12-559-012PROVIDE 3/4" PAINTED
STUCCO FINISH AFTER DOOR
FRAME IS REINSTALLED
EXISTING PAINTED
STUCCO FINISH
EXISTING PAINTED
CONCRETE FINISH
EXISTING CONCRETE
LINTEL
FILL HEAD W/ GROUT &
SECURE W/ 2 ANCHORS
TO CONCRETE LINTEL
CONTINUOUS CAULK TO
MATCH WALL COLOR, TYPICAL
HOLLOW METAL FRAME,
WITH PAINT FINISH
DOOR AS SCHEDULED
CONT. SEALANT CAULK
TO MATCH WALL COLOR,
TYPICAL
SLOPE STUCCO 1/4"
1 Door Head 3"
A -7
PROVIDE 3/4" PAINTED
STUCCO FINISH AFTER DOOR
FRAME IS REINSTALLED
DIMENSION PER DOOR SCHEDULE,
CONTINUOUS CAULK TO MATCH
FRAME COLOR, TYPICAL
FILL JAMB WITH GROUT & SECURE
WITH 3 ANCHORS TO CMU
HOLLOW METAL DOOR
FRAME WITH PAINT FINISH
DOOR AS SCHEDULED
CONTINUOUS SEALANT TO
MATCH FRAME COLOR, TYPICAL
STUCCO WITH PAINT FINISH
2 Door Jamb 3"
A -7
Viols]
ADA COMPLIANT
THRESHOLD, PEMKO
2005 -T OR EQUAL
EXISTING SLAB
SET THRESHOLD IN
CONTINUOUS BED OF SEALANT
NO. 10 x 1 1/2" FHWS
PHILLIPS SCREW
9- OF DOOR
� Threshold Detail s°
1
9/16" IMPACT GLASS STOREFRONT
SYSTEM IN CLEAR ANODIZED
ALUMINUM FRAME FASTENED PER
NOA, TYPICAL
3 X" X J" WD P.T. FRAME
BEYOND FASTENED TO
STEEL POST
CONTINOUS SEALANT,
TYPICAL
BOTTOM CONNECTION 8" x 8" x 1/4"
STEEL PLATE WELDED TO VERTICAL
POST. RECESS TO MAKE FLUSH WITH
FLOOR, SEE STRUCTURAL DRAWINGS
BREAK METAL WITH FINISH
TO MATCH MULLION
VERTICAL STEEL POST
4 Jamb and Mullion Detail 3"
A -7
EXISTING CONCRETE LINTEL
EXISTING RIGID INSULATION
EXISTING 5/8" GYPSUM BOARD WITH PAINT
FINISH, PATCH AND MATCH ADJACENT
FINISHES AS REQUIRED
1 X PT WOOD BUCK CONTINUOUS
ATTACHMENTS ACCORDING TO NOA
SPECIFICATIONS
SEALANT CONTINUOUS
NEW IMPACT WINDOW SYSTEM, SEE
NOA SCHEDULE ON "I" SHEET
EXISTING STUCCO WITH PAINT FINISH,
PATCH AND MATCH ADJACENT FINISHES
AS REQUIRED
5 Head Detail 30'
A -7 Jamb Similar
[I.1111:( 61
DOOR
DOOR SIZE
MATERIAL
FINISH
UC
DETAILS
LABEL
DOOR HARDWARE
DOOR NOTES
REMARKS
No.
TYPE
W.
H.
T.
DOOR
CORE
FRAME
DOOR
FRAME
JAMB
HEAD
SILL
SET NO.
LASER
STOP
101
B
3' -0"
6' -8"
1 3/4"
MTL.
-
MTL
PAINT
PAINT
WALL/CEILING - A or B
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
102
A
3' -0"
EXIST
EXIST
EXIST
EXIST
EXIST
PAINT
PAINT
FLOOR - NONE REQ.
EXIST
EXIST
EXIST
EXIST
-
-
103
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME W/ PANIC HARDWARE
104
B
3' -0"
6' -8"
1 3/4"
MTL.
-
MTL
PAINT
PAINT
2/A -7
1/A-7
3/A -7
NO. 1
CLOSER
-
PROVIDE ELECTRIC STRIKE ON DOOR FRAME
105
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
DOOR TO HAVE PANIC HARDWARE
106
NOT USED
107
C
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
NO. 3
CLOSER
-
108
D
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
NO. 3
CLOSER
-
109
C
2 -3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
NO. 3
CLOSER
-
110
B
3' -0"
6' -8"
1 3/4"
MTL.
