Loading...
12-559-012PROVIDE 3/4" PAINTED STUCCO FINISH AFTER DOOR FRAME IS REINSTALLED EXISTING PAINTED STUCCO FINISH EXISTING PAINTED CONCRETE FINISH EXISTING CONCRETE LINTEL FILL HEAD W/ GROUT & SECURE W/ 2 ANCHORS TO CONCRETE LINTEL CONTINUOUS CAULK TO MATCH WALL COLOR, TYPICAL HOLLOW METAL FRAME, WITH PAINT FINISH DOOR AS SCHEDULED CONT. SEALANT CAULK TO MATCH WALL COLOR, TYPICAL SLOPE STUCCO 1/4" 1 Door Head 3" A -7 PROVIDE 3/4" PAINTED STUCCO FINISH AFTER DOOR FRAME IS REINSTALLED DIMENSION PER DOOR SCHEDULE, CONTINUOUS CAULK TO MATCH FRAME COLOR, TYPICAL FILL JAMB WITH GROUT & SECURE WITH 3 ANCHORS TO CMU HOLLOW METAL DOOR FRAME WITH PAINT FINISH DOOR AS SCHEDULED CONTINUOUS SEALANT TO MATCH FRAME COLOR, TYPICAL STUCCO WITH PAINT FINISH 2 Door Jamb 3" A -7 Viols] ADA COMPLIANT THRESHOLD, PEMKO 2005 -T OR EQUAL EXISTING SLAB SET THRESHOLD IN CONTINUOUS BED OF SEALANT NO. 10 x 1 1/2" FHWS PHILLIPS SCREW 9- OF DOOR � Threshold Detail s° 1 9/16" IMPACT GLASS STOREFRONT SYSTEM IN CLEAR ANODIZED ALUMINUM FRAME FASTENED PER NOA, TYPICAL 3 X" X J" WD P.T. FRAME BEYOND FASTENED TO STEEL POST CONTINOUS SEALANT, TYPICAL BOTTOM CONNECTION 8" x 8" x 1/4" STEEL PLATE WELDED TO VERTICAL POST. RECESS TO MAKE FLUSH WITH FLOOR, SEE STRUCTURAL DRAWINGS BREAK METAL WITH FINISH TO MATCH MULLION VERTICAL STEEL POST 4 Jamb and Mullion Detail 3" A -7 EXISTING CONCRETE LINTEL EXISTING RIGID INSULATION EXISTING 5/8" GYPSUM BOARD WITH PAINT FINISH, PATCH AND MATCH ADJACENT FINISHES AS REQUIRED 1 X PT WOOD BUCK CONTINUOUS ATTACHMENTS ACCORDING TO NOA SPECIFICATIONS SEALANT CONTINUOUS NEW IMPACT WINDOW SYSTEM, SEE NOA SCHEDULE ON "I" SHEET EXISTING STUCCO WITH PAINT FINISH, PATCH AND MATCH ADJACENT FINISHES AS REQUIRED 5 Head Detail 30' A -7 Jamb Similar [I.1111:( 61 DOOR DOOR SIZE MATERIAL FINISH UC DETAILS LABEL DOOR HARDWARE DOOR NOTES REMARKS No. TYPE W. H. T. DOOR CORE FRAME DOOR FRAME JAMB HEAD SILL SET NO. LASER STOP 101 B 3' -0" 6' -8" 1 3/4" MTL. - MTL PAINT PAINT WALL/CEILING - A or B 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 102 A 3' -0" EXIST EXIST EXIST EXIST EXIST PAINT PAINT FLOOR - NONE REQ. EXIST EXIST EXIST EXIST - - 103 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME W/ PANIC HARDWARE 104 B 3' -0" 6' -8" 1 3/4" MTL. - MTL PAINT PAINT 2/A -7 1/A-7 3/A -7 NO. 1 CLOSER - PROVIDE ELECTRIC STRIKE ON DOOR FRAME 105 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W DOOR TO HAVE PANIC HARDWARE 106 NOT USED 107 C 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - NO. 3 CLOSER - 108 D 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - NO. 3 CLOSER - 109 C 2 -3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - NO. 3 CLOSER - 110 B 3' -0" 6' -8" 1 3/4" MTL. - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W DOOR TO