FLOOR P L AN NOTES
1. FIRE RESISTANCE - MAINTAIN INTEGRITY OF EXISTING FIRE ui
AND/OR SMOKE PARTIT1(_,NS T14kCILIG14OUT, UNLESS NOTED
OTHERWISE. MAINTAII`," INTEGFiTY GF `A0_1 LXIS"ING IZIREPROOFING,
FIRESTOPPING, COZ - UHN SNCLO-_UPES,_'ZTC. TD_ ENSAE FIRE
RESISTANCE MEETS -OR _EXCEEDS_ THAT ORIGINALLY REQUIRED OR
SPECIFIED. PATCH ALL AREAS DAMAGED OR REMOVED DUE TO
NEW CONSTRUCTION TO MATCH THAT OF THE EXISTING OR AS
REQUIRED FOR
2. FIRE EXTINGUISF CfR -- ALL EXISTING EXTINGUI3HER3 SHALL BE C>
CLEANED AND F7zCER7IFIED:MQR-T6.PFLOCAT'Cr.- c
3. EXISTING SYSTEMS - ALL EXISTING SYSTEMS SUCH AS ALARMS, c
ELECTRICITY, WATER, SPRINKLERS, ETC. SHALL REMAIN ACTIVE AT
ALL TIMES DURING DEMOLITION & CONSTRUCTION. ANY
EXCEPTION TO THIS SHALL BE COORDINATED WITH THE OWNER
AND ARCHITECT. uj
4. FINISHES - ALL EXISTING FINISHES SHALL REMAIN, UNLESS
SCHEDULED FOR NEW. CONTINUE EXISTING FINISHES TO REMAIN
INTO NEW EXTENDED AREAS THAT ARE ADJACENT. PATCH &
REPAIR EXISTING TO MATCH NEW. PREPARE SUBSTRATES TO
RECEIVE NEW FINISHES WHERE SCHEDULED. FINISH ALL
PATCHED OR EXTENDED WALLS TO NEAREST CHANGE OF
DIRECTION, WALL TERMINATION, OR INTERSECTION. cu
5. CONFLICTS - ANY CONFLICT FOUND WITH EXISTING CONDITIONS c
AND REQUIREMENTS FOR NEW CONSTRUCTION SHALL BE L
IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT. IF
THE CONFLICT AFFECTS THE PROGRESS OF THE WORK, VERIFY
WITH ARCHITECT SOLUTION NECESSARY PRIOR TO PROCEEDING
WITH THAT PORTION OF THE WORK AND IN A TIMELY FASHION SO
AS NOT TO DELAY THE WORK. COORDINATE ALL TRADES TO
ASCERTAIN NO FURTHER WORK WILL BE IMPACTED BY THE
CONFLICT, OR ITS SOLUTION.
6. FLOORS - CONTRACTOR SHALL FIELD VERIFY LEVELNESS OF
EXISTING FLOOR SLABS AFTER COMPLETION OF DEMOLITION
WORK AND BRING TO THE ARCHITECT'S ATTENTION ANY DEVIATION
FROM SPECIFIED TOLERANCES. ANY CORRECTIVE WORK SHALL BE
ACCOMPLISHED PRIOR TO NEW CONSTRUCTION. ("NOTE TO c
c
PROJECT ARCHITECT -NOTE ON DRAWINGS ANY AREAS/QUANTITY
OF KNOWN CORRECTIVE WORK REQUIRED") c' c-"
a
7. SEALED OPENINGS - WHERE OPENINGS ARE CREATED IN 6
E
EXISTING CONSTRUCTION SCHEDULED TO REMAIN (SUCH AS 'coL c- 8
its r- us ,
REMOVAL OF DOORS OR WINDOWS IN EXISTING WALLS TO REMAIN), " 00 o
(m "- L
m c6 (
FURNISH AND INSTALL NEW CONSTRUCTION OF TYPE AND g c6 cn (9 2)N E
THICKNESS TO MATCH THE EXISTING WALL THICKNESS AND RATING, -2 M 04 c') r 0 - =3 C; ca
'2 .0
0 L03; 'IT 0 12
IF ANY. FINISH SUCH SEALED OPENINGS TO MATCH THE EXISTING V c 0 0 (D �; 0 ca
UNLESS NEW FINISHES ARE SCHEDULED FOR THOSE SURFACES. 0 -0 '6 m 0 0;
go. CL
ul r- r
E
8. EXISTING CONSTRUCTION - ALL EXISTING SURFACES TO REMAIN -6 .5 - = ..; m L
WITHIN CONSTRUCTION LIMITS SHALL BE PATCHED AND REPAIRED M) o_
AT AREAS WHERE DEMOLITION WORK HAS OCCURRED TO UPGRADE
TO A CONDITION THAT MATCHES THE EXISTING ADJACENT
CONSTRUCTION. EXISTING WALLS THAT CONTAIN PLUMBING,
ELECTRICAL OR OTHER SERVICES REQUIRING MODIFICATION SHALL
BE CUT BACK TO THE NEAREST STUD TO ALLOW REQUIRED WORK.
