12-509-052
0 LEGEND LEGEND [�� DESCRIPTION MOUNTING HEIGHT EQUIPMENT ABC MOUNTING SYMBOL DESCRIPTION FUSED SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES /FUSED) PARTIAL FIRST FLOOR LOCATION REFERENCE PLAN ®i HEIGHT E1.1 WIRING FACTORY WIRED CONTROLLER OR EQUIP. -F.B.O CONDUIT & BRANCH CIRCUIT WIRING CONCEALED VFD VARIABLE FREQUENCY DRIVE (COORDINATE WITH MECHANICAL) (CONDUIT EXPOSED ON WALL OR CEILING & BRANCH CIRCUITING CLG MOTOR WIRING MGAP JUNCTION BOX / WALL MOUNTED HOMERUN TO PANELBOARD - NUMBER OF CIRCUITS IN MINIMUM 3/4 CONDUIT s UNLESS NOTED OTHERWISE FAULT CURRENT ANALYSIS & COORDINATION STUDIES NOTES: PANELBOARD - SURFACE MOUNTED I.ONE NEUTRAL CONDUCTOR FOR EACH PHASE CONDUCTOR,ALTHOUGH NOT PM INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. 2. ONE INSULATED GREEN GROUNDING CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL REFERENCE NOTE BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. CYQB 3. HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE (3) PHASE 88' AFF CONDUCTORS (ONE PER PHASE) PLUS THREE (3) NEUTRAL CONDUCTORS AND VARIABLE FREQUENCY DRIVE ONE (1) GROUND CONDUCTOR IN EACH CONDUIT. SOUND SYSTEM 4. MULTI -WIRE BRANCH CIRCUITS THAT SHARE A COMMON NEUTRAL SHALL NOT BE VOLUME CONTROL PERMITTED FOR INDIVIDUAL LINE -TO- NEUTRAL LOADS. MPR 5. EACH CIRCUIT (PHASE AND NEUTRAL CONDUCTORS) SHALL BE GROUPED TOGETHER QF USING CABLE TIES AT THE PANELBOARD AND ALL JUNCTION BOXES, PULL BOXES AND PAGING SPEAKER ALL OTHER LOCATIONS WHERE TERMINATIONS, CONNECTIONS OR SPLICES ARE MADE. NURSE CALL 6. ALL CONDUCTORS SHALL BE *12 AWG UNLESS OTHERWISE NOTED. LIGHTING F1 DESIGNATES FIXTURE TYPE - SEE LIGHTING FIXTURE SCHEDULE DUTY /STAFF AUDIO STATION WITH DISPLAY 54' AFF ® NURSE REMOTE LOCATOR RECEIVER BRANCH SURFACE OR RECESSED FLUORESCENT ® BED INTERFACE UNIT (SIDE -COM CONNECTION) ®NORMAL OO FIXTURE (TYPE DETERMINES MOUNTING) 42' AFF ® DOME LIGHT - A/B GRAPHICAL CRITICAL OR EQUIPMENT BRANCH SURFACE OR RECESSED FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) 8 INTERSECTION ZONE LIGHT - GRAPHICAL CLG NM SAFETY BRANCH SURFACE OR RECESSED FLUORESCENT DUCT MOUNTED SMOKE DETECTOR - DUCT ® ®LIFE- SMOKE DETECTOR REMOTE INDICATOR FIXTURE (TYPE DETERMINES MOUNTING) NURSE CALL TERMINAL CABINET a O NORMAL BRANCH SURFACE OR RECESSED FIXTURE POWER DISTRIBUTION CABINET SPRINKLER SYSTEM VALVE STATUS SWITCH (TYPE DETERMINES MOUNTING) CONSOLIDATED ROOM