HAVE PANIC HARDWARE 111 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 NO. 1 CLOSER - DOOR TO HAVE PANIC HARDWARE 201 B 3' -0" 6' -8" 1 3/4" MTL - MTL. PAINT PAINT 2/A -7 1/A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 202 B 3' -0" 6' -8" 1 3/4" MTL - MTL. PAINT PAINT 2/A -7 1 /A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 203 A 3' -0" EXIST EXIST EXIST EXIST EXIST PAINT PAINT EXIST EXIST EXIST EXIST - - 204 B 3' -0" 6' -8" 1 3/4" MTL - MTL. PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 205 B 3' -0" 6` -8" 1 3/4" EXIST EXIST EXIST PAINT PAINT 2/A -7 1/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 206 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 207 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 301 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 0 CD 302 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME t3 303 A 3' -0" EXIST EXIST EXIST EXIST EXIST PAINT PAINT EXIST EXIST EXIST EXIST - - L 304 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 0 305 B 3' -0" 6' -8" 13/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 306 B 3' -0" 6' -8" 1 3/4" MTL. - MTL PAINT PAINT 2/A -7 1/A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 307 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 401 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 402 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 403 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 404 B 3' -0" 6' -8" 1 3/4" MTL - MTL. PAINT PAINT 2/A -7 1/A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 405 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 406 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - 13-LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 501 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 502 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 503 B 3' -0" 6' -8" 1 3/4" MTL - MTL. PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 504 B 3' -0" 6' -8" 1 3/4" MTL. - MTL. PAINT PAINT 2/A -7 1 /A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 505 B 3' -0" 6' -8" 1 3/4" MTL - MTL. PAINT PAINT 2/A -7 1/A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 506 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 601 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 602 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1 /A -7 3/A -7 B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 603 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 604 B 3' -0" 6' -8" 1 3/4" MTL - MTL PAINT PAINT 2/A -7 1/A -7 - B -LABEL NO. 1 CLOSER W NEW 90 MINUTE FIRE RATED DOOR AND FRAME 605 E 3' -0" 7' -0" 1 3/4" ALUM GLASS ALUM ANOD. ANOD. 7/A -7 7/A -7 3/A -7 NO. 2 CLOSER - TRANSLUCENT GLASS BOTTOM CONNECTION 8" x 8" x 1/4" STEEL PLATE WELDED TO VERTICAL POST. RECESS