12-509R-009
A _ w /"N, w.. ^ - ... .1.. A I%_ AIR HANDLING UNIT SCHEDULE MAX. WTR. PRESS. DROP = 5 FT. MAX. FACE VELOCITY = 650 FT /MIN. MAX. A.P. DROP = .5' W.C. TRANSITION DUCT TO ACCOMODATE UNIT RIEQ NOTE: 1. UNIT SHIPPED IN SECTIONS. 1 COIL SIZE I i. VARIABLE FREQUENCY DRIVE tVFD) TABLE 2. MAGNEHELIC DIFFERENTIAL PRESSURE GAUGES (EACH FILTER BANK) 2. UNIT ASSEMBLY IN FIELD SHALL BE SUPERVISED BY A FACTORY SERVICE REPRESENTATIVE. 2. ES: HVAC 3. 8' BASE RAIL ��E-- 3. ALL AIR DEVICES INSTALLED IN INACCESSIBLE AND /OR DRYWALL CEILINGS SHALL BE TIC PRESSURE INCLUDES ADDITIONAL FILTER LOSS (DIRTY CONDITION) OF 1.0' FOR RISE IN DUCTWORK 4• ALL AIR DEVICES INSTALLED IN ACCESSIBLE AND /OR LAY -IN CEILINGS SHALL HAVE A E RETURN OR EXHAUST D• _ E LGENERA AINING FINAL FILTERS OR DS' FOR UNITS CONTAINING PRE-FILTERS ON.Y. ': 1 .`1 1. .. �. 1.., .,.. CONDENSER WATER RETURN MANUAL VOLUME DAMPER INSTALLED IN THE BRANCH TAKE -OFF. 2/12 © ♦5:: O r' 1 'Tw � ", ',:1 1,, r1 Y 1 .� HWS HOT WATER SUPPLY r , 11 i r, ;�: m � 1 r• a•. 1 :•� 1 , .., , PRESSURE DROP FOR ALL AIR DEVICES SHALL NOT EXCEED 0.10 IN. W.G. FAN 2/12 FAN MOTOR OUTSIDE AIR ALL AIR DEVICES SHALL BE WHITE UNLESS OTHERWISE NOTED. COOLING COIL rl '.1 • L'. :• FILTER MERV OPERATING ROUND ADAPTER 7. AREA SERVED TYPE LOCATION OF AHU MANUFACTURER MODEL NO. WEIGHT REMARKS 8. ALL AIR DEVICES SHALL BE ALUMINUM CONSTRUCTION UNLESS OTHERWISE FAN SIZE ESP TSP H•P. ELECTRIC CFM MAX. F.V. E.A.T 'F L.A.T 'F TOTAL SENSIBLE GPM EWT /LWT •F MIN. ROWS & MAX. A.P.D. MAX. W.P.D. PRE FINAL Il: 1 �® E 1 �• � CFM RPM 111 1': ' ':r ',: ® ©® S D DUCT SMOKE DETECTOR F�,. �;... �1�.� ► a ',11 !'�::. Y C; Il. 1 ® ®�� 8x6 / 6'0 ©� 2 -3 -6 LBS. O ©O 4 W � VARIABLE FREQUENCY DRIVE NICU HORIZONTAL 3RD FLOOR TRANE MD HDT 25 101350 1800 207 AF 4.0 6.5 20 480/3/60 2725 500 76.0/65.8 51.0/50.9 440.0 275.6 56 44/59 6 / 12 1.0 10.0 MERV -8 - 2900 HVAC GENERAL NOTES 1. HVAC DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND REPRESENT EXISTING CONDITIONS BASED ON DRAWINGS AND SITE OBSERVATIONS. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL ACTUAL CONDITIONS INCLUDING, DUCTWORK AND PIPING LOCATIONS AND SIZES. 2. DUE TO DRAWINGS BEING DIAGRAMMATICAL IN NATURE RISERS AND DROPS ARE NOT SHOWN - CONTRACTOR SHALL INCLUDE THESE IN THE BID - WHERE POSSIBLE ALL RISERS AND DROPS SHALL BE CONSTRUCTED USING 45 DEGREE OR LONG RADIUS ELBOWS. 