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
DOOR TO HAVE PANIC HARDWARE
111
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
NO. 1
CLOSER
-
DOOR TO HAVE PANIC HARDWARE
201
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL.
PAINT
PAINT
2/A -7
1/A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
202
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL.
PAINT
PAINT
2/A -7
1 /A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
203
A
3' -0"
EXIST
EXIST
EXIST
EXIST
EXIST
PAINT
PAINT
EXIST
EXIST
EXIST
EXIST
-
-
204
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL.
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
205
B
3' -0"
6` -8"
1 3/4"
EXIST
EXIST
EXIST
PAINT
PAINT
2/A -7
1/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
206
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
207
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
301
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
0
CD
302
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
t3
303
A
3' -0"
EXIST
EXIST
EXIST
EXIST
EXIST
PAINT
PAINT
EXIST
EXIST
EXIST
EXIST
-
-
L
304
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
0
305
B
3' -0"
6' -8"
13/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
306
B
3' -0"
6' -8"
1 3/4"
MTL.
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
307
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
401
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
402
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
403
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
404
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL.
PAINT
PAINT
2/A -7
1/A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
405
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
406
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
13-LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
501
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
502
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
503
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL.
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
504
B
3' -0"
6' -8"
1 3/4"
MTL.
-
MTL.
PAINT
PAINT
2/A -7
1 /A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
505
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL.
PAINT
PAINT
2/A -7
1/A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
506
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
601
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
602
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1 /A -7
3/A -7
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
603
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
604
B
3' -0"
6' -8"
1 3/4"
MTL
-
MTL
PAINT
PAINT
2/A -7
1/A -7
-
B -LABEL
NO. 1
CLOSER
W
NEW 90 MINUTE FIRE RATED DOOR AND FRAME
605
E
3' -0"
7' -0"
1 3/4"
ALUM
GLASS
ALUM
ANOD.
ANOD.
7/A -7
7/A -7
3/A -7
NO. 2
CLOSER
-
TRANSLUCENT GLASS
BOTTOM CONNECTION 8" x 8" x 1/4"
STEEL PLATE WELDED TO VERTICAL
POST. RECESS TO MAKE FLUSH WITH
FLOOR, SEE STRUCTURAL DRAWINGS
BREAK METAL WITH FINISH
TO MATCH MULLION
VERTICAL STEEL POST
4 Jamb and Mullion Detail 3"
A -7
EXISTING CONCRETE LINTEL
EXISTING RIGID INSULATION
EXISTING 5/8" GYPSUM BOARD WITH PAINT
FINISH, PATCH AND MATCH ADJACENT
FINISHES AS REQUIRED