BOARD ABV CLG ® ® CRITICAL OR EQUIPMENT BRANCH SURFACE OR RECESSED FIXTURE Q INDIVIDUAL STAFF EMERGENCY STATION 54' AFF Q (TYPE DETERMINES MOUNTING) 54' AFF ® ® ® LIFE- SAFETY BRANCH SURFACE OR RECESSED FIXTURE W WALL TELEPHONE OUTLET (P -PAY PHONE) (F- FLOOR) AFF TO CL (TYPE DETERMINES MOUNTING) FLOOR a NORMAL BRANCH SURFACE OR SUSPENDED AFF TO TO CL ® FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) AS NOTED SEE SPECS. CRITICAL OR EQUIPMENT BRANCH SURFACE OR SUSPENDED ® FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) w O LIFE - SAFETY BRANCH SURFACE OR SUSPENDED FLUORESCENT ® FIXTURE (TYPE DETERMINES MOUNTING) V rO 4 NORMAL BRANCH WALL BRACKET FIXTURE CABLE /CAN SYSTEM 9 CRITICAL OR EQUIPMENT BRANCH WALL BRACKET FIXTURE 88'AFF LIFE- SAFETY BRANCH WALL BRACKET FIXTURE ®� EXIT LIGHT, PROVIDE DIRECTIONAL ARROWS AS INDICATED PATIENT MONITOR ON PLANS CCTV (P &T - PAN & TILT) t' BATTERY POWERED EMERGENCY LIGHT MOTION SENSOR SWITCHES S SINGLE POLE SWITCH - IVORY TOGGLE 3' -10' AFF TO CL ® CARD READER SINGLE POLE SWITCH - RED TOGGLE AFF' 101 3 AS NOTED THREE WAY SWITCH - RED TOGGLE AFF'TO,CL q FOUR WAY SWITCH - RED TOGGLE AFF3'-10' CL S3 THREE WAY SWITCH - IVORY TOGGLE 3' -10' AFF TO CL Sq FOUR WAY SWITCH - IVORY TOGGLE 3' -10' AFF TO CL SK SINGLE POLE SWITCH - KEY OPERATED 3' -10' AFF TO CL SD DIMMER SWITCH 3' -10' AFF TO CL SV VARIABLE INTENSITY CONTROL 3' -10' AFF TO CL $T MOTOR RATED SWITCH WITH THERMAL OVERLOAD PUSH BUTTON SWITCH (MUSHROOM BUTTON) AFF ' TO ' CL ® LINE VOLTAGE DUAL TECHNOLOGY OCCUPANCY SENSOR CEILING WATTSTOPPER CAT. *DTT -355 OR EQUAL &V LOW VOLTAGE DUAL TECHNOLOGY OCCUPANCY SENSOR W/2 POWER PACKS CEILING WATTSTOPPER CAT. *DT -300 WITH *BZ -50 POWER PACK OR EQUAL ©o LOW VOLTAGE ULTRASONIC CORRIDOR OCCUPANCY SENSOR W /POWER CEILING LVC PACK WATTSTOPPER CAT. *W -2000H WITH *BZ -50 POWER PACK OR EQUAL SM SINGLE POLE OCCUPANCY SENSOR SWITCH - PROVIDE IVORY DEVICE PLATE 3' -10' WATTSTOPPER CAT. *DW -100 OR EQUAL AFF TO CL $M SINGLE POLE OCCUPANCY SENSOR SWITCH - PROVIDE RED DEVICE PLATE 3' -10' WATTSTOPPER CAT. *DW -100 OR EQUAL AFF TO CL POWER - RECEPTACLES 120V. DUPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE V -6' ABBREVIATIONS FOR EXCEPTIONS) AFF TO CL 120V. DUPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT AS NOTED OR (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) SEE SPECS 120V. QUADPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE V -6' ABBREVIATIONS FOR EXCEPTIONS) AFF TO CL 120V. QUADPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT AS NOTED OR (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) SEE SPECS O 120V. DUPLEX RECEPTACLE -IVORY (REFER TO RECEPTACLE FLOOR BOX ABBREVIATIONS FOR EXCEPTIONS) 120V. DUPLEX RECEPTACLE -IVORY (REFER TO RECEPTACLE FLUSH TYPE ABBREVIATIONS FOR EXCEPTIONS) FLOOR BOX 250V., 2 -POLE, SINGLE RECEPTACLE, RATINGS AS SHOWN ON PLANS V -6' AFF TO CL V -6' AFF TO CL �- SPECIAL RECEPTACLE (TYPE AS NOTED) OR AS NOTED AS NOTED OR �- 120V. GFI DUPLEX RECEPTACLE (SPECIAL MOUNTING HEIGHT) SEE SPECS Q- 120V. GFI DUPLEX RECEPTACLE 11-6' OR HARDWIRED CONNECTION FOR FILM ILLUMINATOR AS NOTED ® PUSH PLATE (FURNISHED WITH DOOR HARDWARE) AFF'TO,CL LEGEND [�� DESCRIPTION MOUNTING HEIGHT EQUIPMENT ABC NON -FUSED SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES /NON- FUSED) EO.1 AFF FUSED SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES /FUSED) PARTIAL FIRST FLOOR LOCATION REFERENCE PLAN ®i COMBINATION MAGNETIC ACROSS- THE -LINE STARTER W /MOTOR CIRCUIT PROTECTOR E1.1 ® FACTORY WIRED CONTROLLER OR EQUIP. -F.B.O THIRD FLOOR NEW CONSTRUCTION - LIGHTING VFD VARIABLE FREQUENCY DRIVE (COORDINATE WITH MECHANICAL) E3.2 CLG MOTOR PARTIAL ELECTRICAL DISTRIBUTION DIAGRAMS MGAP JUNCTION BOX / WALL MOUNTED E6.1 s PANELBOARD - FLUSH MOUNTED FAULT CURRENT ANALYSIS & COORDINATION STUDIES PC PANELBOARD - SURFACE MOUNTED PM PHYSIOLOGICAL MONITOR 10 REFERENCE NOTE CYQB JUNCTION BOX FOR CONNECTION TO HVAC CONSTANT VOLUME BOX 88' AFF VFD VARIABLE FREQUENCY DRIVE SOUND SYSTEM �V VOLUME CONTROL 46'AFF MPR MUSIC AND PAGING RACK QF Q PAGING SPEAKER CLG NURSE CALL s ® E STAFF FULL FEATURED AUDIO STATION WITH DISPLAY AND CODE BLUE AND STAFF EMERGENCY ASSIST BUTTONS 54' AFF 0 DUTY /STAFF AUDIO STATION WITH DISPLAY 54' AFF ® NURSE REMOTE LOCATOR RECEIVER CLG ® BED INTERFACE UNIT (SIDE -COM CONNECTION) HEADWALL OO 2MERGFN OR PULL SWITCH WITH CORD TO EXTEND TO WITHIN 42' AFF ® DOME LIGHT - A/B GRAPHICAL CLG 8 INTERSECTION ZONE LIGHT - GRAPHICAL CLG NM NURSE CALL MASTER STATION DUCT MOUNTED SMOKE DETECTOR - DUCT ® NURSE CALL MINI - MASTER STATION SMOKE DETECTOR REMOTE INDICATOR IN_CT1 NURSE CALL TERMINAL CABINET SMOKE DETECTOR ALARM REMOTE INDICATOR /TEST SWITCH ® POWER DISTRIBUTION CABINET SPRINKLER SYSTEM VALVE STATUS SWITCH cRB CONSOLIDATED ROOM BOARD ABV CLG Q INDIVIDUAL SINGLE PATIENT