3. PROVIDE AND INSTALL NECESSARY DUCTWORK TRANSITIONS AND PIPING INCREASERS /REDUCERS AS REQUIRED FOR EQUIPMENT CONNECTIONS. CONSULT MANUFACTURER'S DATA FOR ACTUAL DUCTWORK AND PIPING CONNECTIONS SIZES, INCLUDING, BUT NOT LIMITED TO THOSE SHOWN. 4. PROVIDE MANUAL VOLUME DAMPERS AT ALL LOW PRESSURE BRANCH DUCTS TO INDIVIDUAL DIFFUSERS AND GRILLES AND TO ALL LOW PRESSURE BRANCH DUCTS TO REHEAT COILS. PROVIDE DAMPERS AS CLOSE AS POSSIBLE TO MAIN IN BRANCH CONNECTION. SEE DIFFUSER AND GRILLE SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL INFORMATION, 5. SCHEDULE NEW CONSTRUCTION WORK WITH THE OWNER WELL IN ADVANCE. 6. ALL FINISHES AND SURFACES TO REMAIN WHICH ARE DAMAGED DURING CONSTRUCTION WORK SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER AT NO ADDITIONAL COST TO THE OWNER. 7. DO NOT BLOCK TUBE PULL OR SERVICE SPACE ON EQUIPMENT WITH PIPING, DUCTWORK, ETC.. (FLANGED OR REMOVABLE SECTIONS MAY BE USED IN SOME INSTANCES WHERE TIGHT CLEARANCES EXISTS). 8. NO PIPING, DUCTWORK, OR CONDUIT SHALL BE INSTALLED UNTIL IT IS COORDINATED WITH ALL OTHER TRADES AFFECTED. PROVIDE ALL OFFSETS REQUIRED TO AVOID INTERFERENCE WITH OTHER TRADES; EXISTING CONDITIONS AND WITH THE STRUCTURE, INCLUDING, BUT NOT LIMITED TO, THOSE SHOWN. 9. IF NO SIZE IS SHOWN FOR DUCT SERVING DIFFUSER OR GRILLES, USE SIZE SHOWN ON DIFFUSER AND GRILLE SCHEDULE. 10. DUCTWORK ROUTED PARALLEL TO A WALL, RATED OR CORRIDOR SHALL BE INSTALLED WITH MINIMUM 6' CLEARANCE TO ALLOW FOR INSPECTION OF WALL PENETRATIONS. CONTRACTOR SHALL PROVIDE 12' CLEARANCE WHERE POSSIBLE, COORDINATE. 11. REFER TO DETAIL SHEETS AND SPECIFICATIONS FOR ADDITIONAL INSTALLATION REQUIREMENTS. 12. CONTRACTOR SHALL SUBMIT A COMPLETE LIST OF EQUIPMENT AND ITEMS TO BE REMOVED TO THE OWNER. ALL ITEMS THAT THE OWNER WISHES TO RETAIN SHALL BE TURNED OVER TO OWNER AND THE REMAINDER SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A PROPER MANNER BY CONTRACTOR. 13. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PERFORM ALL WORK NECESSARY TO PREPARE THE STRUCTURE FOR THE INSTALLATION AND /OR DEMOLITION WORK OF THE MECHANICAL SYSTEMS, ALL HOLES, OPENINGS AND ANY DAMAGED MATERIALS OR SURFACES SHALL BE REPAIRED AND FINISHED TO MATCH EXISTING. 14. ALL DEMOLITION WORK SHALL COMPLY WITH NFPA 241 AND THE REQUIREMENTS OF THE OWNER. 15. PROVIDE TEMPORARY FILTERS ON ALL RETURN AIR GRILLES AND TRANSFER OPENINGS IN THE WORK AREA. 16. EXISTING SYSTEMS SHOWN ON THE DRAWINGS ARE BASED ON AVAILABLE RECORD DRAWINGS. THIS INFORMATION IS ONLY PARTIALLY VERIFIED. THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY AND INVESTIGATE ALL CONDITIONS THAT AFFECTS THE WORK PRIOR TO SUBMITTING THE BID. 17. INSTALL AHU CONTROL PANELS TO PROVIDE FOR 3' -0' MIN. CLEARANCE IN FRONT OF PANEL. 