1 X PT WOOD BUCK CONTINUOUS
ATTACHMENTS ACCORDING TO NOA
SPECIFICATIONS
SEALANT CONTINUOUS
NEW IMPACT WINDOW SYSTEM, SEE
NOA SCHEDULE ON "I" SHEET
EXISTING STUCCO WITH PAINT FINISH,
PATCH AND MATCH ADJACENT FINISHES
AS REQUIRED
5 Head Detail 30'
A -7 Jamb Similar
[I.1111:( 61
HARDWARE SET NO. 1
5
LOCKSET: PASSAGE TYPE
C
O
OCCUPANCY
EXITS
HARDWARE SET NO. 2
OTHER SPACES
4
LOCKSET: SUITE ENTRY
=
A
`0
BUSINESS - NEW
D
HARDWARE SET NO. 3
WALL/CEILING - A, B or C
LOCKSET. STOREROOM TYPE
BOTTOM CONNECTION 8" x 8" x 1/4"
STEEL PLATE WELDED TO VERTICAL
POST. RECESS TO MAKE FLUSH WITH
FLOOR, SEE STRUCTURAL DRAWINGS
BREAK METAL WITH FINISH
TO MATCH MULLION
VERTICAL STEEL POST
4 Jamb and Mullion Detail 3"
A -7
EXISTING CONCRETE LINTEL
EXISTING RIGID INSULATION
EXISTING 5/8" GYPSUM BOARD WITH PAINT
FINISH, PATCH AND MATCH ADJACENT
FINISHES AS REQUIRED
1 X PT WOOD BUCK CONTINUOUS
ATTACHMENTS ACCORDING TO NOA
SPECIFICATIONS
SEALANT CONTINUOUS
NEW IMPACT WINDOW SYSTEM, SEE
NOA SCHEDULE ON "I" SHEET
EXISTING STUCCO WITH PAINT FINISH,
PATCH AND MATCH ADJACENT FINISHES
AS REQUIRED
5 Head Detail 30'
A -7 Jamb Similar
[I.1111:( 61
NEW IMPACT WINDOW SYSTEM, SEE
NOA SCHEDULE ON "i" SHEET
SEALANT CONTINUOUS
EXISTING STUCCO ON WINDOW SILL TO BE
REMOVED AND RE- STUCCOED AFTER
INSTALLATION OF NEW WINDOW SYSTEM,
NEW STUCCO TO BE PAINTED AND MATCH
ADJACENT FINISHES AS REQUIRED
ATTACHMENTS ACCORDING TO NOA
SPECIFICATIONS
EXISTING CONCRETE SILL
EXISTING STUCCO WITH PAINT FINISH, PATCH
AND MATCH ADJACENT FINISHES AS REQUIRED
6 Sill Detail 3°
A -7
EQ. EQ.
FLUSH DOOR FLUSH DOOR FIXED METAL
WITH WIRE GLASS LOUVRE
O
Q. VISION PANEL
A
I-
L
O
O
d
T
2'X2' FIXED STOREFRONT
METAL LOUVRE DOOR
2007 NFPA 101
5
7.1.4, 10.2 and SPECIFIC OCCUPANCIES
C
O
OCCUPANCY
EXITS
EXIT ACCESS CORRIDORS
OTHER SPACES
4
EXISTING CONCRETE
A
CU
BUSINESS - NEW
WALL/CEILING - A or B
WALL/CEILING - A or B
WALL/CEILING - A, B or C
'Y) (NFPA
101 38.3.3)
FLOOR - CLASS I or II
FLOOR - CLASS I or II
FLOOR - NONE REQ.
L-
NEW IMPACT WINDOW SYSTEM
C0
IN EXISTING STRUCTURAL
0 5
BUSINESS - EXISTING
WALL/CEILING - A or B
WALL/CEILING - A or B
WALL /CEILING - A, B or C
CD —
(NFPA 101 39.3.3)
FLOOR - NONE REQ.
FLOOR - NONE REQ.
FLOOR - NONE REQ.
X
STORAGE
WALL/CEILING - A or B
WALL/CEILING - A or B
WALL /CEILING - A, B or C
ICU
(NFPA 101 42.3.3)
FLOOR - NONE REQ.
FLOOR - NONE REQ.
(STORAGE AREAS)
FLOOR - NONE REQ.
NEW IMPACT WINDOW SYSTEM, SEE
NOA SCHEDULE ON "i" SHEET
SEALANT CONTINUOUS
EXISTING STUCCO ON WINDOW SILL TO BE
REMOVED AND RE- STUCCOED AFTER
INSTALLATION OF NEW WINDOW SYSTEM,
NEW STUCCO TO BE PAINTED AND MATCH
ADJACENT FINISHES AS REQUIRED
ATTACHMENTS ACCORDING TO NOA
SPECIFICATIONS
EXISTING CONCRETE SILL
EXISTING STUCCO WITH PAINT FINISH, PATCH
AND MATCH ADJACENT FINISHES AS REQUIRED
6 Sill Detail 3°
A -7
EQ. EQ.
FLUSH DOOR FLUSH DOOR FIXED METAL
WITH WIRE GLASS LOUVRE
O
Q. VISION PANEL
A
I-
L
O
O
d
T
2'X2' FIXED STOREFRONT
METAL LOUVRE DOOR
1. ALL DOOR FRAMES TO RECEIVE TWO COATS OF SEMI -GLOSS PAINT, SEE
SPECIFICATIONS. COLOR TO BE SELECTED BY ARCHITECT.
2. EACH DOOR TO RECEIVE RUBBER WALL (W) OR FLOOR (F) BUMPERS AS
INDICATED; US 32 FINISH (POLISHED STAINLESS STEEL)
3. ALL EXISTING CYLINDERS TO BE STORED AND RETURNED TO THE OWNER
AFTER REPLACEMENT OF DOOR HARDWARE.