AFTER COMPLETION, RECONSTRUCT TO A CONDITION THAT MATCHES
NEW CONSTRUCTION, FLUSH WITH ADJACENT SURFACES. EXISTING
FLOORS WHERE CONSTRUCTION HAS BEEN REMOVED SHALL BE
PATCHED AND LEVELED TO MATCH THE EXISTING.
FLOOR PLAN KEY NOTES
1. PROVIDE NEW WALL RATING AS INDICATED. ENSURE NEW WALLS
HAVE APPROPRIATE ABOVE-CELING LABELS.
2. PROVIDE RAISED CURB FOR LOCKERS. PREPARE CURB TO ACCEPT
SCHEDULED BASE.
3. REFER TO A13.1 FOR FRAMING INFORMATION AT FIRE
EXTINGUISHER LOCATIONS. 0
4. ROOMS WITH STC RATINGS SHALL HAVE WALLS EXTEND TO
UNDERSIDE OF DECK ABOVE.
5. FLOAT FLOORS IN SHOWER ROOMS TO SLOPE TOWARDS DRAIN.
REFER TO DETAILS ON A 16.1 FOR ADDITIONAL INFORMATION. z
lw*.
6. PROVIDE 6" HIGH INTEGRAL BASE WITH METAL CAP IN OPERATING j
ROOM.
PARTITION LEGEND oc
FOUR HOUR FIRE f SMOKE uj
FOUR HOUR FIRE
THREE HOUR FIRE f SMOKE
THREE HOUR FIRE
TWO HOUR FIRE f SMOKE Q 0
TWO HOUR FIRE a:
ONE HOUR FIRE SMOKE 0
— - — - — - ONE HOUR FIRE j
SMOKE RESISTANT TO DECK LL
.......... • • ........ SMOKE RESISTANT TO 4" ABOVE CEILING co
NON-RATED PARTITION
SIC 45 — SOUND RETARDANT PARTITION J
(NUMBER INDICATES STC RATING) <
SHAFT WALL ASSEMBLY 0
—2 MM LEAD LINED PARTITION (LEAD co
THICKNESS INDICATED IN MM.)
f CO
= CONCRETE WALL ASSEMBLY 0
CMU WALL ASSEMBLY =
............ WITH BRICK VENEER
NEW WALL ASSEMBLY j
EXISTING WALL ASSEMBLY <
SYMBOL LEGEND
AREA LIMITS LINE
KEYPLAN
N
Comm. No:
11087.00
Date:
01/18/12
I
Drawn:
Revised:
COORDINATION
02/06/12
AOwner Chonges&Coord
404/06/12
AASI # 2
810/03/12
THE
3rd Floor Level
NEW CONSTRUCTION PLAN
1/4"=1'-O" 201 1n
0 4' 8. 24' A5.3
PRINTED 24X36 NOT TO SCALE