18. UNLESS OTHERWISE NOTED ON PLANS, LOW RETURN AIR GRILLES AND LOW EXHAUST GRILLES SHALL BE 6' TO 8' AFF TO BOTTOM OF GRILLE. 19. ALL DIFFUSERS IN SAME SPACE SHALL HAVE THE SAME FULL FACE SIZE USING LARGEST SIZE REQUIRED FROM DIFFUSER AND GRILLE SCHEDULE. 20. PROVIDE CLEAR ACCESS TO FIRE DAMPERS, SMOKE DAMPERS, AND VALVES. 21. PROVIDE MANUFACTURERS CERTIFIED DATA (NOA) OR CALCULATIONS ON ALL EXTERIOR MOUNTED EQUIPMENT DURING SUBMITTAL PHASE, WHICH INDICATES THAT THE EQUIPMENT CAN WITHSTAND A WIND LOAD REQUIRED BY THE FSBC. 22. ALL DUCTWORK AND PIPING MATERIALS SHALL BE PROTECTED WHILE BEING SHIPPED TO THE SITE, STORED ON SITE AND AS INSTALLATION PROGRESSES. DUCTWORK AND PIPING STORED ON SITE PRIOR TO INSTALLATION SHALL BE OFF THE FLOOR. PIPING SHALL BE END CAPPED, COVER ALL DIFFUSERS AND GRILLES AFTER INSTALLATION PRIOR TO EQUIPMENT START UP AND TEST AND BALANCE. (D 0 0 MAX. WTR. PRESS. DROP = 5 FT. MAX. FACE VELOCITY = 650 FT /MIN. MAX. A.P. DROP = .5' W.C. TRANSITION DUCT TO ACCOMODATE AIR DEVICE SCHEDULE 1 COIL SIZE I 1. AIR DEVICE SIZES & SCHEDULED AIRFLOW ARE BY THIS SCHEDULE UNLESS OTHERWISE NOTED ON HVAC FLOOR PLANS. f�� 2. BRANCH & OPTIONAL BRANCH DUCT SIZES ARE BY THIS SCHEDULE UNLESS OTHERWISE NOTED ON HVAC FLOOR PLANS. ��E-- 3. ALL AIR DEVICES INSTALLED IN INACCESSIBLE AND /OR DRYWALL CEILINGS SHALL BE PROVIDED WITH MANUAL OPPOSED BLADE DAMPERS. RISE IN DUCTWORK 4• ALL AIR DEVICES INSTALLED IN ACCESSIBLE AND /OR LAY -IN CEILINGS SHALL HAVE A E RETURN OR EXHAUST D• _ E � r ,1 ,� r ': 1 .`1 1. .. �. 1.., .,.. CONDENSER WATER RETURN MANUAL VOLUME DAMPER INSTALLED IN THE BRANCH TAKE -OFF. 2/12 © ♦5:: O r' 1 'Tw � ", ',:1 1,, r1 Y 1 .� HWS HOT WATER SUPPLY r , 11 i r, ;�: m � 1 r• a•. 1 :•� 1 , .., , PRESSURE DROP FOR ALL AIR DEVICES SHALL NOT EXCEED 0.10 IN. W.G. BELLMOUTH CONN. 2/12 © 1 Y',77 0 1 r• 1 ' �•. ® '�� I.w r1 Y r ALL AIR DEVICES SHALL BE WHITE UNLESS OTHERWISE NOTED. 36x9 rl '.1 • L'. :• HWR MVD ROUND ADAPTER 7. O �.�....1..1. 1 . �i r► l 1.11• 1'.' � •,.. , 1 , 1'� CHS SUPPLY • : :',rj •.1,.7• al• al• 1.�1 ••rr 1 1• 34.8 3.0 8. ALL AIR DEVICES SHALL BE ALUMINUM CONSTRUCTION UNLESS OTHERWISE � 1 1•,n:l 1 'rw � r •rr w ' � r ;� r•, W DIFFUSER 9. THROW VALUES ARE GIVEN FOR TERMINAL VELOCITIES OF 150, 100 & 50 FPM RESPECTIVELY. TR OR GRILLE MARK 1.: : �Q,. :1 © 1. 