STATION - SIGNAL ONLY (NO AUDIO) 54' AFF Q INDIVIDUAL STAFF EMERGENCY STATION 54' AFF Q INDIVIDUAL CODE BLUE STATION 54' AFF ® INDIVIDUAL CODE PINK STATION 54' AFF W WALL TELEPHONE OUTLET (P -PAY PHONE) (F- FLOOR) AFF TO CL VOICE /DATA OUTLET IN FLOOR FLOOR a VOICE /DATA OUTLET AFF TO TO CL VOICE /DATA OUTLET (SPECIAL MOUNTING HEIGHT) AS NOTED SEE SPECS. J = w O NOTES: I. THE ENTIRE LENS OF THE DEVICE TO BE MOUNTED 80' AFF OR 6' BELOW CEILING TO BOTTOM OF DEVICE WHICH EVER IS LOWER. 2. ALL DEVICES SHOWN MAY OR MAYNOT BE PART OF THIS PROJECT. ~ V m CABLE /CAN SYSTEM © CATV OUTLET FOR WALL MOUNTED TV (SEE MANUFACTURERS DETAIL) 88'AFF SPECIAL SYSTEMS Q PM PATIENT MONITOR Q4 CCTV (P &T - PAN & TILT) CEILING MTD. MOTION SENSOR CEILING MTD. ® PUSH PADDLE AFF 3' -10' ® CARD READER AFF TO CL * MASTER CLOCK SYSTEM DIGITAL CLOCK AS NOTED OC ET MASTER CLOCK SYSTEM ELAPSED TIME DIGITAL CLOCK AS NOTED O SOUND SYSTEM CEILING SPEAKER LEGEND SYMBOL DESCRIPTION MOUNTING HEIGHT ABBREVIATIONS ABC ABOVE COUNTER EO.1 AFF ABOVE FINISHED FLOOR PARTIAL FIRST FLOOR LOCATION REFERENCE PLAN AFG ABOVE FINISHED GRADE E1.1 C RED - EMERGENCY POWER THIRD FLOOR NEW CONSTRUCTION - LIGHTING CL CENTERLINE E3.2 CLG CEILING PARTIAL ELECTRICAL DISTRIBUTION DIAGRAMS MGAP MEDICAL GAS ALARM PANEL E6.1 OFCI OWNER FURNISHED CONTRACTOR INSTALLED FAULT CURRENT ANALYSIS & COORDINATION STUDIES PC PHOTO CELL PM PHYSIOLOGICAL MONITOR S SAFETY TYPE TV TELEVISION 88' AFF Wp WEATHERPROOF TL TWIST LOCK FIRE ALARM QF FIRE ALARM MANUAL PULL STATION AFF' T0• CL 10K ALARM MANUAL PULL STATION - KEY OPERATED ' • AFF AFFTOCL F� FIRE ALARM VISUAL DEVICE NOTE 1 F� FIRE ALARM AUDIBLE AND VISUAL DEVICE NOTE 1 ® FIRE ALARM SPEAKER. CEILING Q MAGNETIC DOOR HOLDER 1' -03 BELOW CLG Q FIRE ALARM SMOKE DETECTOR CEILING ® HEAT DETECTOR ITS DUCT MOUNTED SMOKE DETECTOR - "SUPPLY DUCT C0 QRETURN R DUCT MOUNTED SMOKE DETECTOR - DUCT cc RI SMOKE DETECTOR REMOTE INDICATOR ® SMOKE DETECTOR ALARM REMOTE INDICATOR /TEST SWITCH J LL SPRINKLER SYSTEM VALVE STATUS SWITCH ® SPRINKLER SYSTEM WATER FLOW SWITCH ® FIRE ALARM CONTROL PANEL ® FIRE ALARM RELAY (FOR SYSTEM SHUTDOWN) TELEPHONE /DATA J a � W W WALL TELEPHONE OUTLET (P -PAY PHONE) (F- FLOOR) AFF TO CL VOICE /DATA OUTLET IN FLOOR FLOOR a VOICE /DATA OUTLET AFF TO TO CL VOICE /DATA OUTLET (SPECIAL MOUNTING HEIGHT) AS NOTED SEE SPECS. J = w O NOTES: I. THE ENTIRE LENS OF THE DEVICE TO BE MOUNTED 80' AFF OR 6' BELOW CEILING TO BOTTOM OF DEVICE WHICH EVER IS LOWER. 