12-509-060PARTIAL NURSE CALL RISER NTS PANEL IICS321I OCRITICAL BRANCH 0 FED FROM "CDP" ENGRAVED ORANGE MICARTA PLATE WITH WHITE LETTERS 3RD FLOOR NURSE CALL SYSTEM NOTES: NI. CODE BLUE SHALL BE ANNUNCIATED AT THE MASTER ALARM PANEL SERVING THE AREA AND PBX. N2. ALL NEW DEVICES (HILSHALL ,BE CONNECTED TO THE EXISTING NICU NURSE N3. BYLOWNER SE VENDOR ALL CABLES ABOVE CEILING SHALLEBEASUPPORTED BY J -HOOK. N4. COORDINATE WITH NURSE CALL VENDOR FOR EXACT ROUTING OF CONDUIT N5. PROVIDE 34 CONDUIT STUBBED 6' ABOVE ACCESSIBLE CEILING IN CORRIDOR FOR EACH DEVICE. N6. NURSE CALL CABLING SHALL BE PLENUM RATED. THE NUMBER OF CONDUCTORS SHALL BE AS REQUIRED BY THE VENDOR. N7. PROVIDE SYSTEM RE- CERTIFCATION TO AHJ AT FINAL INSPECTION. N8. STAFF ASSIST SHALL BE ANNUNCIATED AT THE MASTER STATION SERVING THE AREA AND AT ALTERNATE LOCATION AS DIRECTED BY THE OWNER VIA THE USE OF A DUTY STATION. PROVIDE ENGRAVED PLATE AT THE DUTY STATION TO READ 'STAFF ASSIST' AND IDENTIFY THE SUITE BEING ANNUNCIATED IN ACCORDANCE WITH OWNERS SUITE IDENTIFICATION. N9. COORDINATE ALL NURSE CALL WORK WITH THE OWNER AND THE OWNER'S VENDOR. MD. NURSE CALL RISER DOES NOT INDICATE ALL REQUIRED DEVICES. REFER TO FLOOR PLANS FOR LOCATION AND QUANTITIES. N11. PROVIDE BACKBOXES AND CONDUIT AS REQUIRED BY OWNER'S VENDOR. S EXISTING FATC ` 3/4C. MIN. TYPICAL EXISTING LSL3S -7.9 120VAC LIFE SAFETY CIRCUIT EXISTING NORTH TOWER FIRE ALARM CONTROL PANEL NODE. —i THERE IS AN EXISTING FIRE ALARM ANNUNCIATOR PBX. TO ADDTIONAL DEVICES REFER TO FLOOR PLANS FOR QUANTITY OF DEVICES THIRD FLOOR UIKUUi I FIRE ALARM RISER DIAGRAM NO SCALE FIRE ALARM SYSTEM NOTES: A. ALL NEW DEVICES SHALL BE SIMPLEX TO MATCH EXISTING OR THE LATEST GENERATION OF DEVICES. B. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING VENDOR ' SHOP DRAWINGS INDICATING ALL MODEL NUMBERS, (MIRING REQUIREMENTS AND BATTERY CALCULATIONS. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY FLORIDA REGISTERED ENGINEER. C. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL SYSTEMS EQUIPMENT AND CABLE AND ALL INSTALLATIONS. D. REFER TO FIRE ALARM MANUFACTURERS' RECOMMENDATIONS FOR CONDUIT AND CONDUCTOR SIZE AND TYPES. REFER TO SPECIFICATIONS. E. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HARDWARE AND SOFTWARE TO SUPPORT EXTENSION OF FIRE ALARM SYSTEM. F. VISUAL DEVICES TO BE IN SYNC WITH EACH OTHER AND AUDIBLE DEVICES TO BE IN SYNC WITH EACH OTHER. G. STROBES TO BE T5 CANDELA EVERYWHERE. H. EACH SMOKE CAMPARTMENT SHALL BE ANNUNCIATED AS A SEPARATE FIRE ALARM ZONE. A FIRE ALARM SYSTEM ZONE SHALL NOT INCLUDE ROOMS OR TO SA AM MAXIMUM OF OTHER 2SMOKE 5 QUARE FEET (2009 318 HSQUARE METERS) FBC (2007 W/2009 RSV) 419.3.16, 907.6.11 NFPA T2 (2002), 4.4.6.1.2. I. PROVIDE SYSTEM CERTFICATION AT CONCLUSION OF PROJECT. J. PROVIDE SMOKE DETECTOR SENSITIVITY REPORT AT CONCLUSION OF PROJECT. FIRST FLOOR 0 0 9 A SEE SPECIFICATIONS 2 - #22, 2 CONDUCTOR BELL WIRE IN Y2 "C. O [sl J BLOOD BANK REFRIG. REMOTE MONITOR ' AT PBX /RECEPTIONEST LOCATION NOTE: SEE ARCHITECTURAL PLANS FOR EXACT LOCATION AND COORDINATE