1 ',T Il: 1 �® E 1 �• � rMall.'�3. yl 1'w 111 1': ' ':r ',: ® ©® S D DUCT SMOKE DETECTOR F�,. �;... �1�.� ► a ',11 !'�::. Y C; Il. 1 ® ®�� 8x6 / 6'0 ©� 2 -3 -6 ':�1 .1 O ©O 4 W � VARIABLE FREQUENCY DRIVE a 1 � 1 ®I i', 1 ri � 1 • f ►f .11 !;ILL 1� , r, 1. (D 0 0 U AHU COMPONENT DIAGRAM (SMH -6) 0 rrl n • r © lr3A Y11!' O HOT WATER REHEAT COIL SCHEDULE MAX. WTR. PRESS. DROP = 5 FT. MAX. FACE VELOCITY = 650 FT /MIN. MAX. A.P. DROP = .5' W.C. TRANSITION DUCT TO ACCOMODATE AIR DEVICE SCHEDULE CFM COIL SIZE I 1. AIR DEVICE SIZES & SCHEDULED AIRFLOW ARE BY THIS SCHEDULE UNLESS OTHERWISE NOTED ON HVAC FLOOR PLANS. f�� 2. BRANCH & OPTIONAL BRANCH DUCT SIZES ARE BY THIS SCHEDULE UNLESS OTHERWISE NOTED ON HVAC FLOOR PLANS. ��E-- 3. ALL AIR DEVICES INSTALLED IN INACCESSIBLE AND /OR DRYWALL CEILINGS SHALL BE PROVIDED WITH MANUAL OPPOSED BLADE DAMPERS. RISE IN DUCTWORK 4• ALL AIR DEVICES INSTALLED IN ACCESSIBLE AND /OR LAY -IN CEILINGS SHALL HAVE A E RETURN OR EXHAUST D• _ E DROP IN DUCTWORK CWR CONDENSER WATER RETURN MANUAL VOLUME DAMPER INSTALLED IN THE BRANCH TAKE -OFF. 2/12 _ CONICAL TEE CONN. HWS HOT WATER SUPPLY 5. MAXIMUM PRESSURE DROP FOR ALL AIR DEVICES SHALL NOT EXCEED 0.10 IN. W.G. BELLMOUTH CONN. 2/12 BRANCH MAIN RUNOUT SQUARE TO 6. ALL AIR DEVICES SHALL BE WHITE UNLESS OTHERWISE NOTED. 36x9 55/100 HWR MVD ROUND ADAPTER 7. MAXIMUM NC RATING FOR ALL AIR DEVICES SHALL NOT EXCEED 25. CHS SUPPLY 120 R. �-- RILLE & AIR 34.8 3.0 8. ALL AIR DEVICES SHALL BE ALUMINUM CONSTRUCTION UNLESS OTHERWISE U AHU COMPONENT DIAGRAM (SMH -6) 0 rrl n • r © lr3A Y11!' O HOT WATER REHEAT COIL SCHEDULE MAX. WTR. PRESS. DROP = 5 FT. MAX. FACE VELOCITY = 650 FT /MIN. MAX. A.P. DROP = .5' W.C. TRANSITION DUCT TO ACCOMODATE AIR DEVICE SCHEDULE CFM COIL SIZE PIPING 1. AIR DEVICE SIZES & SCHEDULED AIRFLOW ARE BY THIS SCHEDULE UNLESS OTHERWISE NOTED ON HVAC FLOOR PLANS. MIN. ROWS/ MAX. FPI 2. BRANCH & OPTIONAL BRANCH DUCT SIZES ARE BY THIS SCHEDULE UNLESS OTHERWISE NOTED ON HVAC FLOOR PLANS. ��E-- 3. ALL AIR DEVICES INSTALLED IN INACCESSIBLE AND /OR DRYWALL CEILINGS SHALL BE PROVIDED WITH MANUAL OPPOSED BLADE DAMPERS. RISE IN DUCTWORK 4• ALL AIR DEVICES INSTALLED IN ACCESSIBLE AND /OR LAY -IN CEILINGS SHALL HAVE A E RETURN OR EXHAUST D• _ E DROP IN DUCTWORK CWR CONDENSER WATER RETURN MANUAL VOLUME DAMPER INSTALLED IN THE BRANCH TAKE -OFF. 2/12 _ CONICAL TEE CONN. HWS HOT WATER SUPPLY 5. MAXIMUM PRESSURE DROP FOR ALL AIR DEVICES SHALL NOT EXCEED 0.10 IN. W.G. BELLMOUTH CONN. 2/12 BRANCH MAIN RUNOUT SQUARE TO 6. ALL AIR DEVICES SHALL BE WHITE UNLESS OTHERWISE NOTED. 