12-559-004.Q
GV
'I0
EXISTING METAL GRILLE TO BE PRESSURE
CLEANED, DRIED AND PAINTED WITH
ELECTROSTATIC ENAMEL PER MANUFACTURES
RECOMMENDATION. SEE SPECIFICATIONS.
COLOR SELECTION BY OWNER, TYPICAL
EXISTING CANVAS CANOPY
AND FRAME TO REMAIN
COLUMNS TO RECEIVE
NEW PAINT FINISH
EXISTING ELEVATOR
TO REMAIN AS IS
EXISTING LEVEL NUMBER TO BE RE- STENCILED
AFTER PAINTING OF WALL TO MATCH EXISTING
COLOR AND SIZE, SEE DETAILS 2/A -2 AND 3/A -2
ALL STAIR VESTIBULE WALLS TO RECEIVE
NEW PAINT FINISH. COLOR TO MATCH
EXISTING. SEE SPECIFICATIONS, TYPICAL
I-`
EXISTING DRINKING
FOUNTAIN TO REMAIN I
� I
COVERED WALKWAY LEADING
TO THE CLARK EDUCATION Exist
CENTER SHALL BE ENTIRELY Yj . . . . . . .
PAINTED INSIDE AND OUT Stor ° ` i .
.
EXisting.
101 102 Fire Alarm
I . . . . ,
Stair _ . . . . . . . . . . . . . Room. . . . . . . . . .
Vest
_ 103 _ ___ ............ ....._.yrc: PROVIDE ALL . . . . . . . . . .
S
NEW tair— 3 TH S ARE IA NG . . . . . . . . Interior Area . . . . . . .
No 1 U NIC .
EXISTING HANDRAILS AND GUARDRAILS TO BE
REMOVED AND TO BE REPLACED WITH NEW t ` ` ` ' ' ' ' ' . ' . ` ' ` ' ` ' ' ' ' ° ° • • ° •
1 -1/2.0 METAL HANDRAIL WITH PAINT FINISH. . . ' • ' ' ' ` ` ' ° ` • • • • • • •
REMOVE OLD ANCHORS AND FILL, PATCH,....._._._____ _ ._......
AND OTHERWISE REPAIR ANCHOR SYSTEM .
PRIOR TO INSTALLATION OF NEW HANDRAILS. --
SEE DETAILS 1/A -10 AND 2/A -10, TYPICAL t
OF SIGN AND PARKING EXISTING ISLAND AND PARKING I PAINT EXISTING . . ' . • . . . . . . . . . . . . . . . . . ' '
SPACE, TYPICAL EACH ACCESSIBLE SPACE. EQUIPMENT TO REMAIN AS IS CONCRETE CURBS
SAFETY YELLOW
PORTION OF EXISTING CURB
TO BE REMOVED AND U. NEW 3` -0" WIDE BY 5' -0" LONG
PATCHED TO MATCH EXISTING �0 5
CONCRETE SURFACE SURFACE MOUNTED DETECTABLE
5' -0" WARNING TRUNCATED DOMES BY
I
- ARMOR TILE, FEDERAL YELLOW,
�'�-- SURFACE MOUNT HANDICAP SIGN, INDICATES NEW 5'-0" WIDE o OR APPROVED EQUAL, TYPICAL
SEE DETAIL 3/A -1 PAINTED STRIPES AND ACCESSIBLE in
DRIVE CROSSING, TYPICAL EXTERIOR WALLS AND COLUMNS TO
RECEIVE NEW PAINT FINISH. COLOR TO
:° MATCH EXISTING. SEE SPECIFICATIONS
EXISTING CONCRETE WALK ONE NEW ACCESSIBLE PARKING
SPACE 12' -0" X 18' -0 ", SEE
ACCESSIBLE PARKING SPACE
DETAIL 2/A -1, TYPICAL 1 0 n
5 " -0"
Typical Accessible
2 Parking Space Plan 1/411
A -1
(LAYOUT MAY BE REVERSED)
•
BLACK ON WHITE
fi
TT ARAY ZONE
AND FINE UP TO i
•o
9
Typical Accessible Parking
3 Si na a Detail N.T.S.
A -1
— EDGE OF WALK
— NEW PRECAST CONCRETE 2 NEW STANDARD PARKING —
WHEEL STOP 6' LONG SPACES ® 8' -6" EACH
4" WIDE WHITE PAINT AS
PER MIAMI -DADE COUNTY
STANDARD
4" WIDE LIGHT BLUE PAINT
AS PER MIAMI -DADE
COUNTY STANDARD
4" WIDE GREEN PAINT AS
4" 12" 4" PER MIAMI -DADE COUNTY
STANDARD
INTERNATIONAL SYMBOL OF
ACCESSIBILITY AS PER
MIAMI -DADE COUNTY
STANDARDS PAINTED BLUE.