WITH BLOOD BANK EQUIPMENT PRIOR TO INSTALLATION. kRD IDENTIFICATION BLOOD BANK WIRING DIAGRAM NTS � 1 1 1 1 � STRUCTURE ABOVE �` ATTACH CADDY ANGLE — BRACKETS (TYPICAL) MINIMUM THREE TWISTS ATTACH CADDY ANGLE BRACKET WITH *18 *12 GAUGE GALVANIZED SELF- TAPPING SHEET- WIRE HANGER (TYPICAL) MINIMUM 15% OFF VERTICAL BOTH DIRECTIONS i / e TYPICAL LIGHTING FIXTURE FIXTURE SUPPRORT NOTES: 1. ATTACH ALL LIGHT FIXTURES TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. 2. ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING LESS THAN 56 POUNDS SHALL BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY DUTY GRID SYSTEM AND THEY MUST HAVE A MINIMUM OF TWO •12 GAUGE SLACK SAFETY WIRES ATTACHED AT DIAGONAL CORNERS AND ANCHORED TO THE STRUCTURE ABOVE. 3. ALL FIXTURES SUPPORTED ON INTERMEDIATE DUTY GRID SYSTEMS MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR TAUT •12 GAUGE WIRES ATTACHED TO THE STRUCTURE ABOVE. 4. ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING MORE THAN 56 POUNDS MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR •12 GAUGE TAUT WIRES ATTACHED TO THE STRUCTURE ABOVE REGARDLESS OF THE TYPE OF CEILING GRID SYSTEM USED. 5. THE FOUR TAUT •12 GAUGE WIRES INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE MUST BE CAPABLE OF SUPPORTING FOUR TIMES THE WEIGHT OF THE UNIT. SEAL PENETRATIONS SO AS TO MAINTAIN RATING OF WALL FOR FIRE PROOFING.— FIRE RATED WALL CONDUIT SEAL AT BOTH ENDS SO AS TO MAINTAIN RATING OF WALL FOR FIRE PROOFING. RATED WALL PENETRATION Wx12" AIR TERMINAL CAST BRONZE TERMINAL BONDING LUG LEADED. SECURE WITH TWO %"x- STAINLESS STEEL SCREWS AND A Y4" STAINLESS STEEL NUT. MAIN CONDUCTOR LIGHT FIXTURE SUPPORT DETAIL NTS TYPICAL EXHAUST FAN BOND CONNECTION 2 •12, 1 *12G.3/4 CONDUIT (TYPICAL 20 AMP BRANCH CIRCUIT) NTS LIGHT FIXTURE WHERE INDICATED. 2 •12,1'12G.3/4 CONDUIT (TYPICAL 20 AMP BRANCH CIRCUIT) •IOG. BONDED TO BACKBOXES OF Al 1 r1CVIPCC TO REMAINING METALLIC DEVICES 8 AWG —3/� CONDUIT " IN THE PATIENT VICINITY. 2 "12,1 •12G.3/ CONDUIT TO C TELEPHONE OUTLET BACKBOX . Vx REMAINING ROOM RECEPTACLES NURSE CALL DEVICE BACKBOX DUPLEX RECEPTACLES (BOND OUTLET BOX AND GROUND PIN OF RECEPTACLE WITH GROUND) CRITICAL CARE PATIENT AREA GROUNDING DETAIL NTS SECONDARY BONDING WIRE. CENTERLINE B CABLE MAXIMUM 8" ABOVE FINISHED ROOF CAST BRONZE PARALLEL COMBINATION CABLE TO WIRE SPLICER. G— PHASE CONDUCTORS N— NEUTRAL AND GROUND C — CONDUCTORS. SEE RIStRj B_ DIAGRAM FOR SIZE. A _ BYE NOTESe OR W Q ♦♦~^^ v♦ OR OO O r co CO 4 O � _j LL _ � g CO 1— —J w VENDOR. Q [L � V (1) Cl) c W Z a.J W _ � H SYSTEMS RESPONSIBILTY W' Drawn: SYSTEM INTERIOR CABLE FURNISHED BYe o EXTENT OF CONDUTi eeeeeeee� EQUIPMENT INSTALLED M1 n ... VENDOR co Q VENDOR VEND TELEPHONE Z VENDOR CL I`3 �10 VENDOR M COMPUTER U� J Q Q W LL W Q CATV VENDOR W 0 Q VENDOR VEND g FIRE ALARM Q L EC EC THROUGHOUT EC EC PAGING VENDOR ui THROUGHOUT VENDOR U� Q m a U W O U 0 N 0 a U W U NoTm Qi O Q 0 EC= ELECTRICAL CONTRACTOR VENDOR = OWNER FURNISHED, OWNER INSTALLED OUTLETS AMPLIFIERS BE ELECTRICAL CONTRACTOR, MOUNTS BY GENERAL