2. ALL DEVICES SHOWN MAY OR MAYNOT BE PART OF THIS PROJECT. INFECTION CONTROL MEASURES I. CONTRACTOR SHALL OBTAIN FROM THE OWNER A COPY OF THE INFECTION CONTROL RISK ASSESSMENT (ICRA) PREPARED FOR THIS PROJECT. CONTRACTOR SHALL REVIEW THE REQUIREMENTS IN THE REPORT AND PERFORM ALL WORK IN ACCORDANCE WITH THOSE REQUIREMENTS. CONTRACTOR SHALL STRICTLY ADHERE TO THE LIMITS OF THE CONSTRUCTION AREA, AND WHERE PHASING APPLIES SHALL ADHERE TO THE PHASING PLAN. ANY WORK OUTSIDE THE CONSTRUCTION AREA SHALL BE COORDINATED WITH THE OWNER AND PERFORMED IN ACCORDANCE WITH THE ICRA REPORT, UNDER THE SUPERVISION OF THE OWNER'S REPRESENTATIVE OR OTHER DESIGNATED ICRA COMMITTEE OFFICER. 2. TO THE EXTENT THAT IT IS REQUIRED BY THE ICRA, THE CONTRACTOR SHALL ENDEAVOR TO MAINTAIN EXISTING LEVELS OF INDOOR AIR QUALITY IN AREAS SURROUNDING AND ADJACENT TO THE CONSTRUCTION WORK ZONE, AND ELSEWHERE IN THE FACILITY. IT SHOULD BE ANTICIPATED THAT THE ICRA REPORT WILL REQUIRE MEASURES TO THIS EFFECT INCLUDING ERECTION OF CONSTRUCTION ZONE BARRIERS AND PROVISION OF NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE RELATIVE TO OTHER AREAS OF THE FACILITY. DRAWING INDEX SHEET NUMBER SHEET TITLE EO.1 ELECTRICAL SCHEDULES, LEGENDS AND DRAWING INDEX EO.2 PARTIAL FIRST FLOOR LOCATION REFERENCE PLAN EO.3 PARTIAL THIRD FLOOR DEMOLITION & NEW CONSTRUCTION E1.1 THIRD FLOOR DEMOLITION- ELECTRICAL E2.1 THIRD FLOOR NEW CONSTRUCTION - LIGHTING E3.1 THIRD FLOOR NEW CONSTRUCTION - POWER & SYSTEMS E3.2 PARTIAL THIRD FLOOR PLAN- DEMOLITION AND NEW CONSTRUCTION- ELECTRICAL E4.1 PARTIAL ELECTRICAL DISTRIBUTION DIAGRAMS E5.1 SCHEDULES AND DETAILS E6.1 PANEL SCHEDULES ET.1 FAULT CURRENT ANALYSIS & COORDINATION STUDIES J PRINTED 24 "X36" NOT TO SCALE �o Co 0. °' cl UM M C� W LLi 0 o: W 0 „t US N w UW J Q m a ovc w 0 U 0 z z � o aLL N, LL �g Smith SSAL Beckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 W W W.ssr- inc.com ceMicaton - Ea- 0000367 D.®D_i. PE.5VAS Jahn E.H.ald. PE -83200 hGd.dA3be -d PE -85701 sseJOB s 1132063.0 Comm. No: 11_087.00 Date: 01/18/12 Drawn: Revised: \��tll ►Il► /// 0 5 1 A O LlSTATE T "4O,Ig OF N (( E01� �� O U_ Z J Q U_ cc F_ W Qr o O C0 cc = 0 J LL � F- J a � W Cj) a O O J = w O ~ V m W =aMF- C) :31 U co a = O * Q m O 0 N C4 O 0 Comm. No: 11_087.00 Date: 01/18/12 Drawn: Revised: \��tll ►Il► /// 0 5 1 A O LlSTATE T "4O,Ig OF N (( E01� ��