4" WIDE LIGHT BLUE PAINTED
ACCESS AISLE
EXISTING CONCRETE
CURB TO REMAIN
EDGE OF BLUE STRIPE, TYPICAL
EXISTING METAL GRILLE TO BE —
PRESSURE CLEANED, DRIED AND
PAINTED WITH ELECTROSTATIC
ENAMEL PER MANUFACTURES
RECOMMENDATION. SEE
SPECIFICATIONS. COLOR SELECTION
BY OWNER, TYPICAL
INDICATES NEW
STRIPING THIS AREA
EXISTING LEVEL NUMBER TO BE
RE- STENCILED AFTER PAINTING OF
WALL TO MATCH EXISTING COLOR
AND SIZE, SEE DETAIL 4/A -2
H
EXISTING HANDRAILS AND GUARDRAILS TO BE
REMOVED AND TO BE REPLACED WITH NEW
1 -1/2 "0 METAL HANDRAIL WITH PAINT FINISH.
REMOVE OLD ANCHORS AND FILL, PATCH,
AND OTHERWISE REPAIR ANCHOR SYSTEM
PRIOR TO INSTALLATION OF NEW HANDRAILS.
SEE DETAILS 1/A -10 AND 2/A -10, TYPICAL
PROVIDE NEW WIND- DRIVEN RAIN
RESISTANT STATIONARY LOUVER EME520MD
BY RUSKIN IN EXISTING OPENING. PAINT TO
MATCH EXISTING METAL GRILLE ACCENT
COLOR, SEE DETAIL 7/A -9
A -9
€ 2
E
I
I
it
EXISTING BOILER ROOM
EQUIPMENT AND PIPES TO BE
REMOVED AND CAPPED
EXISTING HANDRAILS AND GUARDRAILS TO BE
REMOVED AND TO BE REPLACED WITH NEW
1 -1/2.0 METAL HANDRAIL WITH PAINT FINISH.
REMOVE OLD ANCHORS AND FILL, PATCH,
AND OTHERWISE REPAIR ANCHOR SYSTEM
PRIOR TO INSTALLATION OF NEW HANDRAILS.
SEE DETAILS 1/A -10 AND 2/A -10, TYPICAL
EXISTING LEVEL NUMBER TO BE
RE- STENCILED AFTER PAINTING OF
WALL TO MATCH EXISTING COLOR
AND SIZE, SEE DETAIL 5/A -2
EXISTING PIPE INSULATION
TO BE REPAIRED, SEE
MECHANICAL DRAWINGS
Add Altemate Nol:
GC TO PROVIDE A UNIT PRICE FOR
THE REPLACEMENT OF THE EXISTING
EXPANSION JOINT MATERIAL WITH
THE WABO UREFLEX POLYURETHANE
PREMOLD EXPANSION SYSTEM BY
BASF OR APPROVED EQUAL. SEE
SPECIFICATIONS, TYPICAL
I
EXISTINO EXHAUST FAN D
DAMPER TO BE OEMOVED WALL 10
OPENING IN AREAS OF D MOLI110
TO BE PATCHED AND PAINTED TO
MATCH EXISTING. ELECTRICAL
ROOM TO BE AIR CONDITIONED.
SEE MECHANICAL DRAWINGS
11:= plumpow
4�
108
r2' 0" 109
I i
z PROVIDE ALL NEW
ADA STRIPING O
43
oeoeINDICATES NEW
STRIPING THIS AREA
04-11
"._
Exist EXISTING DOOR AND FRAME '�
TO BE REMOVED. EXISTING'
EleY 3' -0" X 6' -8" DOOR
M @Ch OPENING TO BE IN- FILLED yi • 1 $
WITH CONCRETE MORTAR *'` •'•.+�. . "
3 A -9 UNIT. NEW FINISH TO i A`
Existing MATCH AND BE FLUSH
Electrical WITH EXISTING EXTERIOR John Roberts' Forbes
AND INTERIOR WALL FINISH.