TO MAKE FLUSH WITH FLOOR, SEE STRUCTURAL DRAWINGS BREAK METAL WITH FINISH TO MATCH MULLION VERTICAL STEEL POST 4 Jamb and Mullion Detail 3" A -7 EXISTING CONCRETE LINTEL EXISTING RIGID INSULATION EXISTING 5/8" GYPSUM BOARD WITH PAINT FINISH, PATCH AND MATCH ADJACENT FINISHES AS REQUIRED 1 X PT WOOD BUCK CONTINUOUS ATTACHMENTS ACCORDING TO NOA SPECIFICATIONS SEALANT CONTINUOUS NEW IMPACT WINDOW SYSTEM, SEE NOA SCHEDULE ON "I" SHEET EXISTING STUCCO WITH PAINT FINISH, PATCH AND MATCH ADJACENT FINISHES AS REQUIRED 5 Head Detail 30' A -7 Jamb Similar [I.1111:( 61 HARDWARE SET NO. 1 5 LOCKSET: PASSAGE TYPE C O OCCUPANCY EXITS HARDWARE SET NO. 2 OTHER SPACES 4 LOCKSET: SUITE ENTRY = A `0 BUSINESS - NEW D HARDWARE SET NO. 3 WALL/CEILING - A, B or C LOCKSET. STOREROOM TYPE BOTTOM CONNECTION 8" x 8" x 1/4" STEEL PLATE WELDED TO VERTICAL POST. RECESS TO MAKE FLUSH WITH FLOOR, SEE STRUCTURAL DRAWINGS BREAK METAL WITH FINISH TO MATCH MULLION VERTICAL STEEL POST 4 Jamb and Mullion Detail 3" A -7 EXISTING CONCRETE LINTEL EXISTING RIGID INSULATION EXISTING 5/8" GYPSUM BOARD WITH PAINT FINISH, PATCH AND MATCH ADJACENT FINISHES AS REQUIRED 1 X PT WOOD BUCK CONTINUOUS ATTACHMENTS ACCORDING TO NOA SPECIFICATIONS SEALANT CONTINUOUS NEW IMPACT WINDOW SYSTEM, SEE NOA SCHEDULE ON "I" SHEET EXISTING STUCCO WITH PAINT FINISH, PATCH AND MATCH ADJACENT FINISHES AS REQUIRED 5 Head Detail 30' A -7 Jamb Similar [I.1111:( 61 NEW IMPACT WINDOW SYSTEM, SEE NOA SCHEDULE ON "i" SHEET SEALANT CONTINUOUS EXISTING STUCCO ON WINDOW SILL TO BE REMOVED AND RE- STUCCOED AFTER INSTALLATION OF NEW WINDOW SYSTEM, NEW STUCCO TO BE PAINTED AND MATCH ADJACENT FINISHES AS REQUIRED ATTACHMENTS ACCORDING TO NOA SPECIFICATIONS EXISTING CONCRETE SILL EXISTING STUCCO WITH PAINT FINISH, PATCH AND MATCH ADJACENT FINISHES AS REQUIRED 6 Sill Detail 3° A -7 EQ. EQ. FLUSH DOOR FLUSH DOOR FIXED METAL WITH WIRE GLASS LOUVRE O Q. VISION PANEL A I- L O O d T 2'X2' FIXED STOREFRONT METAL LOUVRE DOOR 2007 NFPA 101 5 7.1.4, 10.2 and SPECIFIC OCCUPANCIES C O OCCUPANCY EXITS EXIT ACCESS CORRIDORS OTHER SPACES 4 EXISTING CONCRETE A CU BUSINESS - NEW WALL/CEILING - A or B WALL/CEILING - A or B WALL/CEILING - A, B or C 'Y) (NFPA 101 38.3.3) FLOOR - CLASS I or II FLOOR - CLASS I or II FLOOR - NONE REQ. L- NEW IMPACT WINDOW SYSTEM C0 IN EXISTING STRUCTURAL 0 5 BUSINESS - EXISTING WALL/CEILING - A or B WALL/CEILING - A or B WALL /CEILING - A, B or C CD — (NFPA 101 39.3.3) FLOOR - NONE REQ. FLOOR - NONE REQ. FLOOR - NONE REQ. X STORAGE WALL/CEILING - A or B WALL/CEILING - A or B WALL /CEILING - A, B or C ICU (NFPA 101 42.3.3) FLOOR - NONE REQ. FLOOR - NONE REQ. (STORAGE AREAS) FLOOR - NONE REQ. NEW IMPACT WINDOW SYSTEM, SEE NOA SCHEDULE ON "i" SHEET SEALANT CONTINUOUS EXISTING STUCCO ON WINDOW SILL TO BE REMOVED