CO
O 4. ALL DOORS AND HARDWARE ARE TO COMPLY WITH THE FLORIDA
0 BUILDING CODE AND THE AMERICANS WITH DISABILITIES ACT.
5. DOORS AND FRAME TO MEET ALL DADE COUNTY REQUIREMENTS.
`0 ALL EXTERIOR DOORS TO HAVE CURRENT NOTICE OF
0 ACCEPTANCE AND BE INSTALLED IN A COMPLIANT MANNER.
6. CONTRACTOR TO SUBMIT COMPLETE SHOP DRAWINGS OF ALL
GLASS/ ALUMINUM DOORS AND ALL METAL DOORS AND FRAMES.
7. STOREFRONT DOOR TO BE ALUMINUM MEDIUM STYLE
STOREFRONT DOOR WITH CLEAR ANODIZED FINISH.
9/16" IMPACT GLAS
STOREFRONT SYSTE
CLEAR ANODIZED AI
FRAME, TYPICAL
ALUMINUM STOREFF
DOOR FRAME, TYPIC
STOREFRONT DOOR
FRAME, BEYOND
9/16" IMPACT GLA4
STOREFRONT SYSTEM IN
CLEAR ANODIZED
ALUMINUM FRAME, TYPICAL
7 Door Head 311
A -7
w AN
Q
I
7
FORBES
AECH70TECTS
architecture "
land planning
retail design
- space- r1anninC ---
"cons'.ruct,on n;"anaEernent
4 65 ^R ace- dell -ec^n b'vd.
suite 100
coral gables, florida 33146
tel :305.446.0849
fax: 305.444.5557
florida registration
no. AA -FOOO104
O O O O O O O O
4 O O O O O O O
o e e 0 0 O o 0
O O 0 0 O 0 0 0
a a 0 O 0 O O 0
e 0 0 a a 0 e 0
a 0 O 0 O 0 0 0
0 0 00 0 . 0 a 0 O
q,G• 0 c=, ..• r•` , i
John Roberts Forbes
AR0009810
OWNERSHIP AND USE OF THE DOCUMENTS:
THESE DRAWINGS. SCHEDULES. SPECIFICATIONS
AND EXPRESSED IDEAS AS INSTRUMENTS OF
SERVICE ARE AND SHALL REMAIN THE
PROPERTY OF FORBES ARCHITECTS WHETHER
THE PROJECT FOR WHICH THEY ARE PREPARED
IS EXECUTED OR NOT. THE OWNER AND
TENANT SHALL ONLY BE PERMITTED TO RETAIN
COPIES OF THESE DRAWINGS. SCHEDULES,
SPECIFICATIONS AND EXPRESSED IDEAS FOR
INFORMATION AND REFERENCE. THE DRAWINGS,.
SCEDIXES. SPECIFICATIONS AND EXPRESSED
IDEAS SHALL NOT BE USED BY THE OWNER
AND /oR TENANT ON OTHER PROJECTS. FOR
ADDITIONS TO THIS PROJECT OR FOR
COMPLETION OF THE PROJECT BY OTHERS
EXCEPT BY AGREEMENT IN WRITING AND WITH
APPROPRIATE COMPENSA TO FORBES
ARCHITECTS. COPYRIGHT 2012, JOHN
FMS. INC., aba FORBES ARCHITECTS.
ALL RIGHTS RESERVED.
v/
LM
0
^-
W
CN
W !�
L
�I N M O
? M O
CL Q J U
LL c�
M
w .E 'd
O O
O '-
I�+ U) LL
U
m
�4
a.
Date
I e a
th
v
a� Cn
co
;ra c es
C > r- O Q o
= v u-
C
EcE
GT m
a o
fn° n fn°
0}
3
0
02 -22 -12
Commission
11070
Revisions
`Aheet
A -7
7 of 11
5
A -7
O
4
EXISTING CONCRETE
A
j
BEAM
~
-
NEW IMPACT WINDOW SYSTEM
C0
IN EXISTING STRUCTURAL
WALL OPENING, SEE NOA
SCHEDULE ON "i" SHEET
.O
X
6
V-
>'
A-7
INDICATES TOP OF SLAB
1. ALL DOOR FRAMES TO RECEIVE TWO COATS OF SEMI -GLOSS PAINT, SEE
SPECIFICATIONS. COLOR TO BE SELECTED BY ARCHITECT.
