RETURNED TO BUILDING OWNER. PRIOR TO BID, CONTRACTOR SHALL VISIT THE JOB SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS. THE DEMOLITION OF ALL ELECTRICAL DEVICES, INCLUDING THE REPAIR OF EXISTING DEVICES TO REMAIN SHALL BE INCLUDED IN THE BID PRICE. ELECTRICAL CONTRACTOR SHALL DISCONNECT POWER FROM AREA OF DEMOLITION AND MAKE THE AREA SAFE FOR DEMOLITION CREW. REPORT ANY DISCREPANCIES TO THE ARCHITECT OR ENGINEER PRIOR TO BID. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION DETAILS, REPORT ANY DISCREPANCIES TO THE ARCHITECT OR ENGINEER PRIOR TO BID. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION DETAILS. EXISTING EXIT AND EMERGENCY LIGHTS TO BE RE -USED SHALL BE TESTED FOR PROPER OPERATION OF LAMPS AND BATTERIES. REPLACE ANY DEFECTIVE COMPONENTS AS REQUIRED. EXISTING GARAGE PARKING AREA LIGHT FIXTURES TO BE CLEANED AND TESTED FOR PROPER OPERATION OF LAMPS AND BALLASTS. REPLACE ANY DEFECTIVE COMPONENTS AS REQUIRED. EXISTING STAIRWAY LIGHT FIXTURES TO BE CLEANED AND TESTED FOR PROPER OPERATION OF LAMPS AND BALLASTS. REPLACE ANY DEFECTIVE COMPONENTS AS REQUIRED. FIRE ALARM SHOP DRAWINGS, SIGNED AND SEALED, AS REQUIRED BY THE JURISDICTION HAVING AUTHORITY SHALL BE PROVIDED BY THE FIRE ALARM CONTRACTOR AND THEIR OWN RESPECTIVE ENGINEER. ALL WORK SHALL CONFORM TO THE FLORIDA BUILDING CODE AND ALL OTHER APPLICABLE STATE AND LOCAL REGULATIONS AND ORDINANCES. CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECT IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE PROJECT. �III J 9rc hitrcture ISnd ;�: nning retail design space planning ,�wQonstru Ction management �^ 4565-ponce de °loon "blvd. -surte 100 . coral gables, florida 33146 lot :305.446 ^0849 fax: 305.444.5557 florida registration no. AA - F000104 O O O O O a O O o a o a O a a a a a a a 0 O o 0 0 0 0 a a 0 0 0 0 a 0 e e a e 0 O O O O O 0 O O a O a a O 0 O a O O O O a O O O Puga and Associates, Inc. Engineers /Consultants # EB 0005813 7326 S.W. 48th Street }diem. Florida 33155 (305) 661 -7700 OWNERSHIP AND USE OF THE DOCUTAENTS: THESE DRAWINGS, SCHEDULES, SPECIFICATIONS AND EXPRESSED IDEAS AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE PROPERTY OF FORBES ARCHITECTS WHETHER THE PROJECT FOR WHICH THEY ARE PREPARED IS EXECUTED OR NOT. THE OWNER AND /OR TENANT SHALL ONLY BE PERMITTED TO RETAIN COPES OF THESE DRAWINGS, SCHEDULES, SPECIFICATIONS AND EXPRESSED IDEAS FOR INFORMATION AND REFERENCE. THE DRAWINGS, SCHEDULES. SPECIFICATIONS AND EXPRESSED IDEAS SHALL NOT BE USED BY THE OWNER AND /OR TENANT ON OTHER PROJECTS, FOR ADDITIONS TO THIS PROJECT OR FOR COMPLETION OF THE PROJECT BY OTHERS EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSAM TO FORBES ARCHITECTS. COPY�GHT C 2009, JOHN FORBES. INC., dba FORBES ARCHITECTS, ALL RIGHTS RESERVED. CD AZ M HD ch cr) CL > c In ¢ 0 0 v t% 14 o 0 fn rte. U) a`) c 3 Al ''� •�E Nsq h''y s 4 * _ 41163 , F 4'Lpl'LhNFs9l0 NA1.����r Date 11 -2 &11 Commission 11070 Revisions Sheet E-1 00 X of X L W W L w N � m cc — C C 'Ma, r co CL 1. O > Q J _ -0 c U- . T cc (00 E cc i U O U) O CD AZ M HD ch cr) CL > c In ¢ 0 0 v t% 14 o 0 fn rte. U) a`) c 3 Al ''� •�E Nsq h''y s 4 * _ 41163 , F 4'Lpl'LhNFs9l0 NA1.����r Date 11 -2 &11 Commission 11070 Revisions Sheet E-1 00 X of X