AND RE- STUCCOED AFTER INSTALLATION OF NEW WINDOW SYSTEM, NEW STUCCO TO BE PAINTED AND MATCH ADJACENT FINISHES AS REQUIRED ATTACHMENTS ACCORDING TO NOA SPECIFICATIONS EXISTING CONCRETE SILL EXISTING STUCCO WITH PAINT FINISH, PATCH AND MATCH ADJACENT FINISHES AS REQUIRED 6 Sill Detail 3° A -7 EQ. EQ. FLUSH DOOR FLUSH DOOR FIXED METAL WITH WIRE GLASS LOUVRE O Q. VISION PANEL A I- L O O d T 2'X2' FIXED STOREFRONT METAL LOUVRE DOOR 1. ALL DOOR FRAMES TO RECEIVE TWO COATS OF SEMI -GLOSS PAINT, SEE SPECIFICATIONS. COLOR TO BE SELECTED BY ARCHITECT. 2. EACH DOOR TO RECEIVE RUBBER WALL (W) OR FLOOR (F) BUMPERS AS INDICATED; US 32 FINISH (POLISHED STAINLESS STEEL) 3. ALL EXISTING CYLINDERS TO BE STORED AND RETURNED TO THE OWNER AFTER REPLACEMENT OF DOOR HARDWARE. CO O 4. ALL DOORS AND HARDWARE ARE TO COMPLY WITH THE FLORIDA 0 BUILDING CODE AND THE AMERICANS WITH DISABILITIES ACT. 5. DOORS AND FRAME TO MEET ALL DADE COUNTY REQUIREMENTS. `0 ALL EXTERIOR DOORS TO HAVE CURRENT NOTICE OF 0 ACCEPTANCE AND BE INSTALLED IN A COMPLIANT MANNER. 6. CONTRACTOR TO SUBMIT COMPLETE SHOP DRAWINGS OF ALL GLASS/ ALUMINUM DOORS AND ALL METAL DOORS AND FRAMES. 7. STOREFRONT DOOR TO BE ALUMINUM MEDIUM STYLE STOREFRONT DOOR WITH CLEAR ANODIZED FINISH. 9/16" IMPACT GLAS STOREFRONT SYSTE CLEAR ANODIZED AI FRAME, TYPICAL ALUMINUM STOREFF DOOR FRAME, TYPIC STOREFRONT DOOR FRAME, BEYOND 9/16" IMPACT GLA4 STOREFRONT SYSTEM IN CLEAR ANODIZED ALUMINUM FRAME, TYPICAL 7 Door Head 311 A -7 w AN Q I 7 FORBES AECH70TECTS architecture " land planning retail design - space- r1anninC --- "cons'.ruct,on n;"anaEernent 4 65 ^R ace- dell -ec^n b'vd. suite 100 coral gables, florida 33146 tel :305.446.0849 fax: 305.444.5557 florida registration no. AA -FOOO104 O O O O O O O O 4 O O O O O O O o e e 0 0 O o 0 O O 0 0 O 0 0 0 a a 0 O 0 O O 0 e 0 0 a a 0 e 0 a 0 O 0 O 0 0 0 0 0 0­0 0 . 0 a 0 O q,G• 0 c=, ..• r•` , i John Roberts Forbes AR0009810 OWNERSHIP AND USE OF THE DOCUMENTS: THESE DRAWINGS. SCHEDULES. SPECIFICATIONS AND EXPRESSED IDEAS AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE PROPERTY OF FORBES ARCHITECTS WHETHER THE PROJECT FOR WHICH THEY ARE PREPARED IS EXECUTED OR NOT. THE OWNER AND TENANT SHALL ONLY BE PERMITTED TO RETAIN COPIES OF THESE DRAWINGS. SCHEDULES, SPECIFICATIONS AND EXPRESSED IDEAS FOR INFORMATION AND REFERENCE. THE DRAWINGS,. SCEDIXES. SPECIFICATIONS AND EXPRESSED IDEAS SHALL NOT BE USED BY THE OWNER AND /oR TENANT ON OTHER PROJECTS. FOR ADDITIONS TO THIS PROJECT OR FOR COMPLETION OF THE PROJECT BY OTHERS EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSA TO FORBES ARCHITECTS. COPYRIGHT 2012, JOHN FMS. INC., aba FORBES ARCHITECTS. ALL RIGHTS RESERVED. v/ LM 0 ^- W CN W !