Room AR0009810
OWNERSHIP AND USE OF THE DOCUMENTS:
THESE DRAWINGS. SCHEDULES. SPECIFICATIONS
Existing AND EXPRESSED IDEAS AS INSTRUMENTS OF
SERVICE ARE AND SHALL REMAIN THE
PROPERTY OF FORGES ARCHITECTS WHETHER
Generator PROJECT F WHICH THEY ARE PREPARED
Room TENANT SHALL ONLY BE PERMITTED To RETAIN
EXISTING CONCRETE PARKING
GARAGE STRUCTURE TO
REMAIN AS IS UNLESS
OTHERWISE NOTED
EXISTING PARKING CONFIGURATION AND
STRIPING TO REMAIN AS IS UNLESS
OTHERWISE NOTED, TYPICAL
EXISTING CONCRETE WHEELSTOPS
TO REMAIN AS IS UNLESS
OTHERWISE NOTED, TYPICAL
EXISTING METAL GRILLE TO BE
PRESSURE CLEANED, DRIED AND
PAINTED WITH ELECTROSTATIC
ENAMEL PER MANUFACTURES
RECOMMENDATION. SEE
Legend
FORBES
iRt TECTS
REMOVE EXISTING DOOR AND
REPLACE WITH NEW DOOR, SEE
architecture
--- ••• -•.•
EXISTING CONCRETE WHEEL STOP
land planning
EXISTING CONCRETE WHEEL STOP TO BE
retail design
c
NEW 6' LONG PRECAST CONCRETE WHEEL
sFrre- nIannIi:I,-
EXISTING FIRE EXTINGUISHER TO REMAIN,
",
constfCctloi-o maGagen'ient
AFTER PAINTING IS COMPLETE
-4FFF ),)n -.e �ec 'eor, b4 -e.-
suite 700
coral gables, florida 33146
tel: 305.446.0649
fax: 305.444.5557
florida registration
no. AA - F000104
O O a O O O O O
O O O a a O O O
o e e o o a a a
a e a O O O O O
o e a o e a a a
`
Boiler
Room
a e o e e a a o
Oa O 4 O
O O O a a a O O
*U
Stair
No 2
Exist EXISTING DOOR AND FRAME '�
TO BE REMOVED. EXISTING'
EleY 3' -0" X 6' -8" DOOR
M @Ch OPENING TO BE IN- FILLED yi • 1 $
WITH CONCRETE MORTAR *'` •'•.+�. . "
3 A -9 UNIT. NEW FINISH TO i A`
Existing MATCH AND BE FLUSH
Electrical WITH EXISTING EXTERIOR John Roberts' Forbes
AND INTERIOR WALL FINISH.
Room AR0009810
OWNERSHIP AND USE OF THE DOCUMENTS:
THESE DRAWINGS. SCHEDULES. SPECIFICATIONS
Existing AND EXPRESSED IDEAS AS INSTRUMENTS OF
SERVICE ARE AND SHALL REMAIN THE
PROPERTY OF FORGES ARCHITECTS WHETHER
Generator PROJECT F WHICH THEY ARE PREPARED
Room TENANT SHALL ONLY BE PERMITTED To RETAIN
EXISTING CONCRETE PARKING
GARAGE STRUCTURE TO
REMAIN AS IS UNLESS
OTHERWISE NOTED
EXISTING PARKING CONFIGURATION AND
STRIPING TO REMAIN AS IS UNLESS
OTHERWISE NOTED, TYPICAL
EXISTING CONCRETE WHEELSTOPS
TO REMAIN AS IS UNLESS
OTHERWISE NOTED, TYPICAL
EXISTING METAL GRILLE TO BE
PRESSURE CLEANED, DRIED AND
PAINTED WITH ELECTROSTATIC
ENAMEL PER MANUFACTURES
RECOMMENDATION. SEE
Legend
SELECTIONRBY OWNER,RTYPICAL
EXISTING DOOR TO REMAIN AS IS
REMOVE EXISTING DOOR AND
REPLACE WITH NEW DOOR, SEE
DOOR SCHEDULE
--- ••• -•.•
EXISTING CONCRETE WHEEL STOP
TO BE PRESSURE CLEANED
EXISTING CONCRETE WHEEL STOP TO BE
PRESSURE CLEANED AND EPDXIED INTO PLACE
c
NEW 6' LONG PRECAST CONCRETE WHEEL
STOP TO BE EPDXIED INTO PLACE
EXISTING FIRE EXTINGUISHER TO REMAIN,
REMOVE FOR PAINTING AND REINSTALL
AFTER PAINTING IS COMPLETE
Level 1
Floor Plan
ntY
NOTES:
• ALL AREAS OF CONCRETE SPALLING THROUGHOUT
ENTIRE BUILDING TO BE REPAIRED.
• ALL AREAS OF BUILDING WHICH ARE CURRENTLY
PAINTED ARE TO BE REPAINTED IN ACCORDANCE WITH
MANUFACTURERS RECOMMENDATIONS INCLUDING
SURFACE PREPARATION FOR THE VARIOUS SUBSTRATES.
COPIES OF THESE DRAWIN (S, SCHEDULES.
SPECIFICATIONS AND EXPRESSED IDEAS FOR
INFORMATION AND REFERENT THE DRAWINGS,
SCHEDULES. SPECIFICATIONS AND EXPRESSED
IDEAS SHALL NOT BE USED BY THE OWNER
AND /OR TENANT ON OTHER PROJECTS, FOR
ADDITIONS TO THIIS PROJECT OR FOR
COMPLETION OF THE PRO ECT BY OTHERS
EXCEPT BY AGREEMENT IN WRITING AND WITH
APPROPRIATE COMPENSATION TO FORBES
ARCMTECTS. COPYRIGHT ® 2012, JOHN
FORGES, INC.. dba FORBES ARCHITECTS,
ALL RIGHTS RESERVED.
w�
W
■
W
L
V
■.� O
L
� M
> co 0
a Q J O
LL'
CD
- CO
CU
0
� O)
� O
O p
co 11- U) LL
m
•O
n.
I / 1 I
to
It
m CV)
ca
C to
C > c
O Q o
=„u
C
E C14
E
o
(0 r`t- U)
m`
3
0
Date
02 -22 -12
Commission
91070
Revisions
-Sheet
•
n A-1
1 of 11