2. EACH DOOR TO RECEIVE RUBBER WALL (W) OR FLOOR (F) BUMPERS AS
INDICATED; US 32 FINISH (POLISHED STAINLESS STEEL)
3. ALL EXISTING CYLINDERS TO BE STORED AND RETURNED TO THE OWNER
AFTER REPLACEMENT OF DOOR HARDWARE.
CO
O 4. ALL DOORS AND HARDWARE ARE TO COMPLY WITH THE FLORIDA
0 BUILDING CODE AND THE AMERICANS WITH DISABILITIES ACT.
5. DOORS AND FRAME TO MEET ALL DADE COUNTY REQUIREMENTS.
`0 ALL EXTERIOR DOORS TO HAVE CURRENT NOTICE OF
0 ACCEPTANCE AND BE INSTALLED IN A COMPLIANT MANNER.
6. CONTRACTOR TO SUBMIT COMPLETE SHOP DRAWINGS OF ALL
GLASS/ ALUMINUM DOORS AND ALL METAL DOORS AND FRAMES.
7. STOREFRONT DOOR TO BE ALUMINUM MEDIUM STYLE
STOREFRONT DOOR WITH CLEAR ANODIZED FINISH.
9/16" IMPACT GLAS
STOREFRONT SYSTE
CLEAR ANODIZED AI
FRAME, TYPICAL
ALUMINUM STOREFF
DOOR FRAME, TYPIC
STOREFRONT DOOR
FRAME, BEYOND
9/16" IMPACT GLA4
STOREFRONT SYSTEM IN
CLEAR ANODIZED
ALUMINUM FRAME, TYPICAL
7 Door Head 311
A -7
w AN
Q
I
7
FORBES
AECH70TECTS
architecture "
land planning
retail design
- space- r1anninC ---
"cons'.ruct,on n;"anaEernent
4 65 ^R ace- dell -ec^n b'vd.
suite 100
coral gables, florida 33146
tel :305.446.0849
fax: 305.444.5557
florida registration
no. AA -FOOO104
O O O O O O O O
4 O O O O O O O
o e e 0 0 O o 0
O O 0 0 O 0 0 0
a a 0 O 0 O O 0
e 0 0 a a 0 e 0
a 0 O 0 O 0 0 0
0 0 00 0 . 0 a 0 O
q,G• 0 c=, ..• r•` , i
John Roberts Forbes
AR0009810
OWNERSHIP AND USE OF THE DOCUMENTS:
THESE DRAWINGS. SCHEDULES. SPECIFICATIONS
AND EXPRESSED IDEAS AS INSTRUMENTS OF
SERVICE ARE AND SHALL REMAIN THE
PROPERTY OF FORBES ARCHITECTS WHETHER
THE PROJECT FOR WHICH THEY ARE PREPARED
IS EXECUTED OR NOT. THE OWNER AND
TENANT SHALL ONLY BE PERMITTED TO RETAIN
COPIES OF THESE DRAWINGS. SCHEDULES,
SPECIFICATIONS AND EXPRESSED IDEAS FOR
INFORMATION AND REFERENCE. THE DRAWINGS,.
SCEDIXES. SPECIFICATIONS AND EXPRESSED
IDEAS SHALL NOT BE USED BY THE OWNER
AND /oR TENANT ON OTHER PROJECTS. FOR
ADDITIONS TO THIS PROJECT OR FOR
COMPLETION OF THE PROJECT BY OTHERS
EXCEPT BY AGREEMENT IN WRITING AND WITH
APPROPRIATE COMPENSA TO FORBES
ARCHITECTS. COPYRIGHT 2012, JOHN
FMS. INC., aba FORBES ARCHITECTS.
ALL RIGHTS RESERVED.
v/
LM
0
^-
W
CN
W !�
L
�I N M O
? M O
CL Q J U
LL c�
M
w .E 'd
O O
O '-
I�+ U) LL
U
m
�4
a.
Date
I e a
th
v
a� Cn
co
;ra c es
C > r- O Q o
= v u-
C
EcE
GT m
a o
fn° n fn°
0}
3
0
02 -22 -12
Commission
11070
Revisions
`Aheet
A -7
7 of 11