� L �I N M O ? M O CL Q J U LL c� M w .E 'd O O O '- I�+ U) LL U m �4 a. Date I e a th v a� Cn co ;ra c es C > r- O Q o = v u- C EcE GT m a o fn° n fn° 0} 3 0 02 -22 -12 Commission 11070 Revisions `Aheet A -7 7 of 11 5 A -7 O 4 EXISTING CONCRETE A j BEAM ~ - NEW IMPACT WINDOW SYSTEM C0 IN EXISTING STRUCTURAL WALL OPENING, SEE NOA SCHEDULE ON "i" SHEET .O X 6 V- >' A-7 INDICATES TOP OF SLAB 1. ALL DOOR FRAMES TO RECEIVE TWO COATS OF SEMI -GLOSS PAINT, SEE SPECIFICATIONS. COLOR TO BE SELECTED BY ARCHITECT. 2. EACH DOOR TO RECEIVE RUBBER WALL (W) OR FLOOR (F) BUMPERS AS INDICATED; US 32 FINISH (POLISHED STAINLESS STEEL) 3. ALL EXISTING CYLINDERS TO BE STORED AND RETURNED TO THE OWNER AFTER REPLACEMENT OF DOOR HARDWARE. CO O 4. ALL DOORS AND HARDWARE ARE TO COMPLY WITH THE FLORIDA 0 BUILDING CODE AND THE AMERICANS WITH DISABILITIES ACT. 5. DOORS AND FRAME TO MEET ALL DADE COUNTY REQUIREMENTS. `0 ALL EXTERIOR DOORS TO HAVE CURRENT NOTICE OF 0 ACCEPTANCE AND BE INSTALLED IN A COMPLIANT MANNER. 6. CONTRACTOR TO SUBMIT COMPLETE SHOP DRAWINGS OF ALL GLASS/ ALUMINUM DOORS AND ALL METAL DOORS AND FRAMES. 7. STOREFRONT DOOR TO BE ALUMINUM MEDIUM STYLE STOREFRONT DOOR WITH CLEAR ANODIZED FINISH. 9/16" IMPACT GLAS STOREFRONT SYSTE CLEAR ANODIZED AI FRAME, TYPICAL ALUMINUM STOREFF DOOR FRAME, TYPIC STOREFRONT DOOR FRAME, BEYOND 9/16" IMPACT GLA4 STOREFRONT SYSTEM IN CLEAR ANODIZED ALUMINUM FRAME, TYPICAL 7 Door Head 311 A -7 w AN Q I 7 FORBES AECH70TECTS architecture " land planning retail design - space- r1anninC --- "cons'.ruct,on n;"anaEernent 4 65 ^R ace- dell -ec^n b'vd. suite 100 coral gables, florida 33146 tel :305.446.0849 fax: 305.444.5557 florida registration no. AA -FOOO104 O O O O O O O O 4 O O O O O O O o e e 0 0 O o 0 O O 0 0 O 0 0 0 a a 0 O 0 O O 0 e 0 0 a a 0 e 0 a 0 O 0 O 0 0 0 0 0 0­0 0 . 0 a 0 O q,G• 0 c=, ..• r•` , i John Roberts Forbes AR0009810 OWNERSHIP AND USE OF THE DOCUMENTS: THESE DRAWINGS. SCHEDULES. SPECIFICATIONS AND EXPRESSED IDEAS AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE PROPERTY OF FORBES ARCHITECTS WHETHER THE PROJECT FOR WHICH THEY ARE PREPARED IS EXECUTED OR NOT. THE OWNER AND TENANT SHALL ONLY BE PERMITTED TO RETAIN COPIES OF THESE DRAWINGS. SCHEDULES, SPECIFICATIONS AND EXPRESSED IDEAS FOR INFORMATION AND REFERENCE. THE DRAWINGS,. SCEDIXES. SPECIFICATIONS AND EXPRESSED IDEAS SHALL NOT BE USED BY THE OWNER AND /oR TENANT ON OTHER PROJECTS. FOR ADDITIONS TO THIS PROJECT OR FOR COMPLETION OF THE PROJECT BY OTHERS EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSA TO FORBES ARCHITECTS. COPYRIGHT 2012, JOHN FMS. INC., aba FORBES ARCHITECTS. ALL RIGHTS RESERVED. v/ LM 0 ^- W CN W !� L �I N M O ? M O CL Q J U LL c� M w .E 'd O O O '- I�+ U) LL U m �4 a. Date I e a th v a� Cn co ;ra c es C > r- O Q o = v u- C EcE GT m a o fn° n fn° 0} 3 0 02 -22 -12 Commission 11070 Revisions `Aheet A -7 7 of 11