36x9 55/100 HWR MVD ROUND ADAPTER 7. MAXIMUM NC RATING FOR ALL AIR DEVICES SHALL NOT EXCEED 25. CHS SUPPLY 120 R. �-- RILLE & AIR 34.8 3.0 8. ALL AIR DEVICES SHALL BE ALUMINUM CONSTRUCTION UNLESS OTHERWISE NOTED. QUANTITY W DIFFUSER 9. THROW VALUES ARE GIVEN FOR TERMINAL VELOCITIES OF 150, 100 & 50 FPM RESPECTIVELY. TR OR GRILLE MARK MFGR & MODEL CFM RANGE FACE SIZE ! NECK SIZE BRANCH DUCT SIZE THROW E REMARKS ELBOW -� REHEAT COIL MODULE SIZE '�� �- DIVIDED FLOW FITTINGS S D DUCT SMOKE DETECTOR A TITUS TMS -AA 0 - 100 12x12 / 12x12 614) 8x6 / 6'0 2 -3 -6 V.F.D. VARIABLE FREQUENCY DRIVE B TITUS TMS -AA 101- 200 24x24 / 24x24 810 10x6 / 810 3 -5 -9 C TITUS TMS -AA 201- 325 24x24 / 24x24 1010 12x8 / 1010 4 -6 -13 1 TITUS 50F 0 - 180 8x8 / IOxIO 8x8 10x6 f 810 - 2 TITUS 50F 181 - 300 IOxIO / 24x24 IOxIO 12x8 / 10'0 - 3 TITUS 50F 301- 450 12x12 / 24x24 12x12 14x40 / 1210 - 4 TITUS 35OFS 525 -550 12x24 / 14x26 12x24 12x24 U AHU COMPONENT DIAGRAM (SMH -6) 0 rrl n • r © lr3A Y11!' O HOT WATER REHEAT COIL SCHEDULE MAX. WTR. PRESS. DROP = 5 FT. MAX. FACE VELOCITY = 650 FT /MIN. MAX. A.P. DROP = .5' W.C. TRANSITION DUCT TO ACCOMODATE HVAC LEGEND (DENT. CFM COIL SIZE PIPING MBH GPM Q 140 °F HOT WATER BRANCH PIPE SIZE MIN. ROWS/ MAX. FPI REMARKS DUCTWORK 200 9X9 ��E-- SHUT -OFF VALVE ® E SUPPLY DUCTWORK R RISE IN DUCTWORK CWS CONDENSER WATER SUPPLY E RETURN OR EXHAUST D• _ E DROP IN DUCTWORK CWR CONDENSER WATER RETURN DUCTWORK FD E FIRE DAMPER 2/12 _ CONICAL TEE CONN. HWS HOT WATER SUPPLY (Q} FSD COMBINATION FIRE &►- ``U 14.5 BELLMOUTH CONN. 2/12 PROVIDE DUCT MOUNTING FLANGE SMOKE DAMPER 1400 36x9 55/100 HWR HOT WATER RETURN CHILLED WATER 344 SUPPLY DIFFUSER & AIR QUANTITY 2/12 PROVIDE DUCT MOUNTING FLANGE 45° THROAT TAP BRANCH CONNECTION CHS SUPPLY 120 R. �-- RILLE & AIR 34.8 3.0 314 2/12 PROVIDE DUCT MOUNTING FLANGE QUANTITY W CHR RETURN WATER ® 160 E. E EXHAUST GRILLE & AIR QUANTITY TR RADIUS ELBOW R /W =1.5 THERMOSTAT (ADJUST.) I TURNING VANES IN H HUMIDISTAT E ELBOW -� REHEAT COIL '�� �- DIVIDED FLOW FITTINGS S D DUCT SMOKE DETECTOR M.V.D. MANUAL VOL.DAMPER V.F.D. VARIABLE FREQUENCY DRIVE U AHU COMPONENT DIAGRAM (SMH -6) 0 rrl n • r © lr3A Y11!' O HOT WATER REHEAT COIL SCHEDULE MAX. WTR. PRESS. DROP = 5 FT. MAX. FACE VELOCITY = 650 FT /MIN. MAX. A.P. DROP = .5' W.C. TRANSITION DUCT TO ACCOMODATE COIL AS REQUIRED. (DENT. CFM COIL SIZE EAT /LAT MBH GPM Q 140 °F HOT WATER BRANCH PIPE SIZE MIN. ROWS/ MAX. FPI REMARKS HWC -6 -12 200 9X9 55/85 6,5 0.5 34 2/12 PROVIDE DUCT MOUNTING FLANGE HWC-6 -13 635 21x9 55/85 20.5 2.0 3/4 2/12 PROVIDE DUCT MOUNTING FLANGE HWC -6 -14 450 15x9 55/85 14.5 1.5 3A 2/12 PROVIDE DUCT MOUNTING FLANGE HWC -6 -15 1400 36x9 55/100 68.0 5.5 If 2/12 PROVIDE DUCT MOUNTING FLANGE HWC -6 -16 1075 27x9 55/85 34.8 3.0 314 2/12 PROVIDE DUCT MOUNTING FLANGE MECHANICAL DEMOLITION NOTES 1. FOR EQUIPMENT AND SYSTEMS TO REMAIN IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE CONDITION OF, EXACT SIZES AND LOCATION OF EXISTING DUCT AND PIPING ETC. BEFORE DEMOLITION WORK IS BEGUN. REPORT ANY DISCREPANCIES BETWEEN PLANS AND ACTUAL FIELD CONDITIONS TO THE OWNER AND ENGINEER PRIOR TO THE COMMENCEMENT OF DEMOLITION WORK. 2. REMOVE THE INDICATED HVAC ITEMS AS SHOWN ON PLANS, THIS INCLUDES ALL HANGERS, STRAPS AND RELATED MATERIAL. AS DIRECTED THIS MATERIAL SHALL BE REMOVED FROM THE SITE OR TURNED OVER TO THE OWNER (AS DIRECTED BY THE OWNER). 3. CAP AND SEAL AIR TIGHT ALL POINTS AT WHICH DUCTWORK IS REMOVED FROM DUCTWORK THAT WILL REMAIN. 4. PATCH AND MATCH OPENINGS IN WALLS TO MAINTAIN THE INTEGRITY OF THE WALL WHERE AIR DEVICES, DUCTS, PIPING, ETC. HAVE BEEN REMOVED. (MAINTAIN THE EXISTING RATINGS). 5. CONTRACTOR SHALL VERIFY CLEARANCE REQUIREMENTS AND INDICATE ROUTING OF NEW DUCTWORK BEFORE FABRIC�tTION BEGINS AS RISES AND DROPS MAY BE NECESSARY DUE TO EXISTING FIELD CONDITIONS. 6. ALL DEMOLITION WORK SHALL COMPLY WITH NFPA 241 AND THE REQUIREMENTS OF THE OWNER. SEQUENCE OF OPERATION UPON ACTIVATION OF ANY FIRE ALARM DEVICE IN THE AREA SERVED BY ANY AIR HANDLING UNIT OR EXHAUST FAN, ALL EQUIPMENT AND ASSOCIATED FSD'S SHALL DE- ENERGIZE. FANS IDENTIFIED AS EXHAUSTING HAZARDOUS MATERIAL SHALL RUN CONTINUOUSLY. 9 s ■ • DUCTWORK L INTERIOR SUPPLY AND RETURN AIR DUCTWORK IN CEILING SPACE (WITH ROOF INSULATION >1312): 2' THICK, R -6.0 MIN, FIBERGLASS. PIPING I. CPIPLED2WpARERESS ING -,(FO HICK LASS MIN. K =.27) -PIPES 21A OR LARGER /1 = 2' THICK HVAC DESIGN REQUIRES SHEET NUMBER YES NO DUCT SMOKE DETECTOR(S) X SECOND FLOOR - CONSTRUCTION ZONE VENTILATION PLAN - MECHANICAL FIRE DAMPER(S) X MIJ SMOKE DAMPER(S) X THIRD FLOOR PLAN- DEMOLITION - MECHANICAL FIRE RATED ENCLOSURE THIRD FLOOR PLAN- NEW CONSTRUCTION - MECHANICAL X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY M3.1 X FIRE STOPPING (SEE ARCH.) MECHANICAL DETAILS X SMOKE CONTROL X MECHANICAL ROOM NOTES 1. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL DRAWINGS FOR COORDINATING ALL INSTALLED MATERIALS. 2. EQUIPMENT SIZES AND SERVICES SPACE REQUIREMENTS MAY VARY BETWEEN DIFFERENT MANUFACTURERS. CONSULT MANUFACTURER INSTALLATION DRAWINGS SUBMITTED AND APPROVED FOR APPLICATION WITH MECHANICAL ROOM EQUIPMENT. 3. DO NOT BLOCK TUBE PULL OR SERVICE SPACE ON EQUIPMENT WITH PIPING DUCTWORK, ETC.FLANGED OR REMOVABLE SECTIONS MAYBE USED IN SOME INSTANCES WHERE TIGHT CLEARANCES EXIST. 4. REFER TO DRAWINGS AND EQUIPMENT SCHEDULES FOR BRANCH PIPE SIZES TO INDIVIDUAL EQUIPMENT. 5. ALL CAPPED LINES FROM EQUIPMENT SHALL BE IDENTIFIED WITH STENCILED SERVICE. TYPE WITHIN 3'-O' OF CAP. 6• PIPE DRAIN LINES FROM EQUIPMENT TO NEAREST FLOOR DRAIN. REFER TO DRAWINGS FOR LOCATIONS OF FLOOR DRAINS. 7. PROVIDE BELT GUARDS FOR ANY EXTERNALLY BELT DRIVEN EQUIPMENT. TEST &BALANCE NOTES 1. FINAL CONSTRUCTION: UPON COMPLETION OF THE HVAC RENOVATION WORK, THE SAME CONTRACTOR SHALL REBALANCE THE NEW AND EXISTING EQUIPMENT AND DUCTS TO PROVIDE INDICATED AIR QUANTITIES TO THE RENOVATED SPACE. ANY ADDITION OF DAMPERS, ADJUSTMENTS, (FAN SPEED, CHANGE OUT OF PULLEYS, ETC.) REQUIRED FOR THIS SHALL BE INCLUDED IN THIS CONTRACTORS PROPOSAL. 2. FINAL REPORT• . SUBMIT FINAL TEST AND BALANCE REPORT TO ENGINEER FOR REVIEW AND ACCEPTANCE ONE WEEK PRIOR TO FINAL AHCA INSPECTION FOR EACH PHASE. DRAWING INDEX SHEET NUMBER SHEET TITLE MO.1 MECHANICAL SCHEDULES, LEGEND, NOTES AND DRAWING INDEX MO.2 SECOND FLOOR - CONSTRUCTION ZONE VENTILATION PLAN - MECHANICAL MO.3 THIRD FLOOR - CONSTRUCTION ZONE VENTILATION PLAN - MECHANICAL MIJ THIRD FLOOR PLAN- DEMOLITION - MECHANICAL M1.2 THIRD FLOOR PLAN- DEMOLITION - MECHANICAL M2.1 THIRD FLOOR PLAN- NEW CONSTRUCTION - MECHANICAL M2.2 THIRD FLOOR PLAN- NEW CONSTRUCTION - MECHANICAL M3.1 MECHANICAL DETAILS M3.2 MECHANICAL DETAILS M4.1 MECHANICAL CONTROLS >- W �o cot I- C) UCl) LL d W w Q I-- a w Ce. 0 g Q N w Q m a v E � Of w O c� a N � z Q ^� o N 1` C) g o Z U. w SSAL Smith Reckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX. (954) 421 -1466 www.ssr- inc.com Firm Certification - EB- 4000857 PE.5mm dohs E Atadwd PE - 9320° W.b. tA.9te..rd PF -65701 SSB JOB # 1132063.0 cc O V Z J ♦♦Q� MV C.. F- w F- 0) IM cf) r 0 UNIONS 0 CO cc LL CO J a I- = w C H n- 0 0 C5 a H Z J w O W o = Q cn H �- 11,.- 0) C0 _ 3:: 0 t... CO U •a( 000 0 M C0 • 1108 7.00 0 r, Revised: AHCA COMMENTS/ COORDINATION 2/6/12 ASI #3 e 10/31/12 ` a V,. m w" Q 'tn r ►'1 l�� l �"A ►'1 l�� l