CONTRACTOR, TV BY L STUB -UP TO ABOVE ACCESSIBLE CEILING SPACE, TERMINATE WITH PLASTIC BUSHING. ALL CABLES SHALL BE PLENUM RATED OR INSTALLED IN CONDUIT THROUGHOUT DO NOT �TS�' 0 0 a� o Smi th SSIAL Reid, Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX; (954) 421-1466 www.ssr - inc.com Firm Certification -EB- 0000857 D—d.D.0 hr.b.dA. A ' ra,aatn 16 701 SSRdOB t 1192065.0 BYE NOTESe OR W Q ♦♦~^^ v♦ OR OO O r co CO 4 O � _j LL _ � g CO 1— —J w VENDOR. Q [L � V (1) Cl) c W Z a.J W _ � H SYSTEMS RESPONSIBILTY SCHEDULE Drawn: SYSTEM INTERIOR CABLE FURNISHED BYe INTERIOR CABLE INSTALLED BYe EXTENT OF CONDUTi EQUIPMENT F(IRNISFED BYe EQUIPMENT INSTALLED NURSE CALL VENDOR U Q VENDOR VEND TELEPHONE Z VENDOR VENDOR I`3 VENDOR VENDOR J COMPUTER VENDOR VENDOR Q Q VENDOR CATV VENDOR U_ Q VENDOR VEND FIRE ALARM LL. EC EC THROUGHOUT EC EC PAGING VENDOR VENDOR THROUGHOUT VENDOR VENDOR NoTm Qi O Q 0 EC= ELECTRICAL CONTRACTOR VENDOR = OWNER FURNISHED, OWNER INSTALLED OUTLETS AMPLIFIERS BE ELECTRICAL CONTRACTOR, MOUNTS BY GENERAL CONTRACTOR, TV BY L STUB -UP TO ABOVE ACCESSIBLE CEILING SPACE, TERMINATE WITH PLASTIC BUSHING. ALL CABLES SHALL BE PLENUM RATED OR INSTALLED IN CONDUIT THROUGHOUT DO NOT �TS�' I NORMAL SYSTEMS BRANCH PANELBOARD I I r7 PE R .42.:Ta��.. TW Q F''IrE'. A.1ann con( c . s 0 ' p! :.*2,S shall C be subr;u! t Lt2'' L,. i .. i f Si D4l.:C. #,YaJ? d y 1. A (�,i4p 1 Llt. � O Approved m c:a1 or Bc rig Pennit oayt � I..� co V date �ir o G ay O o 0 PHASE CO N C NEUTRAL AND GROUND B CONDUCTORS. SEE RISER A DIAGRAM FOR SIZE. Comm. No: ;11087.00 PHASE BUS (TYPICAL) NEUTRAL BUS (TYPICAL) CRITICAL BRANCH PANEL BOARD GROUND BUS (TYPICAL) *10 AWG IN 3/4 CONDUIT SYSTEMS RESPONSIBILTY SCHEDULE Drawn: SYSTEM INTERIOR CABLE FURNISHED BYe INTERIOR CABLE INSTALLED BYe EXTENT OF CONDUTi EQUIPMENT F(IRNISFED BYe EQUIPMENT INSTALLED NURSE CALL VENDOR VENDOR Q VENDOR VEND TELEPHONE VENDOR VENDOR I`3 VENDOR VENDOR COMPUTER VENDOR VENDOR Q VENDOR VENDOR CATV VENDOR VENDOR Q VENDOR VEND FIRE ALARM EC EC THROUGHOUT EC EC PAGING VENDOR VENDOR THROUGHOUT VENDOR VENDOR NoTm Qi O Q 0 EC= ELECTRICAL CONTRACTOR VENDOR = OWNER FURNISHED, OWNER INSTALLED OUTLETS AMPLIFIERS BE ELECTRICAL CONTRACTOR, MOUNTS BY GENERAL CONTRACTOR, TV BY L STUB -UP TO ABOVE ACCESSIBLE CEILING SPACE, TERMINATE WITH PLASTIC BUSHING. ALL CABLES SHALL BE PLENUM RATED OR INSTALLED IN CONDUIT THROUGHOUT DO NOT �TS�' I NORMAL SYSTEMS BRANCH PANELBOARD I I r7 PE R .42.:Ta��.. TW Q F''IrE'. A.1ann con( c . s 0 ' p! :.*2,S shall C be subr;u! t Lt2'' L,. i .. i f Si D4l.:C. #,YaJ? d y 1. A (�,i4p 1 Llt. � O Approved m c:a1 or Bc rig Pennit oayt � I..� co V date �ir o G ay O o 0 PHASE CO N C NEUTRAL AND GROUND B CONDUCTORS. SEE RISER A DIAGRAM FOR SIZE. Comm. No: ;11087.00 PHASE BUS (TYPICAL) NEUTRAL BUS (TYPICAL) CRITICAL BRANCH PANEL BOARD GROUND BUS (TYPICAL) *10 AWG IN 3/4 CONDUIT PRINTED 24 "X36" NOT TO SCALE ���iillllll //� MIN 06 %. O 1 ]OLL' ��llllllll� E5.1 Date: 01/18/12 Drawn: Revised: PRINTED 24 "X36" NOT TO SCALE ���iillllll //� MIN 06 %. O 1 ]OLL' ��llllllll� E5.1